Search NASA⌕ Search

SEARCH · Search NASA

Results for “POSTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Role of orientation reference selection in motion sickness

Previous experiments with moving platform posturography have shown that different people have varying abilities to resolve conflicts among vestibular, visual, and proprioceptive sensory signals used to control upright posture. In particular, there is one class of subjects with a vestibular disorder known as benign paroxysmal positional vertigo (BPPV) who often are particularly sensitive to inaccurate visual information. That is, they will use visual sensory information for the control of their posture even when that visual information is inaccurate and is in conflict with accurate proprioceptive and vestibular sensory signals. BPPV has been associated with disorders of both posterior semicircular canal function and possibly otolith function. The present proposal hopes to take advantage of the similarities between the space motion sickness problem and the sensory orientation reference selection problems associated with the BPPV syndrome. These similarities include both etiology related to abnormal vertical canal-otolith function, and motion sickness initiating events provoked by pitch and roll head movements. The objectives of this proposal are to explore and quantify the orientation reference selection abilities of subjects and the relation of this selection to motion sickness in humans.

Peterka, Robert J.↗

Industrial applications of the microgravity environment

Opportunities for commercialization of the microgravity environment will depend upon the success of basic research projects performed in space. Significant demands for manufacturing opportunities are unlikely in the near term. The microgravity environment is to be considered primarily as a tool for research and secondarily as a manufacturing site. This research tool is unique, valuable, and presently available to U.S. investigators only through resources provided by NASA. The United States has an obligation to facilitate corporate research, maintain a flexible international policy, foster use of and assure access to a wide variety of facilities, and develop a posture of national and international leadership in and stewardship of research and materials processing in the microgravity environment. The National Research Council's Committee on Industrial Applications of the Microgravity Environment recommends six actions that strengthen this posture, including the formation of an authoritative organization to oversee the implementation of a program of microgravity research and its industrial applications.

Source record↗

Influence of single hindlimb support during simulated weightlessness in the rat

A study was carried out to develop and evaluate a hindlimb suspension model, making it possible to differentiate the effects of non-weight bearing by hindlimbs per se from the systemic influence of simulated weightlessness. A support platform was designed which allowed the animal to maintain one hindlimb in a posture similar to the hindlimbs of the control animals at rest and to maintain one hindlimb in a posture similar to the hindlimbs of the control animals, providing a support for the animal to contract or stretch hindlimb muscles against at any time during suspension. The results of this study indicated that hindlimb support during head-down suspension will maintain muscle-mass/body-mass ratios, glycogen concentration, and blood flow. However, it will not prevent the loss in citrate synthase activity associated with conditions of simulated weightlessness.

Stump, Craig S.↗

Microgravity enhances the relative contribution of visually-induced motion sensation

Visually-induced self-motion sensation and postural reflexes were first explored in microgravity on the Spacelab 1 mission where four subjects demonstrated that visual orientation effects were stronger in microgravity than preflight. Extended testing of two more subjects during the Spacelab D-1 orbital flight confirmed this finding. The development of visual substitution for inappropriate graviceptor information occurs over the first day or two in microgravity. Additional instrumentation to measure postural reactions failed to produce a more reliable indicator of visual effects than subjective orientation. Localized tactile cues applied to the feet changed the qualitative nature of vection and reduced its subjective strength.

Young, L. R.↗

Optimum structural design of robotic manipulators with fiber reinforced composite materials

High-speed robotic arms with advanced structural characteristics can be fabricated from optimally tailored fiber reinforced composites. An integrated design methodology is presented for the optimal structural synthesis of composite robotic manipulators. Optimum configurations of ply angles and ply thicknesses are predicted for maximum structural end-effector stiffness and maximum end-effector load carrying capacity, without altering the geometric dimensions of the links. Multiple posture finite element-based static performance criteria are implemented. A new finite element has been developed for the modeling of tubular composite links. Unique features are the inclusion of shear effects and coupling between stretching and flexure. Numerical solutions are obtained via an efficient optimization algorithm. Applications to an existing SCARA-class manipulator illustrate the effectiveness of the method and demonstrate the dramatic influence of the multi-postural design criteria on the optimal design. For a filament wound structure using a high strength carbon fiber in a thermoplastic matrix, the resultant optimum ply configurations have increased the specific stiffness and specific load capacity by factors of 1.5 and 16, respectively, in comparison to identically sized aluminum links.

Saravanos, D. A.↗

Transcapillary fluid shifts in head and neck tissues during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during, and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip: capillary pressures increased from 27.2 +/- 5 mm Hg pre-HDT to 33.9 +/- 1.7 mm Hg by the end of tilt. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values, despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr. These results indicate that facial edema resulting from HDT is primarily caused by elevated capillary pressures and decreased plasma colloid osmotic pressures. Elevation of cephalic capillary pressures sustained for 4 hr after HDT suggests that there is a compensatory vasodilation to maintain microvascular perfusion. The negativity of interstitial fluid pressures above heart level also has implications for the maintenance of tissue fluid balance in upright posture.

Parazynski, S. E.↗

Visually guided control of movement in the context of multimodal stimulation

Flight simulation has been almost exclusively concerned with simulating the motions of the aircraft. Physically distinct subsystems are often combined to simulate the varieties of aircraft motion. Visual display systems simulate the motion of the aircraft relative to remote objects and surfaces (e.g., other aircraft and the terrain). 'Motion platform' simulators recreate aircraft motion relative to the gravitoinertial vector (i.e., correlated rotation and tilt as opposed to the 'coordinated turn' in flight). 'Control loaders' attempt to simulate the resistance of the aerodynamic medium to aircraft motion. However, there are few operational systems that attempt to simulate the motion of the pilot relative to the aircraft and the gravitoinertial vector. The design and use of all simulators is limited by poor understanding of postural control in the aircraft and its effect on the perception and control of flight. Analysis of the perception and control of flight (real or simulated) must consider that: (1) the pilot is not rigidly attached to the aircraft; and (2) the pilot actively monitors and adjusts body orientation and configuration in the aircraft. It is argued that this more complete approach to flight simulation requires that multimodal perception be considered as the rule rather than the exception. Moreover, the necessity of multimodal perception is revealed by emphasizing the complementarity rather than the redundancy among perceptual systems. Finally, an outline is presented for an experiment to be conducted at NASA ARC. The experiment explicitly considers possible consequences of coordination between postural and vehicular control.

Riccio, Gary E.↗

Evaluation of tests for vestibular function

Vestibular testing methodologies are examined in terms of their clinical value and applicability to the assessment of astronaut candidates and human responses to microgravity. Classical and novel testing approaches are examined in terms of nine functions such as otolith organs, vestibular neural processing, and ocular motor systems. The tests reviewed include the basic vestibular-function test battery, postural stability testing, visual-vestibular interaction, reactions to off-axis rotation, and vestibular evoked responses. The basic test battery is shown to be essential for astronaut and inertial-environment baseline-data evaluations, whereas the newer and research tests are only recommended in special cases. Stimulus rearrangement and motion-sickness tests are indicated for testing adaptation to inertial environments. Postural stability and visual-vestibular interaction are recommended for evaluating one's suitability for being an astronaut.

Source record↗

The impact of visual noise on spatial orientation

The effect of noise in the visual environment on spatial orientation was investigated experimentally using postural stability as an objective measure. Noise in the displays was produced by randomly shifting the phase lag of the three-dimensional motion function for each individual point within the display. Greater postural sway was induced by displays containing no noise in the global optical flow pattern than displays containing noise, suggesting that spatial orientation is strongly dependent on global optic flow information in the visual field. To avoid pilot disorientation in some flight maneuvers, it is recommended that visual aids specifying global optic flow information be included in aircraft for flight environments with deficient global optic flow information.

Dyre, Brian P.↗

Exercise countermeasures for bed-rest deconditioning

The purpose for this 30-day bed rest study was to investigate the effects of short-term, high intensity isotonic and isokinetic exercise training on maintenance of working capacity (peak oxygen uptake), muscular strength and endurance, and on orthostatic tolerance, posture and gait. Other data were collected on muscle atrophy, bone mineralization and density, endocrine analyses concerning vasoactivity and fluid-electrolyte balance, muscle intermediary metabolism, and on performance and mood of the subjects. It was concluded that: The subjects maintained a relatively stable mood, high morale, and high esprit de corps throughout the study. Performance improved in nearly all tests in almost all the subjects. Isotonic training, as opposed to isokinetic exercise training, was associated more with decreasing levels of psychological tension, concentration, and motivation; and improvement in the quality of sleep. Working capacity (peak oxygen uptake) was maintained during bed rest with isotonic exercise training; it was not maintained with isokinetic or no exercise training. In general, there was no significant decrease in strength or endurance of arm or leg muscles during bed rest, in spite of some reduction in muscle size (atrophy) of some leg muscles. There was no effect of isotonic exercise training on orthostasis, since tilt-table tolerance was reduced similarly in all three groups following bed rest. Bed rest resulted in significant decreases of postural stability and self-selected step length, stride length, and walking velocity, which were not influenced by either exercise training regimen. Most pre-bed rest responses were restored by the fourth day of recovery.

Greenleaf, John↗

Ventilatory inhomogeneity determined from multiple-breath washouts during sustained microgravity on Spacelab SLS-1

We used multiple-breath N2 washouts (MBNW) to study the homogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from (1) distribution of specific ventilation (SV) from mixed-expired and (2) end-tidal N2, (3) change of slope of N2 washout (semilog plot) with time, (4) change of slope of normalized phase III of successive breaths, (5) anatomic lead dead space, and (6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV and significantly greater changes in the changes in slope of the N2 washouts, indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.

Prisk, G. Kim↗

The effect of space flight on spatial orientation

Both during and following early space missions, little neurosensory change in the astronauts was noted as a result of their exposure to microgravity. It is believed that this lack of in-flight adaptation in the spatial orientation and perceptual-motor system resulted from short exposure times and limited interaction with the new environment. Parker and Parker (1990) have suggested that while spatial orientation and motion information can be detected by a passive observer, adaptation to stimulus rearrangement is greatly enhanced when the observer moves through or acts on the environment. Experience with the actual consequences of action can be compared with those consequences expected on the basis of prior experience. Space flight today is of longer duration, and space craft volume has increased. These changes have forced the astronauts to interact with the new environment of microgravity, and as a result substantial changes occur in the perceptual and sensory-motor repsonses reflecting adaptation to the stimulus rearrangement of space flight. We are currently evaluating spatial orientation and the perceptual-motor systems' adaptation to microgravity by examining responses of postural control, head and gaze stability during locomotion, goal oriented vestibulo-ocular reflex (VOR), and structured quantitative perceptual reports. Evidence suggests that humans can successfully replace the gravitational reference available on Earth with cues available within the spacecraft or within themselves, but that adaptation to microgravity is not appropriate for a return to Earth. Countermeasures for optimal performance on-orbit and a successful return to earth will require development of preflight and in-flight training to help the astronauts acquire and maintain a dual adaptive state. An understanding of spatial orientation and motion perception, postural control, locomotion, and the VOR will aid in this process.

Reschke, Millard F.↗

The Personal Motion Platform

The Neutral Body Posture experienced in microgravity creates a biomechanical equilibrium by enabling the internal forces within the body to find their own balance. A patented reclining chair based on this posture provides a minimal stress environment for interfacing with computer systems for extended periods. When the chair is mounted on a 3 or 6 axis motion platform, a generic motion simulator for simulated digital environments is created. The Personal Motion Platform provides motional feedback to the occupant in synchronization with their movements inside the digital world which enhances the simulation experience. Existing HMD based simulation systems can be integrated to the turnkey system. Future developments are discussed.

Park, Brian Vandellyn↗

Adaptation of Baroreflexes and Orthostatic Hypotension

The footward shift of blood volume and compensatory autonomic reflex responses initiated during the assumption of the upright posture in terrestrial gravity is a common feature in humans. When regular exposure to upright posture is removed, the headward redistribution of blood induces numerous physiological adaptations which compromise this normal response and the development of low blood pressure upon standing (orthostatic hypotension) can ensue. Such microgravity conditions can be produced by prolonged exposure to spaceflight or prolonged bed rest. Since the reduction of blood and plasma volume during exposure to microgravity has been associated with orthostatic instability following spaceflight and bed rest, it has been a reasonable assumption that hypovolemia may be a primary contributing factor to the development of orthostatic hypotension. This view was supported by the observation that the attempt to restore vascular volume in astronauts by drinking saline solutions just prior to re-entry had proven effective in reducing orthostatic instability after spaceflights of short duration. However, as the duration of spaceflight lengthens, orthostatic instability persists despite fluid loading procedures, suggesting that mechanisms other than hypovolemia may contribute to orthostatic hypotension following prolonged exposure to microgravity conditions. Recent evidence has been generated from spaceflight and groundbase experiments that supports the notion that changes in autonomic baroreflexes that control cardiac and vascular responses during orthostatic challenges may be affected by longer periods of microgravity exposure and can contribute to postflight orthostatic instability.

Convertino, Victor A.↗

A Comparison of the Physiology and Mechanics of Exercise in LBNP and Upright Gait

Bone, muscular strength, aerobic capacity, and normal fluid pressure gradients within the body are lost during bed rest and spaceflight. Lower Body Negative Pressure (LBNP) exercise may create musculoskeletal and cardiovascular strains equal to a greater than those experienced on Earth and elucidate some of the mechanisms for maintaining bone integrity. LBNP exercise simulates gravity during supine posture by using negative pressure to pull subjects inward against a treadmill generating footward forces and increasing transmural pressures. Footward forces are generated which equal the product of the pressure differential and the cross-sectional area of the LBNP waist seal. Subjects lie supine within the chamber with their legs suspended from one another via cuffs, bungee cords, and pulleys, such that each leg acts as a counterweight to the other leg during the gait cycle. The subjects then walk or run on a treadmill which is positioned vertically within the chamber. Supine orientation allows only footward force production due to the negative pressure within the chamber. The purpose of this study was to determine if the kinematics, kinetics, and metabolic rate during supine walking and slow running on a vertical treadmill within LBNP are similar to those on a treadmill in 1-g environment in an upright posture.

Boda, W. L.↗

Cassini tour cost reductions

The original design of the Cassini tour violated the cost constraint for the mission operations and data analysis by more than 30 percent. This challenge was addressed by performing tradeoffs in order to establish a modified risk and performance posture for the operations organization. This new posture accepted more data acquisition risk with minimal impact to the mission objectives, and brought the operation costs to within the program's constraints. The methodology employed within the Cassini program in order to address the tour cost, risk and performance parameters is presented.

Duxbury, J. H.↗

Using Transom Jack in the Human Engineering Analysis of the Materials Science Research Rack-1 and Quench Module Insert

This paper describes the human engineering analysis performed on the Materials Science Research Rack-1 and Quench Module Insert (MSRR-1/QMI) using Transom Jack (Jack) software. The Jack software was used to model a virtual environment consisting of the MSRR-1/QMI hardware configuration and human figures representing the 95th percentile male and 5th percentile female. The purpose of the simulation was to assess the human interfaces in the design for their ability to meet the requirements of the Pressurized Payloads Interface Requirements Document - International Space Program, Revision C (SSP 57000). Jack was used in the evaluation because of its ability to correctly model anthropometric body measurements and the physical behavior of astronauts working in microgravity, which is referred to as the neutral body posture. The Jack model allows evaluation of crewmember interaction with hardware through task simulation including but not limited to collision avoidance behaviors, hand/eye coordination, reach path planning, and automatic grasping to part contours. Specifically, this virtual simulation depicts the human figures performing the QMI installation and check-out, sample cartridge insertion and removal, and gas bottle drawer removal. These tasks were evaluated in terms of adequate clearance in reach envelopes, adequate accessibility in work envelopes, appropriate line of sight in visual envelopes, and accommodation of full size range for male and female stature maneuverability. The results of the human engineering analysis virtual simulation indicate that most of the associated requirements of SSP 57000 were met. However, some hardware design considerations and crew procedures modifications are recommended to improve accessibility, provide an adequate work envelope, reduce awkward body posture, and eliminate permanent protrusions.

Dunn, Mariea C.↗

Use of Human Computer Models to Influence the Design of International Space Station Propulsion Module

The overall design for the International Space Station (ISS) Propulsion (Prop) Module consists of two bell shapes connected by a long tube having a shirt sleeve environment. The tube is to be used by the flight crew to transfer equipment and supplies from the Shuttle to ISS. Due to a desire to use existing space qualified hardware, the tube internal diameter was initially set at 38 inches, while the human engineering specification, NASA-STD-3000, required 50". Human computer modeling using the MannequinPro application was used to help make the case to enlarge the passageway to meet the specification. 3D CAD models of Prop Module were created with 38 inches, 45 inches and 50 inches passageways and human figures in the neutral body posture as well as a fetal posture were inserted into the model and systematically exercised. Results showed that only the 50 inches tube would accommodate a mid tube turn around by a large crew member, 95th percentile American males, by stature.

Hamilton, George S.↗