Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SU-F-J-128: Dosimetric Impact of Esophagus Motion in Spine Stereotactic Body Radiotherapy

Purpose: Acute esophageal toxicity is a common side effect in spine stereotactic body radiotherapy (SBRT). The respiratory motion may alter esophageal position from the planning scan resulting in excessive esophageal dose. Here we assessed the dosimetric impact resulting from the esophageal motion using 4DCT. Methods: Nine patients treated to their thoracic spines in one fraction of 24 Gy were identified for this study. The original plan on a free breathing CT was copied to each phase image of a 4DCT scan, recalculated, scaled, and accumulated to the free breathing CT using deformable image registration. A segment of esophagus was contoured in the vicinity of treatment target. Esophagus dose volume histogram (DVH) was generated for both the original planned dose and the accumulated 4D dose for comparison. In parallel, we performed a chained deformable registration of 4DCT phase images to estimate the motion magnitude of the esophagus in a breathing cycle. We examined the correlation between the motion magnitude and the dosimetric deviation. Results: The esophageal motion mostly exhibited in the superior-inferior direction. The cross-sectional motion was small. Esophagus motion at T1 vertebra level (0.7 mm) is much smaller than that at T11 vertebra level (6.5 mm). The difference of Dmax between the original and 4D dose distributions ranged from 9.1 cGy (esophagus motion: 5.6 mm) to 231.1 cGy (esophagus motion: 3.1 mm). The difference of D(5cc) ranged from 5 cGy (esophagus motion: 3.1 mm) to 85 cGy (esophagus motion: 3.3 mm). There was no correlation between the dosimetric deviation and the motion magnitude. The V(11.9Gy)<5cc constraint was met for each patient when examining the DVH calculated from the 4D dose. Conclusion: Respiratory motion did not result in substantial dose increase to esophagus in spine SBRT. 4DCT simulation may not be necessary with regards to esophageal dose assessment.

60 APPLIED LIFE SCIENCES↗

Talbot-Lau based Moiré deflectometry with non-coherent sources as potential High Energy Density plasma diagnostic

X-ray phase-contrast radiography could better characterize highly localized density gradients expected in High Energy Density (HED) plasma experiments than conventional attenuation radiography. In particular, the Talbot-Lau (TL) grating interferometer, which works with extended and polychromatic x-ray sources, is a potentially attractive HED diagnostic due to its high sensitivity. For HED characterization the TL setup and imaging techniques must be changed from the recently studied medical system. The object magnification must be increased greatly in order to resolve μm scale gradients while the Talbot magnification must be increased in order to keep the gratings away from the plasma. Additionally, techniques for retrieving the density profile from a single plasma image must be developed. We thus study the performance of high magnification TL interferometers, in conjunction with Moiré fringe deflectometry for single image phase retrieval. The results show a very good interferometer contrast (≤30%) at high magnification. The Moiré technique enables measuring both sharp and mild density gradients with good accuracy and spatial resolution. Both the laboratory and simulation studies indicate that the TL based Moiré deflectometry is more sensitive than the propagation phase-contrast method when utilizing an extended x-ray source (∼80 μm). In HED experiments this would allow for less demanding X-ray backlighters than those used at present.

36 MATERIALS SCIENCE↗

Towards nanometer period gratings for hard x-ray phase-contrast imaging

Transmission grating-based x-ray interferometers have been developed into wide-field imaging devices that are sensitive to x-ray refraction and diffraction in the sample. While current grating designs rely on UV and x-ray lithography processes to produce periodic vertical structures, it becomes prohibitively difficult to make the grating periods below 1 - 2 microns due to the high aspect ratios of the structures. Since the phase-contrast sensitivity is inversely related to the grating period, we describe a new grating design for sub-micron to nanometer grating periods. In this design, multiple bi-layers of two alternating materials are deposited on a stair like substrate, and mostly on the floor surfaces of the steps only. The incident x-ray beam is parallel to the planes of the layers (side illumination). Thus, the multilayer structure on each step serves as a micro grating whose grating period is the thickness of a bi-layer. The array of micro gratings over the whole length of the stair can act as a single continuous grating, when certain continuity conditions between neighboring steps are met. Since the layer thickness can be as small as tens of nanometers, as has been demonstrated in multilayer x-ray zone plates, this design allows nanometer grating periods over large grating areas. Here we describe a prototype intensity grating of 440 nm period. We show x-ray projection images of the grating which were obtained by contact lithography.

36 MATERIALS SCIENCE↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging: BNL Phase II Activities (Final Report)

Over the last ten years, lower costs and government incentives for rooftop and utility scale solar photovoltaic (PV) systems have led to a rapid growth in the amount of power generated from this renewable energy source. For example, the cumulative PV generating capacity of 1,160 MW in New York State at the end of 2018 represents a growth of more than 4,000% over the past seven years and almost 400% over the past five years. But increased dependence on this inherently variable energy source introduces the need to anticipate, i.e., forecast, changes in energy production and manage them appropriately. Utilities and grid operators can then use this forecast information to balance changes and maintain stability of the electric grid by adding additional sources or diverting excess supplies for sale or storage, as needed. Current techniques based on persistence modeling are not accurate enough to provide reliable forecasts. With support from the U.S. Department of Energy’s Solar Energy Technology Office (DOE SETO) and the New York Power Authority (NYPA), Brookhaven National Laboratory (BNL), the National Center for Atmospheric Research (NCAR), and the Electric Power Research Institute (EPRI) formed a collaborative team to provide reliable forecasting over a range of time intervals. In addition, the forecasting area was scaled up to about 50 km2, a factor of 20 times larger than previously achieved, so that available solar irradiance could be forecast throughout an entire region including both large generating facilities and distributed rooftop solar arrays. In its role, BNL developed a technology for predicting changes in available solar energy from zero to 30 minutes ahead. This “nowcasting” approach uses inexpensive, off-the-shelf, high definition (HD) imagers with custom software to identify and track the movement of approaching clouds and predict their impact on available solar irradiance. The BNL Nowcasting model improves forecasting accuracy by 20 to 50% over current techniques. Forecasting reliability for low clouds (worst case scenario since they move over solar panels more rapidly than high clouds) was calculated to be 95% accurate for forecast periods of five minute ahead. Reliability decreases with longer forecast time intervals and was calculated to be about 80% for 10 minute forecasts, and about 70% for 20 minutes ahead. Clouds were still reliably tracked by the imager network at 60% accuracy for forecast lead times up to about 30 minutes ahead, and this was determined to be the practical nowcasting limit for low clouds in a network of this scale. This work represents the second phase of a multi-phase effort to develop and deploy solar forecasting at a regional scale so that contributions from distributed rooftop solar resources can be forecast along with solar generating facilities, giving utilities and stakeholders an accurate assessment of future energy production. Additional work is planned to operate the forecasting network in an area upstate New York to assess system reliability under diverse meteorological conditions and to monitor system performance over a full range of seasonal variability.

14 SOLAR ENERGY↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 1 of 2

This presentation describes the challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial-resolution system, and initial results from the first of these systems, built and successfully tested on the bench in Fiscal Year (FY) 2017. This system will be installed on a gas gun and tested during dynamic shock physics experiments in FY 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of x-ray speckle-based dark-field and phase-contrast imaging with a polychromatic beam

Following the first experimental demonstration of x-ray speckle-based multimodal imaging using a polychromatic beam [I. Zanette et al., Phys. Rev. Lett. 112(25), 253903 (2014)], we present a simulation study on the effects of a polychromatic x-ray spectrum on the performance of this technique. We observe that the contrast of the near-field speckles is only mildly influenced by the bandwidth of the energy spectrum. Moreover, using a homogeneous object with simple geometry, we characterize the beam hardening artifacts in the reconstructed transmission and refraction angle images, and we describe how the beam hardening also affects the dark-field signal provided by speckle tracking. This study is particularly important for further implementations and developments of coherent speckle-based techniques at laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Continuous measurement feedback control of a Bose-Einstein condensate using phase-contrast imaging

We consider the theory of feedback control of a Bose-Einstein condensate (BEC) confined in a harmonic trap under a continuous measurement constructed via nondestructive imaging. A filtering theory approach is used to derive a stochastic master equation (SME) for the system from a general Hamiltonian based upon system-bath coupling. Numerical solutions for this SME in the limit of a single atom show that the final steady-state energy is dependent upon the measurement strength, the ratio of photon kinetic energy to atomic kinetic energy, and the feedback strength. Simulations indicate that for a weak measurement strength, feedback can be used to overcome heating introduced by the scattering of light, thereby allowing the atom to be driven toward the ground state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noninterferometric phase-contrast images obtained with incoherent x-ray sources

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the method's potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times--all important aspects with regards to real-world implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗