At least 307 records · Page 17

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Microwave Heating-Induced Temperature Gradients in Liquid–Liquid Biphasic Systems

Microwaves (MWs) can enable the electrification and intensification of chemical manufacturing. They have been applied to various unit separations, such as drying, distillation, and extraction, entailing gas–liquid and solid–liquid systems. However, a limited quantitative understanding of MW-heated liquid–liquid biphasic systems related to extraction exists. This work measures the temporal and spatial temperature difference between an aqueous and an organic phase in batch and continuous microfluidic modes. We demonstrate permanent temperature differences between phases over 35 °C and spatiotemporal periodic and quasiperiodic oscillations modulated by the flow patterns. The temperature differences are primarily driven by the faster absorption rate of MW irradiation by the aqueous phase versus the slower heat transfer from the aqueous phase to the organic phase. These are amplified by low specific interfacial area and modifications of the electromagnetic field. We employ a multiphysics model to predict the temperature difference in a batch system. The model is in good agreement with the experiments. We demonstrate a strong effect of input power, dielectric properties of organic solvents, the volume of solvents, and the volume ratio between phases on the temperature difference. A simple analytical model describes the temperature difference and provides design principles. Furthermore, the combined approach offers new insights into the design and optimization of the MW-heated biphasic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Higher-order particle representation for particle-in-cell simulations

In this paper we present an alternative approach to the representation of simulation particles for unstructured electrostatic and electromagnetic PIC simulations. In our modified PIC algorithm we represent particles as having a smooth shape function limited by some specified finite radius, r 0 . A unique feature of our approach is the representation of this shape by surrounding simulation particles with a set of virtual particles with delta shape, with fixed offsets and weights derived from Gaussian quadrature rules and the value of r 0 . As the virtual particles are purely computational, they provide the additional benefit of increasing the arithmetic intensity of traditionally memory bound particle kernels. The modified algorithm is implemented within Sandia National Laboratories' unstructured EMPIRE-PIC code, for electrostatic and electromagnetic simulations, using periodic boundary conditions. We show results for a representative set of benchmark problems, including electron orbit, a transverse electromagnetic wave propagating through a plasma, numerical heating, and a plasma slab expansion. In this work, good error reduction across all of the chosen problems is achieved as the particles are made progressively smoother, with the optimal particle radius appearing to be problem-dependent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An introduction to Spent Nuclear Fuel decay heat for Light Water Reactors: a review from the NEA WPNCS

This paper summarized the efforts performed to understand decay heat estimation from existing spent nuclear fuel (SNF), under the auspices of the Working Party on Nuclear Criticality Safety (WPNCS) of the OECD Nuclear Energy Agency. Needs for precise estimations are related to safety, cost, and optimization of SNF handling, storage, and repository. The physical origins of decay heat (a more correct denomination would be decay power) are then introduced, to identify its main contributors (fission products and actinides) and time-dependent evolution. Due to limited absolute prediction capabilities, experimental information is crucial; measurement facilities and methods are then presented, highlighting both their relevance and our need for maintaining the unique current full-scale facility and developing new ones. The third part of this report is dedicated to the computational aspect of the decay heat estimation: calculation methods, codes, and validation. Different approaches and implementations currently exist for these three aspects, directly impacting our capabilities to predict decay heat and to inform decision-makers. Finally, recommendations from the expert community are proposed, potentially guiding future experimental and computational developments. One of the most important outcomes of this work is the consensus among participants on the need to reduce biases and uncertainties for the estimated SNF decay heat. If it is agreed that uncertainties (being one standard deviation) are on average small (less than a few percent), they still substantially impact various applications when one needs to consider up to three standard deviations, thus covering more than 95% of cases. The second main finding is the need of new decay heat measurements and validation for cases corresponding to more modern fuel characteristics: higher initial enrichment, higher average burnup, as well as shorter and longer cooling time. Similar needs exist for fuel types without public experimental data, such as MOX, VVER, or CANDU fuels. A third outcome is related to SNF assemblies for which no direct validation can be performed, representing the vast majority of cases (due to the large number of SNF assemblies currently stored, or too short or too long cooling periods of interest). A few solutions are possible, depending on the application. For the final repository, systematic measurements of quantities related to decay heat can be performed, such as neutron or gamma emission. This would provide indications of the SNF decay heat at the time of encapsulation. For other applications (short- or long-term cooling), the community would benefit from applying consistent and accepted recommendations on calculation methods, for both decay heat and uncertainties. This would improve the understanding of the results and make comparisons easier.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatial and temporal variation in forest transpiration across a forested boreal peatland complex

Transpiration is a globally important component of evapotranspiration. Careful upscaling of transpiration from point measurements is thus crucial for quantifying water and energy fluxes. In spatially heterogeneous landscapes common across the boreal biome, upscaled transpiration estimates are difficult to determine due to variation in local environmental conditions (e.g., basal area, soil moisture, permafrost). Here, we sought to determine stand-level attributes that influence transpiration scalars for a forested boreal peatland complex consisting of sparsely treed wetlands and densely treed permafrost plateaus as land cover types. The objectives were to quantify spatial and temporal variability in stand-level transpiration, and to identify sources of uncertainty when scaling point measurements to the stand-level. Using heat ratio method sap flow sensors, we determined sap velocity for black spruce and tamarack for 2-week periods during peak growing season in 2013, 2017 and 2018. We found greater basal area, drier soils, and the presence of permafrost increased daily sap velocity in individual trees, suggesting that local environmental conditions are important in dictating sap velocity. When sap velocity was scaled to stand-level transpiration using gridded 20 × 20 m resolution data across the ~10 ha Scotty Creek ForestGEO plot, we observed significant differences in daily plot transpiration among years (0.17–0.30 mm), and across land cover types. Daily transpiration was lowest in grid-cells with sparsely treed wetlands compared to grid-cells with well-drained and densely treed permafrost plateaus, where daily transpiration reached 0.80 mm, or 30% of the daily evapotranspiration. When transpiration scalars (i.e., sap velocity) were not specific to the different land cover types (i.e., permafrost plateaus and wetlands), scaled stand-level transpiration was overestimated by 42%. To quantify the relative contribution of tree transpiration to ecosystem evapotranspiration, we recommend that sampling designs stratify across local environmental conditions to accurately represent variation associated with land cover types, especially with different hydrological functioning as encountered in rapidly thawing boreal peatland complexes.

54 ENVIRONMENTAL SCIENCES↗

A worldwide aerosol phenomenology: Elemental and organic carbon in PM 2.5 and PM 10

Elemental carbon (EC), organic carbon (OC), and particulate matter (PM) concentrations in the inhalable (PM 10 ) and fine (PM 2.5 ) size fractions are measured worldwide, albeit with different analytical methods. These measurements from many researchers were collected and analyzed for Africa, America, Asia, and Europe for 2012–2019. EC/PM, OC/PM, and OC/EC ratios were examined based on region, site type, and season to infer potential sources and impacts. These analyses demonstrate that carbonaceous materials are important PM constituents throughout the world. Mean EC/PM ratios were lowest in PM 10 in Sahelian Africa and Europe (∼0.01), highest (>0.07) in PM 2.5 at urban sites in North America, South America, and Japan. Mean OC/PM ratios were lowest in PM 10 in the Sahel (∼0.06) and in PM 2.5 in China and Thailand (0.10), and highest in central and eastern Europe (∼0.3) and North America (∼0.4). OC/EC ratios were elevated in western and northern Europe, and at regional background sites in North America. EC/PM increased with PM 10 in Thailand, while OC/PM increased with higher PM mass in Thailand, India, and North America, highlighting the specific contribution of carbonaceous aerosols to PM pollution in these regions. At European and North American background sites, OC/EC ratios increased with PM mass. Higher OC/EC ratios in dry periods indicate influence of wildfires, prescribed burns, and secondary aerosol formation. Elevated wintertime EC/PM ratios coincide with residential heating in temperate climate zones.

54 ENVIRONMENTAL SCIENCES↗

Comparing the cooling effectiveness of operationalisable urban surface combination scenarios for summer heat mitigation

Extreme summer heat in cities exacerbates the vulnerability of urban communities to heatwaves. Vegetative and reflective urban surfaces can help reduce urban heat. This study investigated the impacts of urban trees, green roofs and cool roofs on heat mitigation during average and extreme summer conditions in temperate oceanic Melbourne, Australia. We simulated the city climate using ‘The Air Pollution Model’ (TAPM) at a 1 km spatial resolution over 10 years, which according to our review of the literature, was the most prolonged period for simulation in Melbourne. During a widespread heatwave event, some of the tested scenarios with combined surface parameters could reduce the extreme values of the energy budget components- sensible heat, latent heat, and storage heat fluxes up to seasonal averages compared to the existing situation for Melbourne (control). The scenario with the highest (reasonable maximum) ground-level vegetation, green roofs, and cool roofs could reduce air temperatures up to 2.4 °C. The simulations suggest that a combined strategy with vegetative and high-albedo surfaces will deliver higher effectiveness with maximum cooling benefits and cost-effectiveness than individual strategies in cities. These results suggest the importance of collaborative strategic planning of urban surfaces to make cities healthier, sustainable, and liveable.

54 ENVIRONMENTAL SCIENCES↗

The Role of Regional Connections in Planning for Future Power System Operations Under Climate Extremes

Identifying the sensitivity of future power systems to climate extremes must consider the concurrent effects of changing climate and evolving power systems. We investigated the sensitivity of a Western U.S. power system to isolated and combined heat and drought when it has low (5%) and moderate (31%) variable renewable energy shares, representing historic and future systems. We used an electricity operational model combined with a model of historically extreme drought (for hydropower and freshwater-reliant thermoelectric generators) over the Western U.S. and a synthetic, regionally extreme heat event in Southern California (for thermoelectric generators and electricity load). We found that the drought has the highest impact on summertime production cost (+10% to +12%), while temperature-based deratings have minimal effect (at most +1%). The Southern California heat wave scenario impacting load increases summertime regional net imports to Southern California by 10-14%, while the drought decreases them by 6-12%. Combined heat and drought conditions have a moderate effect on imports to Southern California (-2%) in the historic system and a stronger effect (+8%) in the future system. Southern California dependence on other regions decreases in the summertime with the moderate increase in variable renewable energy (-34% imports), but hourly peak regional imports are maintained under those infrastructure changes. By combining synthetic and historically driven conditions to test two infrastructures, we consolidate the importance of considering compounded heat wave and drought in planning studies and suggest that region-to-region energy transfers during peak periods are key to optimal operations under climate extremes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Atmospheric Rivers on Alaskan River Ice

Atmospheric rivers (ARs) transport vast amounts of moisture from low to high latitude regions. One region particularly impacted by ARs is Interior Alaska (AK). We analyze the impact of ARs on the annual river ice breakup date for 26 locations in AK. We investigate the AR-driven rise in local air temperatures and explore the relationship between ARs and precipitation, including extremes and interannual variability. We found that AR events lead to an increase in local air temperatures for over 1 week (by ≈ 1 °C). ARs account for 40% of total precipitation, explain 47% of precipitation variability, and make up 59% of extreme precipitation events, each year. By estimating the heat transfer between winter precipitation and the river ice surface, we conclude that increased precipitation during the coldest period of the year delays river ice breakup dates, while precipitation occurring close to the breakup date has little impact on breakup timing.

54 ENVIRONMENTAL SCIENCES↗

Multipacting analysis of the SNS drift tube linac (DTL) RF vacuum window using Spark3d

An ongoing study at the Spallation Neutron Source (SNS) seeks to better understand and address potential multipacting issues associated with the Drift Tube Linac (DTL) RF vacuum windows. An analysis of several failed operational windows showed indications of excessive RF heating on the TiN-coated alumina ceramics. Coupled with vacuum bursts and arcing during conditioning and/or operational periods, these problems have been attributed to electron activity likely caused by multipacting. The status of the study, 3-D electromagnetic simulation results, mitigating techniques and a future experimental plan for studying multipacting in the SNS DTL vacuum windows are presented.

Toby, George↗

A multi-dimensional dataset for two-phase instability in low pressure natural circulation based on direct transient local measurement

Thermal hydraulic instability can challenge the control and the safety of nuclear reactors. This experimental research captures and investigates the instability in a low-pressure (1–10 atmospheres) natural circulation loop with an adiabatic chimney installed above the heated section. Direct transient local measurement of two-phase flow is performed at multiple axial locations along the flow channel with thermocouples and conductivity probes traversed by customized high-precision mechanisms. Based on the periodicity of oscillations, a post-processing method is proposed to align the data captured non-simultaneously to reconstruct the instability behavior in one representative period. The averaging operation over multiple oscillation cycles is performed to reduce the random errors. Cyclic phenomena are clearly demonstrated by the post-processed data, and rapid void fraction change induced by the flashing is observed to be significant in the driving mechanism for low pressure oscillations. Parametric effects of inlet subcooling, heat flux, inlet flow restriction and system pressure are studied within the experiment range, and qualitative results are explained and compared with existing literature. The ratio between the oscillation period and the travelling time of the fluid particle through the test section is compared with the theoretical value for the density wave oscillation. The new dataset contains directly measured transient multi-dimensional two-phase data along the flow channel for natural circulation under density wave oscillations. The generated dataset is valuable for the validation of system analysis codes and CFD codes in the simulation of natural circulation phenomena and dynamic two-phase flow.

42 ENGINEERING↗

Evolution of ELMs, pedestal profiles and fluctuations in the inter-ELM period in NBI and ECH dominated discharges in DIII-D

In DIII-D, it has been observed that ELM frequency decreases by 40% and ELM spacing becomes more regular in time when heating is changed from pure neutral beam injection (NBI) to predominantly electron cyclotron heating (ECH) in ITER Similar Shape plasmas. In comparison with pure the NBI discharges, pedestal fluctuations in magnetics and density increase in the ECH dominated discharges. Recovery of the pedestal profiles like electron density (ne), temperature (Te) and pressure (pe) shows marked differences for these two heating schemes. Average profiles in the last 30% of the ELM cycle shows higher Te, lower ne, and similar pe at the pedestal top for the ECH discharge when compared to the NBI discharge. Here, the gradient of Te (∇Te) is also steeper at the pedestal in the ECH discharge. Magnetic fluctuations show 3 distinct modes in 13~116 kHz in the ECH discharges only. ne fluctuations show two modes evolving in the inter-ELM period of the ECH discharge, a low frequency (400 kHz) quasi-coherent mode (LFQC) and high frequency (~2 MHz) broadband (HFB) fluctuations. Evolution of these modes has marked correspondence with the inter-ELM ∇Te recovery. A sharp decrease in the Dα baseline is observed whenever the LFQC weakens and the HFB grows, prior to each large ELM. Transport coefficients obtained from TRANSP shows that MTM and/or TEM are plausible candidates for the observed fluctuations. Linear gyrofluid simulation (TGLF) corroborates this characterization. TGLF shows that the linear growth rate of the most dominant mode peaks at ion-scale (kθρs ~ 0.4) at the pedestal steep gradient and the frequency is in the electron diamagnetic direction. It is proposed that increased fluctuations in the ECH dominated case, due to increased ∇Te, caused an increase in fluctuation-driven transport in the pedestal and slowed the pedestal recovery between ELMs, leading to a reduction in the ELM frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty in Atlantic Multidecadal Oscillation derived from different observed datasets and their possible causes

As a leading mode of sea surface temperature (SST) variability over the North Atlantic in both observations and model simulations, the Atlantic Multidecadal Oscillation (AMO) can have a substantial influence on regional and global climate. By using Low-Frequency Component Analysis, we explore the uncertainties of the resulting AMO indices and the corresponding spatial patterns derived from three observational SST datasets. We found that the known coherent spatial pattern of the AMO at the basin scale over the North Atlantic appears in two out of the three datasets. Further analysis indicates that both the warming trend and the different techniques used to construct these observed gridded SSTs contribute to the AMO’s spatial coherence over the North Atlantic, especially during periods of sparse data sampling. The SST in the Extended Reconstructed SST dataset version 5 (ERSSTv5), changes from being systematically below the other datasets during the dense sampling periods on either side of the Second World War (WWII), to systematically above the other datasets during WWII, thereby introducing an artificial 10–20-year variability that affects the AMO’s spatial coherence. This coherence in the AMO’s spatial pattern is also affected by bias adjustment in ERSSTv5 at relative cool (i.e., non-summer) seasons, and by the heterogeneous North Atlantic warming pattern. The different AMO patterns can induce the different effects of wind, surface heat fluxes, and then drive ocean circulation and its heat transport convergence, especially for some seasons. For AMO indices, both the different detrending methods and different observational data result in uncertainty for the period 1935–1950. Such SST uncertainty is important to detect the relative role of the atmosphere and ocean in shaping the AMO.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Modeling of Triply Periodic Minimal Surface (TPMS) Structures with RELAP5-3D

This poster goes over preliminary work performed on modeling triply periodic minimal surfaces (TPMS) with RELAP5-3D. The poster starts off with the need for advanced nuclear fuel designs for future reactors, and how TPMS are being researched for this purpose. There is then a focus on what a TPMS is and then moves onto the motivation for why this geometry is being modeled and looked into. The methodology is then shown for how data from different experiments will be used for pre-test predictions and eventual creation of empirical coefficients and multipliers to be used in models. Then there is a show of how data would be compared between the experimental tests, CFD, and RELAP5-3D values. The results from the simulations and comparisons are then presented to show how the CFD and RELAP5-3D compare to each other currently, with no experimental data to compare to for one test model. Results from the second test model are also presented to show that there is stability in the solving of that model.

42 - ENGINEERING↗

Pulsed laminar falling films in vertical tubes: Maintaining a continuous liquid film with reduced film thickness

Falling-liquid-film heat transfer is important to a wide variety of industrial applications, including two-phase thermosyphons, falling-film evaporators in the food industry, heat exchangers in fuel-ethanol processing, and the chemical service industry. Particularly for laminar falling films, the heat transfer increases as the film thickness decreases, hence it is desirable to keep the films as thin as possible. This article presents a periodically-pulsed flow concept to reduce the average mass flow inside a vertical tube. The technique provides thinner films than can be achieved with continuous flow. A drainage model is adopted to predict the film thickness as a function of flow rate and location along the tube. The concept is confirmed experimentally by measuring the film thickness in real time in a circular tube using a laser-based absorption technique. A new heat-transfer-based film continuity measurement is also integrated into the optical film measurement setup. Water at ambient temperature and pressure is used for this work. Film thickness reductions of up to 60%, and liquid-film volume-flow reductions of up to 80% compared to the minimum continuous-flow film have been obtained. The time-varying film thickness profile can also be controlled to a limited extent, which may be of interest for process industries.

42 ENGINEERING↗

Equatorial Origin of the Observed Tropical Pacific Quasi-Decadal Variability From ENSO Nonlinearity

Quasi-decadal (QD) climate variability is detected in the tropical Pacific based on the recent 70 years of observations. This QD variability is identified in equatorial sea surface temperatures (SSTs), the pattern of which resembles the Central Pacific (CP) El Niño-Southern Oscillation (ENSO) but extends further meridionally to the northeastern subtropical Pacific. Whereas equatorial upper-ocean heat content and SSTs are in quadrature for ENSO, these two quantities are almost in phase on the QD timescale. Further analysis shows that nonlinear dynamical heating, primarily originating from strong El Niño events, tends to lead QD SSTs by a quarter of its dominant period (approximately 30 months) and shapes the dominant QD periodicity in observations. Here, our results suggest that the observed QD variability largely originates from ENSO nonlinearity and thus is fundamentally different from ENSO's oscillatory nature.

54 ENVIRONMENTAL SCIENCES↗

Assessing residential PM 2.5 concentrations and infiltration factors with high spatiotemporal resolution using crowdsourced sensors

Building conditions, outdoor climate, and human behavior influence residential concentrations of fine particulate matter (PM 2.5 ). To study PM 2.5 spatiotemporal variability in residences, we acquired paired indoor and outdoor PM 2.5 measurements at 3,977 residences across the United States totaling >10,000 monitor-years of time-resolved data (10-min resolution) from the PurpleAir network. Time-series analysis and statistical modeling apportioned residential PM 2.5 concentrations to outdoor sources (median residential contribution = 52% of total, coefficient of variation = 69%), episodic indoor emission events such as cooking (28%, CV = 210%) and persistent indoor sources (20%, CV = 112%). Residences in the temperate marine climate zone experienced higher infiltration factors, consistent with expectations for more time with open windows in milder climates. Likewise, for all climate zones, infiltration factors were highest in summer and lowest in winter, decreasing by approximately half in most climate zones. Large outdoor–indoor temperature differences were associated with lower infiltration factors, suggesting particle losses from active filtration occurred during heating and cooling. Absolute contributions from both outdoor and indoor sources increased during wildfire events. Infiltration factors decreased during periods of high outdoor PM 2.5 , such as during wildfires, reducing potential exposures from outdoor-origin particles but increasing potential exposures to indoor-origin particles. Time-of-day analysis reveals that episodic emission events are most frequent during mealtimes as well as on holidays (Thanksgiving and Christmas), indicating that cooking-related activities are a strong episodic emission source of indoor PM 2.5 in monitored residences.

54 ENVIRONMENTAL SCIENCES↗