Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER TRANSMISSION AND DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Implementing Inertial Control for PMSG-WTG in Region 2 Using Virtual Synchronous Generator with Multiple Virtual Rotating Masses

With the increasing integration of renewable energy, the problems associated with a deteriorating grid frequency profile and potential power system instability have become more significant. In this paper, the inertial control algorithm using a virtual synchronous generator (VSG) is implemented on a Type 4 permanent magnet synchronous generator (PMSG) wind turbine generator (WTG). The overall nonlinear dynamic model and its small-signal linearization of the PMSG-WTG using a VSG is established and comprehensively analyzed. Inevitably, the direct application of the VSG introduces a large inertia, which causes conflict between the fast variance of available wind power and inverter control with slow dynamics, particularly in Region 2 of the wind turbine. Aiming to address such issues, a VSG with multiple virtual rotating masses is proposed to improve the active power tracking performance as well as to boost the inertial control of a VSG. The inertial responses are verified in a modified 10-MVA IEEE 14-bus microgrid system. The assessment of the simulation results demonstrates the applicability of the VSG on renewable energy generation units.

17 WIND ENERGY↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Elastomeric load sharing device

An elastomeric load sharing device, interposed in combination between a driven gear and a central drive shaft to facilitate balanced torque distribution in split power transmission systems, includes a cylindrical elastomeric bearing and a plurality of elastomeric bearing pads. The elastomeric bearing and bearing pads comprise one or more layers, each layer including an elastomer having a metal backing strip secured thereto. The elastomeric bearing is configured to have a high radial stiffness and a low torsional stiffness and is operative to radially center the driven gear and to minimize torque transfer through the elastomeric bearing. The bearing pads are configured to have a low radial and torsional stiffness and a high axial stiffness and are operative to compressively transmit torque from the driven gear to the drive shaft. The elastomeric load sharing device has spring rates that compensate for mechanical deviations in the gear train assembly to provide balanced torque distribution between complementary load paths of split power transmission systems.

Isabelle, Charles J.↗

Power System Wildfire Risks and Potential Solutions: A Literature Review & Proposed Metric

Several fire risk evaluation, fire tracking, and fire response resources are available. The risk metrics and fire response programs are sometimes modified to include a power system context. The risk metrics often evaluate the risk of fires causing power system faults or outages, especially on transmission systems. The response programs are modified to ensure the safety of power system equipment and first responders as well as to coordinate power system outages to both ensure safety during an active fire and prevent fire ignition during high risk periods. Although some aspects of wildfire responses have been adapted to include power system concerns, adaptations to power system operations and maintenance to include wildfire risks and responses are still nascent. In particular, a risk metric that evaluates the potential for power system components to ignite wildfires is needed to help guide power system upgrade efforts and power system fire safety measures. This document serves as a brief literature review of wildfire risk metrics and response programs and how they relate to power systems. It also includes a proposed risk metric and structure for describing the risk of a power system component igniting a fire.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of a Reduced-Order Model for IBR Fault Response Representation via OEM Blackbox Models

This paper presents a fully implemented inverter reduced-order-model (ROM) in an EMT simulation (PSCAD) library component for direct user utilization in protection studies. The developed inverter ROM has the following features: Equivalent to a full inverter-based resource (IBR) inverter model with positive- and negative-sequence current formulation and representation. A Python script is developed to fully automate this process, including training data generation, ROM parameter training, updating parameters, and model verification and validation. The ROM is validated using both IEEE 2800-compliant and non-compliant OEM modes in a real-world system, building confidence of its usability by protection engineers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Iterative Response-Surface-Based Approach for Chance-Constrained AC Optimal Power Flow Considering Dependent Uncertainty

A modern power system is characterized by a stochastic variation of the loads and an increasing penetration of renewable energy generation, which results in large uncertainties in its states. These uncertainties bring formidable challenges to the power system planning and operation process. To address these challenges, we propose a cost-effective, iterative response-surface-based approach for the chance-constrained AC optimal power-flow problem that aims to ensure the secure operation of the power systems considering dependent uncertainties. Starting from a stochastic-sampling-based framework, we first utilize the copula theory to simulate the dependence among multivariate uncertain inputs. Then, to reduce the prohibitive computational time required in the traditional Monte-Carlo method, we propose, instead of using the original complicated power-system model, to rely on a polynomial-chaos-based response surface. This response surface allows us to efficiently evaluate the time-consuming power-system model at arbitrary distributed sampled values with a negligible computational cost. This further enables us to efficiently conduct an online stochastic testing for the system states that not only screens out the statistical active constraints, but also assists in a better design of the tightened bounds without using any Gaussian or symmetric assumption. Finally, an iterative procedure is executed to fine-tune the optimal solution that better satisfies a predefined probability. The simulations conducted in multiple test systems demonstrate the excellent performance of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

Sadey, David J.↗

Optimal Power Flow With State Estimation in the Loop for Distribution Networks

Here in this article, we propose a framework for running optimal control-estimation synthesis in distribution networks. Our approach combines a primal-dual gradient-based optimal power flow solver with a state estimation feedback loop based on a limited set of sensors for system monitoring, instead of assuming exact knowledge of all states. The estimation algorithm reduces uncertainty on unmeasured grid states based on certain online state measurements and noisy "pseudomeasurements." We analyze the convergence of the proposed algorithm and quantify the statistical estimation errors based on a weighted least-squares estimator. The numerical results on a 4521-node network demonstrate that this approach can scale to extremely large networks and provide robustness to both large pseudomeasurement variability and inherent sensor measurement noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Scale Grid Models: Synthetic Data and Co-Simulation

Power grid modernization and wide-spread distributed energy resource (DER) integration are driving an explosion of interest in advanced algorithms and new optimization schemes. However, there has historically been a lack of open-access realistically sized and detailed datasets-particularly for the distribution system-and simulation tools able to model these systems. This talk will present recent advances with very large-scale (>>1M nodes) distribution data sets and the use of co-simulation to tractably model large integrated transmission-distribution grids and their interactions with new controls/optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Advanced Synchronized Time Digital Grid Twin Testbed for Relay Misoperation Analysis of Electrical Fault Type Detection Algorithms

Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Layered Coordination Architecture for Resilient Restoration of Power Distribution Systems

The current practices for restoring critical services in the distribution system during a disaster, align with the traditional centralized ideology of distribution systems operations. A central processor evaluates the distribution system after a disruption and attains a restoration plan. However, the centralized operational paradigm is susceptible to single-point failures, requires full situational awareness of the distribution system, and poses scalability challenges for large multifeeder distribution systems. This motivates a distributed decision-making paradigm where multiple agents solve smaller subproblems and jointly coordinate their individual decisions to achieve the global/network-level objective. Toward this goal, we propose a layered architecture for distributed algorithms for resilience and a two-stage distributed algorithm for distribution system restoration. The proposed distributed decision-making framework enables the bottom-up restoration of the distribution system using all available resources, including distributed generation, while only requiring local awareness and limited communications with neighboring connected regions. The proposed framework is robust to single-point failures, enables autonomy using distributed algorithms, and had reduced computational cost compared to centralized optimization solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗