Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Cooling Strategies for an Electric Motor with Additively Manufactured Hollow Conductors and Distributed Power Electronics Integrated with Heat Pipes

This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.

additive manufacturing↗

Summary of DASSH-CFD Inter-Assembly Heat Transfer Comparison

Fast reactor core design requires integration of detailed power distributions obtained from neutronics models and thermal fluids calculations to determine temperature distributions and flow conditions. During the design phase, calculations may be repeated as specifications change and computational expense must be balanced with solution accuracy, creating an opportunity for the use of intermediate-fidelity codes. To that end, the Ducted Assembly Steady-State Heat Transfer Software (DASSH) has been developed at Argonne National Laboratory to perform full-core, steady state coolant and fuel pin temperature calculations in reactors consisting of hexagonal, ducted assemblies. DASSH is a first-order, finite volume subchannel code based on methodologies initially introduced in the legacy thermal hydraulics codes SUPERENERGY-2 and SE2-ANL. It can work coupled with the Argonne Reactor Computational (ARC) code suite to obtain neutron and gamma power distributions based on neutron transport solutions and features many improvements and new capabilities compared to its predecessors. DASSH calculates temperatures by balancing energy between subchannels and relies on correlations to account for flow distribution and coolant mixing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

pnnl/oedisi_dopf

OpenEDI - System Integration (OEDI-SI) - PNNL Distributed Optimal Power Flow (DOPF)

Slay, Tylor↗

A crystal plasticity finite element model embedding strain-rate sensitivities inherent to deformation mechanisms: Application to alloy AZ31

We report the fundamental power-law relationship representing the flow rule in crystal visco-plasticity ensures uniqueness in the selection of slip systems accommodating imposed plastic strain-rates. The power-law relationship also introduces an artificially high strain-rate sensitivity in crystal plasticity simulations, unless a high value of the power-law exponent is used. However, the use of high values for the exponent is limited by numerical tractability. This paper presents a numerical method implemented in a crystal plasticity finite element (CPFE) model for embedding any value of the power-law exponent reflecting the true material strain-rate sensitivity. Importantly, the method does not increase computation time involved in the simulations. The enhanced CPFE model is used to interpret and predict a complex strain-rate sensitive response and microstructural evolution of AZ31 Mg alloy. Measured values of strain-rate sensitivity for slip and twinning modes are used in the simulations. Calculations show that the model successfully captures the phenomena pertaining to the effect of changing applied strain-rate on the mechanical response including flow stress and evolution of texture and twinning for a broad range of strain-rates ranging from 10 -3 s -1 to 10 3 s -1 and loading orientations in tension and compression. It is shown that such predictions are a consequence of not only relative amounts of slip and twinning activities driven by a set of accurately characterized hardening law parameters but also values of the strain-rate sensitivities inherent to individual deformation mechanisms. Besides, the model validates the measured strain-rate dependency of deformation mechanisms while accurately reproducing the mechanical data. Hence, the model can be used to verify and further refine or infer measured strain-rate sensitivity per deformation mechanism by reproducing experimental data.

36 MATERIALS SCIENCE↗

Expanded capabilities of the CarMa code in modeling resistive wall mode dynamics with 3-D conductors

In this work, an improved version of the CarMa code is presented, called CarMa-D, for the analysis of resistive wall modes (RWMs) in fusion devices, simultaneously considering the effects of volumetric three-dimensional conducting structures, plasma dynamics, toroidal rotation or drift-kinetic damping. Unlike static CarMa, CarMa-D does not rely on the simplifying assumptions such as neglecting the plasma mass, toroidal rotation and kinetic damping. The new coupling strategy is based on matrix-based Padé rational functions approximation of plasma a response. The arising mathematical model is formally equivalent to the original CarMa model, but with a higher number of degrees of freedom to model the dynamics of the plasma. CarMa-D overcomes the main limitations of the original CarMa, in particular: (i) the massless assumption for the plasma is removed, allowing modeling of global modes growing both on ideal kink time scales and in the typical RWM growth rate regime, with a suitable treatment of the model; (ii) the effects of toroidal plasma flow and drift kinetic damping can be included into the new model, providing a powerful tool to study macroscopic phenomena where both plasma dynamics and 3-D conducting structures play important roles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Energy Scheduling and Sensitivity Analysis for Integrated Power-Water-Heat Systems

The conventionally independent power, water, and heating networks are becoming more tightly connected, which motivates their joint optimal energy scheduling to improve the overall efficiency of an integrated energy system. However, such a joint optimization is known as a challenging problem with complex network constraints and couplings of electric, hydraulic, and thermal models that are nonlinear and nonconvex. We formulate an optimal power-water-heat flow (OPWHF) problem and develop a computationally efficient heuristic to solve it. The proposed heuristic decomposes OPWHF into subproblems, which are iteratively solved via convex relaxation and convex-concave procedure. Simulation results validate that the proposed framework can improve operational flexibility and social welfare of the integrated system, wherein the water and heating networks respond as virtual energy storage to time-varying energy prices and solar photovoltaic generation. Moreover, we perform sensitivity analysis to compare two modes of heating network control: by flow rate and by temperature. Our results reveal that the latter is more effective for heating networks with a wider space of pipeline parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-duration Energy Storage Technology Analysis and Development

This project develops a new low-cost and flexible long-duration energy storage (LDES) technology based on simultaneous regeneration technology. In lieu of the technology development, the project team also conducts a complete cost analysis for LDES based on various currently available technologies, as well as grid economic and environmental benefits analysis for LDES. There are three tasks in this project: Task 1. Fe-H2 flow cell fabrication, testing, demonstration; Task 2. Dynamic modeling, simulation and control architecture of power system; Task 3. Cost and grid analysis.

25 ENERGY STORAGE↗

Optimization and Physics Informed AI/ML on the Cooling Tower Power Output and the One-Dimensional Model

Graduate Research at Missouri S&T Thesis: Theoretical Study of Magnetic Particles in a Shear Flow Subjected to a Uniform Magnetic Field. • Published several journal articles. • Presented at the Indiana University Purdue University Indianapolis graduate seminar. • Presented research findings at American Physical Society: Division of Fluid Dynamics and poster sessions at Missouri S&T for the Chancellor's Distinguished Fellowship.

Sobecki, Christopher A.↗

New Developments and Capabilities Within WEC-Sim

WEC-Sim is an open-source software for simulating wave energy converters and has been actively developed and applied since its initial release in 2014 to simulate a wide variety of device archetypes. WEC-Sim is developed jointly by the National Renewable Energy Laboratory and Sandia National Laboratories within the MATLAB/SIMULINK environment. A general wave-to-wire model begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of wave energy converters (WEC), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modeling the entire wave-to-wire is difficult and encompasses multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze, and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). With this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Additional WEC-Sim functionalities include pre-built Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems. The developers of WEC-Sim continue to release new versions of the software, at least annually, with the latest release in September 2022. These releases include bug fixes, updates to software documentation, as well as new features to expand WEC-Sim's capabilities to model a wide range of WEC concepts. This publication will highlight the new features added to WEC-Sim between versions 4.1.0 to 5.0.1, which spans a 2-year period from June 2020 to September 2022. New features described here include topics such as continuous integration checks, revised Morison Element and nonlinear hydro implementations, run directly from Simulink (required for hardware-in-the-loop execution), BEMIO updates to import Capytaine BEM hydrodynamics, addition of cable blocks, and new wave visualization features.

TIDAL AND WAVE POWER↗

Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim (Wave Energy Converter SIMulator) is an open-source code for simulating wave energy converters, which has been actively developed and applied to simulate a wide variety of device archetypes and has become a popular tool since its initial release in 2014. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) within the MATLAB/SIMULINK environment. Figure 1 illustrates a general wave-to-wire model which begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of a single WEC (or array), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modelling the entire wave-to-wire is difficult and encompass multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM) based-frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Table 1 lists additional WEC-Sim functionalities, which are created using prebuilt Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems.

hydrodynamics modeling↗

New Developments and Capabilities Within WEC-Sim: Preprint

WEC-Sim is an open-source software for simulating wave energy converters, which has been actively developed and applied since its initial release in 2014 to simulate a wide variety of device archetypes. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (Sandia) within the MATLAB/SIMULINK environment. A general wave-to-wire model begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of wave energy converters (WEC), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modeling the entire wave-to-wire is difficult and encompasses multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze, and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). With this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Additional WEC-Sim functionalities include pre-built Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems. The developers of WEC-Sim continue to release new versions of the software, at least annually, with our latest release in September 2022. These releases include bug fixes, updates to software documentation, as well as new features to expand WEC-Sim's capabilities to model a wide range of WEC concepts. This publication will highlight the new features added to WEC-Sim between versions 4.1.0 to 5.0.1 which spans over a two year period from June 2020 to September 2022. New features to be described will include topics such as continuous integration checks, revised Morison Element and nonlinear hydro implementations, run directly from Simulink (required for hardware-in-the-loop execution), BEMIO updates to import Capytaine BEM hydrodynamics, addition of cable blocks, and new wave visualization features.

TIDAL AND WAVE POWER↗

Models and Strategies for Optimal Demand Side Management in the Chemical Industries

Deregulation and the increase of renewable electricity generation from wind and solar photovoltaics have transformed the U.S. electricity market. Economic and environmental benefits notwithstanding, the presence of renewables has increased variability and uncertainty on the supply side of the grid. Managing demand, rather than generation – a strategy referred to as “demand response (DR)” – is an attractive approach for mitigating this imbalance. DR efforts aim to reduce electricity usage during peak demand times, lessening stress on the grid. Industrial users are particularly attractive entities for DR participation since they present large, localized loads that can provide significant relief on grid demand and –unlike other large loads, such as buildings – are minimally dependent on human needs and preferences. In this project, we accomplished three main objectives. (1) We developed data-driven low-order DR scheduling-relevant dynamic models of chemical processes. Concurrently, we studied the formulation and solution of the associated optimal DR production scheduling problems. (a) A prototype air separation unit (ASU) model was used to generate simulated operating data for initial modeling efforts, which enabled the later use of industrial data for data-driven modeling. (b) We utilized Hammerstein-Wiener (HW) and Finite Step Response (FSR) models to represent nonlinear plant dynamics. (c) The HW models were linearized using exact linearization so they could potentially be embedded in power system models, which are formulated as mixed integer linear programs (MILPs). (d) We solved DR optimization problems under uncertainty and found that even naïve predictions of electricity price and product demand led to significant cost savings benefits. (2) Our DR scheduling optimization problem formulations are amenable to real-time solution. (a) We utilized Lagrangian Relaxation (LR) to efficiently solve the optimization problem by decoupling subproblems linked by complicating constraints. (b) We have achieved computation times for the 3-day DR scheduling problem of an ASU as low as 1.88 minutes. (3) Our representations of the DR behavior of chemical process as grid-level batteries were embedded in power system models. (a) For a small-scale grid, we found that incorporating the dynamics of the chemical plant in the optimal power flow calculations resulted in better resource management leading to up to 15% and 46% cost reduction for the grid and chemical plant operations, respectively, during periods of power line congestion. We have published several works dedicated to modeling and solving DR optimization problems from the user side. These were published in top peer-reviewed journals and are summarized in this report. The most recent work (and papers in preparation) considers DR scheduling from the grid side. Future efforts will consider networked plants (e.g., air separation units operating on a common pipeline) for DR participation, which is expected to amplify the capabilities of industrial DR participants to perform load-shifting. Our consideration of uncertainty in DR has inspired future directions in this area as well: we plan to develop multistage methods to fully account for the effects of uncertainty in DR scheduling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Physics and technology considerations for the deuterium–tritium fuel cycle and conditions for tritium fuel self sufficiency

The tritium aspects of the DT fuel cycle embody some of the most challenging feasibility and attractiveness issues in the development of fusion systems. The review and analyses in this paper provide important information to understand and quantify these challenges and to define the phase space of plasma physics and fusion technology parameters and features that must guide a serious R&D in the world fusion program. We focus in particular on components, issues and R&D necessary to satisfy three 'principal requirements': (1) achieving tritium self-sufficiency within the fusion system, (2) providing a tritium inventory for the initial start-up of a fusion facility, and (3) managing the safety and biological hazards of tritium. A primary conclusion is that the physics and technology state-of-the-art will not enable DEMO and future power plants to satisfy these principal requirements. We quantify goals and define specific areas and ideas for physics and technology R&D to meet these requirements. A powerful fuel cycle dynamics model was developed to calculate time-dependent tritium inventories and flow rates in all parts and components of the fuel cycle for different ranges of parameters and physics and technology conditions. Dynamics modeling analyses show that the key parameters affecting tritium inventories, tritium start-up inventory, and tritium self-sufficiency are the tritium burn fraction in the plasma (f b ), fueling efficiency (η f ), processing time of plasma exhaust in the inner fuel cycle (t p ), reactor availability factor (AF), reserve time (tr) which determines the reserve tritium inventory needed in the storage system in order to keep the plant operational for time t r in case of any malfunction of any part of the tritium processing system, and the doubling time (t d ). Results show that η f f b > 2% and processing time of 1–4 h are required to achieve tritium self-sufficiency with reasonable confidence. For η f f b = 2% and processing time of 4 h, the tritium start-up inventory required for a 3 GW fusion reactor is ~11 kg, while it is <5 kg if η f f b = 5% and the processing time is 1 h. To achieve these stringent requirements, a serious R&D program in physics and technology is necessary. The EU-DEMO direct internal recycling concept that carries fuel directly from the plasma exhaust gas to the fueling systems without going through the isotope separation system reduces the overall processing time and tritium inventories and has positive effects on the required tritium breeding ratio (TBR R ). A significant finding is the strong dependence of tritium self-sufficiency on the reactor availability factor. Simulations show that tritium self-sufficiency is: impossible if AF < 10% for any η f f b , possible if AF > 30% and 1% ≤ η f f b ≤ 2%, and achievable with reasonable confidence if AF > 50% and η f f b > 2%. These results are of particular concern in light of the low availability factor predicted for the near-term plasma-based experimental facilities (e.g. FNSF, VNS, CTF), and can have repercussions on tritium economy in DEMO reactors as well, unless significant advancements in RAMI are made. There is a linear dependency between the tritium start-up inventory and the fusion power. The required tritium start-up inventory for a fusion facility of 100 MW fusion power is as small as 1 kg. Since fusion power plants will have large powers for better economics, it is important to maintain a 'reserve' tritium inventory in the tritium storage system to continue to fuel the plasma and avoid plant shutdown in case of malfunctions of some parts of the tritium processing lines. But our results show that a reserve time as short as 24 h leads to unacceptable reserve and start-up inventory requirements. Therefore, high reliability and fast maintainability of all components in the fuel cycle are necessary in order to avoid the need for storing reserve tritium inventory sufficient for continued fusion facility operation for more than a few hours. The physics aspects of plasma fueling, tritium burn fraction, and particle and power exhaust are highly interrelated and complex, and predictions for DEMO and power reactors are highly uncertain because of lack of experiments with burning plasma. Fueling by pellet injection on the high field side of tokamak has evolved to be the preferred method to fuel a burning plasma. Extrapolation from the DIII-D penetration scaling shows fueling efficiency expected in DEMO to be <25%, but such extrapolations are highly uncertain. The fueling efficiency of gas in a reactor relevant regime is expected to be extremely poor and not very useful for getting tritium into the core plasma efficiently. Gas fueling will nonetheless be useful for feedback control of the divertor operating parameters. Extensive modeling has been carried out to predict burn fraction, fueling requirements, and fueling efficiency for ITER, DEMO, and beyond. The fueling rate required to operate Q = 10 ITER plasmas in order to provide the required core fueling, helium exhaust and radiative divertor plasma conditions for acceptable divertor power loads was calculated. If this fueling is performed with a 50–50 DT mix, the tritium burn fraction in ITER would be ~0.36%, which is too low to satisfy the self-sufficiency conditions derived from the dynamics modeling for fusion reactors. Extrapolation to DEMO using this approach would also yield similarly low burn fraction. Extensive analysis presented shows that specific features of edge neutral dynamics in ITER and fusion reactors, which are different from present experiments, open possibilities for optimization of tritium fueling and thus to improve the burn fraction. Using only tritium in pellet fueling of the plasma core, and only deuterium for edge density, divertor power load and ELM control results in significant increase of the burn fraction to 1.8–3.6%. These estimates are performed with physics models whose results cannot be fully validated for ITER and DEMO plasma conditions since these cannot be achieved in present tokamak experiments. Thus, several uncertainties remain regarding particle transport and scenario requirements in ITER and DEMO. The safety standard requirements for protection of the public and release guidelines for tritium have been reviewed. General safety approaches including minimizing tritium inventories, reducing tritium permeation through materials, and decontaminating material for waste disposal have been suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing in-stream turbulent flow for tidal energy converter siting in Cook Inlet, Alaska

Cook Inlet in Alaska is the most promising location for tidal energy development in the U.S. due to its significant tidal range of approximately 10 meters and high volume flux. The inlet's unique geometry and flow characteristics make it the most energetic tidal stream in the nation, with GW-scale potential energy capacity. With the growing interest in tidal energy converter (TEC) deployment in this area, we implemented a regional-scale, 3D hydrodynamic modeling framework to predict tidal current and turbulence characteristics that can assist TEC designers and project managers. We validated the model results extensively using various datasets collected with bottom-mounted acoustic Doppler current profilers and velocimeters. The comparison between the model outputs and observational data highlighted the effectiveness of the 3D FVCOM model and the Mellor-Yamada Level 2.5 Turbulence Model in accurately assessing macro-scale kinetic energy, turbulence intensity, and the production and dissipation rates at a prospective TEC site. Using two months of model simulation data, we examined the channel cross-section for TEC deployment, focusing on undisturbed power density and macro-scale turbulent properties. Further, our findings indicate that understanding the turbulence characteristics and flow properties can enhance Stage I/II resource characterization by identifying optimal locations for TECs and their layouts within the channel. Furthermore, we demonstrated that TEC designers can utilize macro-scale turbulence data from 3D coastal models as boundary conditions for other turbulence models, allowing for a more detailed resolution of the turbulence structure at TEC siting locations. Ultimately, this work emphasizes the importance of estimating flow and turbulence conditions in energetic systems to understand turbulent sites better and improve resource characterization.

16 TIDAL AND WAVE POWER↗

OPF-Learn: An Open-Source Framework for Creating Representative AC Optimal Power Flow Datasets: Preprint

Increasing levels of renewable generation motivate a growing interest in data-driven approaches for AC optimal power flow (AC OPF) to manage uncertainty. However, a lack of disciplined dataset creation and benchmarking prohibits useful comparison between approaches in the literature. To instigate confidence, models must be able to reliably predict solutions across a wide range of operating conditions. This paper develops the OPF-Learn package for Julia and Python which uses a computationally efficient approach to create representative datasets that span a wide spectrum of the AC OPF feasible region. Load profiles are uniformly sampled from a convex set that contains the AC OPF feasible set. For each infeasible point found, the convex set is reduced using infeasibility certificates, found by utilizing properties of a relaxed formulation. The framework is shown to generate datasets which are more representative of the entire feasible space versus traditional techniques seen in the literature, improving machine learning model performance.

dataset↗

Machine Learning Based Network Parameter Estimation Using AMI Data

The expansion of distribution power system and the growing penetration of distributed energy resources present new challenges for situational awareness. Calibrating the extended system model with sensor measurements and maintaining the usability is critical for utilities. This paper presents a distribution network parameter estimation (DNPE) approach using machine learning (ML) and metering data that improve the quality of extended distribution power system modeling. The reliability model can improve the ability of endpoint data to be translated into network-level situational awareness in real time and help distribution system operators (DSOs) solve branch flow and voltage problems. In addition, a data analytic and automate processing scheme is proposed to improve the sensor data quality and prevent misleading information. The effectiveness of the proposed method is verified with actual advanced metering infrastructure (AMI) data on a real utility feeder model, while considering the higher penetration of photovoltaic power generation. The test of DNPE and study results are demonstrated in this paper.

Parameter estimation, machine learning, power dist↗