Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diesel Engine Waste Heat Driven Absorption Heat Pumps for ECU Applications in Defense Installations

A thermally activated absorption heat pump suitable for use in naval expeditionary Environmental Control Units, as well as residential space-conditioning, is developed. Waste heat characteristic of the exhaust stream from a diesel engine GenSet is used to drive an absorption cycle to provide cooling. The heat source is coupled to the heat pump using an intermediate fluid loop for flexible deployment. With minor modifications, the heat pump could also provide heating at high coefficients of performance, resulting in versatile functionality. This technology capitalizes on heat and mass transfer enhancement possible in microscale passages to provide a compact architecture for the components and the overall system. The working fluid pair with zero Global Warming Potential is contained within this assembly, reducing fluid inventories significantly over conventional systems. Quiet, reliable, long-life operation due to the absence of a compressor and the use of few moving parts are further critical distinguishing advantages. Modularity in cooling capacity has been demonstrated through scaling-up of component geometry and internal features and dimensions. The core technology was initially demonstrated with a proof-of-concept microscale absorption chiller measuring 200 × 200 × 34 mm and weighing 7 kg that delivered 300 W of cooling in laboratory tests. In the previous BEETIT project, the team made significant advances over the proof-of-concept. System and component designs with > 10× scale-up in capacity were developed, in a packaged unit capable of standalone operation with a semi-autonomous control system. A cooling capacity of 3.5 kW with a COP > 0.5 at an ambient temperature of 35°C was demonstrated for this natural gas-fired unit. Significant cost reductions in fabrication were achieved using low-cost brazing instead of diffusion bonding. In companion projects funded by the Southern Company and the Georgia Research Alliance, stamping and fluid forming techniques were investigated to fabricate microscale features instead of photochemical etching, thereby leading to significant cost reductions. In a follow-on effort funded by ARPA-E and NAVFAC, a 2.7 kW cooling unit was developed to provide cooling at a severe ambient condition of 51.7°C. The unit was driven directly by diesel engine exhaust heat. Innovative finned heat and mass exchangers for the ambient-coupled condenser and absorber were developed. In the present effort, a standalone, packaged and controllable 10.5 kW cooling capacity absorption chiller is developed. This demonstrates a 30× scale up from the proof-of-concept, thus validating the scalability of microchannel heat exchangers for absorption heat pumps. Autonomous operation algorithms demonstrated enhanced dynamic performance. The knowledge from previous projects was leveraged to develop novel component designs that further helped in miniaturizing the heat exchangers. All coupling fluids are hydronically coupled to aid flexible field deployment. The prototype unit provides design cooling capacity at high ambient temperature conditions of 44°C at COP > 0.6.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail sale—a distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

L Prize↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Report

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of subcritical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Autonomous Experimentation for Biological Applications

The Modular Autonomous Research System (MARS) was created to address a key challenge in scientific discovery: experiments are often slow, require significant manual labor, and generate data that is not easily integrated across different tools. This limits how quickly scientists can explore new materials, processes, and chemical reactions. Our motivation was to design a system that makes research faster, more reliable, and adaptable by combining automation with artificial intelligence. By doing so, we aimed to reduce human error, accelerate discovery, and allow researchers to quickly test many possibilities that would otherwise take months or years. Our approach was to build a flexible platform that connects laboratory robots, measurement instruments, and a central data system, all guided by artificial intelligence. MARS integrates liquid handling robots, robotic arms, and plate readers with an intelligent decision-making system that chooses the most informative experiments to run next. This creates a closed loop where experiments are performed automatically, the data is analyzed in real time, and new conditions are immediately tested. Through this work, we demonstrated that MARS can carry out multiple experiments with little or no human intervention, adapt to different scientific problems, and handle uncertain or noisy measurements in a robust way. The results show that modular and intelligent automation can significantly accelerate the pace of discovery, providing a model for future self-driving laboratories. This approach addresses the growing scientific need for adaptable, data-driven research platforms that can keep up with the complexity and scale of modern science.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement techniques of thermoelectric devices and modules

Thermoelectric (TE) energy conversion devices are designed based on measured material transport properties. Although an ideal device efficiency can be calculated using the figure of merit, zT, the actual efficiency of a thermoelectric module is smaller and must be measured. TE device performance testing techniques and procedures are reviewed with a focus on energy conversion efficiency. One of the areas that attract less attention in the literature is the transition from basic thermoelectric materials research to the production of modules and devices. The effects of interface layers, diffusion barriers, thermal insulations, and heat sinks are reviewed. Finally, device performance from single couples to standard modules and long-term reliability are discussed.

Wang, Hsin↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration of NMR porosity to estimate permeability in carbonate reservoirs

Considering the performance of carbon dioxide (CO 2 ) stored in geologic reservoirs requires some knowledge of the subsurface heterogeneity, where the most reliable data is extracted from wellbore measurements. This benefit is especially true for carbonate reservoirs were reactions between supercritical CO 2 , the reservoir brine, and carbonate minerals create new storage capacity and enhanced permeability. Techniques like NMR well logging hold promise for estimating subsurface permeability, because the total porosity and pore size can be calculated from response of 1 H NMR signal. Resulting depth profiles of porosity and permeability from downhole logs are useful input for reservoir simulations and can be used to design injection protocols and estimate storage capacity. We conducted a detailed characterization study to quantify the NMR response to matrix pore space, the connectivity to larger vugs and fractures, and the resulting permeability of core samples from distinct carbonate formations. The cores used in study span 5 orders in permeability, 4 orders in mean T 2 , and 2%–42% in porosity. The goal of the study was to use independent measures of pore volumes, surface relaxivity, fluid-accessible surface areas, and permeability to develop carbonate permeability models. It was not possible to develop a single model that reproduced permeability for different carbonate formations, because phenomena specific to the reservoirs could not be extracted even with the state-of-the-art characterization techniques used in this study. Estimates of permeability require calibration. Best calculations for a given formation were achieved by using a simple form of the Kozeny equation (Eq. 6): κ=Α’θ 3*n , and calibrating A’ and n with laboratory measurements made on the formation cores. Empirical calibrations can then be used to map the vertical heterogeneity of the storage complex to better understand the physical movement CO 2 and brine in the subsurface and the positive feedback between mineral dissolution and the development of flow pathways.

54 ENVIRONMENTAL SCIENCES↗

Versatile Test Reactor Conceptual Core Design

The VTR is a 300-MW(thermal) sodium-cooled fast reactor (SFR) designed for the specific purpose of delivering unique testing capabilities to enable the advancement of all reactor technologies. With its flux level, irradiation volume, and operational flexibility, the VTR will enable accelerated testing of materials, fuels, and various components needing irradiation testing. Proven SFR technologies and design approaches have been leveraged in designing the VTR core, ensuring the highest possible readiness level. This resulted in the VTR using ternary metallic fuel and delivering fast flux levels in excess of 4 x 10 15 n/cm 2 ∙ s over large useful volumes, corresponding to about 60 dpa/year in steel. As part of the design efforts, the VTR core performance has been determined for a representative configuration, ensuring that the reactivity control systems offer sufficient shutdown margins, that the core can be safely cooled in all situations, and that reactivity feedback coefficients are conducive to a favorable safety behavior. Furthermore, the incorporation of features such as fuel assembly storage in the shield region supports the flexible and reliable operation of the VTR. Additional design work has been ongoing as well. This includes thorough shielding performance evaluations to ensure safe operation of the VTR, verification and validation of the design tools used to achieve compliance with Nuclear Quality Assurance (NQA-1) requirements, early assessment of the impact of irradiation experiments on the core performance envelope and associated margins, and in-depth uncertainty quantification efforts to quantify the anticipated range of performance characteristics. An experimental program supporting the VTR core design has been set up, with the current focus being on thermal-hydraulic experiments. The purpose of this experimental program is to obtain confirmatory measurements to serve directly as part of the core design basis or as part of the validation cases supporting the simulation tools used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concentric Ring Gas Atomization Die Design for Optimized Particle Production

In partnership with Linde plc (formerly Praxair, Inc.), Ames Laboratory will further develop and commercialize its concentric-ring high pressure gas atomization (CR-HPGA) gas-die technology with a goal to improve the precision of metal powder production in a desired size range and quality. The successful commercialization of this technology could reduce production cost of metal powders and improve reliability of this industrial process, increasing specialty alloy powder availability for new applications and adoption into additive manufacturing and multiple materials sectors. The project scope is to [1] utilize AMES compressible gas flow and melt break-up models to explore a wide swath of parameter space available for the CR-HPGA technology, identifying the most promising gas-die designs for fabrication, [2] verify and optimize the new gas-die design, fabricate it and select preferred operating parameters by gas-only flow imaging and aspiration pressure measurements, down-selecting gas compositions and atomization parameters for full scale testing, [3] perform pilot-scale atomization trials with Al and/or Cu alloys of a new CR-HPGA gas-die at selected parameters, [4] evaluate gas-die performance by comparing resulting powder size distribution and powder quality attributes with equivalent powders made by conventional close-coupled HPGA technology, and [5] assess (through Praxair partnership) reduction in operational costs of new CR-HPGA gas-die through the use of an inert gas recovery/recycling system. In partnership with Praxair, Inc., the team, led by Ames Laboratory senior metallurgist Iver Anderson, intend to demonstrate the performance of an optimized CR-HPGA gas-die design in a pilot scale atomizer and better understand the design and operational controls to increase overall benefits for precision metal powder production.

42 ENGINEERING↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators that sense energy depositions in the substrate through a transient shift in their resonant frequency. In this work, I installed new devices in the QUIET cryogenic facility and used a network analyzer to drive them across a range of power levels. At each setting, I measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. Despite the increased noise at low power, the model consistently captured the resonance behavior. I first measured the resonance parameters as a function of RF drive power, then repeated the measurement across a range of temperatures to test whether the device behaved like an MKID. While the notch-filter fits captured the resonance reliably, the observed temperature dependence did not match the expected MKID signature — indicating that these first in-house fabricated chips are not yet functioning as true MKIDs. Overall, this reframes our work as a study of resonance parameter extraction and identification, pointing towards future iterations of device design and fabrication to get the true MKID response.

Savitala, Akash [U. Washington, Seattle (main); Fe↗

The Elusive “Life” of LEDs: How TM-21 Contributes to the Solution

This magazine article discusses the issue of LED 'lifetime' and explains where TM-21 plays as part of the solution to this issue. In August 2011, the Illuminating Engineering Society (IES) published the TM-21 document entitled 'Lumen degradation lifetime estimation method for LED light sources.' TM-21 is the IES-recommended method for projecting lumen degradation of an LED package, array or module based on data collected according to LM-80. The lighting community expects TM-21 to become the standard method for projecting useful LED lighting product life at realistic operating temperature. This article presents the development process behind TM-21, and clarifies how and when to apply the lifetime extrapolation method to arrive at reasonable and useful estimations. Why TM-21 and why now? We are all familiar with the very real but sometimes exaggerated long-life attributes of LED technology. Not the least of these is the potential for very long life that helps make it an attractive design choice. The trick has been and continues to be how to measure or estimate this longevity to provide assurance to users of this technology's reliability (life) compared to other options. We also understand that the overall reliability of a complete LED lighting fixture can be affected by the reliability of individual product components (driver, lens, etc.) and should be accounted for in lifetime estimations. The useful life of standard lighting technologies is defined as the time to filament or cathode failure. For most of these lamps, the time period prior to failure exhibits acceptable levels of light output, as shown with the solid lines in Fig. 1. This makes it easy to determine when to replace the lamp. However, LEDs do not have filament burn-out that conveniently announces the end of life (dashed line in Fig. 1). Further, the rapid development of the technology and the desire to bring products to market in a timely manner does not allow for actual testing verification of the long lives claimed (100,000 or even 35,000 hours). As a result, the industry has come to accept a definition of the end of the useful life of an LED as the point when it no longer provides a specified level of light output. And finally, the life and performance of LED lighting products depends greatly on excess heat retained at the diode. This is why LEDs require testing at multiple temperatures such that when a source is installed in a luminaire, its actual operating temperature can be measured and lumen depreciation of the product can be derived. Therefore, to serve the solid-state lighting industry, the Technical Procedures Committee (TPC) of the IES proceeded to develop appropriate tests for use in rating LED product longevity. The initial need was a measure of the basic lumen degradation of LED source components identified by a module, package, or array of diodes and this came in the form of LM-80. Importantly, LM-80 only specifies how to measure lumen depreciation to a minimum of 6000 hours (but recommends testing to 10,000 hours or longer). LM-80 stops short of using that data to estimate any depreciation after that, which is where TM-21 comes in. The TM-21 working group (WG) as part of the IES TPC was formed to develop the lumen depreciation projection method and spent over three years exploring many options. The WG evaluated various projection options starting with an analysis of various mathematical, engineering-based models to provide effective depreciation fit and a useful projection method. Next, the WG analyzed LED lumen maintenance behavior using over 40 sets of LM-80-08 test data (20 sets with 10,000 hours or more) collected from four major LED manufacturers. The working group also examined the accuracy of proposed projections using various proposed models and LM-80 data that extended up to 15,000 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultrasonic High-Temperature Sensors: Past Experiments and Prospects for Future Use

Ultrasonic thermometry sensors (UTS) have been intensively studied in the past to measure temperatures from 2080 to 3380 K. This sensor, which uses the temperature dependence of acoustic velocity in materials, was developed for experiments in extreme environments. Its major advantages, which are (a) recording capability of a temperature profile deduced from the notches on the sensor rod and (b) measurement near the sensor material melting point, can be of great interest when dealing with on-line monitoring of high temperature safety tests. Ultrasonic techniques were successfully applied in several severe accident related experiments. If new developments are conducted with other materials, this sensor type may be used in a wide-range of experimental areas where robustness and compactness are required. Long-term irradiation experiments of nuclear fuel to extremely high burn-ups could benefit from this previous experience. After an overview of UTS technology, this paper summarizes experimental work performed to improve the reliability of these sensors. The various designs, advantages and drawbacks are outlined and future prospects for long term high temperature irradiation experiments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Parameter Estimation with Physics-based Neural Ordinary Differential Equations

Accurate estimation of dynamic parameters of gen-erators is crucial to building a reliable model for dynamical studies and reliable operation of the power system. This paper develops a physics-based neural ordinary differential equations (ODE) approach to learn the parameters of generator dynamic model using phasor measurement units (PMU) data. We design a physics-based neural network to represent the swing equations of the power system dynamics. A loss function is defined as the difference between dynamic simulation results from the physics-based neural networks and pseudo PMU measurements. The parameters of generator dynamic model are iteratively updated using the neural ODEs and the adjoint method. By exploiting the mini-batch scheme in neural ODE training, the parameter estimation performance is significantly improved. Numerical study results on a 3-machine 9-bus system show that the proposed algorithm outperforms state-of-the-art baseline method in both computation time and dynamic parameter estimation accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy

Purpose: Entrance dose (or skin dose) is an important part of patient quality assurance in external beam radiation therapy. However, entrance dose verification in proton beam is not routinely performed. In this study, the OneDose single use MOSFET detector system for in vivo dosimetry measurement in proton therapy is investigated. Methods: Using a solid water phantom, several fundamental dosimetric characteristics of the OneDose system are studied with a proton beam: The reproducibility (consistency) of the dosimeter, the linearity with dose and dose rate, energy dependence, directional dependence, LET dependence, and fading (delay readout with time) is studied. Results: OneDose detectors show dose and dose rate linearity but exhibit pronounced energy dependence at depth and a large variation in dose response with LET. On the other hand, the detector response remain relatively constant (within 3%) at surface over a wide range of energies. There is also a slight angular dependence (about 2%) up to 60 deg. angle of incidence. However, detector orientation such that incidence along the long axis of the detector should be avoided as the proton beam will have to traverse a large amount of the copper backing. Since most in vivo dosimetry involves entrance dose measurement, the OneDose at surface appears to be well suited for such application. OneDose exhibits small intrabatch variation ({<=}2% at one SD) indicating that it is only necessary to calibration a few detectors from each batch. The interbatch variation is generally within 3%. Conclusions: The small detector size and its relatively flexible design of OneDose allow dose measurement to be performed on a curved surface or in small cavities that is otherwise difficult with the conventional diode detectors. The slight drawback in its angular dependence can be easily handled by angular dependence table. However, since OneDose is a single use detector, the intrabatch consistency must be verified before the remaining detectors from the same batch could be used for in vivo dosimetry. It is advisable that the detectors from the same batch be taken for the same application to reduce the dosimetric uncertainty. For detectors from different batches, interbatch consistency should also be verified to obtain reliable results. OneDose provides an opportunity to measure in vivo dose with proton beam within acceptable clinical criterion of {+-}(5.0%-6.5%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next-Generation Performance-Based Regulation. Volume 1: Introduction - Global Lessons for Success; Volume 2: Primer - Essential Elements of Design and Implementation; Volume 3: Innovative Examples from Around the World

Performance-based regulations (PBRs) provide a regulatory framework to connect goals, targets, and measures to utility performance or executive compensation. Well-designed PBRs provide incentives for utility performance, benefiting consumers and utility owners alike. This report considers the role of both PBRs and more discrete performance incentive mechanisms (PIMs) in 21st century power sector transformation. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. PBRs have the potential to realign utility, investor, and consumer incentives and mitigate emerging challenges to the utility business model, renewable integration, and even cyber security.The goals of PBRs in the form of multi-year rate plans are in many respects the same in terms of providing reasonably priced and reliable service to customers. However, today's technologies have changed, and there is more emphasis on clean energy. Thus, the pathways and the potential outcomes are different than they were in the 20th century when centralized generator stations and large infrastructure additions dominated the utility landscape. Given unprecedented changes underway in the electricity sector, PBRs - by specifying expectations of utility performance and outcomes for consumers, while staying agnostic to the exact means of delivery - constitute a form of prescient regulation that harnesses disruption. PBRs are one tool in a broader toolbox in the transition toward flexible regulatory and market structures that rewards utilities that adapt or evolve in reaction to market and technology change. PBRs and PIMs have great value for the electric industry when designed well and can be applied to many different situations. How exactly PBR mechanisms are most effectively enacted will vary based on the utility ownership model, institutional arrangements, and a variety of other local factors. PBRs should be tailored to the needs and goals of each jurisdiction, and perhaps each utility, to most effectively achieve the needs of a 21st century power grid in that jurisdiction. Presented in three volumes, this report highlights the lessons learned from their evolving history, explores essential elements of their design and implementation as well as considerations for how they may be best applied, and examines leading examples of PBRs from the United Kingdom, New York, Denmark, Mexico, and South Africa. The full report, 'Next-Generation Performance Based Regulation - Emphasizing Utility Performance to Unleash Power Sector Innovation,' published in September 2017, can be accessed at https://www.nrel.gov/docs/fy17osti/68512.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗