Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

An inverse source location algorithm for radiation portal monitor applications

Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of particle deposition to and removal from clothing, skin, and hair after a radioactive airborne dispersal event

Explosive Radiological Dispersal Devices (RDD) – aka dirty bombs – are seen as a credible method to carry out a radiological terror attack. After exploding a radioactive source, the radionuclide-laden plume will be blown downwind of ground zero, with particles falling out and potentially depositing on people caught in and under the cloud. Some of these people may not show any sign of radiation sickness and therefore not realize they have been contaminated and may take the radioactive particulate with them on their daily activities, thus spreading the radioactive particulate outside the initially contaminated area. This paper reviews the scientific literature to better understand the rate at which particulate deposits on and is removed from the different “surfaces” of a person, i.e., hair, skin, and clothing. Prior research indicates that: 1) particle deposition is usually higher on skin than on hair and clothing; 2) particle deposition is greater for a person with higher skin moisture, 3) stronger wind increases the deposition flux onto a person, and 4) the fraction of particulate deposited on the hair, skin, and clothing respectively depends on the length of the hair, assuming all the hair surface is available for deposition. The studies taken into consideration show that the largest uncertainty in particulate deposition onto a person is due to clothing type because of the different possible weave arrangements and tightness which translate into differences in actual surface area and surface roughness. A factor of 2-to-20 variation in deposition rate was found. Removal of the particulate from the contaminated person may be due to wind, a person's movement, and/or contact transfer, i.e., by touching a different clean surface. Experiments show that the majority of the particulate is resuspended within 2–6 h mostly depending on the intensity of physical activity. The largest uncertainty in particulate removal from skin depends on the skin moisture, transfer rate of single-contact, and how many objects/people a person touches per hour. No data for hair were found for particle removal and resuspension. The studies considered did not utilize radionuclides directly; however, data on adhesion of radioactive vs. their non-radioactive counterpart have shown that the uncertainty due to the radioactivity of the particles is lower than that due to other factors. In conclusion, an idealized scenario involving a single building in the path of the cloud showed the impact of building-influenced flow on the cloud transport path and mixing, which affects the radiological dose the downwind population is exposed to and consequently the health effects.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Electrodeposition of actinide compounds from an aqueous ammonium acetate matrix. Experimental development and optimization

Electrodeposition is a technique that is routinely employed in nuclear research for the preparation of thin solid films of actinide materials which can be used in accelerator beam bombardments, irradiation studies, or as radioactive sources. The present study investigates the deposition of both lanthanides and actinides from an aqueous ammonium acetate electrolyte matrix. Electrodepositions were performed primarily on stainless steel disks; with yield analysis evaluated using -spectroscopy. Experimental parameters were studied and modified in order to optimize the uniformity and adherence of the deposition while maximizing the yield. The initial development utilized samarium as the plating material, with and without a radioactive tracer. As a result, surface characterization studies were performed by scanning electron microscopy, electron microprobe analysis, radiographic imaging, and x-ray diffraction.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CeSOX: Short-Distance Neutrino Oscillations with BoreXino

Several experimental anomalies in neutrino physics may point to the possible existence of one or more additional neutrino species that do not interact weakly, the so-called sterile neutrinos. The third phase of the Borexino experiment (SOX) is devoted to verification of this hypothesis. Within the first stage (CeSOX) the count rate of antineutrino events in the liquid scintillation detector from the artificial source {sup 1}44Ce–{sup 1}44Pr placed in the special pit beneath the setup will be measured. The smaller antineutrino flux, as compared to the original one, would indicate the presence of oscillations into sterile states. This paper gives a survey of the CeSOX experiment, including the general description, the characterization of the radioactive source and the specific features of its use, the description of the method for data analysis, and the expected results. Depending on the significance of the obtained scientific information, the decision on carrying out the second stage of the SOX experiment with the {sup 51}Cr source of electron neutrinos will be made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation protection and instrumentation

Radiation was found not to be an operational problem during the Apollo program. Doses received by the crewmen of Apollo missions 7 through 17 were small because no major solar-particle events occurred during those missions. One small event was detected by a radiation sensor outside the Apollo 12 spacecraft, but no increase in radiation dose to the crewmen inside the spacecraft was detected. Radiation protection for the Apollo program was focused on both the peculiarities of the natural space radiation environment and the increased prevalence of manmade radiation sources on the ground and onboard the spacecraft. Radiation-exposure risks to crewmen were assessed and balanced against mission gain to determine mission constraints. Operational radiation evaluation required specially designed radiation detection systems onboard the spacecraft in addition to the use of satellite data, solar observatory support, and other liaison. Control and management of radioactive sources and radiation-generating equipment was important in minimizing radiation exposure of ground-support personnel, researchers, and the Apollo flight and backup crewmen.

J. Vernon Bailey↗

Measurement of low energy ionization signals from Compton scattering in a charge-coupled device dark matter detector [Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector]

In this paper, an important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental γ rays. We report detailed measurements of low-energy spectra from Compton scattering of γ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by γ rays from 57 Co and 241 Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically motivated parametrization of the data that describes the Compton spectrum at low energies for any incident γ-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave profiling of snowpack free-water content

A microwave system is proposed to measure the amount of liquid-phase water in a snowpack operating in the range of 1 to 10 GHz. Attenuation of the beam between source and receivers is produced by the water in the snow. The relationships of frequency, distance, and volume percent of water are calculated for an assumed detector sensitivity, together with the estimated cost of a representative system. A laboratory test is described that shows the attenuation for snow at maximum wetness at 9.35 GHz. A configuration is proposed that involves a vertical tube containing microwave and radioactive sources and another vertical tube containing microwave and gamma-ray detectors, so that density and wetness profiles are obtained simultaneously over essentially the same path.

Linlor, W. I.↗

Safety assessment for the radon-type surface disposal facility at Saakadze, Georgia - 15406

The Saakadze disposal facility is located about 40 km from Tbilisi and was planned and constructed during Soviet times as Radon-type surface facility to accommodate up to 600 m{sup 3} of low and intermediate level waste generated on the territory of Georgia. The disposal facility was operated from 1963 until its closure in 1995. The vast majority of waste in the Saakadze facility has been disposed of in two near surface concrete vaults with typical Radon-type dimensions, which cover layers already show significant structural damages. In order to assess the present safety of the site and provide the competent Georgian authorities with the necessary basis to take decisions in regard to the future of the repository, the European Commission launched and financially supported a project, which was assigned to a consortium of TUV-Nord ENSYS GmbH and DBE Technology GmbH. The safety assessment of Saakadze facility, which was an essential part of this project and which is the subject of this paper was carried out by DBE Technology GmbH. The Government of Georgia has been gradually increasing efforts to improve the regulatory processes and the legislation on nuclear and radiation safety, and, in particular, on safe management of radioactive waste and sealed radioactive sources. Currently, however, there are still areas where specific Georgian laws and regulations do not exist. Accordingly, in certain aspects IAEA recommendations and best practices were used as guidelines for the methodology of the safety assessment. In spite of the large uncertainties to be considered, especially in regard to the inventory, preliminary results of the safety assessment indicate that scenarios related to the groundwater pathway do not lead to radiological impacts that are above or near to limiting values. However, human intrusion scenarios might lead to dose rates for the critical group that are exceeding these values. This is mainly due to the fact that today there is no proper engineered cover on top of the concrete vaults. Based on the comparison of existing options and considering the results of the long-term safety assessment, it is recommended to backfill the remaining voids inside the concrete vaults and to construct an engineered cover to reduce the probability of human intrusion scenarios and to minimize their potential impact. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portland cement paste behaviour under gamma radiation field in geological repository - 15272

The Radioactive Waste Management Laboratory at the Nuclear and Energy Research Institute in Sao Paulo, Brazil (IPEN-CNEN-SP), is developing the concept of a repository for disposition of disused sealed radioactive sources in a deep borehole in which cement paste is intended to be used as a backfill between the steel casing and the geological formation around the borehole. The cement paste is intended to function as structural material, a blockage against the transport of water between the different strata of the geological setting, and as an additional barrier against the migration of radionuclides. The assessment of the cement paste behaviour in long term is necessary to increase the confidence that the material will perform as required during the service life of the facility. Under radiation, pore water present in cement paste suffers radiolysis and some products can be highly reactive, as electrons and hydroxyl radicals and hydrogen peroxide. These radiolysis products will interact with cement paste and its hydration products, forming a wide range of compounds. Previous work focused on assessing the synergic effects of radiation and environmental conditions, like higher temperature and aggressive groundwater chemicals, on cement paste. Examination of samples detected small differences in mineralogy and microstructure. However, the radiation dose to which samples were exposed (400 kGy) was only a fraction of the expected accumulated dose in cement paste until complete decay of some sealed sources in the repository. Therefore, several thousand kilo-grays must be tested the possibility of radiation to alter cement mineralogy and, as a consequence, its durability The objective of this research is to evaluate the changes in mineralogy and microstructure of irradiated cement paste specimens, in an attempt to establish a relationship between irradiation and durability. Cubic Portland cement specimens were casted and exposed to the gamma radiation of a 60 Co multipurpose irradiator, at IPEN-CNEN/SP. The effects of doses between 1000 kGy and 4000 kGy are evaluated by X-Ray Diffraction, Scanning Electron Microscopy, X-ray micro tomography, neutrongraphy and neutron scattering. This report presents the changes in cement paste mineralogy when samples are examined by XRD. Results indicate that durability can be affected because of the observed changes. Results are expected to indicate the induced changes in cement paste under high radiation doses and to provide hints on its behaviour in the long-term and service-life. The results can be used in safety analysis for deep geological repositories that use cement based materials as engineered barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of a Position-Sensitive Multi-Anode Photomultiplier Tube for Finding Gamma-Ray Source Direction

In an urban environment where gamma-ray background counts vary rapidly, it is important to determine the angle (with respect to the detector system) of a discrete gamma-ray–emitting source for localization purposes. We have recently developed a handheld gamma-ray detection system that provides gamma-ray energy spectral data and angular position of the target source. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. The objectives of this project were to design and build a prototype, light-weight, hand-held, gamma-ray spectrometer with directional sensitivity. It is important for first responders in a radiological emergency to have an easy-to-use gamma spectrometric detection system that determines the incident gamma-ray energy along with the relative angular position of a point-like radioactive source in a near-field measurement (≤3 meters from the source). The technical challenge of this project, driven by search scenarios for monitoring crowds in a national special security events was to determine the relative angle of a gamma-ray–emitting source (50 μCi strong) at a distance of 3 meters from the detector in 3 minutes. We designed and built small, portable, light-weight directional gamma energy spectrometers using a position-sensitive multi-anode photomultiplier. All of three spectrometers showed remarkable (ΔΘ = ± 2°) sensitivity to relative angular position of the source in near-field laboratory measurements.

position-sensitive photomultiplier tube (PMT), mul↗

An overview of the global threat reduction initiative's physical protection work in Tanzania.

The U.S. Department of Energy's (DOE) National Nuclear Security Administration (NNSA) established the Global Threat Reduction Initiative's (GTRI) mission to reduce and protect nuclear and radiological materials located at civilian sites worldwide. Internationally, over 80 countries are cooperating with GTRI to enhance security of facilities with these materials. In 2004, a GTRI delegation began working with the Tanzania Atomic Energy Commission, (TAEC). The team conducted site assessments for the physical protection of radiological materials in Tanzania. Today, GTRI and the Government of Tanzania continue cooperative efforts to enhance physical security at several radiological sites, including a central sealed-source storage facility, and sites in the cities of Arusha, Dar Es Salaam, and Tanga. This paper describes the scope of physical protection work, lessons learned, and plans for future cooperation between the GTRI program and the TAEC. Additionally the paper will review the cooperative efforts between TAEC and the International Atomic Energy Agency (IAEA) with regards to a remote monitoring system at a storage facility and to the repackaging of radioactive sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Priorities for technology development and policy to reduce the risk from radioactive materials.

The Standing Committee on International Security of Radioactive and Nuclear Materials in the Nonproliferation and Arms Control Division conducted its fourth annual workshop in February 2010 on Reducing the Risk from Radioactive and Nuclear Materials. This workshop examined new technologies in real-time tracking of radioactive materials, new risks and policy issues in transportation security, the best practices and challenges found in addressing illicit radioactive materials trafficking, industry leadership in reducing proliferation risk, and verification of the Nuclear Nonproliferation Treaty, Article VI. Technology gaps, policy gaps, and prioritization for addressing the identified gaps were discussed. Participants included academia, policy makers, radioactive materials users, physical security and safeguards specialists, and vendors of radioactive sources and transportation services. This paper summarizes the results of this workshop with the recommendations and calls to action for the Institute of Nuclear Materials Management (INMM) membership community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UAVs for Radiological Monitoring: Determining Ideal Operational Parameters From GEANT4 Simulations - 18025

Owing in no small part to the enormous advances in radiation detector technology (size, sensitivity and spectral-resolution), there has been an increased drive and requirement to accurately map both the spatial extent and magnitude of radiological contamination at the greatest possible spatial resolutions. To undertake this, a range of different methods have been devised and include the use of cars and human, but also planes (and more recently) unmanned aerial vehicles (UAVs). However, critical to the remote sensing using such UAVs in contrast to ground-based sensing, is (i) the selection of the ideal operational parameters to attain the best on-ground resolution in addition to, (ii) understanding the correct normalisation procedures and other influences on results that surveys at these reduced altitudes might present. Resulting from earlier works, through employing combined modelling and experimental data, the optimal height for a UAV survey using the more realistic 'area' radioactive source term (opposed to an infinitely-small 'point-source') is determined to be approximately 5 m - suitably maximizing cross detector counts. At greater altitudes than this, the influence of variations in neighboring topology / topography and nearby structures are observed to be negligible. However, at this and further-reduced altitudes (where optimal count-rates exists), small height-related variations are observed to result, and impact considerably on the complexity of the data normalisation. Whilst not occurring as a tool to entirely replace ground-based surveys, UAV systems are able to perform in challenging or dangerous environments, inadvisable or problematic to send humans. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the use of a single-fiber multipoint plastic scintillation detector for {sup 192}Ir high-dose-rate brachytherapy

Purpose: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during {sup 192}Ir high-dose-rate brachytherapy treatments.Methods: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested.Results: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 {+-} 2.1%, 3.0 {+-} 0.7%, and 4.5 {+-} 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 {+-} 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction.Conclusions: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Detection and Dual-Energy X-Ray Imaging for Port Security

Millions of cargo containers are transported across the United States border annually and are inspected for illicit radioactive material and contraband using a combination of passive radiation portal monitors (RPM) and high energy X-ray non-intrusive inspection (NII) systems. As detection performance is expected to vary with the material composition of cargo, characterizing the types of material present in cargo is important to national security. This work analyzes the passive radiation and dual energy radiography signatures from on RPM and two NII system, respectively. First, the cargos were analyzed to determine their ability to attenuate emissions from an embedded radioactive source. Secondly, dual-energy X-ray discrimination was used to determine the material composition and density of the cargos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results with a micro-cavity plasma panel detector

During the three last years, a complete study of a radiation detector based on plasma panel technology (main component of plasma television display) has been completed using source, cosmic ray and beam. This studies showed a fast response (O(5 ns)), high spatial resolution detection of ionizing particle and minimum ionizing particles. It shows very promising results in term of pixel-to-pixel uniformity and time stability of both signal shapes and rates. The prototype has also demonstrated very low background over a wide range of applied high voltages, excellent pixel response isolation, time resolutions of a few nanoseconds, and efficiencies above 95% over a 100-volt range for beta particles emitted by a {sup 106}Ru radioactive source. A full report will be presented (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Global Threat Reduction Initiative's Orphan Source Recovery Project in the Russian Federation

After 9/11, officials at the United States Department of Energy (DOE), National Nuclear Security Administration (NNSA) grew more concerned about radiological materials that were vulnerable to theft and illicit use around the world. The concern was that terrorists could combine stolen radiological materials with explosives to build and detonate a radiological dispersal device (RDD), more commonly known as a “dirty bomb.” In response to this and other terrorist threats, the DOE/NNSA formed what is now known as the Global Threat Reduction Initiative (GTRI) to consolidate and accelerate efforts to reduce and protect vulnerable nuclear and radiological materials located at civilian sites worldwide. Although a cooperative program was already underway in the Russian Federation to secure nuclear materials at a range of different facilities, thousands of sealed radioactive sources remained vulnerable at medical, research, and industrial sites. In response, GTRI began to focus efforts on addressing these materials. GTRI’s Russia Orphan Source Recovery Project, managed at the Nevada National Security Site’s North Las Vegas facility, was initiated in 2002. Throughout the life of the project, Joint Stock Company “Isotope” has served as the primary Russian subcontractor, and the organization has proven to be a successful partner. Since the first orphan source recovery of an industrial cobalt-60 irradiator with 647 curies (Ci) at an abandoned facility in Moscow in 2003, the GTRI Orphan Source Recovery Project in the Russian Federation has accomplished substantial levels of threat reduction. To date, GTRI has recovered and securely disposed of more than 5,100 sources totaling more that 628,000 Ci. This project serves as an extraordinary example of how international cooperation can be implemented by partners with mutual interests to achieve significant goals.

GTRI, Global Threat Reduction Initiative, Russian ↗

High-Energy Calibration of a BGO Detector of the GLAST Burst Monitor

The understanding of the instrumental response of the GLAST Burst Monitor BGO detectors at energies above the energy range which is accessible by common laboratory radiation sources (< 4.43 MeV), is important, especially for the later cross-calibration with the LAT response in the overlap region between {approx}20 MeV to 30 MeV. In November 2006 the high-energy calibration of the GBM-BGO spare detector was performed at the small Van-de-Graaff accelerator at SLAC. High-energy gamma-rays from excited {sup 8}Be* (14.6 MeV and 17.5 MeV) and {sup 16}O* (6.1 MeV) were generated through (p, {gamma})-reactions by irradiating a LiF-target. For the calibration at lower energies radioactive sources were used. The results, including spectra, the energy/channel-relation and the dependence of energy resolution are presented.

43 PARTICLE ACCELERATORS↗