Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Impacts of Ionizing Radiation on Sulfur Chloride Compounds for Advanced Fuel Cladding Decontamination Processes

Tripling the nation’s nuclear energy capacity is a critical component for significantly increasing energy production and reducing energy costs for American families and businesses. Achieving this vision requires fuel cycle technologies that maximize resource utilization while minimizing radioactive waste generation. Advanced sulfur chloride–based chlorination technologies are being developed to enable efficient recycling of fuel cladding materials, which account for a significant fraction of used nuclear fuel. However, the impacts of ionizing radiation on the longevity and performance of these sulfur chloride compounds are not well established. Here, we will explore the effects of gamma and electron-beam irradiation on the chemical composition of select sulfur chloride reagents, specifically sulfur monochloride (S2Cl2) and thionyl chloride (SOCl2), and the impacts of pre-irradiation on the chlorination yield/chemical dissolution of surrogate aluminum alloy 6061 (AA6061-T6) materials.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Validation of the SCEPTRE Boltzmann-CSD Solver

A new Boltzmann-CSD solver has been developed within the SCEPTRE radiation-transport code, based on the 1st-order form of the transport equation, using discontinuous finite elements in space and energy and discrete ordinates in angle. The Boltzmann-CSD solver has been validated against experimental data for electron energy deposition distributions and for electron emission spectra. Comparison of the calculated results with experimental data shows excellent agreement for many of the test configurations and reasonable agreement for other test configurations. The tests have also been modeled with the ITS Monte Carlo code, which also shows excellent to reasonable agreement with the SCEPTRE results and experimental data. The SCEPTRE Boltzmann-CSD solver relies on electron cross sections generated by the legacy CEPXS code, which currently is limited to electron-only Boltzmann-CSD cross sections. Performing full electron-photon radiation transport with the Boltzmann-CSD solver will require further development in the cross section generating code. For the energy- deposition calculations, neglecting photon transport results in at most about 5% overprediction of the energy deposition for high-energy electrons on high-Z targets, and relatively insignificant difference for the other test configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Module Testing Procedures and Results for the CMS Phase-2 Outer Tracker Upgrade at Fermilab

The High-Luminosity LHC (HL-LHC) will operate at significantly increased luminosities and is expected to deliver about 3000 $fb^{-1}$ of proton-proton collision data at $\sqrt{s}=14$ TeV over a decade of operation. To maintain efficient tracking and triggering performance under high pileup and radiation conditions, the CMS experiment is upgrading its tracking detector for Phase-2 operations. The upgraded Outer Tracker (OT) will consist of Pixel-Strip (PS) and Strip-Strip (2S) silicon modules capable of providing tracking information to the Level-1 trigger at 40 MHz. Production and qualification of OT modules have been ongoing for about one year across several assembly and testing centers in the US, Europe, India, and Pakistan, requiring extensive testing to ensure stable operation in the HL-LHC environment. Fermilab is responsible for the production and testing of a significant fraction of the OT modules. The testing activities include IV characterization of silicon sensors, noise and pedestal measurements, verification of communication between module components, and burn-in studies using cold-box systems operated under controlled thermal conditions. Results from module testing and qualification studies performed during production will be presented.

Baradia, Sweta [UC, Davis (main)]↗

3D modeling of the Staged Z-pinch with the FLASH code

The Staged Z-pinch (SZP) fusion concept is a magneto-inertial compression scheme developed by Magneto-Inertial Fusion Technologies, Inc. (MIFTI), in which small amounts of fusion fuel are brought to fusion-relevant conditions by passing multi-million amperes strong current through a cylindrical shell of high atomic number material. One- and two-dimensional modeling performed by MIFTI with the MACH2 code, suggests that net fusion energy gain can be achieved when currents in the 10 million amperes range compress a 50%-50% mixture of deuterium and tritium gas. In this project we enhance and use the FLASH code to execute high-fidelity, simulations of various SZP configurations, a collaboration between the Flash Center for Computational Science at the University of Rochester and the Laboratory for Laser Energetics, and MIFTI. FLASH is a high-performance computing, multi-physics, radiation magnetohydrodynamic (MHD) code with extended physics capabilities, which is developed at the Flash Center. The goal of this project is to assess the shell/fuel stability of the pinch to two- and three-dimensional MHD instabilities and to utilize FLASH’s extended physics capabilities to understand how extended-MHD effects impact implosion dynamics and plasma conditions at stagnation. The project is a natural extension of an ongoing collaborative effort between MIFTI and the Flash Center through the U.S. DOE Advanced Research Projects Agency-Energy (ARPA-E) BETHE program and can provide MIFTI with simulation capabilities that are currently beyond their reach with MACH2. Ultimately, MIFTI wants FLASH to become one of their simulation workhorses for reliable, high-fidelity SZP platform design. During the project, the Flash Center team developed a suite of in one- and two-dimensional FLASH simulations to model different variants of the SZP platform, performed code-to-code comparisons with MACH2, and used the FLASH code to design and model SZP experiments like the Double Eagle experiments that MIFTI recently performed. Also, the Flash Center team developed the capabilities of FLASH to be able to do three-dimensional simulations of pulsed-power experiments with the code for the first time. Two publications from this effort are currently under review and two more are in preparation. MIFTI has also committed to the use of FLASH for future SZP simulation efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subtropical Eastern North Pacific SST bias in earth system models

Karthik Balaguru (PNNL), Luke Van Roekel (LLNL), L. Ruby Leung (PNNL) and Milena Veneziani (LLNL) Abstract: This study systematically evaluates the warm SST bias in the Subtropical Eastern North Pacific (SENP), a problem plaguing most CMIP6 models, using the Energy Exascale Earth System Model version 1 (E3SM). Compared to the model at its standard resolution (1o atmosphere, 30-60 km ocean), the SST bias improves in several regions at high resolution (0.25o atmosphere, 18-6 km ocean) except in subtropical eastern boundary regions, such as the SENP. A mixed layer heat budget analysis reveals that errors in the surface radiative fluxes and horizontal heat advection are primarily responsible for the bias. Analysis of HighResMIP models indicates that the lack of improvement in the SENP SST bias with resolution is not native to E3SM alone. A larger CMIP6 inter-model correlation of SST bias with biases in surface winds than radiation highlights the important role of large-scale circulation biases in the SENP SST bias in coupled models.

Balaguru, Karthik↗

Assessment of CMIP5 and CMIP6 AMIP Simulated Clouds and Surface Shortwave Radiation Using ARM Observations over Different Climate Regions

The simulations of clouds and surface radiation from 10 CMIP6 models and their CMIP5 predecessors are compared to the ARM ground-based observations over different climate regions. Compared to the ARM radar-lidar derived total cloud fractions (CFT) and cloud fraction vertical distributions over the six selected sites, both CMIP5 and CMIP6 significantly underestimated CFT and low-level CF over the Northern Hemispheric midlatitude sites (SGPC1 and ENAC1), although the biases are generally smaller in CMIP6. Over the tropical oceanic site (TWPC2), 5 out of 10 CMIP6 models better simulated low-level CF than their CMIP5 predecessors. CMIP6 simulations generally agreed well with the ARM observations in CFT and cloud fraction vertical distributions over the tropical continental (MAOM1) and coastal (TWPC3) sites but missed the transitions between dry and wet seasons, similar to CMIP5 simulations. The improvements in downwelling shortwave fluxes (SWdn) at the surface from the majority of CMIP6 compared to CMIP5 primarily resulted from the improved cloud fraction simulations, especially over the SGPC1, ENAC1, and TWPC3 sites. By contrast, both CMIP5 and CMIP6 models exhibited diverse performances of clouds and shortwave radiation over the Arctic site (NSAC1), where CMIP6 models produced more clouds than CMIP5 models, especially for the low-level clouds. The comparisons between observations and CMIP5 and CMIP6 simulations provide valuable quantitative assessments of the accuracy of mean states and variabilities in the model simulations and shed light on general directions to improve climate models in different regions.

54 ENVIRONMENTAL SCIENCES↗

Decoupling excitons from high-frequency vibrations in organic molecules

The coupling of excitons in π-conjugated molecules to high-frequency vibrational modes, particularly carbon–carbon stretch modes (1,000–1,600 cm -1 ) has been thought to be unavoidable. These high-frequency modes accelerate non-radiative losses and limit the performance of light-emitting diodes, fluorescent biomarkers and photovoltaic devices. Here, by combining broadband impulsive vibrational spectroscopy, first-principles modelling and synthetic chemistry, we explore exciton–vibration coupling in a range of π-conjugated molecules. We uncover two design rules that decouple excitons from high-frequency vibrations. First, when the exciton wavefunction has a substantial charge-transfer character with spatially disjoint electron and hole densities, we find that high-frequency modes can be localized to either the donor or acceptor moiety, so that they do not significantly perturb the exciton energy or its spatial distribution. Second, it is possible to select materials such that the participating molecular orbitals have a symmetry-imposed non-bonding character and are, thus, decoupled from the high-frequency vibrational modes that modulate the π-bond order. We exemplify both these design rules by creating a series of spin radical systems that have very efficient near-infrared emission (680–800 nm) from charge-transfer excitons. We show that these systems have substantial coupling to vibrational modes only below 250 cm -1 , frequencies that are too low to allow fast non-radiative decay. This enables non-radiative decay rates to be suppressed by nearly two orders of magnitude in comparison to π-conjugated molecules with similar bandgaps. Our results show that losses due to coupling to high-frequency modes need not be a fundamental property of these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the Geometry of the Near-core Magnetic Field in Massive Stars

It is well-known that the cores of massive stars sustain a stellar dynamo with a complex magnetic field configuration. However, the same cannot be said for the field's strength and geometry at the convective–radiative boundary, which are crucial when performing asteroseismic inference. In this Letter, we present 3D magnetohydrodynamic (MHD) simulations of a 7 M ⊙ mid-main-sequence star, with particular attention given to the convective–radiative boundary in the near-core region. Our simulations reveal that the toroidal magnetic field is significantly stronger than the poloidal field in this region, contrary to recent assumptions. Moreover, the rotational shear layer, also important for asteroseismic inference, is specifically confined within the extent of the Brunt–Väisälä frequency peak. These results, which are based on the inferred properties of HD 43317, have widespread implications for asteroseismic studies of rotation, mixing, and magnetism in stars. While we expect our results to be broadly applicable across stars with similar Brunt–Väisälä frequency profiles and stellar masses, we also expect the MHD parameters (e.g., Re m ) and the initial stellar rotation rate to impact the geometry of the field and differential rotation at the convective–radiative interface.

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for the radiative transition χ c 1 ( 3872 ) → γ ψ 2 ( 3823 )

Using 9.0 f b − 1 of e + e − collision data collected at center-of-mass energies from 4.178 to 4.278 GeV with the BESIII detector at the BEPCII collider, we perform the first search for the radiative transition χ c 1 ( 3872 ) → γ ψ 2 ( 3823 ) . No signal is observed and the upper limit on the ratio of branching fractions B ( χ c 1 ( 3872 ) → γ ψ 2 ( 3823 ) , ψ 2 ( 3823 ) → γ χ c 1 ) / B ( χ c 1 ( 3872 ) → π + π − J / ψ ) is set at 0.075 at the 90% confidence level. Our result contradicts theoretical predictions under the assumption that the χ c 1 ( 3872 ) is the pure charmonium state χ c 1 ( 2 P ) . Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Development of an Enhanced Radiation Physics Toolset for Modeling Spectral and Imaging Signatures in the Warm Dense Matter Experiments

Radiative and atomic processes in plasmas play a critical role in a wide variety of high energy density laboratory plasma (HEDLP) experiments. The emission, absorption, and transport of radiation can strongly affect the overall energetics and evolution of such plasmas. In addition, radiation-based diagnostics – including imaging, spectroscopy, and absolute flux measurements – are widely used to determine key features of HEDLPs. To advance our understanding of HEDLP science, it is vital to have high-fidelity computational physics tools that have well-tested radiation physics modeling, and that are readily accessible to researchers in the HEDLP community. Simulations play an extremely important role for planning and designing the experiments, as well as for post-experiment data analysis. Prism Computational Sciences develops software that is used by National Laboratories and universities (including five members of LaserNetUS network). Prominent examples of such research efforts include z-pinch and short-pulse laser experiments designed to study the basic physics of photoionized plasmas and photoionization fronts, as well as their application to astrophysical plasmas. The main effort was dedicated to the development of non-equilibrium equation-of-state (EOS) models within the HELIOS-CR code, a hydrodynamics code with inline collisional-radiative atomic kinetics. Gas cell experiments on Z and Omega demonstrated the importance of non-equilibrium effects on atomic kinetics in photoionized plasmas. Recent proof-of-principle experiments on Omega EP confirmed the advantages of using a short-pulse laser to create an intense radiation drive, leading to additional experiments being proposed. Photoionization front experiments at LLE also emphasizes the importance of radiation and atomic physics. In both studies, HELIOS-CR simulations played a crucial role in computing non-equilibrium opacities and ionization distributions. A newly developed non-LTE EOS model will help addressing possible non-equilibrium effects, on for example specific heat, and their influence in plasma evolution. Prism also implemented support for open-source atomic data generated by the Flexible Atomic Code. This allows researchers to generate custom atomic tables and use them within the complex framework of simulation tools developed by Prism. The ability to use open-source atomic data would be extremely valuable for hydrodynamics and spectroscopic simulations that include high-Z materials, e.g., picosecond x-ray pulse generation experiments. Support for new atomic structures was fully implemented, and the data can be used by all simulation tools developed at Prism: radiation-hydrodynamics, imaging and spectroscopy, EOS and opacity. The development resulted in a significant fidelity enhancement to the simulations tools developed by Prism that are currently used in other cutting-edge experiments including: opacity measurement experiments performed to both understand the basic radiative and atomic properties of plasmas as well as provide data for more accurately modeling the internal structure of the Sun and other stars, high-intensity short-pulse laser experiments performed to develop short-wavelength light sources for use as backlighters and to investigate fast ignition concepts for inertial fusion energy; capsule implosion experiments designed to develop inertial fusion as an energy source, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗