Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Automated piezoresponse force microscopy domain tracking during fast thermally stimulated phase transition in CuInP 2 S 6

Real-time tracking of dynamic nanoscale processes such as phase transitions by scanning probe microscopy is a challenging task, typically requiring extensive and laborious human supervision. Smart strategies to track specific regions of interest (ROI) in the system during such transformations in a fast and automated manner are necessary to study the evolution of the microscopic changes in such dynamic systems. In this work, we realize automated ROI tracking in piezoresponse force microscopy during a fast (≈0.8 °C s –1 ) thermally stimulated ferroelectric-to-paraelectric phase transition in CuInP 2 S 6 . We use a combination of fast (1 frame per second) sparse scanning with compressed sensing image reconstruction and real-time offset correction via phase cross correlation. The applied methodology enables in situ fast and automated functional nanoscale characterization of a certain ROI during external stimulation that generates sample drift and changes local functionality.

36 MATERIALS SCIENCE↗

Thermal imaging of plasma with a phased array antenna in QUEST

A thermal imaging system to measure plasma Electron Bernstein Emission (EBE) emanating from the mode conversion region in overdense plasma is discussed. Unlike conventional ECE/EBE imaging, this diagnostics does not employ any active mechanical scanning mirrors or focusing optics to scan for the emission cones in plasma. Instead, a standard 3 × 3 waveguide array antenna is used as a passive receiver to collect emission from plasma and imaging reconstruction is done by accurate measurements of phase and intensity of these signals by heterodyne detection technique. A broadband noise source simulating the EBE, is installed near the expected mode conversion region and its position is successfully reconstructed using phase array technique which is done in post processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inter fractional variability of breathing phase definition as determined by fiducial location

Reconstruction of four-dimensional (4D) imaging typically requires an externally measurable surrogate to represent the real-time relative phase of respiration. A common method is to use a reflective marker on the external surface of the patient which moves with respiration and can be tracked in real time. The location of the marker is often chosen to maximize the observable motion, though this location may not be at the region of interest. We evaluate the importance of infrared (IR) marker placement location on breathing phase definition for the purpose of respiratory gating and 4D computed tomography (CT) image reconstruction. Data were collected for ten patients enrolled on an approved IRB protocol. Real-time position data were collected during CT imaging and daily treatments for two external IR reflective markers: one placed near the xyphoid and another at the approximate location of the treatment isocenter. Motion traces from the markers were compared using cross-correlation coefficient and by estimating the relative respiratory phase, based on either marker, as would be used for 4D-CT reconstruction. Cross-correlation analysis revealed differences in the motion waveform, as well as phase differences, both of which were variable between patients as well as day to day for the same patient. Estimated relative phases from each marker were compared by the percentage amount of time the estimated phase for each marker was different, binned based on increments of 10% of a full cycle. For all collected data combined, the frequency with which breathing phase mismatch led to different bin allocation in steps of 10% was as follows: T{sub 010%}=65.1%, T{sub 1020%}=25.3%, T{sub 2030%}=7.8%, T{sub 3040%}=1.5% and T{sub 4050%}=0.4%. Based on ten images per cycle, this indicates that 4D reconstructions would be influenced, depending on which marker was used, by at least 1 bin 34.9% of the time. This number was noticeably higher for some patients; the maximum was 71% of the time for one patient of ten. In conclusion, the respiratory amplitude and relative phase depend significantly on the location of the IR marker used to monitor respiration. For some patients the xyphoid and isocentric markers may be completely out of phase. More importantly, this relationship varies day to day, suggesting that a single marker may be inadequate for the purposes of respiratory gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Orbit tomography of energetic particle distribution functions

Both fast ions and runaway electrons are described by distribution functions, the understanding of which are of critical importance for the success of future fusion devices such as ITER. Typically, energetic particle diagnostics are only sensitive to a limited subsection of the energetic particle phase-space which is often insufficient for model validation. However, previous publications show that multiple measurements of a single spatially localized volume can be used to reconstruct a distribution function of the energetic particle velocity-space by using the diagnostics' velocity-space weight functions, i.e. velocity-space Tomography. In this work we use the recently formulated orbit weight functions to remove the restriction of spatially localized measurements and present orbit tomography, which is used to reconstruct the 3D phase-space distribution of all energetic particle orbits in the plasma. Through a transformation of the orbit distribution, the full energetic particle distribution function can be determined in the standard {energy, pitch, r, z}-space. We benchmark the technique by reconstructing the fast-ion distribution function of an MHD-quiescent DIII-D discharge using synthetic and experimental FIDA measurements. We also use the method to study the redistribution of fast ions during a sawtooth crash at ASDEX upgrade using FIDA measurements. Lastly, a comparison between the orbit tomography and velocity-space tomography is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as well as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.

1D nanostructures↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

Sparse matrix wavefront reconstruction: simulations and experiments

Adaptive optics systems with Shack-Hartmann wavefront sensors require reconstruction of the atmospheric phase error from slope measurements, with every sensor in the array being used in the computation of each actuator command. This fully populated reconstruction matrix can result in a significant computational burden for adaptive optics systems with large numbers of actuators. A method for generating sparse wavefront reconstruction matrices for adaptive optics isproposed. The method exploits the relevance of nearby slope measurements for control of an individual actuator, and relies upon the limited extent of the influence function for a zonal deformable mirror. Relying only on nearby sensor information can significantly reduce the calculation time for wavefront reconstruction. In addition, a hierarchic controller is proposed to recover some of the global wavefront information. The performance of these sparse wavefront reconstruction matrices was evaluated in simulation, and tested on the Palomar Adaptive Optics System. This paper will present some initial results from the simulations and experiments.

space↗

Bench top interferometric test bed for LISA

Adaptive optics systems with Shack-Hartmann wavefront sensors require reconstruction of the atmospheric phase error from slope measurements, with every sensor in the array being used in the computation of each actuator command. This fully populated reconstruction matrix can result in a significant computational burden for adaptive optics systems with large numbers of actuators. A method for generating sparse wavefront reconstruction matrices for adaptive optics is proposed. The method exploits the relevance of nearby slope measurements for control of an individual actuator, and relies upon the limited extent of the influence function for a zonal deformable mirror. Relying only on nearby sensor information can significantly reduce the calculation time for wavefront reconstruction. In addition, a hierarchic controller is proposed to recover some of the global wavefront information. The performance of these sparse wavefront reconstruction matrices was evaluated in simulation, and tested on the Palomar Adaptive Optics System. This paper will present some initial results from the simulations and experiments.

LISA↗

Enhanced 4D cone-beam CT with inter-phase motion model

Four-dimensional (4D) cone-beam CT (CBCT) is commonly obtained by respiratory phase binning of the projections, followed by independent reconstructions of the rebinned data in each phase bin. Due to the significantly reduced number of projections per reconstruction, the quality of the 4DCBCT images is often degraded by view-aliasing artifacts easily seen in the axial view. Acquisitions using multiple gantry rotations or slow gantry rotation can increase the number of projections and substantially improve the 4D images. However, the extra cost of the scan time may set fundamental limits to their applications in clinics. Improving the trade-off between image quality and scan time is the key to making 4D onboard imaging practical and more useful. In this article, we present a novel technique toward high-quality 4DCBCT imaging without prolonging the acquisition time, referred to as the 'enhanced 4DCBCT'. The method correlates the data in different phase bins and integrates the internal motion into the 4DCBCT image formulation. Several strategies of the motion derivation are discussed, and the resultant images are assessed with numerical simulations as well as a clinical case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

Precursor dependent nucleation and growth of ruthenium films during chemical vapor deposition

Nucleation and film growth characteristics are reported during chemical vapor deposition of Ru on SiO{sub 2} using triruthenium dodecacarbonyl [Ru{sub 3}(CO){sub 12}] and ruthenium bis(di-t-butylacetamidinate) dicarbonyl [Ru({sup t}Bu-Me-amd){sub 2}(CO){sub 2}]. Films grown from Ru{sub 3}(CO){sub 12} follow the three dimensional (3D) Volmer–Weber growth mode. In contrast, films grown from Ru({sup t}Bu-Me-amd){sub 2}(CO){sub 2} follow the pseudo-layer-by-layer growth mode with two dimensional wetting layer islands forming before 3D particle growth is observed on the islands. A relationship between free isolated hydroxyl [(Si-OH){sub i}] group density and Ru nucleation density is found for Ru{sub 3}(CO){sub 12} and is associated with (Si-OH){sub i} acting as the reaction sites for activation of Ru{sub 3}(CO){sub 12} and in turn generating an adjustable adatom concentration. Carbon monoxide and ammonia addition to the gas phase during film growth from Ru({sup t}Bu-Me-amd){sub 2}(CO){sub 2} lead to smoother films by inducing surface reconstructions during the 3D phase of pseudo-layer-by-layer growth; these gases also lead to films with lower resistivity and lower crystalline character.

42 ENGINEERING↗

Polychromatic cone-beam phase-contrast tomography

A method is presented for quantitative phase-contrast tomography using unfiltered radiation from a small polychromatic source. The three-dimensional distribution of complex refractive index in a monomorphous object is reconstructed given a single projection image per view angle. The reconstruction algorithm is achromatic and stable with respect to high-spatial-frequency noise, in contrast to conventional tomography. The density distribution in a test sample was accurately reconstructed from polychromatic phase-contrast data collected with a point-projection x-ray microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗

Atomic Resolution Imaging of Halide Perovskites

The radiation-sensitive nature of halide perovskites has hindered structural studies at the atomic scale. We overcome this obstacle by applying low dose-rate in-line holography, which combines aberration-corrected high-resolution transmission electron microscopy with exit-wave reconstruction. This technique successfully yields the genuine atomic structure of ultrathin two-dimensional CsPbBr 3 halide perovskites, and a quantitative structure determination was achieved atom column by atom column using the phase information of the reconstructed exit-wave function without causing electron beam-induced sample alterations. An extraordinarily high image quality enables an unambiguous structural analysis of coexisting high-temperature and low-temperature phases of CsPbBr 3 in single particles. On a broader level, our approach offers unprecedented opportunities to better understand halide perovskites at the atomic level as well as other radiation-sensitive materials.

36 MATERIALS SCIENCE↗

Combined speckle- and propagation-based single shot two-dimensional phase retrieval method

Single-shot two-dimensional (2D) phase retrieval (PR) can recover the phase shift distribution within an object from a single 2D x-ray phase contrast image (XPCI). Two competing XPCI imaging modalities often used for single-shot 2D PR to recover material properties critical for predictive performance capabilities are: speckle-based (SP-XPCI) and propagation-based (PB-XPCI) XPCI imaging. However, PR from SP-XPCI and PB-XPCI images are, respectively, limited to reconstructing accurately slowly and rapidly varying features due to noise and differences in their contrast mechanisms. Herein, we consider a combined speckle- and propagation-based XPCI (SPB-XPCI) image by introducing a mask to generate a reference pattern and imaging in the near-to-holographic regime to induce intensity modulations in the image. We develop a single-shot 2D PR method for SPB-XPCI images of pure phase objects without imposing restrictions such as object support constraints. It is compared against PR methods inspired by those developed for SP-XPCI and PB-XPCI on simulated and experimental images of a thin glass shell before and during shockwave compression. Reconstructed phase maps show improvements in quantitative scores of root-mean-square error and structural similarity index measure using our proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional Reconstruction and Homogenization of Heterogeneous Materials Using Statistical Correlation Functions and FEM

In this study, a previously developed reconstruction methodology is extended to three-dimensional reconstruction of a three-phase microstructure, based on two-point correlation functions and two-point cluster functions. The reconstruction process has been implemented based on hybrid stochastic methodology for simulating the virtual microstructure. While different phases of the heterogeneous medium are represented by different cells, growth of these cells is controlled by optimizing parameters such as rotation, shrinkage, translation, distribution and growth rates of the cells. Based on the reconstructed microstructure, finite element method (FEM) was used to compute the effective elastic modulus and effective thermal conductivity. A statistical approach, based on two-point correlation functions, was also used to directly estimate the effective properties of the developed microstructures. Good agreement between the predicted results from FEM analysis and statistical methods was found confirming the efficiency of the statistical methods for prediction of thermo-mechanical properties of three-phase composites.

36 MATERIALS SCIENCE↗

Imaging Asteroid 4 Vesta Using the Framing Camera

The Framing Camera (FC) onboard the Dawn spacecraft serves a dual purpose. Next to its central role as a prime science instrument it is also used for the complex navigation of the ion drive spacecraft. The CCD detector with 1024 by 1024 pixels provides the stability for a multiyear mission and its high requirements of photometric accuracy over the wavelength band from 400 to 1000 nm covered by 7 band-pass filters. Vesta will be observed from 3 orbit stages with image scales of 227, 63, and 17 m/px, respectively. The mapping of Vesta s surface with medium resolution will be only completed during the exit phase when the north pole will be illuminated. A detailed pointing strategy will cover the surface at least twice at similar phase angles to provide stereo views for reconstruction of the topography. During approach the phase function of Vesta was determined over a range of angles not accessible from earth. This is the first step in deriving the photometric function of the surface. Combining the topography based on stereo tie points with the photometry in an iterative procedure will disclose details of the surface morphology at considerably smaller scales than the pixel scale. The 7 color filters are well positioned to provide information on the spectral slope in the visible, the depth of the strong pyroxene absorption band, and their variability over the surface. Cross calibration with the VIR spectrometer that extends into the near IR will provide detailed maps of Vesta s surface mineralogy and physical properties. Georeferencing all these observation will result in a coherent and unique data set. During Dawn s approach and capture FC has already demonstrated its performance. The strong variation observed by the Hubble Space Telescope can now be correlated with surface units and features. We will report on results obtained from images taken during survey mode covering the whole illuminated surface. Vesta is a planet-like differentiated body, but its surface gravity and escape velocity are comparable to those of other asteroids and hence much smaller than those of the inner planets or

Keller, H. Uwe↗

Single-frame far-field diffractive imaging with randomized illumination

We introduce a single-frame diffractive imaging method called randomized probe imaging (RPI). In RPI, a sample is illuminated by a structured probe field containing speckles smaller than the sample’s typical feature size. Quantitative amplitude and phase images are then reconstructed from the resulting far-field diffraction pattern. The experimental geometry of RPI is straightforward to implement, requires no near-field optics, and is applicable to extended samples. When the resulting data are analyzed with a complimentary algorithm, reliable reconstructions which are robust to missing data are achieved. To realize these benefits, a resolution limit associated with the numerical aperture of the probe-forming optics is imposed. RPI therefore offers an attractive modality for quantitative X-ray phase imaging when temporal resolution and reliability are critical but spatial resolution in the tens of nanometers is sufficient. We discuss the method, introduce a reconstruction algorithm, and present two proof-of-concept experiments: one using visible light, and one using soft X-rays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗