Engineering an aldoxime dehydratase with high activity and isomer tolerance for biosynthesis of an O -protected primary cyanohydrin

O-protected primary cyanohydrins (glycolonitriles) are important building blocks for many difunctionalized compounds and precursors to known bioactive molecules. Their synthesis, however, utilizes toxic cyanide, which raises significant safety concerns for industrial synthesis. Here, in this study, we present a cyanide-free enzymatic synthesis of an o-benzyl protected primary cyanohydrin from an (E)- or (Z)-α-oxygen protected aldoxime using an engineered aldoxime dehydratase enzyme from Bacillus sp. OxB-1 (OxdB). In contrast to many evolved enzymes that tend to “specialize” as their activity increases, we used directed evolution to engineer OxdB for efficient dehydration of both isomers in a mixture of (E)- or (Z)-α-oxygen aldoximes with high activity and substrate loading to achieve near quantitative yield. Using this enzyme, we further demonstrate a cyanide-free chemoenzymatic pathway to an o-protected primary cyanohydrin starting from a readily available aldehyde, where the aldehyde is first condensed with hydroxylamine, followed by dehydration using our evolved enzyme. This pathway was readily scaled up to 1 g scale with high substrate loading, demonstrating its utility in industrial synthesis of these important building block functional groups.

Aldoxime dehydratase↗

An extremely durable redox shuttle additive for overcharge protection of lithium-ion batteries

Redox shuttle additives are used to protect lithium ion batteries from electrolyte oxidation and overheating during overcharge conditions. The additive protects the cell by becoming involved in a futile redox cycle that pins the cathode potential near the redox potential of the shuttle molecule. Since the material eventually becomes consumed in side reactions, high solubility of the parent molecule and high chemical stability of the charged molecule are required for durable protective action. Furthermore, we demonstrate a highly soluble (0.6 M) 1,4-dialkoxybenzene redox shuttle molecule that provides overcharge protection over 500 cycles at a C/2 rate and 100% overcharge ratio, which places this additive far ahead of the current state of the art.

1,4-Dialkoxybenzene↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

ZnTiN 2 as an Electron-Selective, Protective Layer on Si Photocathodes

Photoelectrochemical production of fuels requires photoelectrodes that efficiently convert sunlight to electrochemical energy by producing photovoltage and photocurrent and maintain this ability over time under a variety of pH, illumination, and applied bias conditions. Work in the photovoltaic community has demonstrated that interfaces with high charge carrier selectivity provide high photovoltages. This offers a co-design opportunity to create semiconductor photoelectrodes with contact layers that are both carrier-selective and offer protection from degradation in aqueous solutions. In this work, we explored the ternary nitride ZnTiN 2 as an electronselective, protective layer for Si-based photocathodes. We demonstrated that ZnTiN 2 formed a heterojunction with p-type Si that facilitated electron movement toward the ZnTiN 2 surface for light-driven reduction reactions. Across a variety of electrolyte conditions, ZnTiN 2 /Si produced an open circuit voltage of ca. 400 mV vs the solution potential, while bare Si produced 220−480 mV vs the solution potential depending on conditions. ZnTiN 2 was also shown to protect Si over 72 h at open circuit in the dark in 0.1 M KHCO 3 aqueous solution at pH 10.5, with a 2.4% loss in open circuit voltage compared to a 17% loss for unprotected Si. A protective effect was also observed under illumination during methyl viologen reduction at pH 3.5 for 21 h, with a 2.5% loss in open circuit voltage observed for ZnTiN 2 /Si compared to a 25% loss in open circuit voltage for unprotected Si under the same conditions. Elemental characterization revealed the presence of oxides on the surface of ZnTiN 2 that are consistent with the Pourbaix diagram after photoelectrochemical operation; these oxides appeared to support durability without hindering charge carrier extraction to drive electrochemical work. This work highlights the promise of ZnTiN 2 for durable photoelectrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport in magnetically doped one-dimensional wires: can the helical protection emerge without the global helicity?

We study the phase diagram and transport properties of arbitrarily doped quantum wires functionalized by magnetic adatoms. The appropriate theoretical model for these systems is a dense one-dimensional Kondo lattice (KL) which consists of itinerant electrons interacting with localized quantum magnetic moments. We discover the novel phase of the locally helical metal where transport is protected from a destructive influence of material imperfections. Paradoxically, such a protection emerges without a need of the global helicity, which is inherent in all previously studied helical systems and requires breaking the spin-rotation symmetry. We explain the physics of this protection of the new type, find conditions, under which it emerges, and discuss possible experimental tests. Our results pave the way to the straightforward realization of the protected ballistic transport in quantum wires made of various materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developing a Radiation Protection Hub

The WARP report issued by the NCRP study committee estimates that in ten years there will be a human capital crisis across the radiation safety community. The ability to respond to this shortage will be amplified by the fact that many radiation protection (health physics) academic programs will find it difficult to justify their continued existence since they are low volume programs, both in terms of enrollment and research funding, compared to the research funding return and visibility of more highly subscribed and highly funded academic disciplines. In addition, across the national laboratory complex, radiation protection research groups have been disbanded or dramatically reduced in size. The loss of both of these national resources is being accelerated by low and uncertain government funding priorities. The most effective solution to this problem would be to form a consortium that would bring together the radiation protection research, academic and training communities. The goal of such a consortium would be to engage in research, education and training of the next generation of radiation protection professionals. Furthermore the consortium could bring together the strengths of different universities, national laboratory programs and other entities in a strategic manner to accomplish a multifaceted research, educational and training agenda. This vision would forge a working and funded relationship between major research universities, national labs, four-year degree institutes, technical colleges and other partners.

consortium on radiation protection↗

Modeling of Protection in Dynamic Simulation Using Generic Relay Models and Settings

This paper shows how generic protection relay models available in planning tools can be augmented with settings that are based on NERC standards or best engineering practice. Selected generic relay models in Siemens PSS®E have been used in dynamic simulations in the proposed approach. Undervoltage, overvoltage, underfrequency, and overfrequency relays have been modeled for each generating unit. Distance-relay protection was modeled for transmission system protection. Two types of load-shedding schemes were modeled: underfrequency (frequency-responsive non-firm load shedding) and underfrequency and undervoltage firm load shedding. Several case studies are given to show the impact of protection devices on dynamic simulations. This is useful for simulating cascading outages.

cascading failures↗

Quench protection studies of the 11-T Nb 3 Sn dipole for the LHC upgrade

The planned upgrade of the LHC collimation system foresees additional collimators to be installed in the dispersion suppressor areas. Fermilab and CERN are developing an 11 T Nb 3 Sn dipole to replace some 8.33 T-15-m-long Nb-Ti LHC main dipoles providing longitudinal space for the collimators. In case of a quench, the large stored energy and the low copper stabilizer fraction make the protection of the 11 T Nb 3 Sn dipoles challenging. This paper presents the results of quench protection analysis, including quench protection heater design and efficiency, quench propagation and coil heating. The numerical results are compared with the experimental data from the 2-m-long Nb 3 Sn dipole models. Here, the validated model is used to predict the current decay and hot spot temperature under operating conditions in the LHC and the presently foreseen magnet protection scheme is discussed.

43 PARTICLE ACCELERATORS↗

A Cyber-Physical Anomaly Detection for Wide-Area Protection Using Machine Learning

Wide-area protection scheme (WAPS) provides system-wide protection by detecting and mitigating small and large-scale disturbances that are difficult to resolve using local protection schemes. As this protection scheme is evolving from a substation-based distributed remedial action scheme (DRAS) to the control center-based centralized RAS (CRAS), it presents severe challenges to their cybersecurity because of its heavy reliance on an insecure grid communication, and its compromise would lead to system failure. This article presents an architecture and methodology for developing a cyber-physical anomaly detection system (CPADS) that utilizes synchrophasor measurements and properties of network packets to detect data integrity and communication failure attacks on measurement and control signals in CRAS. The proposed machine leaning-based methodology applies a rules-based approach to select relevant input features, utilizes variational mode decomposition (VMD) and decision tree (DT) algorithms to develop multiple classification models, and performs final event identification using a rules-based decision logic. Here, we have evaluated the proposed methodology of CPADS using the IEEE 39 bus system for several performance measures (accuracy, recall, precision, and F-measure) in a cyber-physical testbed environment. Furthermore, our experimental results reveal that the proposed algorithm (VMD-DT) of CPADS outperforms the existing machine learning classifiers during noisy and noise-free measurements while incurring an acceptable processing overhead.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems

Pacific Northwest National Laboratory (PNNL) has performed an assessment of a Hybrid Plasma/Filter system as an alternative to conventional methods for collective protection. The key premise of the hybrid system is to couple a nonthermal plasma (NTP) reactor with reactive adsorption to provide a broader envelope of protection than can be provided through a single-solution approach. The first step uses highly reactive species (e.g. oxygen radicals, hydroxyl radicals, etc.) created in a nonthermal plasma (NTP) reactor to destroy the majority (~75% - 90%) of an incoming threat. Following the NTP reactor an O3 reactor/filter uses the O3 created in the NTP reactor to further destroy the remaining organic materials. This report summarizes the laboratory development of the Hybrid Plasma Reactor/Filter to protect against a ‘worst-case’ simulant, methyl bromide (CH3Br), and presents a preliminary engineering assessment of the technology to Joint Expeditionary Collective Protection performance specifications for chemical vapor air purification technologies.

99 GENERAL AND MISCELLANEOUS↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Nuclear Power Plant Physical Protection Recommendation Document

This document is aimed at providing guidance to the National Nuclear Security Administration’s (NNSA) Office of International Nuclear Security’s (INS) country and regional teams for implementing effective physical protection systems (PPSs) for nuclear power plants (NPPs) to prevent the radiological consequences of sabotage. This recommendation document includes input from the Physical Protection Functional Team (PPFT), the Response Functional Team (RFT), and the Sabotage Functional Team (SFT) under INS. Specifically, this document provides insights into increasing and sustaining physical protection capabilities at INS partner countries’ NPP sites. Nuclear power plants should consider that the intent of this document is to provide a historical context as well as technologies and methodologies that may be applied to improve physical protection capabilities. It also refers to relevant guidance from the International Atomic Energy Agency (IAEA) and the U.S. Nuclear Regulatory Commission (NRC).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reliable Protection for an Inverter-Based Resources Dominant Grid: Technology Development and Field Demonstration

The project aimed to address the challenges posed by the rapid growth of inverter-based resources (IBR) such as solar, wind, and battery storage, which have fundamentally changed fault behavior, system strength, and protection performance in bulk power systems. Traditional protection schemes, designed for synchronous generator-dominated grids, are inadequate under high IBR penetration. Overall, the project materially advances protection modeling and simulation capabilities needed to maintain reliable grid protection under high IBR penetration. The results build utility confidence in operating power systems safely and reliably across a wide range of generation mixes, supporting grid modernization goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

1.4.1.401 - Fish Protection Prize

The Fish Protection Prize sought new solutions, designs, and strategies to prevent fish from swimming into water infrastructure, such as water diversions and pipes and intakes at hydropower dams. Participants submitted innovative ideas to advance fish exclusion technology. WPTO collaborated with the U.S. Bureau of Reclamation on the Fish Protection Prize to inspire innovators to compete for $700,000 of combined cash prizes and voucher support to help protect fish from these threats. Five experts in fish passage and protection served as reviewers in the Pitch Contest, and represented a number of Federal and State agencies, including NOAA, USGS, ORNL, Washington Department of Fish and Wildlife, and AFS. Three finalists were selected as Grand Prize winners.

fish passage↗

Thermal protection barrier

A thermal protection barrier including a base layer having a high melting temperature granular media having free standing granules disposed within the base layer and a distributor grid layer having a plurality of spaced-apart distributors composed of a high melting temperature material disposed adjacent to the base layer. The spaced-apart distributors are dimensioned and configured to provide load bearing support to the thermal protection barrier prior to a breach of the thermal protection barrier and to divide and disperse a superheated flowing mass to the free standing granules of the base layer upon occurrence of a breach. In certain embodiments, the thermal protection barrier is positioned adjacent to a nuclear system such that, upon occurrence of a loss of containment accident, the distributor grid layer is positioned and configured to divide and disperse a superheated flowing nuclear mass to the free standing granules.

61 RADIATION PROTECTION AND DOSIMETRY↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Successful In Situ Remediation of Cr(VI)-Impacted Deeper Vadose Zone Soils for Groundwater Protection - 18603

Shallow soil at a former industrial wood treating facility was impacted with chromium, arsenic, and copper above cleanup goals and shallow soil has been excavated for protection of direct contact exposure pathways. Deeper vadose zone soil was predominantly impacted with chromium and was undergoing remediation for long-term groundwater protection. The 920-meter (m) long Cr(VI) groundwater plume has undergone full-scale remediation with groundwater recirculation and in situ bioremediation. Following approximately 4 years of operation, the Cr(VI) groundwater plume, with former source area groundwater concentrations over 10,000 micrograms per liter (μg/L), has been reduced to below the laboratory method reporting limit (0.50 μg/L). Approximately 23,000 cubic meters (m{sup 3}) of deeper (4.5 m - 11 m below ground surface, bgs) vadose zone soil required Cr(VI) remediation. The remediation strategy relied on reduction of Cr(VI) and geochemical fixation as trivalent chromium (Cr(III)) and iron hydroxide precipitates. Chromium reduction was facilitated by a carbon source (corn syrup and methanol) to establish and maintain biogeochemical reducing conditions and ferrous iron to support direct Cr(VI) chemical reduction. Combined, the injected soil moisture, carbon source and ferrous iron supported fast and sustained ferrous/ferric iron cycling and Cr(VI) reduction. Remedy performance monitoring included time-series water quality data from a network of vacuum lysimeters and confirmation soil borings. Reagent was applied either through liquid injection wells and direct-push injection points, or by deep soil mixing methodology in areas with difficult geology (i.e., fine-grained soils and discontinuous iron-silica hardpan layer). Following both phases of deep soil remediation, soils met long-term protection of groundwater remediation action objectives. In situ treatment of soils provides a cost-effective remedial solution compared to excavation, specifically when impacts are deep and long-term protection of groundwater is a primary remediation goal. The delivery methods employed in this case study can be applied to sites impacted with a broad range of contaminants amendable to geochemical fixation (e.g., chromium, uranium, strontium, nitrate, etc.). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗