Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Some methods in high energy cosmic ray measurement

Problems concerning ion chamber and emulsion detection techniques for high energy cosmic ray measurement are investigated. The calculation of the average energy actually deposited in an ion chamber by an ultra-high energy particle of large mass and charge is examined. A calculational scheme already applied successfully to particles of charge 1 is extended. Also, the calibration of a plate of plastic scintillator for measurement of the position of a cosmic ray shower passing through it is discussed. The method of calibration is to inject pulses of flight at known positions on the plate and record the responses of photomultiplier tubes at the corner of the plate.

Shand, J. B., Jr.↗

Atmospheric Emission Photometric Imaging on Spacelab (AEPI)

Two parallel detector systems are used for atmospheric emission photometric emission. The top system is a TV system using the image intensified S.E.C. tube as the detector. The bottom system, the photon counting array (P.C.A.), uses a microchannel plate intensified anode array tube and is equivalent to a 100 channel photomultiplier. For the television, the filters are selected by means of a filter wheel set. The field of view of the is interchangeable between 20 and 6 degrees, by means of a moveable prism. The quartz window mu channel plate intensifier is fiber optically coupled to a 40-25 demagnifying tube which is in turn coupled to the S.E.C. tube. The PCA channel has a fixed field of view of 4 deg and a remote control interchangeable photometric converter optics which converts the imaging array into a multichannel photometer. The mu channel plate array tube amplifies the photons into detectable counts for the PCA electronics. The entire system is pointed by a two axis gimbal. The flight equipment to be acquired consists of a gyro package and an interactive flight control unit panel. The gyro package is necessary because of the inadequate attitude reference supplied by the current Spacelab systems.

Mende, S. B.↗

Test techniques for determining laser ranging system performance

Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.

Zagwodzki, T. W.↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗

Cerenkov x total energy telescopes for the study of the mass composition of cosmic rays

The mass resolution attainable with cosmic ray telescopes employing Cerenkov counters for velocity measurement was examined. It is shown that in most cases, the limiting mass resolution is determined by the resolution of the Cerenkov counter. The resolution achieved in the UNH telescope flown on a balloon in 1977 is studied as a function of charge and energy. This telescope determines the mass using the Cerenkov x total energy technique. It is shown that the mass resolution for heavier nuclei can be accurately predicted using the response of the Cerenkov counter to sea level mu-mesons. The actual in flight resolution for heavier nuclei, including broadening effects, may be predicted using the beta = 1 Cerenkov distributions, and independently by studying the distribution function of the differences of the two banks of photomultipliers employed on each Cerenkov counter.

Webber, W. R.↗

Design and performance of the solar maximum mission Hard X-ray Burst Spectrometer

The Hard X-ray Burst Spectrometer acquires data on the temporal and energy distribution of solar X-rays in the energy region from 25 to 385 keV. The detector system is a CsI(Na) central detector, and an anti-coincidence shield with photomultiplier tubes optically coupled to the central and shield crystals. Additional detectors are included for calibration and South Atlantic Anomaly monitoring. A 15 channel pulse height analysis is performed over the energy range every 128 milliseconds. This instrument is capable of handling event rates up to 500 kHz and provides high rate data up to 100 kHz with low spectral distortion. Nine accumulated rates are telemetered every 8.192 seconds. A unique feature of the instrument is the ability to sample rates from the central detector or shield with a one millisecond minimum time resolution. Such samples are stored in a 32768 sample memory with a 40 percent pretrigger event history and a 60 percent posttrigger history.

Workman, L. G.↗

Performance and design of the ultraviolet spectrometer and polarimeter on the solar maximum mission

The instrument observes spectral line intensity, Doppler motions, and polarization parameters. First Dopplergrams of the sun showing mass motion of prominences have been obtained. The instrument consists of a telescope, a spectrometer, a polarimeter, and five detectors. Spectral range extends from 1150 to 3600 Angstroms. The telescope is an alphanatic Gregorian capable of scanning a 256 x 256 arcsecond raster. The spectrometer is an Ebert-Fastie mount with exchangeable slits for intensity measurements and spectroscopy. Detectors are photomultipliers operating in the pulse-counting mode.

Sterk, A. A.↗

Observations of fast oscillations in SS Cygni

High-speed photometric observations of the dwarf nova SS Cygni have been made using an ultraviolet and blue sensitive photomultiplier. Rapid oscillations were detected over an interval of 7 days. The period of the oscillations passed through a minimum of 7.29 s, the shortest period yet observed in a dwarf nova. The signal was spread in frequency by an amount larger than required by the slow evolution of the period. The data are considered from the viewpoint of several models.

Hildebrand, R. H.↗

Nuclear Science Symposium, 27th, and Symposium on Nuclear Power Systems, 12th, Orlando, Fla., November 5-7, 1980, Proceedings

Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.

Martini, M.↗

Atmospheric emissions photometric imaging experiment /AEPT/ for Spacelab 1

The atmospheric emissions photometric imaging experiment (AEPI) to be flown on Spacelab 1 is designed to study faint natural and artificial atmospheric emission phenomena. Optical emissions are imaged in the region 2150 A to 7320 A using a television system consisting of two optical channels, one wide-angle and one telephoto. The detection system is an image-enhanced SEC vidicon. A third optical channel images onto the photocathode of a microchannel plate photomultiplier tube that has 100 discrete anodes. Photons are counted for each discrete anode, providing a direct measure of the luminosity of an object viewed by the TV telephoto lens, albeit with low spatial resolution. The AEPI detector is mounted on a two-axis gimbal comprised of a Modified Apollo Telescope Mount Star Tracker (MAST), which provides experiment pointing over a 40-deg x 80-deg range, exclusive of restrictions due to the proximity of other experiments. The pointing stability is 1 arcmin with respect to the spacecraft coordinate system for an exposure of 1 second. The tracking capability is 3.5 deg/s with a stability of 1 arcmin. The detector and pointing system are located on the Spacelab pallet. The experiment is controlled by stored programs resident in the Dedicated Experiment Processor located in the Spacelab module.

Sandie, W. G.↗

Lyman-alpha fluorescence from hydrogen photofragments of CH4 and H2O

The process of H-Lyman-alpha fluorescence produced through photodissociation of CH4 and H2O provides an example for the usefulness of the detection of fluorescence of dissociation fragments as an aid in identifying some high lying Rydberg states. In the first experiment reported, an electron storage ring synchrotron radiation source was used. The fluorescence produced was detected with a solar blind photomultiplier and a Cs photocathode with a spectral sensitivity in the wavelength range from 1050 to 1950 A. In the second experiment considered, an intense atomic line source was employed.

Wu, C. Y. R.↗

Optical absorption of carbon and hydrocarbon species from shock heated acetylene and methane in the 135-220 nm wavelength range

Absorption spectroscopy of carbon and hydrocarbon species has been performed in a shock tube at an incident shock condition for a wavelength range of 135-220 nm, in order to obtain information needed for calculating radiation blockage ahead of a planetary probe. Instrumentation consisted of high frequency response pressure transducers, thin-film heat transfer gages, or photomultipliers coupled by light pipes. Two test-gas mixtures, one with acetylene and the other with methane, both diluted with argon, were used to provide a reliable variation of C3 and C2H concentration ratio. Comparison of tests results of the two mixtures, in the temperature range of 3750 + or - 100 K, showed the main absorbing species to be C3. The wavelength for maximum absorption agrees well with the theoretical values of 7.68 eV and 8.03 eV for the vertical excitation energy, and a value of 0.90 for the electronic oscillator strength, obtained from the measured absorption band, is also in good agreement with the predicted value of 0.92.

Shinn, J. L.↗

Cross section for Ly-alpha emission by electron impact on methane

Utilizing Lyman-alpha emission cross sections for H2 as secondary standards, absolute values of Lyman-alpha emission cross sections for CH4 have been obtained for electron impact energies varying from threshold to 100 eV. A crossed electron beam-molecular beam geometry was employed and the Lyman-alpha radiation was detected at 90 deg and 45 deg with respect to the incident electron beam by a solar blind photomultiplier in tandem with an oxygen filter. The results are compared with previous measurements. Appreciable differences among the various experimental data are found.

Orient, O. J.↗

Fiber optics transmission of LV signal

The first use of a long optical fiber for transmitting megahertz frequencies in a laser velocimeter (LV) receiver system is reported. The fiber comprises a 600-micron diameter fused silica core, a silicon polymer cladding and a plastic jacket. The fiber numerical aperture is 0.22, corresponding to a maximum entrance half-angle of 0.22 rad. The 10-m length used results in a 5.6% attenuation loss. The fiber is found to transmit an 80-MHz signal with excellent resolution. It is established that an LV receiver using fiber optics sends a clean signal in electronically noisy and high-pressure environments and allows velocity measurements in places too small for a photomultiplier tube.

Young, A. D.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Infrared fiber optic focal plane dispersers

Far infrared transmissive fiber optics as a component in the design of integrated far infrared focal plane array utilization is discussed. A tightly packed bundle of fibers is placed at the focal plane, where an array of infrared detectors would normally reside, and then fanned out in two or three dimensions to individual detectors. Subsequently, the detectors are multiplexed by cryogenic electronics for relay of the data. A second possible application is frequency up-conversion (v sub 1 + v sub 2 = v sub 3), which takes advantage of the nonlinear optical index of refraction of certain infrared transmissive materials in fiber form. Again, a fiber bundle is utilized as above, but now a laser of frequency v sub 1 is mixed with the incoming radiation of frequency v sub 1 within the nonlinear fiber material. The sum, v sub 2 is then detected by near infrared or visible detectors which are more sensitive than those available at v sub 2. Due to the geometrical size limitations of detectors such as photomultipliers, the focal plane dispersal technique is advantageous for imaging up-conversion.

Goebel, J. H.↗

Error probabilities in optical PPM receivers with Gaussian mixture densities

A Gaussian mixture density arises when a discrete variable (e.g., a photodetector count variable) is added to a continuous Gaussian variable (e.g., thermal noise). Making use of some properties of photomultiplier Gaussian mixture distributions, some approximate error probability formulas can be derived. These appear as averages of M-ary orthogonal Gaussian error probabilities. The use of a pure Gaussian assumption is considered, and when properly defined, appears as an accurate upper bound to performance.

Gagliardi, R. M.↗

Double Compton scatter telescope calibration

Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.

Dayton, B.↗