Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Investigation of Atmospheric Effects in Image Transfer

Several computations on radiation emerging from the atmosphere for different aerosol models have been performed and the reflection matrix of a given surface was defined by incident light signature analyses. A two channel polarimeter is being constructed for measuring the Stokes parameters of reflected light. Surface albedo measurements were made in six wavelength ranges in the ultraviolet, visible, and near infrared spectral regions for six different vegetated surfaces, four soil surfaces, and two roadway surfaces. The effects of polarization changes on the intensity of projected images were studied by using a rotatable polarizer in front of an aerial camera lens.

Coulson, K. L.↗

Two-dimensional image edge enhancement using two orders of Bragg diffraction

The process of two-dimensional image edge enhancement with an acousto-optical spatial filter using two orders of light diffraction is studied. It is theoretically shown that the diffraction that occurs in a paratellurite crystal on a ‘slow’ acoustic wave propagating orthogonally to the optical axis of the crystal allows enhancing a two-dimensional edge of an image, transferred by optical radiation with a wavelength of 0.63 μm in a wide band of acoustic frequencies 25 – 50 MHz. Enhancement of a two-dimensional image edge at an acoustic frequency of 29 MHz is experimentally demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The application of color display techniques for the analysis of Nimbus infrared radiation data

A color enhancement system designed for the Applications Technology Satellite (ATS) spin scan experiment has been adapted for the analysis of Nimbus infrared radiation measurements. For a given scene recorded on magnetic tape by the Nimbus scanning radiometers, a virtually unlimited number of color images can be produced at the ATS Operations Control Center from a color selector paper tape input. Linear image interpolation has produced radiation analyses in which each brightness-color interval has a smooth boundary without any mosaic effects. An annotated latitude-longitude gridding program makes it possible to precisely locate geophysical parameters, which permits accurate interpretation of pertinent meteorological, geological, hydrological, and oceanographic features.

Allison, L. J.↗

High resolution imaging with multilayer soft X-ray, EUV and FUV telescopes of modest aperture and cost

The development of multilayer reflective coatings now permits soft X-ray, EUV and FUV radiation to be efficiently imaged by conventional normal incidence optical configurations. Telescopes with quite modest apertures can, in principle, achieve images with resolutions which would require apertures of 1.25 meters or more at visible wavelengths. The progress is reviewed which has been made in developing compact telescopes for ultra-high resolution imaging of the sun at soft X-ray, EUV and FUV wavelengths, including laboratory test results and astronomical images obtained with rocket-borne multilayer telescopes. The factors are discussed which limit the resolution which has been achieved so far, and the problems which must be addressed to attain, and surpass the 0.1 arc-second level. The application of these technologies to the development of solar telescopes for future space missions is also described.

Walker, Arthur B. C., Jr.↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

Serial femtosecond and serial synchrotron crystallography can yield data of equivalent quality: A systematic comparison

For the two proteins myoglobin and fluoroacetate dehalogenase, we present a systematic comparison of crystallographic diffraction data collected by serial femtosecond (SFX) and serial synchrotron crystallography (SSX). To maximize comparability, we used the same batch of micron-sized crystals, the same sample delivery device, and the same data analysis software. Overall figures of merit indicate that the data of both radiation sources are of equivalent quality. For both proteins, reasonable data statistics can be obtained with approximately 5000 room-temperature diffraction images irrespective of the radiation source. The direct comparability of SSX and SFX data indicates that the quality of diffraction data obtained from these samples is linked to the properties of the crystals rather than to the radiation source. Therefore, for other systems with similar properties, time-resolved experiments can be conducted at the radiation source that best matches the desired time resolution.

59 BASIC BIOLOGICAL SCIENCES↗

Infrared imaging - A validation technique for computational fluid dynamics codes used in STOVL applications

The need for a validation technique for computational fluid dynamics (CFD) codes in STOVL applications has led to research efforts to apply infrared thermal imaging techniques to visualize gaseous flow fields. Specifically, a heated, free-jet test facility was constructed. The gaseous flow field of the jet exhaust was characterized using an infrared imaging technique in the 2 to 5.6 micron wavelength band as well as conventional pitot tube and thermocouple methods. These infrared images are compared to computer-generated images using the equations of radiative exchange based on the temperature distribution in the jet exhaust measured with the thermocouple traverses. Temperature and velocity measurement techniques, infrared imaging, and the computer model of the infrared imaging technique are presented and discussed. From the study, it is concluded that infrared imaging techniques coupled with the radiative exchange equations applied to CFD models are a valid method to qualitatively verify CFD codes used in STOVL applications.

Hardman, R. R.↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

The Juno Magnetic Field Investigation

The Juno Magnetic Field investigation (MAG) characterizes Jupiter's planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor suites, each consisting of a tri-axial Fluxgate Magnetometer (FGM) sensor and a pair of co-located imaging sensors mounted on an ultra-stable optical bench. The imaging system sensors are part of a subsystem that provides accurate attitude information (to approx. 20 arcsec on a spinning spacecraft) near the point of measurement of the magnetic field. The two sensor suites are accommodated at 10 and 12 m from the body of the spacecraft on a 4 m long magnetometer boom affixed to the outer end of one of 's three solar array assemblies. The magnetometer sensors are controlled by independent and functionally identical electronics boards within the magnetometer electronics package mounted inside Juno's massive radiation shielded vault. The imaging sensors are controlled by a fully hardware redundant electronics package also mounted within the radiation vault. Each magnetometer sensor measures the vector magnetic field with 100 ppm absolute vector accuracy over a wide dynamic range (to 16 Gauss = 1.6 x 10(exp. 6) nT per axis) with a resolution of approx. 0.05 nT in the most sensitive dynamic range (+/-1600 nT per axis). Both magnetometers sample the magnetic field simultaneously at an intrinsic sample rate of 64 vector samples per second. The magnetic field instrumentation may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. The attitude determination system compares images with an on-board star catalog to provide attitude solutions (quaternions) at a rate of up to 4 solutions per second, and may be configured to acquire images of selected targets for science and engineering analysis. The system tracks and catalogs objects that pass through the imager field of view and also provides a continuous record of radiation exposure. A spacecraft magnetic control program was implemented to provide a magnetically clean environment for the magnetic sensors, and residual spacecraft fields andor sensor offsets are monitored in flight taking advantage of Juno's spin (nominally 2 rpm) to separate environmental fields from those that rotate with the spacecraft.

Juno spacecraft↗

Integrated infrared and visible image sensors

Semiconductor imaging devices integrating an array of visible detectors and another array of infrared detectors into a single module to simultaneously detect both the visible and infrared radiation of an input image. The visible detectors and the infrared detectors may be formed either on two separate substrates or on the same substrate by interleaving visible and infrared detectors.

Fossum, Eric R.↗

Infrared Images

Earth objects emit natural radiation invisible to the unaided human eye, but visible to infrared scanning devices such as the device developed by Inframetrics, Inc. Such devices serve a number of purposes ranging from detection of heat loss in buildings for energy conservation measures, to examining heat output of industrial machinery for trouble shooting and preventive maintenance. Representative of system is Model 525, a small, lightweight field instrument that scans infrared radiation and translates its findings to a TV picture of the temperature pattern in the scene being viewed. An accessory device permits viewing the thermal radiation in color.

Source record↗

Jipole: A Differentiable ipole-based Code for Radiative Transfer in Curved Spacetimes

Recent imaging of supermassive black holes by the Event Horizon Telescope has relied on exhaustive parameter-space searches, matching observations to large, precomputed libraries of theoretical models. As observational data become increasingly precise, the limitations of this computationally expensive approach grow more acute, creating a pressing need for more efficient methods. In this work, we present Jipole, an automatically differentiable (AD), ipole-based code for radiative transfer in curved spacetimes, designed to compute image gradients with respect to underlying model parameters. These gradients quantify how parameter changes—such as the black hole’s spin or the observer’s inclination—affect the image, enabling more efficient parameter estimation and reducing the number of required images. We validate Jipole against ipole in two analytical tests and then compare pixelwise intensity derivatives from AD with those from finite-difference methods. We then demonstrate the utility of these gradients by performing parameter recovery for an analytical model in three increasingly complex cases for the injected image: ideal, blurred, and blurred with added noise. In most cases, high-accuracy fits are obtained in only a few optimization steps, failing only in cases with extremely low signal-to-noise ratios. These results highlight the potential of AD-based methods to accelerate robust, high-fidelity model-data comparisons in current and future black hole imaging efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

First Intrinsic Anisotropy Observations With the Cosmic Background Imager

We present the first results of observations of the intrinsic anisotropy of the cosmic microwave background radiation with the Cosmic Background Imager from a site at 5080 in altitude in northern Chile. Our observations show a sharp decrease in C_l in the range l = 400 - 1500. Such a decrease in power at high l is one of the fundamental predictions of the standard cosmological model, and these are the first observations which cover a broad enough 1-range to show this decrease in a single experiment. The power, C_l, at l approximately 600 is higher than measured by Boomerang and Maxima, with the differences being significant at the 2.7sigma and 1.9sigma levels, respectively. The C_l we have measured enable us to place limits on the density parameter, Omega(tot) <= 0.4 or Omega(tot) >= 0.7 (90% confidence).

Padin, S.↗

Accurate estimation of object location in an image sequence using helicopter flight data

In autonomous navigation, it is essential to obtain a three-dimensional (3D) description of the static environment in which the vehicle is traveling. For a rotorcraft conducting low-latitude flight, this description is particularly useful for obstacle detection and avoidance. In this paper, we address the problem of 3D position estimation for static objects from a monocular sequence of images captured from a low-latitude flying helicopter. Since the environment is static, it is well known that the optical flow in the image will produce a radiating pattern from the focus of expansion. We propose a motion analysis system which utilizes the epipolar constraint to accurately estimate 3D positions of scene objects in a real world image sequence taken from a low-altitude flying helicopter. Results show that this approach gives good estimates of object positions near the rotorcraft's intended flight-path.

Tang, Yuan-Liang↗

JMISR INteractive eXplorer

MISR (Multi-angle Imaging SpectroRadiometer) INteractive eXplorer (MINX) is an interactive visualization program that allows a user to digitize smoke, dust, or volcanic plumes in MISR multiangle images, and automatically retrieve height and wind profiles associated with those plumes. This innovation can perform 9-camera animations of MISR level-1 radiance images to study the 3D relationships of clouds and plumes. MINX also enables archiving MISR aerosol properties and Moderate Resolution Imaging Spectroradiometer (MODIS) fire radiative power along with the heights and winds. It can correct geometric misregistration between cameras by correlating off-nadir camera scenes with corresponding nadir scenes and then warping the images to minimize the misregistration offsets. Plots of BRF (bidirectional reflectance factor) vs. camera angle for points clicked in an image can be displayed. Users get rapid access to map views of MISR path and orbit locations and overflight dates, and past or future orbits can be identified that pass over a specified location at a specified time. Single-camera, level-1 radiance data at 1,100- or 275- meter resolution can be quickly displayed in color using a browse option. This software determines the heights and motion vectors of features above the terrain with greater precision and coverage than previous methods, based on an algorithm that takes wind direction into consideration. Human interpreters can precisely identify plumes and their extent, and wind direction. Overposting of MODIS thermal anomaly data aids in the identification of smoke plumes. The software has been used to preserve graphical and textural versions of the digitized data in a Web-based database.

Nelson, David L.↗

Imagery and UV Spectroscopy of the LMC Supernova Remnant N103B Using HST

We present Hubble Space Telescope(HST)/Wide Field Camera 3 multiband imagery of N103B, which is the remnant of a SN Ia in the Large Magellanic Cloud, as well as HST/Cosmic Origins Spectrograph(COS)ultraviolet spectroscopy of the brightest radiatively shocked region. The images show a wide range of morphology and relative emission-line intensities, from smooth Balmer-line dominated collisionless shocks that are due to the primary blast wave to clumpy radiative shock filaments that are due to secondary shocks in density enhancements. The COS data show strong FUV line emissions, despite a moderately high extinction along this line of sight. We use the COS data with previous optical spectra to constrain the shock conditions, we refine the abundance analysis, and we find abundances that are typical of the local interstellar medium within the uncertainties. Under an assumption that the material being shocked was shed from the pre-supernova system, this finding places constraints on any significant enrichment in that material, and thus on the non-degenerate star in what was presumably a single-degenerate SN Ia.

William P. Blair↗

Radiation transport modeling and assessment to better predict radiation exposure, dose, and toxicological effects to human organs on long duration space flights

NASA is very interested in improving its ability to monitor and forecast the radiation levels that pose a health risk to space-walking astronauts as they construct the International Space Station and astronauts that will participate in long-term and deep-space missions. Human exploratory missions to the moon and Mars within the next quarter century, will expose crews to transient radiation from solar particle events which include high-energy galactic cosmic rays and high-energy protons. Because the radiation levels in space are high and solar activity is presently unpredictable, adequate shielding is needed to minimize the deleterious health effects of exposure to radiation. Today, numerous models have been developed and used to predict radiation exposure. Such a model is the Space Environment Information Systems (SPENVIS) modeling program, developed by the Belgian Institute for Space Aeronautics. SPENVIS, which has been assessed to be an excellent tool in characterizing the radiation environment for microelectronics and investigating orbital debris, is being evaluated for its usefulness with determining the dose and dose-equivalent for human exposure. Thus far. the calculations for dose-depth relations under varying shielding conditions have been in agreement with calculations done using HZETRN and PDOSE, which are well-known and widely used models for characterizing the environments for human exploratory missions. There is disagreement when assessing the impact of secondary radiation particles since SPENVIS does a crude estimation of the secondary radiation particles when calculating LET versus Flux. SPENVIS was used to model dose-depth relations for the blood-forming organs. Radiation sickness and cancer are life-threatening consequences resulting from radiation exposure. In space. exposure to radiation generally includes all of the critical organs. Biological and toxicological impacts have been included for discussion along with alternative risk mitigation methods--shielding and anti-carcinogens. c 2001. Elsevier Science Ltd. All rights reserved.

STS-91 Shuttle Project↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗