Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raster”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Direct-write liquid phase transformations with a scanning transmission electron microscope

The highly energetic electron beam from a scanning transmission electron microscope (STEM) can induce local changes in the state of matter, ranging from local knock-out and atomic movement, to amorphization/crystallization, and chemical/electrochemical reactions occuring at localized liquid-solid and gas-solid interfaces. To date, fundamental studies of e-beam induced phenomena and practical applications have been limited by conventional e-beam rastering modes that allow only for uniform e-beam exposures. Here we develop an automated liquid phase nanolithography method that is capable of directly writing nanometer scaled features within silicon nitride encapsulated liquid cells. An external beam control system, connected to the scan coils of an aberration-corrected STEM, is used to precisely control the position, dwell time, and scan velocity of a sub-nanometer STEM probe. Site-specific locations in a sealed liquid cell containing an aqueous solution of H 2 PdCl 4 are irradiated to controllably deposit palladium onto silicon nitride membranes. We determine the threshold electron dose required for the radiolytic deposition of metallic palladium, explore the influence of electron dose on the feature size and morphology of nanolithographically patterned nanostructures, and propose a feedback-controlled monitoring method for active control of the nanofabricated structures through STEM detector signal monitoring. As a result, this approach enables both fundamental studies of electron beam induced interactions with matter, as well as opens a pathway to fabricate nanostructures with tailored architectures and chemistries via shape-controlled nanolithographic patterning from liquid phase precursors.

43 PARTICLE ACCELERATORS↗

Spatial dynamics of lithiation and lithium plating during high-rate operation of graphite electrodes

The principal inhibitor of fast charging lithium ion cells is the graphite negative electrode, where favorable conditions for lithium plating occur at high charge rates, causing accelerated degradation and safety concerns. The local response of graphite, both at the electrode and particle level, when exposed to fast charging conditions of around 6C is not well understood. Consequently, the conditions that lead to the onset of lithium plating, as well as the local dynamics of lithium plating and stripping, have also remained elusive. Here, we use high-speed (100 Hz) pencil-beam X-ray diffraction to repeatedly raster along the depth of a 101 μm thick graphite electrode in 3 μm steps during fast (up to 6C) charge and discharge conditions. Consecutive depth profiles from separator to current collector were each captured in 0.5 seconds, giving an unprecedented spatial and temporal description of the state of the electrode and graphite's staging dynamics during high rate conditions. The electrode is preferentially activated near the separator, and the non-uniformity increases with rate and is influenced by free-energy barriers between graphite's lithiation stages. The onset of lithium plating and stripping was quantified, occurring only within the first 15 μm from the separator. The presence of lithium plating changed the behavior of the underlying graphite, such as causing co-existence of LiC 6 and graphite in the fully discharged state. Finally, the staging behavior of graphite at different rates was quantified, revealing a high dependency on rate and drastic hysteresis between lithiation and delithiation.

25 ENERGY STORAGE↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a MeV proton beam irradiation system

A proton beam irradiation system for the application of the MeV class proton beam, such as an implantation for a power semiconductor device and a smart-cut technology for a semiconductor production process, has been developed. This system consists of a negative ion source, an Einzel lens for a low energy beam transport, accelerating tubes, a gas stripper, a Cockroft-Walton high voltage power supply with 1 MV, a vacuum pumping system, and a high pressure insulating gas system. The negative hydrogen ion source is based on TRIUMF's design. Following the tandem accelerator, a pair of magnets is installed for raster scanning of the MeV proton beam to obtain a uniform irradiation pattern on the target. The system is 7 m long from the ion source to the target and is optimized for the proton beam irradiation. The details of the system development will be described.

43 PARTICLE ACCELERATORS↗

Unveiling the Secrets of Archimedes

Progress has been made at the Stanford Linear Accelerator Center (SLAC) toward deciphering the remaining 10-20% of ancient Greek text contained in the Archimedes palimpsest. The text is known to contain valuable works by the mathematician, including the Method of Mechanical Theorems, the Equilibrium of Planes, On Floating Bodies, and several diagrams. The only surviving copy of the text was recycled into a prayer book in the Middle Ages. The ink used to write on the goat skin parchment is partly composed of iron, which is visible by x-ray radiation. To image the palimpsest pages, the parchment was framed and placed in a stage that moved according to the raster method. When an x-ray beam was incident upon the parchment the iron in the ink was detected by a germanium detector. The resultant signal was converted to a gray-scale image. It was extremely important that each line of data was well aligned with the line that came before it. The objectives of this experiment were to determine the best parameters for producing well-aligned images and to reduce the scanning time. Imaging half a page of parchment during previous beam time for this project was achieved in thirty hours. Equations were produced to evaluate count time, shutter time, and the number of pixels in this experiment. On Beamline 6-2 at the Stanford Synchrotron Radiation Laboratory (SSRL), actual scanning time was reduced by one fourth. The remaining pages were successfully imaged and sent to ancient Greek experts for translation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals

A novel combined imaging system for small animals using dilute concentrations of iodine as a contrast agent was developed for wide and pencil photon beam image acquisitions. This combined imaging system used K-edge subtraction (KES) and fluorescence subtraction imaging (FSI) and was tested at the Hard x-ray Microanalysis beamline at the Canadian Light Source. The initial wide beam KES image acquired with a charge-coupled device camera was used to identify regions of interest for further investigation and determine the location and area of the raster scan for pencil beam imaging. The pencil photon beam scanning mode acquired simultaneously KES and FSI measurements with an ionization chamber measuring the KES data and a multielement germanium detector measuring the FSI data. A description of the system is given as well as preliminary results using an iodine test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microbeam Beam Heating Analysis of Thin Foils Using Heat Conduction Theory

The temperature distribution in and near the scan region of an ion microbeam is estimated using heat conduction theory. In the calculation, the energy deposited by a beam spot on a thin foil is treated as a point energy source. The spatial and time dependent temperature contributions from energy deposited by the ion beam rastering in a square scan pattern were then computed. The results showed that for poor conductors, the temperature of the material under the scan region can rise rapidly by up to two orders of magnitude, while that of good conductors remains virtually unchanged. The calculated results were consistent with experimental data where Mylar foils were scanned using an He microbeam and the time for melt through was measured. Radiational cooling effects were also investigated and found to contribute little to the heat losses at typical microbeam beam powers.

36 MATERIALS SCIENCE↗

The Heidelberg Ion Therapy (HIT) Accelerator Coming into Operation

The Heidelberg Ion Therapy Facility (HIT) is the first dedicated proton and carbon therapy facility in Europe. It uses full three dimensional intensity controlled raster scanning as basic treatment technique. Commissioning of the accelerator with beam was successfully finished for three fixed beam places in April 2008. A library of 60000 combinations of beam properties (ion type, treatment place, energy, intensity, beam size) is now offered to the treatment technique teams preparing the treatment systems for the clinical use. The HIT facility also comprises a gantry with full scanning properties constituting the first carbon ion gantry worldwide. The gantry can be rotated by 360 deg., so that the beam may be aimed at the patient from arbitrary directions.

43 PARTICLE ACCELERATORS↗

Electron beam irradiation of dimethyl-(acetylacetonate) gold(III) adsorbed onto solid substrates

Electron beam induced deposition of organometallic precursors has emerged as an effective and versatile method for creating two-dimensional and three-dimensional metal-containing nanostructures. However, to improve the properties and optimize the chemical composition of nanostructures deposited in this way, the electron stimulated decomposition of the organometallic precursors must be better understood. To address this issue, we have employed an ultrahigh vacuum-surface science approach to study the electron induced reactions of dimethyl-(acetylacetonate) gold(III) [Au{sup III}(acac)Me{sub 2}] adsorbed onto solid substrates. Using thin molecular films adsorbed onto cooled substrates, surface reactions, reaction kinetics, and gas phase products were studied in the incident energy regime between 40 and 1500 eV using a combination of x-ray photoelectron spectroscopy (XPS), reflection absorption infrared spectroscopy (RAIRS), and mass spectrometry (MS). XPS and RAIRS data indicate that electron irradiation of Au{sup III}(acac)Me{sub 2} is accompanied by the reduction in Au{sup III} to a metallic Au{sup 0} species embedded in a dehydrogenated carbon matrix, while MS reveals the concomitant evolution of methane, ethane, carbon monoxide, and hydrogen. The electron stimulated decomposition of Au{sup III}(acac)Me{sub 2} is first-order with respect to the surface coverage of the organometallic precursor, and exhibits a rate constant that is proportional to the electron flux. At an incident electron energy of 520 eV, the total reaction cross section was {approx_equal}3.6x10{sup -16} cm{sup 2}. As a function of the incident electron energy, the maximum deposition yield was observed at {approx_equal}175 eV. The structure of discrete Au-containing deposits formed at room temperature by rastering an electron beam across a highly ordered pyrolytic graphite substrate in the presence of a constant partial pressure of Au{sup III}(acac)Me{sub 2} was also investigated by atomic force microscopy.

36 MATERIALS SCIENCE↗

Measurement and Compensation of BPM Chamber Motion in HLS

Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20{mu}m without the compensation of BPM chamber motion in the runtime.

43 PARTICLE ACCELERATORS↗

Effect of Te Inclusions in CdZnTe Crystals at Different Temperatures

CdZnTe crystals often exhibit nonuniformities due to the presence of Te inclusions and dislocations. High concentrations of such defects in these crystals generally entail severe charge-trapping, a major problem in ensuring the device's satisfactory performance. In this study, we employed a high-intensity, high-spatial-resolution synchrotron x-ray beam as the ideal tool to generate charges by focusing it over the large Te inclusions, and then observing the carrier's response at room- and at low-temperatures. A high spatial 5-{micro}m resolution raster scan revealed the fine details of the presence of extended defects, like Te inclusions and dislocations in the CdZnTe crystals. A noticeable change was observed in the efficiency of electron charge collection at low temperature (1 C), but it was hardly altered at room-temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of Subwavelength Grating on Molybdenum Mirrors Using a Femtosecond Ti:sapphire Laser System Operating at 10 Hz

We report formation of subwavelength surface grating over large surface area of molybdenum mirror by multiple irradiation of amplified femtosecond laser pulses from a homemade Ti:sapphire oscillator-amplifier laser system in a raster scan configuration. The laser system delivered 2 mJ, 80 fs duration laser pulses at a pulse repetition rate of 10 Hz. Various parameters such as pulse fluence, number of pulses, laser polarization, scan speed, and scan steps were optimized to obtain uniform subwavelength gratings. Energy dispersive x-ray spectroscopy measurements were conducted to analyze the elemental composition of mirror surfaces before and after laser treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual growth modes in ion bombarded Si surfaces

Morphological studies were done on Si (001) surfaces after rastering them with a 1 keV O{sub 2}{sup +} ion beam at an angle. The resulting mounded morphology was studied using atomic force microscopy (AFM) measurements. The roughness at different length scales were further extracted and quantified from AFM measurements using scaling analysis. Results indicate two growth regimes of the evolving surface which were evident from the power spectral density (PSD) and interface width analysis of the eroded surfaces. Initially the growth is unstable followed by a stable regime of the nanostructures evolved after about 35 minutes of erosion. Temporal studies done on these surfaces show the onset of shadowing at higher sputtering times thus indicating the breakdown of the growth model at these times.

36 MATERIALS SCIENCE↗

Photon induced Schottky barrier effects in inverse-extraordinary optoconductance structures

We expand upon our previous work and characterize the photo-dependence of the effective Schottky barrier in EOC and I-EOC heterostructures by measuring the open circuit voltage and the change in the reverse bias resistance. Under full illumination by a 5 mW, 632.8 nm HeNe laser, the barrier is effectively eliminated and the Ti-GaAs interface becomes Ohmic. The reverse bias resistance changes by a factor of 209 over an illumination intensity change of 10–5:1. While this work illustrates the behavior of the Schottky interface upon illumination, it also demonstrates the effectiveness of the four-point, van der Pauw measurement fundamental to EOC/I-EOC phenomena at monitoring changes in the active region of the mesa. The resistance is largely unaffected by the photovoltaic, DC offset of the surrounding leads, as indicated by the radial symmetry of 2-D resistance maps obtained by rastering the laser across EOC/IEOC devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale patterning of graphene through femtosecond laser ablation

We report on nanometer-scale patterning of single layer graphene on SiO{sub 2}/Si substrate through femtosecond laser ablation. The pulse fluence is adjusted around the single-pulse ablation threshold of graphene. It is shown that, even though both SiO{sub 2} and Si have more absorption in the linear regime compared to graphene, the substrate can be kept intact during the process. This is achieved by scanning the sample under laser illumination at speeds yielding a few numbers of overlapping pulses at a certain point, thereby effectively shielding the substrate. By adjusting laser fluence and translation speed, 400 nm wide ablation channels could be achieved over 100 μm length. Raster scanning of the sample yields well-ordered periodic structures, provided that sufficient gap is left between channels. Nanoscale patterning of graphene without substrate damage is verified with Scanning Electron Microscope and Raman studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of a 2.8 THz quantum cascade laser with a semiconductor nanowire field-effect transistor coupled to a bow-tie antenna

The use of a high-electron mobility semiconductor nanowire as transistor channel has recently allowed the extension of the spectral coverage of THz field-effect transistor detectors up to 1.5 THz. In this report, we demonstrate efficient operation of a field-effect transistor detector based on a semiconductor nanowire at a much higher frequency, 2.8 THz, with a responsivity ≈5 V/W in a bandwidth ≈100 kHz, thus proving the full potential of such approach for the detection of THz quantum cascade lasers. Finally, such a THz sensing system is exploited to perform raster scan transmission imaging, with high spatial resolution, signal-to-noise ratio, and acquisition rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Large area deposition of Rh single and Rh/W/Cu multilayer thin films on stainless steel substrate by pulsed laser deposition technique

Mirror like thin films of single layer Rh and multilayer Rh/W/Cu are deposited on highly polished 50 mm diameter stainless steel substrate by Pulsed Laser Deposition (PLD) technique for first mirror application in fusion reactors. For this, the conventional PLD technique has been modified by incorporating substrate rastering stage for large area deposition via PLD. Process optimization to achieve uniformity of deposition as estimated from fringe visibility and thickness is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗