Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power offset”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Business Case for a Micro-Combined Heat and Power Fuel Cell System in Commercial Applications

Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a business case for CHP-FCSs in the range of 5 to 50 kWe. Systems in this power range are considered micro-CHP-FCS. For this particular business case, commercial applications rather than residential or industrial are targeted. To understand the benefits of implementing a micro-CHP-FCS, the characteristics that determine their competitive advantage must first be identified. Locations with high electricity prices and low natural gas prices are ideal locations for micro-CHP-FCSs. Fortunately, these high spark spread locations are generally in the northeastern area of the United States and California where government incentives are already in place to offset the current high cost of the micro-CHP-FCSs. As a result of the inherently high efficiency of a fuel cell and their ability to use the waste heat that is generated as a CHP, they have higher efficiency. This results in lower fuel costs than comparable alternative small-scale power systems (e.g., microturbines and reciprocating engines). A variety of markets should consider micro-CHP-FCSs including those that require both heat and baseload electricity throughout the year. In addition, the reliable power of micro-CHP-FCSs could be beneficial to markets where electrical outages are especially frequent or costly. Greenhouse gas emission levels from micro-CHP-FCSs are 69 percent lower, and the human health costs are 99.9 percent lower, than those attributed to conventional coal-fired power plants. As a result, FCSs can allow a company to advertise as environmentally conscious and provide a bottom-line sales advantage. As a new technology in the early stages of adoption, micro-CHP-FCSs are currently more expensive than alternative technologies. As the technology gains a foothold in its target markets and demand increases, the costs will decline in response to improved manufacturing efficiencies, similar to trends seen with other technologies. Transparency Market Research forecasts suggest that the CHP-FCS market will grow at a compound annual growth rate of greater than 27 percent over the next 5 years. These production level increases, coupled with the expected low price of natural gas, indicate the economic payback period will move to less than 5 years over the course of the next 5 years. To better understand the benefits of micro-CHP-FCSs, The U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe fuel cells in the commercial markets of California and Oregon. Pacific Northwest National Laboratory is evaluating these systems in terms of economics, operations, and their environmental impact in real-world applications. As expected, the economic analysis has indicated that the high capital cost of the micro-CHP-FCSs results in a longer payback period than typically is acceptable for all but early-adopter market segments. However, a payback period of less than 3 years may be expected as increased production brings system cost down, and CHP incentives are maintained or improved.

CHP, business case↗

Electro Catalytic Oxidation (ECO) Operation

The power industry in the United States is faced with meeting many new regulations to reduce a number of air pollutants including sulfur dioxide, nitrogen oxides, fine particulate matter, and mercury. With over 1,000 power plants in the US, this is a daunting task. In some cases, traditional pollution control technologies such as wet scrubbers and SCRs are not feasible. Powerspan's Electro-Catalytic Oxidation, or ECO{reg_sign} process combines four pollution control devices into a single integrated system that can be installed after a power plant's particulate control device. Besides achieving major reductions in emissions of sulfur dioxide (SO{sub 2}), nitrogen oxides (NOx), fine particulate matter (PM2.5) and mercury (Hg), ECO produces a highly marketable fertilizer, which can help offset the operating costs of the process system. Powerspan has been operating a 50-MW ECO commercial demonstration unit (CDU) at FirstEnergy Corp.'s R.E. Burger Plant near Shadyside, Ohio, since February 2004. In addition to the CDU, a test loop has been constructed beside the CDU to demonstrate higher NOx removal rates and test various scrubber packing types and wet ESP configurations. Furthermore, Powerspan has developed the ECO{reg_sign}{sub 2} technology, a regenerative process that uses a proprietary solvent to capture CO{sub 2} from flue gas. The CO{sub 2} capture takes place after the capture of NOx, SO{sub 2}, mercury, and fine particulate matter. Once the CO{sub 2} is captured, the proprietary solution is regenerated to release CO{sub 2} in a form that is ready for geological storage or beneficial use. Pilot scale testing of ECO{sub 2} began in early 2009 at FirstEnergy's Burger Plant. The ECO{sub 2} pilot unit is designed to process a 1-MW flue gas stream and produce 20 tons of CO{sub 2} per day, achieving a 90% CO{sub 2} capture rate. The ECO{sub 2} pilot program provided the opportunity to confirm process design and cost estimates, and prepare for large scale capture and sequestration projects. The objectives of this project were to prove at a commercial scale that ECO is capable of extended operations over a range of conditions, that it meets the reliability requirements of a typical utility, and that the fertilizer co-product can be consistently generated, providing ECO with an economic advantage over conventional technologies currently available. Further objectives of the project were to show that the ECO system provides flue gas that meets the inlet standards necessary for ECO{sub 2} to operate, and that the outlet CO{sub 2} and other constituents produced by the ECO{sub 2} pilot can meet Kinder-Morgan pipeline standards for purposes of sequestration. All project objectives are consistent with DOE's Pollution Control Innovations for Power Plants program goals.

54 ENVIRONMENTAL SCIENCES↗

X-ray cavities in a sample of 83 SPT-selected clusters of galaxies: Tracing the evolution of AGN feedback in clusters of galaxies out to z = 1.2

X-ray cavities are key tracers of mechanical (or radio mode) heating arising from the active galactic nuclei (AGNs) in brightest cluster galaxies (BCGs). We report on a survey for X-ray cavities in 83 massive, high-redshift (0.4 7 Gyr at z∼0.8). On average, the detected X-ray cavities have powers of (0.8−5)×10{sup 45} erg s{sup −1}, enthalpies of (3−6)×10{sup 59} erg, and radii of ∼17 kpc. Integrating over 7 Gyr, we find that the supermassive black holes in BCGs may have accreted 10{sup 8} to several 10{sup 9} M{sub ⊙} of material to power these outflows. This level of accretion indicates that significant supermassive black hole growth may occur not only at early times, in the quasar era, but at late times as well. We also find that X-ray cavities at high redshift may inject an excess heat of 0.1–1.0 keV per particle into the hot ICM above and beyond the energy needed to offset cooling. Although this result needs to be confirmed, we note that the magnitude of excess heating is similar to the energy needed to preheat clusters, break self-similarity, and explain the excess entropy in hot atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of land-based wind turbine upsizing on community sound levels and power and energy density

Multiple technological, social, and market factors of wind power are evolving rapidly. Most notably, significant wind turbine scaling is occurring and is forecasted to continue. While the larger turbines expected to be deployed in the future are more powerful and efficient, they are also expected to operate at higher sound levels and require larger setbacks than those installed in the last decade. These sometimes-competing deployment trends and impacts cannot be understood via simple extrapolations of past trends. This study analyzes the effect of these future larger turbines on wind turbine micro-siting, project-level power and energy density, and community noise impacts. Due to their taller heights, larger rotors, and higher sound power levels, future wind turbines will require larger setbacks from homes and greater inter-turbine spacing, resulting in fewer turbines deployed for a given land area. This research finds these changes more than offset the effect of the higher turbine sound emissions, significantly decreasing the average sound levels that wind plant hosting communities experience. Yet, simultaneously, plant layouts using future turbine designs also result in projects with higher installed capacities and annual energy output for a given land area. These increases will likely lead to increased tax benefits and local income in the community. The deployment of fewer turbines on a smaller number of parcels could have implications on siting flexibility and landowner payments.

17 WIND ENERGY↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cayuga County Regional Digester: Vision Becomes Reality. Final Report

With an average herd size of 113 mature cows, Cayuga County is home to 280 dairy farms and 31,500 dairy milking cows producing approximately 855 million gallons of milk per year. The Cayuga Dairy industry is a major contributor to the countys economy, employing nearly 1200 people, while generating $140,000,000 of revenue from sale of milk alone. At the same time, the Cayuga County dairy industry also produces 5.7 million gallons of manure daily: (a) Nearly 34% of this manure is produced on smaller farms. (b) Digesters are expensive pieces of equipment and require attention and care. ( c) The on-farm digester systems have fairly long payback (>10 years) even for larger CAFO farms (>1000 milking cows). In 2005, Cayuga County Soil and Water Conservation District (The District), a Public Agency under Cayuga County, decided to undertake a centralized community digester project. The primary goal of the project was to develop an economically sustainable model, under the auspices of The District to address manure management issues facing the smaller dairies, improve the water quality and improve the quality of life for Cayuga County residents. It is believed that the District has accomplished this goal by completing construction of Cayuga County Regional Digester on a parcel of land behind the Cayuga County Natural Resource Center located at 7413 County House Road in the Town of Sennett in Cayuga County, New York. The digester facility consists of the following major components. 1. Transfer Station: This an indoor truck bay, where 35,000 gallons of manure from three local farms, 8,500 gallons of liquid organic food-processor waste, and 1,200 gallons of brown grease are unloaded from tanker trucks and the digested slurry is loaded onto the tanker trucks for delivery back to the participating farms. 2. Anaerobic Digester: The project utilizes a hydraulic mix anaerobic digester, a unique design that has no internal moving parts for mixing. The digester, which operates at mesophilic temperatures, is designed to process the daily feedstock and produce 220,000 SCF2 of biogas per day. The digester also produces 44,000 gallons of digested slurry per day. 3. Biogas Conditioning System: The plant employs a biological biogas conditioning system to remove the H2S and moisture contents of the biogas and prepare it to be used by the plant generation system. 4. Combined Heat and Power System (CHP): This is a 633kW high efficiency biogas-fired GE-Jenbacher model JMS-312 GS-NL reciprocating engine cogeneration system. The heat recovery system incorporated into the package is designed to capture the waste heat from the engine exhaust, the jacket cooling water and the engine oil circuit. 5. Electrical Substation and Power Distribution Systems: An electrical distribution system has been constructed on-site that aggregates the electrical service of the different county buildings on the District campus into a county owned electric distribution system that is interconnected with the CHP and the local electric grid. The electrical system is designed, in accordance with the utility guidelines, to allow grid-parallel operation of CHP and provide for import and export of electric power. 6. Thermal Energy Distribution System: The heat recovery system has been integrated into a high temperature water distribution system that distributes the heat to the thermal circuits for the anaerobic digester facility. Additional piping has also been installed to transfer the remaining thermal energy to other county buildings on the campus. On a daily basis, the plant will co-process 35,000 gallons of manure from local dairy farms, 8,500 gallons of food-processor waste and 1,200 gallons of brown grease to produce 200,000 ft3/d of biogas and 44,000 gallons of pathogen-free nutrient-rich digested slurry for agricultural use by farms and in the local area.The biogas fueled CHP produces 5,157,000 kWh of electricity and 19,506 dekatherms of thermal energy per year. Electrical power generated by the cogeneration system powers all the buildings on the Cayuga County campus and any surplus power is exported to the grid under a power purchase agreement. Heat recovered from the cogeneration system will be used to maintain the temperature of the process equipment and the excess will be transported to the Cayuga County Public Safety Building to offset purchase of fossil fuel to fuel the boilers. The majority of plant operations are unmanned and automated. However, the plant will have a small staff of well-trained personnel to coordinate the feedstock deliveries and shipments, supervise the day-to-day operation, monitor the systems and perform maintenance, maintain a safe and reliable operation and to respond to emergencies.

09 BIOMASS FUELS↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

Power over Ethernet (PoE) technology offers the ability to provide both low-voltage direct current (DC) power and communication over a standard Ethernet cable—also referred to as a local area network (LAN) cable or Category cable. Light-emitting diode (LED) technology has reduced the power required for lighting applications, while advances in PoE standards and technology have yielded substantial increases in the amount of power that can be delivered to a networked device over a single cable. As a result, PoE technology is emerging in lighting and many other applications beyond its historical foothold in telephony and networking equipment. Several major LED luminaire manufacturers have introduced PoE connected lighting systems in recent years, making this a potentially disruptive technology. PoE lighting systems can offer improved efficiency relative to traditional line voltage alternating current (AC) systems, because AC-DC power conversion losses can be reduced if this work is consolidated among one or more PoE switches, rather than being distributed among a greater number of smaller LED drivers. However, this effect can be offset to some extent by increased losses associated with an increased voltage drop in the low-voltage Ethernet cabling. In fact, these losses could exceed 15% in poorly designed systems. Aspects of cable design that can affect cable energy performance include American Wire Gauge (AWG), Category (e.g., 5e), shielding, and fire rating (e.g., CMP). Installation practices (e.g., bending, bundling, conduit) can also affect cable performance. Although cable energy losses can be predicted with knowledge of conductor DC resistance (DCR), and DCR can be estimated based on rated AWG, most product datasheets state maximum DCR - or reference standards that specify DCR limits - in lieu of nominal DCR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attached Jet Velocity Profiles in Mixing Tanks

Free jets have been studied in detail over much of the last century, but the theory for offset and attached jets remains incomplete. Attached jets differ from free jets in that they lose momentum to nearby surfaces, attenuating their velocities. The velocity profiles of free circular jets are nearly Gaussian, with quantitative mathematical descriptions derived from first principles by Goertler and Tollmien (Rajaratnam, 1976). In contrast, mathematical descriptions of three-dimensional attached jets from circular nozzles remain much less mature. Agelin-Chaab and Tachie (2011) used particle imaging velocimetry of a three-dimensional attached jet to show that the scaled velocity decays with scaled distance from the nozzle with a power law exponent between -1.15 and -1.21, which is larger in magnitude than that of a free jet. However, quantitative analytical expressions for the velocity profiles of attached jets similar to those of free jets remain elusive. This paper addresses this critical gap. Here we evaluate the velocity profiles of three-dimensional offset jets emerging from circular nozzles that that become attached jets. These jets lose momentum due to interactions with nearby surfaces and are important to evaluating flows in mixing vessels and to suspending solids and trapped gases in radioactive waste tanks. Despite the importance of attached jets, prior insight has been purely experimental, limited to overly simplistic analytical models, or restricted to computationally expensive computational fluid dynamics case studies. We compare the expression of Verhoff (1963) to experimental results to find reasonable quantitative agreement. As stated by Agelin-Chaab and Tachie (2011), “detailed velocity measurements of 3D offset jets are rare.” Such remains the case. This study adds to the literature by providing information at two additional Reynolds numbers (1.43 106 and 1.87 106) and evaluating simple but accurate expressions for velocity profiles. These Reynolds numbers are an order of magnitude higher than prior reports. The semi-empirical stream wise velocity profile perpendicular to the surface proposed by Verhoff (1963) is in approximate agreement with these velocity profiles, which is surprising because these attached jets are three-dimensional instead of two-dimensional as evaluated by Verhoff. However, additional work is necessary to fully describe these profiles quantitatively.

jet, attached jet, offset jet↗

Flow of “stress power-law” fluids between parallel rotating discs with distinct axes

The problem of flow between parallel rotating discs with distinct axes corresponds to the case of flow in an orthogonal rheometer and has been studied extensively for different fluids since the instrument's inception. All the prior studies presume a constitutive prescription of the fluid stress in terms of the kinematical variables. In this paper, we approach the problem from a different perspective, i.e., a constitutive specification of the symmetric part of the velocity gradient in terms of the Cauchy stress. Such an approach ensures that the boundary conditions can be incorporated in a manner quite faithful to real world experiments with the instrument. Interestingly, the choice of the boundary condition is critical to the solvability of the problem for the case of creeping/Stokes flow. Furthermore, when the no-slip condition is enforced at the boundaries, depending on the model parameters and axes offset, the fluid response can show non-uniqueness or unsolvability, features which are absent in a conventional constitutive specification. In case of creeping/Stokes flow with prescribed values of the stress, the fluid response is indeterminate. We also record the response of a particular case of the given “stress power-law” fluid; one that cannot be attained by the conventional power-law fluids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring and Modeling Fault Density for Plume-Fault Encounter Probability Estimation

Emission of carbon dioxide from fossil-fueled power generation stations contributes to global climate change. Storage of this carbon dioxide within the pores of geologic strata (geologic carbon storage) is one approach to mitigating the climate change that would otherwise occur. The large storage volume needed for this mitigation requires injection into brine-filled pore space in reservoir strata overlain by cap rocks. One of the main concerns of storage in such rocks is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available. This necessitates a method for using available fault data to develop an estimate of the likelihood of injected carbon dioxide encountering and migrating up a fault, primarily due to buoyancy. Fault population statistics provide one of the main inputs to calculate the encounter probability. Previous fault population statistics work is shown to be applicable to areal fault density statistics. This result is applied to a case study in the southern portion of the San Joaquin Basin with the result that the probability of a carbon dioxide plume from a previously planned injection had a 3% chance of encountering a fully seal offsetting fault.

54 ENVIRONMENTAL SCIENCES↗

Reduced defect density at the CZTSSe/CdS interface by atomic layer deposition of Al{sub 2}O{sub 3}

The greatest challenge for improving the power conversion efficiency of Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe)/CdS/ZnO thin film solar cells is increasing the open circuit voltage (V{sub OC}). Probable leading causes of the V{sub OC} deficit in state-of-the-art CZTSSe devices have been identified as bulk recombination, band tails, and the intertwined effects of CZTSSe/CdS band offset, interface defects, and interface recombination. In this work, we demonstrate the modification of the CZTSSe absorber/CdS buffer interface following the deposition of 1 nm-thick Al{sub 2}O{sub 3} layers by atomic layer deposition (ALD) near room temperature. Capacitance-voltage profiling and quantum efficiency measurements reveal that ALD-Al{sub 2}O{sub 3} interface modification reduces the density of acceptor-like states at the heterojunction resulting in reduced interface recombination and wider depletion width. Indications of increased V{sub OC} resulting from the modification of the heterojunction interface as a result of ALD-Al{sub 2}O{sub 3} treatment are presented. These results, while not conclusive for application to state-of-the-art high efficiency CZTSSe devices, suggest the need for further studies as it is probable that interface recombination contributes to reduced V{sub OC} even in such devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation performance of U-Mo monolithic fuel

High-performance research reactors require fuel that operates at high specific power to high fission density, but at relatively low temperatures. Research reactor fuels are designed for efficient heat rejection, and are composed of assemblies of thin-plates clad in aluminum alloy. The development of low-enriched fuels to replace high-enriched fuels for these reactors requires a substantially increased uranium density in the fuel to offset the decrease in enrichment. Very few fuel phases have been identified that have the required combination of very-high uranium density and stable fuel behavior at high burnup. U-Mo alloys represent the best known tradeoff in these properties. Testing of aluminum matrix U-Mo aluminum matrix dispersion fuel revealed a pattern of breakaway swelling behavior at intermediate burnup, related to the formation of a molybdenum stabilized high aluminum intermetallic phase that forms during irradiation. In the case of monolithic fuel, this issue was addressed by eliminating, as much as possible, the interfacial area between U-Mo and aluminum. Based on scoping irradiation test data, a fuel plate system composed of solid U-10Mo fuel meat, a zirconium diffusion barrier, and Al6061 cladding was selected for development. Developmental testing of this fuel system indicates that it meets core criteria for fuel qualification, including stable and predictable swelling behavior, mechanical integrity to high burnup, and geometric stability. In addition, the fuel exhibits robust behavior during power-cooling mismatch events under irradiation at high power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Potential Recoiling Supermassive Black Hole, CXO J101527.2+625911

We have carried out a systematic search for recoiling supermassive black holes (rSMBH) using the Chandra Source and SDSS Cross-Match Catalog. From the survey, we have detected a potential rSMBH, CXO J101527.2+625911, at z = 0.3504. The source CXO J101527.2+625911 has a spatially offset (1.26 ± 0.05 kpc) active SMBH and kinematically offset broad emission lines (175 ± 25 km s{sup −1} relative to the systemic velocity). The observed spatial and velocity offsets suggest that this galaxy could be an rSMBH, but we have also considered the possibility of a dual SMBH scenario. The column density toward the galaxy center was found to be Compton thin, but no X-ray source was detected. The non-detection of the X-ray source in the nucleus suggests that either there is no obscured actively accreting SMBH or that there exists an SMBH, but it has a low accretion rate (i.e., a low-luminosity AGN (LLAGN)). The possibility of the LLAGN was investigated and found to be unlikely based on the H α luminosity, radio power, and kinematic arguments. This, along with the null detection of an X-ray source in the nucleus, supports our hypothesis that CXO J101527.2+625911 is an rSMBH. Our GALFIT analysis shows the host galaxy to be a bulge-dominated elliptical. The weak morphological disturbance and small spatial and velocity offsets suggest that CXO J101527.2+625911 could be in the final stage of a merging process and about to turn into a normal elliptical galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlling electronic structure through epitaxial strain in ZnSe/ZnTe nano-heterostructures

Using first-principles computations, we study the effect of epitaxial strains on electronic structure variations across ZnSe/ZnTe nano-heterostructures. Epitaxial strains of various types are modeled using pseudomorphic ZnSe/ZnTe heterostructures. We find that a wide range of band gaps (spanning the visible solar spectrum) and band offsets (0–1.5 eV) is accessible across the heterostructures in a controllable manner via reasonable levels of epitaxial strain. In addition to quantum confinement effects, strain in ZnSe/ZnTe heterostructures may thus be viewed as a powerful degree of freedom that can enable the rational design of optoelectronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonuniform cosmological birefringence and active galactic nuclei

The CMB constrains the cosmological-birefringence rotation angle to be |{alpha}| < or approx. 1 deg. (1{sigma}) out to redshifts z{approx_equal}1100 for a rotation that is uniform across the sky. However, the rotation angle {alpha}({theta},{phi}) may vary with position ({theta},{phi}) on the sky, and if so, then it can be sought in current and future active galactic nuclei data. An upper limit <{alpha}{sup 2}>{sup 1/2} < or approx. 3.7 deg. to the scatter in the position-angle-polarization offsets in a sample of only N=9 active galactic nuclei already constrains the rotation spherical-harmonic coefficients to (4{pi}){sup -1/2{alpha}}{sub lm} < or approx. 3.7 deg. and constrains the power spectrum for {alpha} in models where it is a stochastic field. Future constraints can be improved with more sources and by analyzing well-mapped sources with a tensor-harmonic decomposition of the polarization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Band Alignment Transition in InAs/GaAsSb Quantum Dots by Photoluminescence

The band alignment of InAs quantum dots (QDs) embedded in GaAsSb barriers with various Sb compositions is investigated by photoluminescence (PL) measurements. InAs/GaAsSb samples with 13% and 15% Sb compositions show distinct differences in emission spectra as the PL excitation power increases. Whilst no discernible shift is seen for the 13% sample, a blue-shift of PL spectra following a 1/3 exponent of the excitation power is observed for the 15% sample suggesting a transition from a type I to type II band alignment. Time-resolved PL data show a significant increase in carrier lifetime as the Sb composition increases between 13% and 15% implying that the transformation from a type I to type II band alignment occurs between 13% and 15% Sb compositions. These results taken together lead to the conclusion that a zero valence band offset (VBO) can be achieved for the InAs/GaAsSb system in the vicinity of 14% Sb composition.

14 SOLAR ENERGY↗