Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASTIC SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Detector for measuring the π + → e + v branching fraction

The PIENU experiment at TRIUMF is aimed at a measurement of the branching ratio R e/u = Γ((π + → e + v e ) + (π + → e + v e γ))/Γ((π + → μ + v μ ) + (π + → μ + v μ γ)) with precision < 0.1%. Incident pions, delivered at the rate of 60 kHz with momentum 75 MeV/c, were degraded and stopped in a plastic scintillator target. Pions and their decay product positrons were detected with plastic scintillators and tracked with multiwire proportional chambers and silicon strip detectors. The energies of the positrons were measured in a spectrometer consisting of a large NaI(Tℓ) crystal surrounded by an array of pure CsI crystals. This paper provides a description of the PIENU experimental apparatus and its performance in pursuit of R e/u

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Melt Blending: A Tool to Simplify Plastic Scintillator Synthesis

Plastic scintillators are widely used as radiation detection media in homeland security and nuclear physics applications. Their attributes include low cost, scalability to large detector volumes, and additive compounding to enable additional material and detection features, such as pulse shape discrimination (PSD), gamma-ray spectroscopy, aging resistance, and coincidence timing. However, traditional chemically cured plastic scintillators (CCS) require long reaction times, and hazardous wet chemical procedures performed by specially trained personnel, and can leave residual monomer, resulting in deleterious optical and material properties. Here, we synthesize melt blended scintillators (MBSs) in 2.5 days using easily accessible solid-state compounding of commercially-available poly(styrene) with 30–60 wt% fluorene-based compound “P2” to create monolithic detectors with < 100 ppm residual monomer, in several form factors. Further, the best scintillation performance was recorded for 60 wt% P2 in Styron 665, including gamma-ray light yield 139% of EJ- 200 commercial scintillator and PSD figure of merit (FOM) value of 2.65 at 478 keVee, approaching P2 organic glass scintillator (OGS). The capability of MBS to generate fog-resistant scintillators and poly(methyl methacrylate) (PMMA)-based scintillators for use in challenging environments is also demonstrated.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Large Area Plastic Scintillator Project (ALPS): Final Report

The advanced Large-Area Plastic Scintillator (ALPS) Project at Pacific Northwest National Laboratory investigated possible technological avenues for substantially advancing the state-of-the-art in gamma-ray detection via large-area plastic scintillators. The three predominant themes of these investigations comprised the following: * Maximizing light collection efficiency from a single large-area sheet of plastic scintillator, and optimizing hardware event trigger definition to retain detection efficiency while exploiting the power of coincidence to suppress single-PMT "dark current" background; * Utilizing anti-Compton vetoing and supplementary spectral information from a co-located secondary, or "Back" detector, to both (1) minimize Compton background in the low-energy portion of the "Front" scintillator's pulse-height spectrum, and (2) sharpen the statistical accuracy of the front detector's low-energy response prediction as impelmented in suitable energy-windowing algorithms; and * Investigating alternative materials to enhance the intrinsic gamma-ray detection efficiency of plastic-based sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manufacturing and characterization of a boron-loaded fast-cured plastic organic scintillator

A novel fast-cured, boron-loaded, plastic organic scintillator was developed and characterized. A diisopropylnaphthalene-containing scintillator was manufactured in minutes with the addition of two commercially available fast-curing monomers, isobornyl acrylate (IBOA) and 1,6-Hexanediol dimethacrylate (HDDMA). Further, the light yield of the device was measured to be approximately 70% relative to a similarly sized, but several-year-aged, EJ-276 detector. Using a coincidence capture technique, the neutron capture light output was found to be 87.7 ± 4.2 keVee, which was 1.47 ± 0.07 greater than the light output from a 59.5 keV electron. Producing a viable fast-cured and thermal-neutron-sensitive detector enables the capability to pursue cost-effective 3D printed thermal neutron detectors in a timely manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗

Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 1 m2 Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a 137Cs source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by ~0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by ~0.5 mCi when compared to a NaI(Tl) absorption plane.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A system to measure isomeric state half-lives in the 10 ns to 10 μs range

The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4) keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed study of the decay Cl 31 ( β γ ) S 31

Background: 31 Cl is a neutron-deficient isotope with a half-life of T 1/2 = 190 (1) ms. The nuclear structure of its daughter, 31 S, is important for the determination of the thermonuclear 30 P(p,γ) 31 S reaction rate, which affects the final isotopic abundances of the ejecta from classical oxygen-neon novae. Purpose: Here, we aim to determine the β feedings, γ-decay branchings, and excitation energies of states populated in 31 S and create a comprehensive decay scheme for comparison with predictions based on the shell model. Methods: Using a 31 Cl rare istope beam implanted into a plastic scintillator and an array of high-purity Ge detectors, γ rays from the 31 Cl(βγ) 31 S decay sequence were measured. Shell-model calculations using the USDB and the recently-developed USDE interactions were performed for comparison. Results: A 31 Cl β-decay scheme was constructed from the experimental data and compared to the USDB and USDE shell-model calculations based on the β feeding and γ-decay branches of each observed state. 33 new γ-ray transitions and ten new β decay branches were observed. The β feeding and γ-decay branches of each observed state were compared to those from the USDB and USDE shell-model calculations. For every allowed transition predicted by the USD calculations up to an excitation energy of 6.4 MeV in 31 S, an analogous transition was found in the experimental data, enabling a one-to-one comparison with the shell model. Using these identifications, spin and parity arguments were made for observed states. Conclusions: The new 31 Cl γ-decay scheme presented in this work is the most complete and precise one for this nucleus constructed to date, incorporating statistics over an order of magnitude higher than previous work on 31 Cl β-delayed γ decay. Of particular interest is the discovery of a 6390-keV state that mixes with the isobaric analog state and affects the 30 P(p,γ) 31 S reaction rate. Other states observed in the decay are not expected to strongly affect the 30 P(p,γ) 31 S reaction rate, but the comprehensive comparison to the shell model helps to clarify spin and parity assignments of resonances that might affect the rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference.

Mitchell, John W.↗

Development of an In-Beam Neutron Flux Monitor for Time of Flight Capture Measurements

Accurate nuclear data are important in several aspects of nuclear engineering, such as reactor simulations, nonproliferation, and criticality safety. One of the nuclear data measurements that requires reduced uncertainties in its related cross-sections is neutron capture. The neutron capture cross-sections have particular deficiencies in the incident neutron energy range from 1 keV to 1 MeV. This is due to the predominance of scattering reactions in this energy region. In order to provide more accurate measurements in this energy region, a new experimental setup has been designed and created at Rensselaer Polytechnic Institute (RPI). This experiment utilizes several C{sub 6}D{sub 6} detectors in a low mass system to minimize the effects of neutron scattering on the experiment. In order to determine the capture yield for the measurements, several additional factors need to be known about the neutron beam including the energy dependence of the neutron flux incident on the sample. A detector made from a thin piece of EJ-204 plastic scintillator was designed to measure the neutron flux, as a function of incident neutron energy, during the capture measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PVT and LaBr{sub 3}(Ce)-based Radon Express Analyzers - 18164

RadComm Systems has developed a new technology for quick, express analyzing (∼ 5 minutes) of Radon concentration in the air by using low energy resolution plastic PVT (polyvinyl toluene) -based scintillator and high energy resolution Lanthanum Bromide inorganic scintillator as the gamma-detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Scintillation Probes For Investigation Of Pulsed Neutron Radiation From Small Fusion Devices

This paper presents the design as well as laboratory/performance tests results taken by means of the fast scintillation probes. The design of each scintillation probe is based on photomultiplier tube hybrid assembly, which--besides photomultiplier itself--also includes high-voltage divider optimized for recording of fast radiation bursts. Plastic scintillators with short-time response are applied as hard X-ray and neutron radiation detectors. Heavy-duty probe's housing provides efficient shielding against electromagnetic interference and allows carrying out pulsed neutron measurements in a harsh electromagnetic environment. The crucial parameters of scintillation probes have been examined during laboratory tests in which our investigations have been aimed mainly to determine: a time response, an anode radiant sensitivity and an electron transit time dependence on high-voltage supply. During the performance tests, the relative calibration of probes set has been done. It allowed to carry out very accurate measurements of neutron emission anisotropy and investigations of neutron radiation scattering by different materials. The usefulness of presented scintillation probes - embedded in the neutron time-of-flight diagnostic system was proven during experimental campaigns conducted on the plasma-focus PF1000 device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Scintillating Optical Fiber Isotope Experiment

This paper describes the Scintillating Optical Fiber Isotope Experiment (SOFIE) which is being developed by Washington University and the University of New Hampshire to study the abundances of cosmic ray isotopes in the iron charge region. This detector system is a Cerenkov-Range-dE/dx experiment and utilizes range and trajectory detectors made of scintillating optical fibers, a fused silica Cerenkov counter, and plastic scintillator dE/dx counters to determine the charge and mass of cosmic ray nuclei. A brief description of the balloon flight instrument presently being developed will be given followed by initial results of an engineering model calibration at the LBL Bevalac heavy ion accelerator. In addition a brief discussion of the potential of scintillating fiber trajectory detectors for use in experiments requiring precise trajectory determination such as those being planned for the NASA Particle Astrophysics Magnet Facility (Astromag) program is presented.

Binns, W. Robert↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability

Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coated Fiber Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Reported here are the results of tests of the 6Li/ZnS(Ag)-coated non-scintillating plastic fibers option. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Innovative American Technology (IAT).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗