Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Following O and OH in He/O 2 and He/H 2 O gas mixtures—from the gas phase through the liquid phase to modifications on a biological sample

Abstract Applied cold atmospheric plasma allows for the controlled delivery of reactive oxygen and nitrogen species tailored for specific applications. Through the manipulation of the plasma parameters, feed gases, and careful consideration of the environment surrounding the treatment target, selective chemistries that preferentially influence the target can be produced and delivered. To demonstrate this, the COST reference microscale atmospheric pressure plasma jet is used to study the generation and transport of O and ⋅ OH from the gas phase through the liquid to the biological model target cysteine. Relative and absolute species densities of ⋅ OH and O are measured in the gas phase through laser induced fluorescence (LIF) and two-photon absorption LIF respectively. The transport of these species is followed into the liquid phase by hydrogen peroxide quantification and visualized by a fluorescence assay. Modifications to the model biological sample cysteine exposed to ⋅ OH and H 2 O 2 dominated chemistry (He/H 2 O (0.25%)) and O dominated chemistry (He/O 2 (0.6%)) is measured by FTIR spectroscopy. The origin of these species that modify cysteine is considered through the use of heavy water (H 2 18 O) and mass spectrometry. It is found that the reaction pathways differ significantly for He/O 2 and He/H 2 O. Hydrogen peroxide is formed mainly in the liquid phase in the presence of a substrate for He/O 2 whereas for He/H 2 O it forms in the gas phase. The liquid chemistry resulting from the He/O 2 admixture mainly targets the sulfur moiety of cysteine for oxidation up to irreversible oxidation states, while He/H 2 O treatment leads preferentially to reversible oxidation products. The more O or OH/H 2 O 2 dominated chemistry produced by the two gas admixtures studied offers the possibility to select species for target modification.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxidation of lithium plasma facing components and its effect on plasma performance in the lithium tokamak experiment-β

The characteristics of lithium-coated plasma-facing components (PFCs) have been correlated with plasma performance on the lithium tokamak experiment-β (LTX-β). Previous experiments on LTX showed that the application of lithium to PFCs was needed to achieve higher performance discharges with flat electron temperature profiles and high edge temperatures. Samples that match the LTX-β PFCs were exposed to plasmas before and after PFCs were coated with lithium and transferred under vacuum to a surface analysis station. Measurements using x-ray photoelectron spectroscopy (XPS) revealed that the primary surface constituent was lithium oxide. Earlier XPS analysis of lithium-coated PFCs on LTX was only able to show the presence of surface oxygen. The new XPS data from LTX-β have sufficient resolution to clearly identify lithium compounds for the first time, and enable them to be correlated with how lithium-coated PFCs can reduce impurities and retain hydrogen to reduce recycling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Reversed Field Pinch Research in MST (Final Technical Report)

This is the Final Technical Report for the cooperative agreement DE-FC02-05ER54814 titled “Reversed Field Pinch Research in MST” spanning the funding period 4/1/2005 to 12/14/2019. It summarizes key results from MST research, major publications and presentations, and the mentoring of graduate students and postdocs. The Madison Symmetric Torus (MST) is unique within the U.S. and world fusion plasma program. As one of just five operating reversed field pinch (RFP) experiments, and the only one in the U.S., MST has had an important role in advancing the fundamental understanding of the RFP plasma configuration. The MST research program targets topics that intersect with all three goals. While MST provides a unique opportunity to advance the science and fusion potential of the RFP, as a cousin to the tokamak and stellarator plasma configurations the RFP is a valuable partner in establishing validated predictive capability for fusion science more generally. Specific combinations of the major variables in toroidal confinement, like magnetic field strength, plasma current, and shaping, define the different configurations. By exploring adjacent regions in this major variable parameter space, the RFP exposes dependencies not otherwise accessible in the tokamak and stellarator. This diversity enlarges the arena for scientific discovery, both for fusion and plasma physics. The basic science emphasis for MST research has been the self-organizing behavior of RFP plasmas. This inspired MST’s participation in the NSF Physics Frontier Center for Magnetic Self-Organization in Laboratory and Astrophysical Plasmas (CMSO), which ran from 2004-2016 and motivated a substantial fraction of MST’s research goals and capabilities. By all measures the MST Program has been remarkably successful in publications, community engagement, and mentoring of young scientists. While the DOE-FES’s proof-of-principle program for the RFP now languishes through the cessation of this cooperative agreement, operation of MST continues as one of two devices included in the new Wisconsin Plasma Physics Laboratory (WiPPL) basic science user facility. The scope of present research for MST in WiPPL is narrowed to the basic science associated with the RFP magnetic configuration and the advancement of specific fusion topics, which now includes studies of disruptions in tokamak plasmas. The world’s effort in RFP fusion research continues, despite a lack of U.S. federal support to investigate the RFP configuration for fusion application, most notably through a major upgrade to the RFX-mod2 facility in Italy [1] and the recent construction of the KTX facility at USTC in China. First plasmas for RFX-mod2 are anticipated in 2021.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Crystal X-Ray Spectropolarimetry using Cubic Crystals

Presentation to be given on a virtual conference, December 3, 2020, High-Temperature Plasma Diagnostics. Conference: http://www.cvent.com/events/2020-high-temperatures-conference/event-summary-316fe078c3894ef5ab725d6bbdf69334.aspx

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear X-ray Optics

Novel X-ray free-electron lasers (XFELs) are capable of producing radiation with unprecedented properties. Specifically, their ultrashort coherent X-ray pulses can generate extreme peak intensities where ordinary rules of light-matter interaction may no longer apply, and nonlinear processes start to become important. XFELs have made it possible to observe some of the most important coherent non-sequential nonlinearities, including X-ray-optical sum frequency generation (SFG), X-ray second harmonic generation (XSHG), two-photon absorption (TPA) and nonlinear two-photon Compton scattering (2PCS). In particular, the 2PCS experiment has led to unexpected results, namely the observation of a substantial anomalous red shift in the energy of photons generated by nonlinear two-photon X-ray Compton scattering in beryllium. The energy shift is in addition to the predicted nonlinear Compton shift and was neither expected from extrapolations from linear X-ray interactions nor from nonlinear effects at optical wavelengths. Our results suggest a novel nonlinear scattering mechanism that can only be observed at high fields at X-ray wavelengths, where the photon energy is a significant fraction of the electron rest mass (and thus a significant momentum transfer to the electron occurs during the scattering) and where the interaction is not dominated by the quiver motion of the electron in the field (ponderomotive potential) as is usually the case at longer (optical) wavelengths. The goal of this research project was the investigation of fundamental nonlinear X-ray-matter interactions. As these processes are typically weak, part of this research is the exploration of more efficient nonlinear X-ray processes by studying novel mechanisms including solid-state effects, the assistance of optical radiation and novel phase-matching techniques. These experiments require extremely large X-ray field strengths, such as produced by XFELs. Nonlinear X-ray effects can lead to important applications in many research fields. For example, it could lead to instantaneous plasma diagnostics for materials in extreme conditions, as a method for combining atomic-scale structural sensitivity with chemical specificity, or as a probe of electron dynamics in solids on the attosecond (1 as = 10 -18 s) time- and Ångstrom (10 -10 m) length scales. In addition, a detailed understanding of nonlinear X-ray matter interactions is crucial for understanding and extending the limits of structural determination at high intensity such as in serial femto-crystallography. The results could have a profound impact on advanced XFEL light sources such as the LCLS-II.

47 OTHER INSTRUMENTATION↗

Fluctuations and Self-Organization in Plasma Boundary Layers (Final Report)

Final technical report on an experimental study of the boundary of an ionized gas (plasma) where it interacts with solid surfaces. The plasma self-organizes into a sheath which experiences plasma flow and is naturally unstable to various fluctuations which can be observed with advanced laser-spectroscopy techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-Plasma Spatiotemporal Cyanide Spectroscopy and Applications

This article reports new measurements of laser-induced plasma hypersonic expansion measurements of diatomic molecular cyanide (CN). Focused, high-peak-power 1064 nm Q-switched radiation of the order of 1 TW/cm 2 generated optical breakdown plasma in a cell containing a 1:1 molar gas mixture of N 2 and CO 2 at a fixed pressure of 1.1 × 10 5 Pascal and in a 100 mL/min flow of the mixture. Line-of-sight (LOS) analysis of recorded molecular spectra indicated the outgoing shockwave at expansion speeds well in excess of Mach 5. Spectra of atomic carbon confirmed increased electron density near the shockwave, and, equally, molecular CN spectra revealed higher excitation temperature near the shockwave. Results were consistent with corresponding high-speed shadowgraphs obtained by visualization with an effective shutter speed of 5 nanoseconds. In addition, LOS analysis and the application of integral inversion techniques allow inferences about the spatiotemporal plasma distribution.

36 MATERIALS SCIENCE↗

Laser-Plasma Spectroscopy of Hydroxyl with Applications

This article discusses laser-induced laboratory-air plasma measurements and analysis of hydroxyl (OH) ultraviolet spectra. The computations of the OH spectra utilize line strength data that were developed previously and that are now communicated for the first time. The line strengths have been utilized extensively in interpretation of recorded molecular emission spectra and have been well-tested in laser-induced fluorescence applications for the purpose of temperature inferences from recorded data. Moreover, new experiments with Q-switched laser pulses illustrate occurrence of molecular recombination spectra for time delays of the order of several dozen of microseconds after plasma initiation. The OH signals occur due to the natural humidity in laboratory air. Centrifugal stretching of the Franck-Condon factors and r-centroids are included in the process of determining the line strengths that are communicated as a Supplementary File. Laser spectroscopy applications of detailed OH computations include laser-induced plasma and combustion analyses, to name but two applications. This work also includes literature references that address various diagnosis applications.

47 OTHER INSTRUMENTATION↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Data augmentation for disruption prediction via robust surrogate models

The goal of this work is to generate large statistically representative datasets to train machine learning models for disruption prediction provided by data from few existing discharges. Such a comprehensive training database is important to achieve satisfying and reliable prediction results in artificial neural network classifiers. Here, we aim for a robust augmentation of the training database for multivariate time series data using Student-t process regression. We apply Student-t process regression in a state space formulation via Bayesian filtering to tackle challenges imposed by outliers and noise in the training data set and to reduce the computational complexity. Thus, the method can also be used if the time resolution is high. We use an uncorrelated model for each dimension and impose correlations afterwards via coloring transformations. We demonstrate the efficacy of our approach on plasma diagnostics data of three different disruption classes from the DIII-D tokamak. To evaluate if the distribution of the generated data is similar to the training data, we additionally perform statistical analyses using methods from time series analysis, descriptive statistics, and classic machine learning clustering algorithms.

97 MATHEMATICS AND COMPUTING↗

Investigation of ion beam diagnostics final report

Ion beam diagnostics - plasma wind tunnel stream generation and characteristics, mercury optical resonance probe, environment effects on ion stream neutralization, and electric field meters

PLASMA GENERATION↗