Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Frequency Responsive Demand in U.S. Western Power System Model

Frequency control from the demand side presents a novel and viable way to complement control by traditional generators. This paper presents simulation tests of a previously developed load controller in a large interconnected system model. The controller was implemented as a user defined model in PowerWorld software. WECC system model was used. The simulation tests include comparison of situation with and without control, sensitivities to controller location, control gain parameters, and type of end-use loads. The performance is measured in terms of frequency and intertie power flow deviations after a large generator outage.

Power system dynamics, power system control↗

WE-G-BRA-01: Patient Safety and Treatment Quality Improvement Through Incident Learning: Experience of a Non-Academic Proton Therapy Center

Purpose: Incident learning has been proven to improve patient safety and treatment quality in conventional radiation therapy. However, its application in proton therapy has not been reported yet to our knowledge. In this study, we report our experience in developing and implementation of an in-house incident learning system. Methods: An incident learning system was developed based on published principles and tailored for our clinical practice and available resource about 18 months ago. The system includes four layers of error detection and report: 1) dosimetry peer review; 2) physicist plan quality assurance (QA); 3) treatment delivery issue on call and record; and 4) other incident report. The first two layers of QA and report were mandatory for each treatment plan through easy-to-use spreadsheets that are only accessible by the dosimetry and physicist departments. The treatment delivery issues were recorded case by case by the on call physicist. All other incidents were reported through an online incident report system, which can be anonymous. The incident report includes near misses on planning and delivery, process deviation, machine issues, work flow and documentation. Periodic incident reviews were performed. Results: In total, about 116 errors were reported through dosimetry review, 137 errors through plan QA, 83 treatment issues through physics on call record, and 30 through the online incident report. Only 8 incidents (2.2%) were considered to have a clinical impact to patients, and the rest of errors were either detected before reaching patients or had negligible dosimetric impact (<5% dose variance). Personnel training & process improvements were implemented upon periodic incident review. Conclusion: An incident learning system can be helpful in personnel training, error reduction, and patient safety and treatment quality improvement. The system needs to be catered for each clinic’s practice and available resources. Incident and knowledge sharing among proton centers are encouraged.

60 APPLIED LIFE SCIENCES↗

Searches for anomalous coupling in top-quark interaction with the W boson and b quark, along with searches for quark-flavor-changing neutral currents, in an analysis of data from the CMS experiment

The results of searches for effects beyond the Standard Model in processes of single top-quark production in the CMS experiment are presented. Anomalous contributions of the vector and magnetic types in top-quark interaction with the W boson and b quark and quark-flavor-changing neutral currents in top-quark interaction with the c or u quark via gluon exchange were studied. The respective analysis was performed with the aid of Bayesian neural networks. No statistically significant deviations were found, and upper limits on anomalous couplings at a 95% confidence level were set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of the Y (4140) structure in the J/ψΦ mass spectrum in B±→ J/ψΦK ± decays

Here, the observation of the $Y(4140)$ structure in $B^\pm\rightarrow J/\psi\,\phi K^\pm$ decays produced in $\bar{p} p $ collisions at $\sqrt{s}=1.96~TeV$ is reported with a statistical significance greater than 5 standard deviations. A fit to the $J/\psi\,\phi$ mass spectrum is performed assuming the presence of a Breit-Wigner resonance. The fit yields a signal of $19^{+6}_{-5}$ resonance events, and resonance mass and width of $4143.4^{+2.9}_{-3.0}(\mathrm{stat})\pm0.6(\mathrm{syst}) ~MeVcc$ and $15.3^{+10.4}_{-6.1}(\mathrm{stat})\pm2.5(\mathrm{syst})~MeVcc$ respectively. The parameters of this resonance-like structure are consistent with values reported from an earlier CDF analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Do Machine Learning Approaches Offer Skill Improvement for Short-Term Forecasting of Wind Gust Occurrence and Magnitude?

Abstract Wind gusts, and in particular intense gusts, are societally relevant but extremely challenging to forecast. This study systematically assesses the skill enhancement that can be achieved using artificial neural networks (ANNs) for forecasting of wind gust occurrence and magnitude. Geophysical predictors from the ERA5 reanalysis are used in conjunction with an autoregressive term in regression and ANN models with different predictors, and varying model complexity. Models are derived and assessed for the warm (April–September) and cold (October–March) seasons for three high passenger volume airports in the United States. Model uncertainty is assessed by deriving models for 1000 different randomly selected training (70%) and testing (30%) subsets. Gust prediction fidelity in independent test samples is critically dependent on inclusion of an autoregressive term. Gust occurrence probabilities derived using five-layer ANNs exhibit consistently higher fidelity than those from regression models and shallower ANNs. Inclusion of the autoregressive term and increasing the number of hidden layers in ANNs from 1 to 5 also improve the model performance for gust magnitudes (lower RMSE, increased correlation, and model standard deviations that more closely approximate observed values). Deeper ANNs (e.g., 20 hidden layers) exhibit higher skill in forecasting strong (17–25.7 m s −1 ) and damaging (≥25.7 m s −1 ) wind gusts. However, such deep networks exhibit evidence of overfitting and still substantially underestimate (by 50%) the frequency of strong and damaging wind gusts at the three airports considered herein. Significance Statement Improved short-term forecasting of wind gusts will enhance aviation safety and logistics and may offer other societal benefits. Here we present a rigorous investigation of the relative skill of models of wind gust occurrence and magnitude that employ different statistical methods. It is shown that artificial neural networks (ANNs) offer considerable skill enhancement over regression methods, particularly for strong and damaging wind gusts. For wind gust magnitudes in particular, application of deeper learning networks (e.g., five or more hidden layers) offers tangible improvements in forecast accuracy. However, deeper networks are vulnerable to overfitting and exhibit substantial variability with the specific training and testing data subset used. Also, even deep ANNs reproduce only half of strong and damaging wind gusts. These results indicate the need for future work to elucidate the dynamical mechanisms of intense wind gusts and advance solutions to their prediction.

54 ENVIRONMENTAL SCIENCES↗

Top anti-top Asymmetries at the Tevatron and the LHC

The heaviest known elementary particle today, the top quark, has been discovered in 1995 by the CDF and D0 collaborations at the Tevatron proton antiproton collider at Fermilab. Recently, the CDF and D0 collaborations have studied the forward-backward asymmetry in ttbar events, resulting in measured values larger than the standard model prediction. With the start of the LHC at CERN in 2010, a new top quark factory has opened and asymmetry measurements in ttbar have also been performed in a proton proton environment with higher collision energy. No deviations from the standard model have been noticed so far in the measurements of ATLAS and CMS. This article discusses recent results of asymmetry measurements in ttbar events of the ATLAS, CDF, CMS and D0 collaborations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the Representativity of Electrode Microstructure Parameters and Their Electrochemical Response for Lithium Ion Batteries

Lithium-ion battery electrochemical models require an accurate description of the electrodes microstructures to be predictive that can be achieved through nanoscale imaging. Such observations are however limited by their field of view (FOV), as they provide only a subset of the whole electrode volume that does not necessarily represent the whole electrode microstructure heterogeneity, and therefore can bias the microstructure analysis. A microstructure scale electrochemical model was used to investigate lithium plating onset, material non-uniform utilization, and in-plane heterogeneities for an NMC-graphite full cell. To evaluate the representativeness, and thus relevance, of these model predictions, a coupled representativity analysis has been performed on the microstructure parameters and, in a novel way, on the full cell electrochemical response. Electrode microstructure parameters representativeness has been first quantified using the representative volume element (RVE) methodology. The RVE major flaw is that ultimately it can only conclude if a FOV contains representative subvolumes of the FOV, but not if the FOV itself is representative of the electrode volume. Analysis can conclude negatively ('FOV is not representative'), but not positively ('FOV is representative'). One major contribution of this work was to quantify the convergence of the RVE size with the FOV, to actually investigate the FOV representativeness and thus partly remedy this intrinsic limitation. The analysis determined that performing a standard RVE calculation, without exploring its FOV convergence, is likely to strongly underestimate the actual RVE size. The new RVE methodology has been automated in the NREL open-source Microstructure Analysis Toolbox (MATBOX) and is available to the battery community. Representativeness of microstructure parameters is however only an intermediate step, as the end-results of an electrochemical model are performances predictions. Indeed, what is the practical consequence of a given deviation for a microstructure parameter? The microstructure parameter deviation propagations to the 3D microstructure scale electrochemical response have been then quantified for different charge rates. This defines a threshold for the microstructure parameters FOV for a desired maximum deviation of the electrochemical response. Such deviation propagation analysis is analogous to error propagation analysis and is necessary to determine the relevance of microstructure scale model predictions for macroscale predictions. Electrochemical model shows cell representative section areas are increasing with C-rate, due to higher in-plane heterogeneities, indicating larger FOVs are required specifically for fast charge modeling. Therefore, we introduced the novel concept of electrochemical RVE (eRVE) that is a function of the operating conditions (thus defined as a dynamic RVE), with an increasing dependence with the C-rate. Representativity analysis of the investigated cell determined a FOV of 144.4 x 54.4 m2 is large enough to establish a convergence on the representative section areas for low to intermediate C-rate (=2.5C), but not large enough to conclude for higher rates. This work aims to emphasize the importance of representativity analysis for LIB electrode microstructures, as it is required to estimate the error, and thus the relevance, of microstructure parameters intended to be used in macroscale models. The methodology and results can help researchers to select the relevant imaging and associated FOV required to provide accurate enough microstructure parameters.

ADVANCED PROPULSION SYSTEMS↗

Shock compression response of highly reactive Ni + Al multilayered thin foils

The shock-compression response of Ni + Al multilayered thin foils is investigated using laser-accelerated thin-foil plate-impact experiments over the pressure range of 2 to 11 GPa. The foils contain alternating Ni and Al layers (parallel but not flat) of nominally 50 nm bilayer spacing. The goal is to determine the equation of state and shock-induced reactivity of these highly reactive fully dense thin-foil materials. The laser-accelerated thin-foil impact set-up involved combined use of photon-doppler-velocimetry to monitor the acceleration and impact velocity of an aluminum flyer, and VISAR interferometry was used to monitor the back free-surface velocity of the impacted Ni + Al multilayered target. The shock-compression response of the Ni + Al target foils was determined using experimentally measured parameters and impedance matching approach, with error bars identified considering systematic and experimental errors. Meso-scale CTH shock simulations were performed using real imported microstructures of the cross-sections of the multilayered Ni + Al foils to compute the Hugoniot response (assuming no reaction) for correlation with their experimentally determined equation of state. It was observed that at particle velocities below ∼150 m/s, the experimentally determined equation of state trend matches the CTH-predicted inert response and is consistent with the observed unreacted state of the recovered Ni + Al target foils from this velocity regime. At higher particle velocities, the experimentally determined equation of state deviates from the CTH-predicted inert response. A complete and self-sustained reaction is also seen in targets recovered from experiments performed at these higher particle velocities. The deviation in the measured equation of state, to higher shock speeds and expanded volumes, combined with the observation of complete reaction in the recovered multilayered foils, confirmed via microstructure characterization, is indicative of the occurrence of shock-induced chemical reaction occurring in the time-scale of the high-pressure state. TEM characterization of recovered shock-compressed (unreacted) Ni + Al multilayered foils exhibits distinct features of constituent mixing revealing jetted layers and inter-mixed regions. These features were primarily observed in the proximity of the undulations present in the alternating layers of the Ni + Al starting foils, suggesting the important role of such instabilities in promoting shock-induced intermetallic-forming reactions in the fully dense highly exothermic multilayered thin foils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory

Here, we report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80(o) and energies in excess of 4 EeV (4 × 10 18 eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional information on any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured, while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p-values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10 -5 in the case of the angular power spectrum, and 2.5 × 10 -3 in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Techniques For Real-time Anomaly Detection Using Spark Over Multi-source VMware Performance Data

Anomaly detection refers to the identi cation of an irregular or unusual pat- tern which deviates from what is standard, normal, or expected. Such deviated patterns typically correspond to samples of interest and are assigned different labels in different domains, such as outliers, anomalies, exceptions, or malware. Detecting anomalies in fast, voluminous streams of data is a formidable chal- lenge. This paper presents a novel, generic, real-time distributed anomaly detection framework for heterogeneous streaming data where anomalies appear as a group. We have developed a distributed statistical approach to build a model and later use it to detect anomaly. As a case study, we investigate group anomaly de- tection for a VMware-based cloud data center, which maintains a large number of virtual machines (VMs). We have built our framework using Apache Spark to get higher throughput and lower data processing time on streaming data. We have developed a window-based statistical anomaly detection technique to detect anomalies that appear sporadically. We then relaxed this constraint with higher accuracy by implementing a cluster-based technique to detect sporadic and continuous anomalies. We conclude that our cluster-based technique out- performs other statistical techniques with higher accuracy and lower processing time.

Apache Spark↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Anomalies in the Magnetic Susceptibility in the Second-Order Phase Transitions beyond the Curie Point

Taking into account the inexhaustible interest in studying the peculiarities of physical properties in the neighborhood of phase transitions and the growth of experimental investigations of cobalt fluoride, we have studied the peculiarities of magnetic susceptibility in the vicinity of the critical field H{sub C} at which cobalt fluoride performs the second-order phase transition from the antiferromagnetic phase to the angular phase. It is discovered that in the magnetic field H ‖ C{sub 4}, the magnetic susceptibility becomes infinite at H → H{sub C}. It is shown that as the magnetic field direction deviates from the C{sub 4} axis, the magnetic susceptibility in the critical field H{sub C} proves to be finite. It is also shown that the change in the magnetic susceptibility with the change in the magnetic field considerably decreases at extremely insignificant deviations of the field H from the C{sub 4} axis. Since the calculations are performed in terms of the Landau theory of phase transitions, we pay attention to the similarity and difference between the obtained results and those in the vicinity of the Curie point obtained by using the Landau theory of phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Communication: Water on hexagonal boron nitride from diffusion Monte Carlo

Despite a recent flurry of experimental and simulation studies, an accurate estimate of the interaction strength of water molecules with hexagonal boron nitride is lacking. Here, we report quantum Monte Carlo results for the adsorption of a water monomer on a periodic hexagonal boron nitride sheet, which yield a water monomer interaction energy of −84 ± 5 meV. We use the results to evaluate the performance of several widely used density functional theory (DFT) exchange correlation functionals and find that they all deviate substantially. Differences in interaction energies between different adsorption sites are however better reproduced by DFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Spot characteristic stability for proton pencil beam scanning

Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

FIRM image analysis: A machine learning workflow for quantifying extracellular matrix components from electron microscopy images

The extracellular matrix (ECM) is a complex network of biomolecules that plays an integral role in the structure, processes, and signaling mechanisms of cells and tissues. Identifying and quantifying changes in these matrix components provides insight into the mechanisms behind specific tissue remodeling processes; however, quantifying these changes is challenging due to difficult imaging conditions, complexity of the ECM, and the subtlety of these changes. Current imaging techniques allow us to visualize these critical remodeling events and developments in image analysis have employed a combination of analysis software and machine learning techniques to improve the efficiency and accuracy with which features are measured. Although image analysis has seen much improvement in recent years, there has been no technique developed to address ambiguity in feature edges in electron microscopy images. Presented here is a new machine learning-based workflow for the analysis of microscopy images named FIRM (Feature Identification from Raw Microscopy) that uses a random forest classifier to identify ECM features of interest and generate binary segmentation masks for quantification with ImageJ-FIJI. FIRM performed with an F1 score of 0.794 and greater than 80% accuracy for number and size of features detected. FIRM had similar deviation from the ground truth in the number of identified fibrils, fibril size, and size distributions when compared to human analyses. The results suggest that FIRM performs as well as manual analysis and requires a fraction of the time. This analysis technique is more efficient, eliminates user bias, and can be easily optimized to identify a variety of features, making it useful for any discipline requiring image analysis.

Science & Technology - Other Topics↗