Search NASA⌕ Search

SEARCH · Search NASA

Results for “PEROXIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Bimodal effect of hydrogen peroxide and oxidative events in nitrite-induced rapid root abscission by the water fern Azolla pinnata

In the genus Azolla rapid abscission of roots from floating fronds occurs within minutes in response to a variety of stresses, including exposure to nitrite. We found that hydrogen peroxide, though itself not an inducer of root abscission, modulates nitrite-induced root abscission by Azolla pinnata in a dose-dependent manner, with 2 mM H 2 O 2 significantly diminishing the responsiveness to 2 mM NaNO 2 , and 10 mM H 2 O 2 slightly enhancing it. Hypoxia, which has been found in other plants to result in autogenic production of H 2 O 2 , dramatically stimulated root abscission of A. pinnata in response to nitrite, especially for plants previously cultivated in medium containing 5 mM KNO 3 compared to plants cultivated under N 2 -fixing conditions without combined nitrogen. Plants, including Azolla , produce the small signaling molecule nitric oxide (NO) from nitrite using nitrate reductase. We found Azolla plants to display dose-dependent root abscission in response to the NO donor spermine NONOate. Treatment of plants with the thiol-modifying agents S-methyl methanethiosulfonate or glutathione inhibited the nitrite-induced root abscission response. Synchrotron radiation-based Fourier transform infrared spectromicroscopy revealed higher levels of carbonylation in the abscission zone of dropped roots, indicative of reaction products of polysaccharides with potent free radical oxidants. Lastly, we hypothesize that metabolic products of nitrite and NO react with H 2 O 2 in the apoplast leading to free-radical-mediated cleavage of structural polysaccharides and consequent rapid root abscission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Translocation of Soybean MPK6, GmMPK6, Is Mediated by Hydrogen Peroxide in Salt Stress

The plant mitogen-activated protein kinase (MPK) cascade, a highly conserved signal transduction system in eukaryotes, plays a crucial role in the plant’s response to environmental stimuli and phytohormones. It is well-known that nuclear translocation of MPKs is necessary for their activities in mammalian cells. However, the mechanism underlying nuclear translocation of plant MPKs is not well elucidated. In the previous study, it has been shown that soybean MPK6 (GmMPK6) is activated by phosphatidic acid (PA) and hydrogen peroxide (H 2 O 2 ), which are two signaling molecules generated during salt stress. Using the two signaling molecules, we investigated how salt stress triggers its translocation to the nucleus. Our results show that the translocation of GmMPK6 to the nucleus is mediated by H 2 O 2 , but not by PA. Furthermore, the translocation was interrupted by diphenylene iodonium (DPI) (an inhibitor of RBOH), confirming that H 2 O 2 is the signaling molecule for the nuclear translocation of GmMPK6 during salt stress.

59 BASIC BIOLOGICAL SCIENCES↗

The Use of Liquid Isopropyl Alcohol and Hydrogen Peroxide Gas Plasma to Biologically Decontaminate Spacecraft Electronics

Legitimate concern exists regarding sending spacecraft and their associated hardware to solar system bodies where they could possibly contaminate the body's surface with terrestrial microorganisms. The NASA approved guidelines for sterilization as set forth in NPG 8020.12C, which is consistent with the biological contamination control objectives of the Committee on Space Research (COSPAR), recommends subjecting the spacecraft and its associated hardware to dry heat-a dry heat regimen that could potentially employ a temperature of 110(deg)C for up to 200 hours. Such a temperature exposure could prove detrimental to the spacecraft electronics. The stimulated growth of intermetallic compounds (IMCs) in metallic interconnects and/or thermal degradation of organic materials composing much of the hardware could take place over a prolonged temperature regimen. Such detrimental phenomena would almost certainly compromise the integrity and reliability of the electronics. Investigation of sterilization procedures in the medical field suggests that hydrogen peroxide (H202) gas plasma (HPGP) technology can effectively function as an alternative to heat sterilization, especially for heat-sensitive items. Treatment with isopropyl alcohol (IPA) in liquid form prior to exposure of the hardware to HPGP should also prove beneficial. Although IPA is not a sterilant, it is frequently used as a disinfectant because of its bactericidal properties. The use of IPA in electronics cleaning is widely recognized and has been utilized for many years with no adverse affects reported. In addition, IPA is the principal ingredient of the test fluid used in ionic contamination testers to assess the amount of ionic contamination found on the surfaces of printed wiring assemblies. This paper will set forth experimental data confirming the feasibility of the IPA/H202 approach to reach acceptable microbial reduction (MR) levels of spacecraft electronic hardware. In addition, a proposed process flow in which both IPA liquid and HPGP are utilized will be presented in Section 7.0.

microbial reduction↗

Vapor Hydrogen Peroxide as Alternative to Dry Heat Microbial Reduction

The Jet Propulsion Laboratory, in conjunction with the NASA Planetary Protection Officer, has selected vapor phase hydrogen peroxide (VHP) sterilization process for continued development as a NASA approved sterilization technique for spacecraft subsystems and systems. The goal is to include this technique, with appropriate specification, in NPG8020.12C as a low temperature complementary technique to the dry heat sterilization process. A series of experiments were conducted in vacuum to determine VHP process parameters that provided significant reductions in spore viability while allowing survival of sufficient spores for statistically significant enumeration. With this knowledge of D values, sensible margins can be applied in a planetary protection specification. The outcome of this study provided an optimization of test sterilizer process conditions: VHP concentration, process duration, a process temperature range for which the worst case D value may be imposed, a process humidity range for which the worst case D value may be imposed, and robustness to selected spacecraft material substrates.

vapor hydrogen peroxide↗

Hydrogen Peroxide on the Surface of Europa

Spatially resolved infrared and ultraviolet wavelength spectra of Europa's leading, anti-jovian, quadrant observed from the Galileo spacecraft show absorption features due to hydrogen peroxide.

Jupiter↗

NASA Engineering and Safety Center Technical Bulletin No. 21-01: Experimental and Computational Study of Cavitation in Hydrogen Peroxide

Cavitation in liquid propulsion systems can lead to performance degradation and hardware failures. The NESC sponsored an investigation to measure and model cavitation in pressurized hydrogen peroxide fl ow. The experimentally measured and computationally predicted cavitation lengths were compared as a function of cavitation number. The measured and predicted data exhibited close agreement over the range of pressures and temperatures studied, and no calibration of the cavitation model coefficients was needed.

NESC Technical Bulletin No. 21-01↗

The Influence of Chemical Descriptors on the Reactivity of Potential Hypergolic Fuels With Hydrogen Peroxide

The state-of-the-art for storable hypergolic bipropellant systems is monomethylhydrazine (MMH) and mixed oxides of nitrogen (MON). While MMH and MON provide fast and highly reliable hypergolic ignition with excellent propulsive performance, they suffer from safety concerns impacting their production, cost, and supply to various test and launch facilities. In contrast, identifying and demonstrating low-toxicity fuels hypergolic with rocket grade hydrogen peroxide (H2O2) has been challenging with long ignition delay (IDT) and low propulsive performance affecting their deployment in flight systems. This work describes a preliminary observational study to assess the effects of molecular descriptors suspected to predict the reactivity and hypergolicity of compounds within the same chemical class (i.e., thioamide). The approach centered on evaluating functional groups, electrostatic potential, number of carbons, dipole moment, and adiabatic ionization energy. Thiourea is hypergolic with 89.2 wt.% H2O2 (minimum IDT of 21.9 ms) and was selected as a core fuel to study the reactivity of derived fuels with different functionalities. Additionally, the chemical properties were calculated with the Gaussian16 suite. The results showed that group substitution and generally increased number of carbons on thiourea increases IDT. It was observed that a more positively charged sulfur atom in the thioamide does not increase the reactivity towards H2O2. The dipole moment analysis revealed an overall trend of decreasing IDT due to increasing dipole moment. Finally, a lower adiabatic ionization energy related to increased IDTs for most cases. Additional chemical classes comprising a wider range of functionalities and electrophilic attributes are being investigated in on-going work.

Propellant↗

Optimization of Crystals of an Inhibitory Antibody of Urokinase Plasminogen Activator Receptor (uPAR) with Hydrogen Peroxide and Low Protein Concentration

Optimization of protein crystal formation is often a necessary step leading to diffraction-quality crystals to enable collection of a full X-ray data set. Typical protein crystal optimization involves screening different components, e.g., pH, precipitants, and additives of the precipitant solution. Here we present an example using an inhibitory antibody of urokinase plasminogen activator receptor (uPAR) where such procedures did not yield diffracting crystals. In contrast, it was the treatment of the protein with hydrogen peroxide incubation and the protein concentration reduction that were found to be key factors in obtaining diffracting crystals. Final crystals diffracted to 1.75 {angstrom}, and belong to orthorhombic P212121 space group with unit cell parameters a = 37.162 {angstrom}, b = 84.474 {angstrom}, c = 134.030 {angstrom}, and contain one molecule of Fab fragment of anti-uro kinase receptor antibody in the asymmetric unit.

59 BASIC BIOLOGICAL SCIENCES↗

Shock initiation studies on high concentration hydrogen peroxide

Concentrated hydrogen peroxide (H{sub 2}O{sub 2}) has been known to detonate for many years. However, because of its reactivity and the difficulty in handling and confining it, along with the large critical diameter, few studies providing basic information about the initiation and detonation properties have been published. We are conducting a study to understand and quantify the initiation and detonation properties of highly concentrated H{sub 2}O{sub 2} using a gas-driven two-stage gun to produce well defined shock inputs. Multiple magnetic gauges are used to make in-situ measurements of the growth of reaction and subsequent detonation in the liquid. These experiments are designed to be one-dimensional to eliminate any difficulties that might be encountered with large critical diameters. Because of the concern of the reactivity of the H{sub 2}O{sub 2} with the confining materials, a remote loading system has been developed. The gun is pressurized, then the cell is filled and the experiment shot within less than three minutes. TV cameras are attached to the target so the cell filling can be monitored. Several experiments have been completed on {approx}98 wt % H{sub 2}O{sub 2}/H{sub 2}O mixtures; initiation has been observed in some experiments that shows homogeneous shock initiation behavior. The initial shock pressurizes and heats the mixture. After an induction time, a thermal explosion type reaction produces an evolving reactive wave that strengthens and eventually overdrives the first wave producing a detonation. From these measurements, we have determined unreacted Hugoniot information, times (distances) to detonation (Pop-plot points) that indicate low sensitivity, and detonation velocities of high concentration H{sub 2}O{sub 2}/H{sub 2}O solutions that agree with earlier estimates.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

THE SUITABILITY OF SODIUM PEROXIDE FUSION FOR PRODUCTION-SCALE PLUTONIUM PROCESSING OPERATIONS

Sodium peroxide (Na{sub 2}O{sub 2}) fusion is a method that offers significant benefits to the processing of high-fired plutonium oxide (PuO{sub 2}) materials. Those benefits include reduction in dissolution cycle time, decrease in residual solids, and reduction of the potential for generation of a flammable gas mixture during dissolution. Implementation of Na{sub 2}O{sub 2} fusion may also increase the PuO{sub 2} throughput in the HB-Line dissolving lines. To fuse a material, Na{sub 2}O{sub 2} is mixed with the feed material in a crucible and heated to 600-700 C. For low-fired and high-fired PuO{sub 2}, Na{sub 2}O{sub 2} reacts with PuO{sub 2} to form a compound that readily dissolves in ambient-temperature nitric acid without the use of potassium fluoride. The Savannah River National Laboratory (SRNL) demonstrated the feasibility of Na{sub 2}O{sub 2} fusion and subsequent dissolution for the processing of high-fired PuO{sub 2} materials in HB-Line. Testing evaluated critical dissolution characteristics and defined preliminary process parameters. Based on experimental measurements, a dissolution cycle can be complete in less than one hour, compared to the current processing time of 6-10 hours for solution heating and dissolution. Final Pu concentrations of 30-35 g/L were produced without the formation of precipitates in the final solution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Responsive Ion Selectivity of Uranyl Peroxide Nanocages: An Inorganic Mimic of K + Ion Channels

Abstract An actinyl peroxide cage cluster, Li 48+ m K 12 (OH) m [UO 2 (O 2 )(OH)] 60 (H 2 O) n ( m ≈20 and n ≈310; U 60 ), discriminates precisely between Na + and K + ions when heated to certain temperatures, a most essential feature for K + selective filters. The U 60 clusters demonstrate several other features in common with K + ion channels, including passive transport of K + ions, a high flux rate, and the dehydration of U 60 and K + ions. These qualities make U 60 (a pure inorganic cluster) a promising ion channel mimic in an aqueous environment. Laser light scattering (LLS) and isothermal titration calorimetry (ITC) studies revealed that the tailorable ion selectivity of U 60 clusters is a result of the thermal responsiveness of the U 60 hydration shells.

Gao, Yunyi↗

Electroless Deposition of Silver Nanoparticles on Graphene Oxide Surface and Its Applications for the Detection of Hydrogen Peroxide

We developed a new process to decorate graphene oxide (GO) with silver nanoparticles through electroless deposition technique, which was performed by treating GO with Sn 2+ first and then with Ag + . Furthermore, silver nanoparticles-GO (AgNPs-GO) nanocomposites were prepared by this technique. The process was monitored using UV-vis spectroscopy, Raman spectroscopy and transmission electron microscopy (TEM). The electrochemical behaviour of AgNPs-GO modified glassy carbon electrode was investigated by cyclic voltammetry. The potential application of this technique for hydrogen peroxide detection was tested with a range from 10 µM to 20 mM with a detection limit of 0.5 µM.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanoporous Pt(Au) Alloys for the Enhanced, Non–enzymatic Detection of Hydrogen Peroxide under Biofouling Conditions

The non-enzymatic electrochemical sensing of hydrogen peroxide (H 2 O 2 ) is described. This study utilized a 3D bicontinuous nanoporous platinum-gold alloy-based sensor (NP-Pt(Au) electrode), which has a morphology that resembles a molecular sieve. SEM and CV were used to evaluate the morphological and electrochemical characteristics of the NP-Pt(Au) electrodes. The cathodic voltammetric response of H 2 O 2 was enhanced at the NP-Pt(Au) as compared to planar Pt electrodes. Further, the nanoporous electrode was able to maintain the H 2 O 2 voltammetric profile even in the presence of the biofouling agent, serum albumin. Its application as a non-enzymatic sensor for the amperometric measurement of H 2 O 2 was explored.

36 MATERIALS SCIENCE↗

Single‐Atomic Site Catalyst with Heme Enzymes‐Like Active Sites for Electrochemical Sensing of Hydrogen Peroxide

Abstract Heme enzymes, with the pentacoordinate heme iron active sites, possess high catalytic activity and selectivity in biosensing applications. However, they are still subject to limited catalytic stability in the complex environment and high cost for broad applications in electrochemical sensing. It is meaningful to develop a novel substitute that has a similar structure to some heme enzymes and mimics their enzyme activities. One emerging strategy is to design the Fe‐N‐C based single‐atomic site catalysts (SASCs). The obtained atomically dispersed Fe‐N x active sites can mimic the active sites of heme enzymes effectively. In this work, a SASC (Fe‐SASC/NW) is synthesized by doping single iron atoms in polypyrrole (PPy) derived carbon nanowire via a zinc‐atom‐assisted method. The proposed Fe‐SASC/NW shows high heme enzyme‐like catalytic performance for hydrogen peroxide (H 2 O 2 ) with a specific activity of 42.8 U mg −1 . An electrochemical sensor based on Fe‐SASC/NW is developed for the detection of H 2 O 2 . This sensor exhibits a wide detection concentration range from 5.0 × 10 −10 m to 0.5 m and an excellent limit of detection (LOD) of 46.35 × 10 −9 m . Such excellent catalytic activity and electrochemical sensing sensitivity are attributed to the isolated Fe‐N x active sites and their structural similarity with natural metalloproteases.

Ding, Shichao↗

Iron-Imprinted Single-Atomic Site Catalyst-Based Nanoprobe for Detection of Hydrogen Peroxide in Living Cells

Fe-based single-atomic site catalysts (SASCs), with the natural metalloproteases-like active site structure, have attracted widespread attention in biocatalysis and biosensing. Precisely, controlling the isolated single-atom Fe-N-C active site structure is crucial to improve the SASCs’ performance. In this work, we use a facile ion-imprinting method (IIM) to synthesize isolated Fe-N-C single-atomic site catalysts (IIM-Fe-SASC). With this method, the ion-imprinting process can precisely control ion at the atomic level and form numerous well-defined single-atomic Fe-N-C sites. The IIM-Fe-SASC shows better peroxidase-like activities than that of non-imprinted references. Due to its excellent properties, IIM-Fe-SASC is an ideal nanoprobe used in the colorimetric biosensing of hydrogen peroxide (H 2 O 2 ). Using IIM-Fe-SASC as the nanoprobe, in situ detection of H 2 O 2 generated from MDA-MB-231 cells has been successfully demonstrated with satisfactory sensitivity and specificity. This work opens a novel and easy route in designing advanced SASC and provides a sensitive tool for intracellular H 2 O 2 detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗