Search NASA⌕ Search

SEARCH · Search NASA

Results for “RODS - TORSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Abrasive drill for resilient materials

Resilient materials normally present problem in obtaining accurate and uniform hole size and position. Tool is fabricated from stiff metal rod such as tungsten or carbon steel that has diameter slightly smaller than required hole. Piercing/centering point is ground on one end of rod. Rod is then plasma-sprayed (flame-sprayed) with suitable hard abrasive coating. High-speed, slow-feed operation of tool is necessary for accurate holes, and this can be done with drill press, hard drill, or similar machines.

Koch, A. J.↗

Testing of the permanent magnet material Mn-Al-C for potential use in propulsion motors for electric vehicles

The development of Mn-Al-C permanent magnets is reviewed. The general properties of the material are discussed and put into perspective relative to alnicos and ferrites. The traction motor designer's demands of a permanent magnet for potential use in electric vehicle drives are reviewed. Tests determined magnetic design data and mechanical strength properties. Easy axis hysteresis and demagnetization curves, recoil loops and other minor loop fields were measured over a temperature range from -50 to 150 C. Hysteresis loops were also measured for three orthogonal directions (the one easy and two hard axes of magnetization). Extruded rods of three different diameters were tested. The nonuniformity of properties over the cross section of the 31 mm diameter rod was studied. Mechanical compressive and bending strength at room temperature was determined on individual samples from the 31 mm rod.

Abdelnour, Z.↗

A two-degree-of-freedom flutter mount system with low damping for testing rigid wings at different angles of attack

A wind tunnel model mount system for conducting flutter research using a rigid wing was developed. The wing is attached to a splitter plate so that the two move as one rigid body. The splitter plate is supported away from the tunnel wall by a system of rods with fixed fixed and conditions. The rods flex in such a way that only pitch and plunge oscillations are permitted. At the tunnel wall the rods are attached to a remotely controlled turntable so that angle of attack can be varied. Wind tunnel data obtained by using the mount system are presented for a supercritical and a conventional airfoil. Both classical flutter and stall flutter data are presented.

Farmer, M. G.↗

Structural Turnbuckle Bears Compressive or Tensile Loads

Column length adjuster based on turnbuckle principle. Device consists of internally and externally threaded bushing, threaded housing and threaded rod. Housing attached to one part and threaded rod attached to other part of structure. Turning double threaded bushing contracts or extends rod in relation to housing. Once adjusted, bushing secured with jamnuts. Device used for axially loaded members requiring length adjustment during installation.

Bateman, W. A.↗

Reduced thermal focusing and birefringence in zig-zag slab geometry crystalline lasers

The present investigation is concerned with interferometric measurements of the thermally induced optical effects in laser crystals, taking into account crystals cut in both the zig-zag slab and the conventional rod geometries. The measurements conducted demonstrate the significant advantages obtained by replacing the rod in a Nd:YAG laser with a slab. A description is provided of simple measures designed to eliminate end and edge effects, and efficiency and threshold data for the Nd:YAG slab and the rod it replaced are presented. The only disadvantage is a small increase in cost due to the more difficult fabrication of the slab and the greater amount of Nd:YAG which is needed to allow the ends to be unpumped.

Kane, T. J.↗

Adhesive-Bonded Fixture for Flexure Testing

Fixture for flexural tests of glass-fiber-reinforced epoxy rods 1/4 in. (6.4 mm) in diameter easy to fabricate. Little machining done by relatively unskilled. Flexural-test fixture allows bending stress applied to specimen rod while holding rod securely. Dowel pins, blocks, and plate that make up fixture joined by adhesive.

Clemons, J. M.↗

Dent-Removing Tool

Small dents in metal parts and structures evened out quickly with aid of simple tool. User first tack welds tip of slide rod to dent. Next, user slides hammer away from dent so hammer strikes flange at end of rod. Impact of hammer pulls out dent. Hammering repeated until dented metal even with surrounding surface. Slide rod unwelded, and surface finish restored.

Leipham, T.↗

Coupled translations of the 64-meter antenna subreflector supports

The Tricone subreflector assembly of the 64-m diameter antenna is supported from the apex of the quadripod by six flexure rods. The subreflector can be translated in the three orthogonal axes by jackscrews at the ends of each rod. The arrangement of the six rods is described and analysis of the position errors introduced by coupled translation is presented. The results indicate that negligible RF gain losses caused by axis-coupled translations (less than 0.05 dB) are possible at X-band (8.45 GHz) operation.

Katow, M. S.↗

Portable 90 degree proof loading device

A hydraulically actuated device is described for applying a test load to a bearing or the like to prove the integrity of its mounting or staking within a bore in a housing such as gear case. To accommodate limited access situations, the device is constructed in a right angle configuration in which a hydraulic cylinder applies axial pressure to a first thrust rod assemly which includes a first thrust rod through a threated spindle driving a linearly translated cam. Cam follower wheel transfers the translation to a second thrust rod assembly which includes a horizontal shaft and a spindle within a cross-arm housing portion and a tubular housing portion. The same second thrust direction applies the bearing loading in either of two directions depending upon the shape of the interface parts. The interface parts can bear on the bearing from either side with respect to the bearing mounting structural part.

Bird, R. G.↗

Flow visualization of acoustic levitation experiment

Acoustic levitation experiments for space applications were performed. Holographic interferometry is being used to study the heat transfer rates on a heated rod enclosed in a 6 cu in chamber. Acoustic waves at levels up to 150 db increased the heating rates to the rod by factors of three to four. High speed real time holographic interferometry was used to measure the boundary layer on the heated rod. Data reduction and digitization of the interferograms are being implemented.

Baroth, ED↗

Directional solidification and characterization of near eutectic Sm2CO17/Co alloys

The effects of directional solidification processing on the microstructural, compositional, and magnetic properties of near eutectic Co-Sm alloys (about 9 at. pct Sm) have been studied. Initial investigations have been performed at modest thermal gradients in the liquid, G(L) less than 60 C/cm and over a range of furnace (solidification) velocities, V = 0.8 45.4 cm/h. The primary dendrite spacing for near eutectic Sm2Co17/Co scaled with 1/sq rt V and varied from about 50 microns for V greater than or equal to 20 cm/h to hundreds of microns for V less than 10 cm/h, while the rod eutectic diameter and interrod spacing were an order of magnitude smaller. For both dendritic and cooperative growth, the associated permanent magnet properties were rather poor, e.g., remanence less than 4 kG and coercive force less than 1 kOe for the smallest dendrite and rod diameter dimensions encountered, although the magnetic hardness for the rod eutetic was larger than for the dendritic microstructure. Magnetization as a function of sample orientation indicated that the easy axis of magnetization was primarily along the direction of solidification for both ferromagnetic phases.

Pirich, Ronald G.↗

Linear-Alignment Testing Grips

Lateral movements of grips are eliminated for thin speciments. Design integrates linear bearings with close-tolerance matching rods into gripping chain. Rods fixed into load-measurement grip, load-applicator grip slides along them. Rods do not interfere with force being applied but prevent lateral motion of one grip relative to other.

Gardner, Mickey R.↗

Bistable direction switching in an off-axis pumped continuous wave ruby laser

A report is presented of the observation of hysteretic bistable direction switching in a single-mode CW ruby laser system. This effect is only observed when the pump beam which is focused into the ruby rod is misaligned with respect to the rod end faces. At low pump powers, the ruby lases in a mode nearly collinear with the pump axis. At a higher pump power the ruby switches to a mode that is collinear with the rod end faces and preserves the original polarization. The effect is large enough to switch the beam by an angle equal to twice the diffraction angle. The observations show that under steady-state pumping, a CW ruby laser can exhibit bistable operation in its output direction and power. A calculation using the heat equation with two concentric cylinders with one as a heat source (pump laser) and the outer wall of the other held at 77 K, gives an increase in core temperature of about 0.01 K. Therefore, the increase in temperature is not large enough to change the index of refraction to account for such large macroscopic effects.

Afzal, R. Sohrab↗

Relevance of impacter shape to nonvisible damage and residual tensile strength of a thick graphite/epoxy laminate

A study was made to determine the relevance of impacter shape to nonvisible damage and tensile residual strength of a 36 mm (1.4 in.) thick graphite/epoxy motor case. The shapes of the impacters were as follows: 12.7 mm (0.5 in.) and 25.4 mm (1.0 in.) diameter hemispheres, a sharp corner, and a 6.3 mm (0.25 in.) diameter bolt-like rod. The investigation revealed that damage initiated when the contact pressure exceeded a critical level. However, the damage was not visible on the surface until an even higher pressure was exceeded. The damage on the surface consisted of a crater shaped like the impacter, and the damage below the surface consisted of broken fibers. The impact energy to initiate damage or cause visible damage on the surface increased approximately with impacter diameter to the third power. The reduction in strength for nonvisible damage increased with increasing diameter, 9 and 30 percent for the 12.7 mm (0.5 in.) and 25.4 mm (1.0 in.) diameter hemispheres, respectively. The corner impacter made visible damage on the surface for even the smallest impact energy. The rod impacter acted like a punch and sliced through the composite. Even so, the critical level of pressure to initiate damage was the same for the rod and hemispherical impacters. Factors of safety for nonvisible damage increased with increasing kinetic energy of impact. The effects of impacter shape on impact force, damage size, damage visibility, and residual tensile strength were predicted quite well assuming Hertzian contact and using maximum stress criteria and a surface crack analysis.

Poe, C. C., Jr.↗

Lunar drill footplate and casing

To prevent hole collapse during lunar drilling operations, a casing has been devised of a graphite reinforced polyimide composite which will be able to withstand the lunar environment. Additionally, this casing will be inserted into the ground in segments two meters long which will penetrate the regolith simultaneously with the auger. The vertical action of the mobile platform will provide a downward force to the casing string through a special adaptor, giving the casing the needed impetus to sink the anticipated depth of ten meters. Casing segments will be connected with a simple snap arrangement. Excess casing will be cut off by a cylindrical cutting tool which will also transport the excess casing away from the hole. A footplate will be incorporated to grasp the auger rod string during rod segment additions or removals. The footplate grasping mechanism will consist of a set of vice-like arms, one end of each bearing threaded to a common power screw. The power screw will be threaded such that one end's thread pitch opposes that of the other end. The weight of the auger and rod string will be transmitted through the arms to the power screw and absorbed by a set of three ball bearing assemblies. The power screw will be driven by a one-half horsepower brushless motor actuated by radio control. The footplate will rest on four short legs and be anchored with pins that are an integral part of each leg.

Maassen, Erik C.↗

Potential of solar-simulator-pumped alexandrite lasers

An attempt was made to pump an alexandrite laser rod using a Tamarak solar simulator and also a tungsten-halogen lamp. A very low optical laser cavity was used to achieve the threshold minimum pumping-power requirement. Lasing was not achieved. The laser threshold optical-power requirement was calculated to be approximately 626 W/sq cm for a gain length of 7.6 cm, whereas the Tamarak simulator produces 1150 W/sq cm over a gain length of 3.3 cm, which is less than the 1442 W/sq cm required to reach laser threshold. The rod was optically pulsed with 200 msec pulses, which allowed the alexandrite rod to operate at near room temperature. The optical intensity-gain-length product to achieve laser threshold should be approximately 35,244 solar constants-cm. In the present setup, this product was 28,111 solar constants-cm.

Deyoung, Russell J.↗

Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

Jensen, S. K.↗

Faraday polarization fluctuations of satellite beacon signals

The anisotropic effects of random density irregularities in causing Faraday polarization fluctuations of VHF radio signals are examined, taking both rod-like and sheet-like irregularities into consideration. It is found that the variance of Faraday polarization fluctuations depends on the ratio of perpendicular to parallel correlation lengths. The anisotropic effect of rod-like ionospheric irregularities are shown to be most appreciable for longitudinal propagation. The anisotropic effect of sheet-like ionospheric irregularities, however, is not strongly dependent on the radio propagation angle. During transionospheric propagation at large angles with respect to the geomagnetic field, sheet-like irregularities may cause greater Faraday polarization fluctuations than rod-like irregularities.

Lee, M. C.↗