Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

An aircraft radiometer front end, addendum

A detailed description is given of a completely quasi-optical aircraft radiometer for use at frequencies of 150 GHz and above. The radiometer calibration and beam switching is described as well as a reflection isolator utilizing a reciprocating mirror and a quasi-optical local oscillator injection system. Receiver applications and performance levels are also given.

Gustincic, J. J.↗

Remote sensing of earth resources using a spaceborne microwave radiometer

A microwave radiometer was one of five experiments installed onboard the NASA Skylab spacecraft in order to remotely monitor selective earth resources information. The essential features of the radiometer are described, and typical data required in space is also presented in order to illustrate the instrument's utility.

Leber, A.↗

System considerations for an earth radiation budget scanning radiometer

The objective of the scanning radiometer of the Earth Radiation Budget Satellite System is to measure the longwave and reflected shortwave radiation from the earth on a gridwork of approximately 250 km square regions in order to obtain one-month averages of flux with global coverage to an accuracy of 14 W/sq m. A number of considerations in the choice of some of the design parameters of the scanner are discussed. The error sources which must be considered in the design of a scanning radiometer designed to measure regional radiation budget are examined. An analysis of the system performance through spatial averaging is presented. The analysis provides insight into the effects of field of view, time response, onboard processing and spatial averaging.

Smith, G. L.↗

Detected noise levels guide radiometer design

A survey of component demands and design techniques for radiometers is presented. The design of a typical radiometer is traced from the antenna through the video and data-collection stages. Key design equations are given. An example is considered that shows how IF amplifier gain must be chosen to mask video noise. The influence of front-end losses on back-end design is studied.

Schuchardt, J. M.↗

Radiometer at a frequency of 108-120 GHz for study of the earth's atmosphere

Calculated and experimental design and operating characteristics of a 108-120 GHz superheterodyne radiometer with intermediate frequency modulation and a second harmonic frequency converter are presented and discussed. With a 1 sec time constant, the radiometer fluctuation sensitivity threshold is 1 K, without degradation in 2 hours of operation. Graphs of frequency variations, calibration, conversion loss, rectified current, fixed bias voltage, and contact needle impedance are included.

Bordonskiy, G. S.↗

Use of computers to exclude the influence of radiometer instability upon measurement results

A radiometer, practically insensitive to great fluctuations in the equipment amplification coefficient, was developed by dividing the useful signal by a reference signal and modulating the two signals at different frequencies. The signals are simultaneously separated by corresponding synchronous detectors and recorded over two channels. The operation is simplified by replacing the continuous signals by a sampling of discrete values, and using a digital computer. The four steps involved in the process are described and a block diagram is included. This technique not only directly connects the radiometer with the computer, but also records all data provided by the control and signal channels.

Domnin, S. L.↗

Analyses of earth radiation budget data from unrestricted broadband radiometers on the ESSA 7 satellite

Six months of data from the wide-field-of-view low resolution infrared radiometers on the Environmental Science Services Administration (ESSA) 7 satellite were analyzed. Earth emitted and earth reflected irradiances were computed at satellite altitude using data from a new in-flight calibration technique. Flux densitites and albedos were computed for the top of the earth's atmosphere. Monthly averages of these quantities over 100 latitude zones, each hemisphere, and the globe are presented for each month analyzed, and global distributions are presented for typical months. Emitted flux densities are generally lower and albedos higher than those of previous studies. This may be due, in part, to the fact that the ESSA 7 satellite was in a 3 p.m. Sun-synchronous orbit and some of the comparison data were obtained from satellites in 12 noon sun-synchronous orbits. The ESSA 7 detectors seem to smooth out spatial flux density variations more than scanning radiometers or wide-field-of-view fixed-plate detectors. Significant longitudinal and latitudinal variations of emitted flux density and albedo were identified in the tropics in a zone extending about + or - 25 deg in latitude.

Weaver, W. L.↗

Experimental evaluation of a unique radiometer for use in solar simulation testing

The vane radiometer is designed to operate over the range 0-1 solar constant and is capable of withstanding temperatures over the range -200 to +175 C. Two of these radiometers, for use in the Johnson Space Center's largest space simulator, have been evaluated for: (1) thermal sensitivity with no solar input, (2) linearity as a function of solar simulation input, and (3) output drift as a function of time. The minimum sensitivity was measured to be approximately 25.5 mV/solar constant. An unusual effect in the pressure range 760 to 1.0 torr is discussed.

Richmond, R. G.↗

Development of multipurpose radiometer

A radiometer has been developed for thermal vacuum testing at the Johnson Space Center. The radiometer: (1) measures incident or absorbed irradiance in the solar and/or infrared spectral regions, (2) measures emittance and absorptance, (3) has improved sensitivity, (4) is light in weight, (5) is rugged and very reliable, (6) is temperature-compensated, (7) requires no external control, circuitry or in situ calibration, and (8) has reduced operating costs.

Redman, R. S.↗

Pioneer-Venus large probe infrared radiometer /LIR/ optical system

The LIR (large probe infrared radiometer) instrument has been developed for the NASA Ames Research Center for use in the 1978 Venus Atmospheric Probe Mission. The mission objectives are to determine the nature and composition of the clouds, the composition and structure of the atmosphere, and the atmospheric circulation pattern of the planet Venus. The LIR is a six-channel (3-50 micron) internally calibrated radiometer which measures the radiance difference at plus or minus 45 deg to the horizontal as viewed through a single diamond window in the spacecraft. The LIR optical system consists of a unique arrangement of hollow light pipes which optically couple a six element detector/filter array to the spacecraft window while mechanically and thermally isolating the array from the window's harsh thermal environment. A single rotating section with a 45 deg bend and containing a collimator alternately views up and down through director/extender pipes located adjacent to the diamond window. Light is transferred from the rotating section to a fixed section containing a diamond diffuser to scramble the light. This minimizes asymmetries and improves channel field of view overlap.

Brown, F. G.↗

A cloud physics radiometer

The paper describes the design features and capabilities of a seven-channel cloud physics radiometer (CPR) for remote sensing of cloud properties. The CPR channel characteristics and functions are tabulated and diagrammed. Each of the first three channels utilizes a photo-multipler detector, with the high-voltage power supply integrated with the tube into a single unit. In operation a heater is used to keep the optics temperature at or above 273 K and this temperature is constantly monitored. The last four channel detectors and filters are all cooled to the temperature of liquid nitrogen. The inclined scanning mirror rotates at a rate of 3.48 rps. Registration pulses are triggered and recorded as the mirror enters and leaves the + or -45 deg earth observation region. The ice-cloud, water cloud, snow discriminator detector has worked quite well in general. Interesting radiometer data have been obtained and their analysis is under way. The combination of the CPR and the Cloud Lidar System will make possible sophisticated remote sensing cloud studies.

Kyle, H. L.↗

Improvement of scanning radiometer performance by digital reference averaging

Most radiometers utilize a calibration technique in which measurements of a known reference are subtracted from measurements of an unknown source so that common-mode bias errors are cancelled. When a radiometer is scanned over a varying scene, it produces a sequence of outputs, each being proportional to the difference between the reference and the corresponding input. A reference averaging technique is presented that employs a simple digital algorithm which exploits the asymmetry between the time-variable scene inputs and the nominally constant reference input by averaging many reference measurements to decrease the statistical uncertainty in the reference value. This algorithm is, therefore, optimized by an asymmetric chopping sequence in which the scene is viewed for more than one-half of the duty cycle (unlike the analog Dicke technique). Reference averaging algorithms are well within the capabilities of small microprocessors. Although this paper develops the technique for microwave radiometry, it may be beneficial for any system which measures a large number of unknowns relative to a known reference in the presence of slowly varying common-mode errors.

Bremer, J. C.↗

Optimum frequencies of passive microwave radiometer for tropospheric path-length correction

Radio-astronomical observations require accurate calibration of tropospheric path length. Such calibration can be achieved by microwave radiometers operating near the 22-GHz water vapor line. However, the performances of current passive microwave radiometers are meteorology-profile dependent. This is due mainly to incorrect frequency combinations and to saturation of brightness temperatures. By properly selecting an optimum frequency pair and removing the saturation effect, the dependency is alleviated and can be further adjusted by surface measurements alone. Hence, a universal calibration equation is applicable to all environmental conditions. Optimum frequency pairs are systematically searched. Simulation analysis indicates that calibration for the tropospheric water-vapor path-length error is better than 0.3 cm at zenith and better than 2 cm for an elevation angle as low as 10 deg.

Wu, S.-C.↗

Seasat visible and infrared radiometer

The visual and infrared radiometer (VIRR) system on Seasat is described, and methods used in the geophysical evaluation of digital data from this system are discussed. The main function of the radiometer system is to provide images of visual reflection and thermal infrared emission from ocean, coastal and atmospheric features to facilitate interpretation of data from other Seasat sensors; in addition, it is expected to provide some derived quantitative measurements of such factors as sea-surface temperature and cloud-top height. Some results of a statistical comparison of Seasat VIRR-derived sea-surface temperatures in a cloud-free region with a National Oceanic and Atmospheric Administration (NOAA) analysis based on surface measurements made in the same region are presented. The data sets were in agreement of plus or minus 1.7 deg K root-mean-square. The means of the two sets of temperatures were 293.9 deg K (VIRR) and 293.1 deg K (NOAA), and the standard deviations were 3.21 deg and 3.2 deg K, respectively.

Mcclain, E. P.↗

A Microwave Radiometer Spacecraft, some control requirements and concepts

A general overview of a conceptual design for a Microwave Radiometer Spacecraft using a large passive reflector, microwave radiometers, and advanced control concepts is presented. The mission requirements, developed around high resolution, large area mapping of soil moisture for global crop forecasting, are reviewed. These mission requirements, along with system design requirements, dictate the need for a reflector in excess of 700 meters in diameter. Conceptual designs for supporting structures and subsystems, including attitude and surface control, are summarized.

Lovelace, U. M.↗

Field limiter for solar radiometers

Lenses project solar image onto aperature to exclude circumsolar radiation, more precisely measuring energy captured by receiver aperatures of highly-concentrating solar thermal-energy converters. First version uses achromatic objective lens to form image of Sun at aperature ahead of radiometer cavity. Smaller second version with shorter focal length forms image magnified by another lens and thrown onto aperature. Both Versions require calibration against standard radiometer.

Berdahl, C. M.↗

Mechanisms of UK radiometers flown on Nimbus 5 and 6 with particular reference to bearings, pivots and lubrication

The mechanisms incorporated in the vertical sounding infrared radiometry experiments which were launched on Nimbus 5 in 1972 and on Nimbus 6 in 1975 are discussed. Both use dry lubricants. The Nimbus 5 radiometer includes a rotating chopper driven via a carbon fiber-acetal resin gearwheel. The driving motor runs at 2000 rpm and has completed over 7 x 10 to the 9th power revolutions. Four gear driven filter wheels powered by stepper motors have each completed 2 x 10 to the 8th power changes. The input calibration mirror mechanism and its field of view compensation mechanisms are also described. All 25 ball races used in the experiment are of the film transfer type. The Nimbus 6 radiometer includes two cells. Each contains a piston supported on diaphragm springs and driven electromagnetically. The pistons are 6 cm in diameter with a stroke of 1 cm and are driven at their mechanical resonant frequency of approx. 15 Hz. The calibrating mirrors rotate periodically to view a target. The support pivots are synthetic sapphire ring stones with separate end thrust stones. The problems of mounting these stones to withstand vibration loads is described.

Hadley, H.↗