Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Device Engineering Towards Improved Tin Sulfide Solar Cell Performance and Performance Reproducibility

As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to rapidly test promising candidates in high-performing PV devices. There is a need to engineer new compatible device architectures, including the development of novel transparent conductive oxides and buffer layers. Here, we consider the two approaches of a substrate-style and a superstrate-style device architecture for novel thin-film solar cells. We use tin sulfide as a test absorber material. Upon device engineering, we demonstrate new approaches to improve device performance and performance reproducibility.

14 SOLAR ENERGY↗

Performance and breakdown characteristics of irradiated vertical power GaN P-i-N diodes

Electrical performance and defect characterization of vertical GaN P-i-N diodes before and after irradiation with 2.5 MeV protons and neutrons is investigated. Devices exhibit increase in specific on-resistance following irradiation with protons and neutrons, indicating displacement damage introduces defects into the p-GaN and n- drift regions of the device that impact on-state device performance. The breakdown voltage of these devices, initially above 1700 V, is observed to decrease only slightly for particle fluence <; 10 13 cm -2 . Furthermore, the unipolar figure of merit for power devices indicates that while the on-resistance and breakdown voltage degrade with irradiation, vertical GaN P-i-Ns remain superior to the performance of the best available, unirradiated silicon devices and on-par with unirradiated modern SiC-based power devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the ATLAS muon trigger in pp collisions at √s = 8 TeV

The performance of the ATLAS muon trigger system is evaluated with proton–proton collision data collected in 2012 at the Large Hadron Collider at a centre-of-mass energy of 8 TeV. It is primarily evaluated using events containing a pair of muons from the decay of Z bosons. The efficiency of the single-muon trigger is measured for muons with transverse momentum 25 < p T < 100 GeV, with a statistical uncertainty of less than 0.01 % and a systematic uncertainty of 0.6 %. The pT range for efficiency determination is extended by using muons from decays of J/ψ mesons, W bosons, and top quarks. The muon trigger shows highly uniform and stable performance. Thus, the performance is compared to the prediction of a detailed simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and performance of the ATLAS Tile Calorimeter in Run 1

The Tile Calorimeter is the hadron calorimeter covering the central region of the ATLAS experiment at the Large Hadron Collider. Approximately 10,000 photomultipliers collect light from scintillating tiles acting as the active material sandwiched between slabs of steel absorber. This paper gives an overview of the calorimeter’s performance during the years 2008–2012 using cosmic-ray muon events and proton–proton collision data at centre-of-mass energies of 7 and 8 TeV with a total integrated luminosity of nearly 30 fb –1 . The signal reconstruction methods, calibration systems as well as the detector operation status are presented. The energy and time calibration methods performed excellently, resulting in good stability of the calorimeter response under varying conditions during the LHC Run 1. Lastly, the Tile Calorimeter response to isolated muons and hadrons as well as to jets from proton–proton collisions is presented. The results demonstrate excellent performance in accord with specifications mentioned in the Technical Design Report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HACC: extreme scaling and performance across diverse architectures, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Supercomputing is evolving towards hybrid and accelerator-based architectures with millions of cores. The HACC (Hardware/Hybrid Accelerated Cosmology Code) framework exploits this diverse landscape at the largest scales of problem size, obtaining high scalability and sustained performance. Developed to satisfy the science requirements of cosmological surveys, HACC melds particle and grid methods using a novel algorithmic structure that flexibly maps across architectures, including CPU/GPU, multi/many-core, and Blue Gene systems. We demonstrate the success of HACC on two very different machines, the CPU/GPU system Titan and the BG/Q systems Sequoia and Mira, attaining unprecedented levels of scalable performance. We demonstrate strong and weak scaling on Titan, obtaining up to 99.2% parallel efficiency, evolving 1.1 trillion particles. On Sequoia, we reach 13.94 PFlops (69.2% of peak) and 90% parallel efficiency on 1,572,864 cores, with 3.6 trillion particles, the largest cosmological benchmark yet performed. HACC design concepts are applicable to several other supercomputer applications.

Computer Science↗

Fuel cell performance of palladium-platinum core-shell electrocatalysts synthesized in gram-scale batches

This article presents the performance of palladium-platinum core-shell catalysts (Pt/Pd/C) for oxygen reduction synthesized in gram-scale batches in both liquid cells and polymer-electrolyte membrane fuel cells. Core-shell catalyst synthesis and characterization, ink fabrication, and cell assembly details are discussed. The Pt mass activity of the Pt/Pd core-shell catalyst was 0.95 A mg –1 at 0.9 V measured in liquid cells (0.1 M HClO4), which was 4.8 times higher than a commercial Pt/C catalyst. The performances of Pt/Pd/C and Pt/C in large single cells (315 cm 2 ) were assessed under various operating conditions. The core-shell catalyst showed consistently higher performance than commercial Pt/C in fuel cell testing. A 20–60 mV improvement across the whole current density range was observed on air. Sensitivities to temperature, humidity, and gas composition were also investigated and the core-shell catalyst showed a consistent benefit over Pt under all conditions. However, the 4.8 times activity enhancement predicated by liquid cell measurements was not fully realized in fuel cells.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

pbd-industrial-limit-of-performance (PBD limit of performance) v1.0.0

Software repository that contains models used for a paper about Platform-Based Design with limit of performance analysis for an industrial pilot study. This repository contains process and control models in Modelica and IDAES and scripts to develop an ML based controller that computes the control function that maximizes the techno-economic performance of cost and energy computed by the model. This software is meant to be released to reproduce the work described in a Journal publication that is now drafted with the working title "Energy System Limit of Performance Analysis using an Online Machine Learning Multi-Resolution Optimization Framework".

Amusat, Oluwamayowa [Lawrence Berkeley National La↗

High-performance conjugate-gradient benchmark: A new metric for ranking high-performance computing systems

Here, we describe a new high-performance conjugate-gradient (HPCG) benchmark. HPCG is composed of computations and data-access patterns commonly found in scientific applications. HPCG strives for a better correlation to existing codes from the computational science domain and to be representative of their performance. Furthermore, HPCG is meant to help drive the computer system design and implementation in directions that will better impact future performance improvement.

97 MATHEMATICS AND COMPUTING↗

A performance model for the communication in fast multipole methods on high-performance computing platforms

Exascale systems are predicted to have approximately 1 billion cores, assuming gigahertz cores. Limitations on affordable network topologies for distributed memory systems of such massive scale bring new challenges to the currently dominant parallel programing model. Currently, there are many efforts to evaluate the hardware and software bottlenecks of exascale designs. It is therefore of interest to model application performance and to understand what changes need to be made to ensure extrapolated scalability. The fast multipole method (FMM) was originally developed for accelerating N-body problems in astrophysics and molecular dynamics but has recently been extended to a wider range of problems. Its high arithmetic intensity combined with its linear complexity and asynchronous communication patterns make it a promising algorithm for exascale systems. In this paper, we discuss the challenges for FMM on current parallel computers and future exascale architectures, with a focus on internode communication. We focus on the communication part only; the efficiency of the computational kernels are beyond the scope of the present study. We develop a performance model that considers the communication patterns of the FMM and observe a good match between our model and the actual communication time on four high-performance computing (HPC) systems, when latency, bandwidth, network topology, and multicore penalties are all taken into account. To our knowledge, this is the first formal characterization of internode communication in FMM that validates the model against actual measurements of communication time. The ultimate communication model is predictive in an absolute sense; however, on complex systems, this objective is often out of reach or of a difficulty out of proportion to its benefit when there exists a simpler model that is inexpensive and sufficient to guide coding decisions leading to improved scaling. The current model provides such guidance.

Computer Science↗

Flexspander: augmenting expander networks in high-performance systems with optical bandwidth steering

Communication efficiency is one of the deciding factors in determining many of today’s high-performance computing (HPC) applications. Traditionally, HPC systems have been on static network topologies, making them inflexible to the variety of skewed traffic demands that may arise due to the spatial locality inherent in many applications. To handle traffic locality, researchers have proposed integrating optical circuit switches (OCSs) into the network architecture, which reconfigures the network topology to alter and dynamically adapt to the predicted traffic. In this paper, we present a novel reconfigurable network topology called Flexspander. Beyond offering a flexible interconnect, Flexspander also offers full flexibility in terms of construction and can be built with any arbitrary combination of commercial electrical packet switches and OCSs. We evaluate Flexspander performance through extensive simulations with multiple network traces, and our results show improved performance for Flexspander over currently proposed static and reconfigurable topologies in terms of the flow completion time.

Teh, Min Yee↗

Energy Efficiency and Conservation Block Grant (EECBG) - Better Buildings Neighborhood Program at Greater Cincinnati Energy Alliance: Home Performance with Energy Star® and Better Buildings Performance

The Greater Cincinnati Energy Alliance (Energy Alliance) is a nonprofit economic development agency dedicated to helping Greater Cincinnati and Northern Kentucky communities reduce energy consumption. The Energy Alliance has launched programs to educate homeowners, commercial property owners, and nonprofit organizations about energy efficiency opportunities they can use to drive energy use reductions and financial savings, while extending significant focus to creating/retaining jobs through these programs. The mission of the Energy Alliance is based on the premise that investment in energy efficiency can lead to transformative economic development in a region. With support from seven municipalities, the Energy Alliance began operation in early 2010 and has been among the fastest growing nonprofit organizations in the Greater Cincinnati/Northern Kentucky area. The Energy Alliance offers two programs endorsed by the Department of Energy: the Home Performance with ENERGY STAR® Program for homeowners and the Better Buildings Performance Program for commercial entities. Both programs couple expert guidance, project management, and education in energy efficiency best practices with incentives and innovative energy efficiency financing to help building owners effectively invest in the energy efficiency, comfort, health, longevity, and environmental impact of their residential or commercial buildings. The Energy Alliance has raised over $23 million of public and private capital to build a robust market for energy efficiency investment. Of the $23 million, $17 million was a direct grant from the Department of Energy Better Buildings Neighborhood Program (BBNP). The organization’s investments in energy efficiency projects in the residential and commercial sector have led to well over $50 million in direct economic activity and created over 375,000 hours of labor created or retained. In addition, over 250 workers have been trained through the Building Performance Training Center, a program that was developed and funded by the Energy Alliance and housed at Cincinnati State Technical and Community College. Nearly 100 residential and commercial contractors currently participate in the Energy Alliance’s two major programs, which have together served over 2,800 residential and 100 commercial customers. Additionally, the Energy Alliance established loan programs for homeowners, nonprofits and commercial businesses. The GC-HELP program was established to provide up to ten year low interest, unsecured loans to homeowners to cover the energy efficiency products they purchased through the Energy Alliance approved contractor base. To date the Energy Alliance has financed over $1 million in energy efficiency loans for homeowners, without any loans written off. The nonprofit business community is offered five year, fixed-interest rate loans through the Building Communities Loan Fund of $250,000. Additionally, the Energy Alliance has developed GC-PACE, a commercial financing tool that enables buildings owners to finance their energy upgrades through voluntary property assessments deploying low-interest extended-term capital from the bond market. The Energy Alliance and its partners are actively evaluating additional market-based financing solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing Commercial Real Estate Owner and Investor Data to Analyze the Financial Performance of Energy Efficient, High-Performance Office Buildings

Evidence has shown that owning and operating energy-efficient, high-performance, “green” properties results in multiple benefits including lower utility bills, higher rents, improved occupancy, and greater net operating income. However, it is difficult to isolate and control moderating factors to identify the specific drivers behind improved financial performance and value to investors that results from sustainability in real estate. DOE is interested in facilitating deeper investigation of the correlation between energy efficiency and financial performance, reducing data acquisition and matching challenges, and developing a stronger understanding of how sustainable design and energy efficiency impact value. DOE commissioned this pilot study to test the logistical and empirical procedures required to establish a Commercial Real Estate Data Aggregation & Trends Analysis lab, determine the potential benefits available through the lab, and contribute to the existing body of evidence in this field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Cold-air performance of free power turbine designed for 112-kilowatt automotive gas-turbine engine. 2: Effects of variable stator-vane-chord setting angle on turbine performance

The cold-air performance of an axial-flow power turbine with a variable stator designed for a 112-kW automotive gas-turbine engine was determined at speeds from 30 to 110 percent of design and at pressure ratios from 1.11 to 2.67. Performance is presented in terms of equivalent mass flow, torque, power, and efficiency for stator-vane-chord setting angles of 26 degs, 30 degs, 35 degs (design), 40 degs, 45 degs, and 50 degs. Turbine braking performance at a nominal stator setting angle of 107 degs is also presented. Turbine efficiency increased with increasing stator setting angle. A 10-point efficiency increase was obtained by opening the stator from the design setting angle of 35 degs to a setting angle of 45 degs.

Mclallin, K. L.↗

Cold-air performance of compressor-drive turbine of Department of Energy upgraded automobile gas turbine engine. 2: Stage performance

The aerodynamic performance of the compressor-drive turbine of the DOE upgraded gas turbine engine was determined in low temperature air. The as-received cast rotor blading had a significantly thicker profile than design and a fairly rough surface finish. Because of these blading imperfections a series of stage tests with modified rotors were made. These included the as-cast rotor, a reduced-roughness rotor, and a rotor with blades thinned to near design. Significant performance changes were measured. Tests were also made to determine the effect of Reynolds number on the turbine performance. Comparisons are made between this turbine and the compressor-drive turbine of the DOE baseline gas turbine engine.

Roelke, R. J.↗

Investigation of hand capabilities under a variety of performance conditions and an attempt to explain performance differences

Human capabilities such as dexterity, manipulability, and tactile perception are unique and render the hands as a very versatile, effective and a multipurpose tool. This is especially true for environments such as the EVA environment. However, with the use of the protective EVA gloves, there is much evidence to suggest that human performance decreases. In order to determine the nature and cause of this performance decrement, several performance tests were run which studied the effects of gloves on strength, tactile feedback, and range of motion. Tactile sensitivity was measured as a function of grip strength, and the results are discussed. Equipment which was developed to measure finger range of motion along with corresponding finger strength values is discussed. The results of these studies have useful implications for improved glove design.

Bishu, Ram R.↗