Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

NGEE Arctic Phase 4 Plant Functional Type Framework for Pan-Arctic Vegetation

The NGEE-Arctic research team identified a common set of hierarchical plant functional types (PFTs) for pan-arctic vegetation that we will use across our research activities. Interdisciplinary work within a large team requires agreement regarding levels of functional organization so that knowledge, data, and technologies can be shared and combined effectively. The team has identified plant functional types as a crucial area where such interoperability is needed. PFTs are used to represent plant pools and fluxes within models, summarize observational data, and map vegetation across the landscape. Within each of these applications, varying levels of PFT specificity are needed according to the specific scientific research goal, computational limitations, and data availability. By agreeing on a specific hierarchical framework for grouping variables in our vegetation data, we ensure the resulting research products will be robust, flexible, and scalable. In this document, we lay out the agreed upon PFT framework with definitions and references to existing literature. Table 1 included in the "NGA700_Phase4PFTFramework_about*" file outlines the relationship between NGEE-Arctic Phase 4, Tier 1 PFTs and the PFTs used within prominent arctic literature as well as publications by the NGEE-Arctic team during phases 1-3.This dataset consists of a table detailing a hierarchical PFT framework that spans 4 tiers with the most granular PFTs listed in tier 1 and the most general PFTs in tier 4. The PFTs within each tier has a single column in the dataset where the PFTs are named and a separate column where the characteristics used to define that PFT are listed. Grey fill of the cells is used to indicate where a given PFT starts to “lose” tier 1 details as you look from left to right. Note the excel file has merged cells to indicate grouping of PFTs across the Tiers- it will not translate into a delimited filetype (.csv, .txt, etc) without modification thus the hierarchical PFT framework table is available in three different file formats: 1) NGA700_Phase4PTS.xlsx – maintains the merged cells and grey fill; 2) NGA700_Phase4PTS.csv – merged cells are split, and grey fill is removed; 3) NGA700_Phase4PTS.pdf – image of the table with merged cells and grey fill. Metadata document included as a *.pdf and file-level metadata and data dictionary as *.csv files.

54 ENVIRONMENTAL SCIENCES↗

Regional and Seasonal Trends in Tropical Ozone from SHADOZ Profiles: Reference for Models and Satellite Products

Understanding lowermost stratosphere (LMS) ozone variability is an important topic in the trends and climate assessment communities because of feedbacks among changing temperature, dynamics, water vapor and ozone. LMS evaluations are usually based on satellite observations. Free tropospheric (FT) ozone assessments typically rely on profiles from commercial aircraft. Ozonesonde measurements constitute an independent dataset encompassing both LMS and FT. We used Southern Hemisphere Additional Ozonesondes (SHADOZ) data from 1998-2019 in the GSFC Multiple Linear Regression (MLR) model to analyze monthly mean FT and LMS ozone across five well-distributed tropical sites, three based on combination of nearby individual stations (Figure 1). Our findings: (1) both FT (defined as 5-15 km) and LMS (15-20 km) ozone trends exhibit marked regional and seasonal variability. (2) Stations with the largest FT ozone increases, in the equatorial Americas and western Pacific/east Indian Ocean, show these trends most strongly in February-May when there is convectively-driven wave activity. (3) LMS ozone losses are greatest in the 2nd half of the year (solid lines in Figure 2) when the losses are correlated with an increase in tropopause height (TH) as derived from SHADOZ radiosonde data. ( 4) When the upper FT and LMS are defined by tropopause-relative coordinates, the LMS ozone trend calculated by MLR becomes insignificant, as shown in the dashed lines in Figure 2. Thus, the 20-year decline in tropical LMS ozone reported in recent satellite- and model-based studies does not point to a chemical loss but is rather a signature of a tropopause that has been perturbed by a changing climate. Output based on our regional and monthly averaged FT and LMS ozone trends will be available as a reference for satellite- and model-based analyses.

Free Tropospheric (FT) ozone assessments↗

Applicability of Sentinel-1 Terrain Observation by Progressive Scans multitemporal interferometry for monitoring slow ground motions in the San Francisco Bay Area

Data from the Sentinel-1 satellite have already proven useful for investigating seismic and volcanic events since its launch in April 2014. The requirement of ultrahigh coregistration accuracy and the current relatively short time of Sentinel-1 acquisitions make its application challenging for studying slow deformation processes, such as fault creep and land subsidence. Here in this paper we analyze a set of 14 SAR images over the San Francisco Bay Area spanning 1 year from early 2015 to 2016. We show that implementing an existing Enhanced Spectral Diversity algorithm or using precise orbits together with a reference digital elevation model both yield the required coregistration accuracy for making use of the phase measurements in time series analysis of ground deformation. Following a thorough validation test, we update our estimates of Hayward Fault creep rate and confirm uplift due to recharge of the Santa Clara Valley aquifer system during the final summer of 4 year drought.

58 GEOSCIENCES↗

Bias Estimates Used in Lieu of Validation of Fission Products and Minor Actinides in MCNP K eff Calculations for PWR Burnup Credit Casks

The U.S. Nuclear Regulatory Commission (NRC) Division of Spent Fuel Storage and Transportation recently issued Interim Staff Guidance (ISG) 8, Revision 3. This ISG provides guidance for burnup credit (BUC) analyses supporting transport and storage of PWR pressurized water reactor (PWR) fuel in casks. Revision 3 includes guidance for addressing validation of criticality (k eff ) calculations crediting the presence of a limited set of fission products and minor actinides (FP&MA). Based on previous work documented in NUREG/CR-7109, recommendation 4 of ISG-8, Rev. 3, includes a recommendation to use 1.5 or 3% of the FP&MA worth to conservatively cover the bias due to the specified FP&MAs. This bias is supplementary to the bias and bias uncertainty resulting from validation of k eff calculations for the major actinides in SNF and does not address extension to actinides and fission products beyond those identified herein. The work described in this report involves comparison of FP&MA worths calculated using SCALE and MCNP with ENDF/B-V, -VI, and -VII based nuclear data and supports use of the 1.5% FP&MA worth bias when either SCALE or MCNP codes are used for criticality calculations, provided the other conditions of the recommendation 4 are met. The method used in this report may also be applied to demonstrate the applicability of the 1.5% FP&MA worth bias to other codes using ENDF/B V, VI or VII based nuclear data. The method involves use of the applicant s computational method to generate FP&MA worths for a reference SNF cask model using specified spent fuel compositions. The applicant s FP&MA worths are then compared to reference values provided in this report. The applicants FP&MA worths should not exceed the reference results by more than 1.5% of the reference FP&MA worths.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Experiment Test Plan

This document presents the test plan for the AGR-5/6/7 irradiation experiment, the combined fifth, sixth, and seventh irradiations of the United States Department of Energy Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The combined irradiation tests will consist of fuel qualification tests (AGR-5/6) and a margin test (AGR-7) for the industrially produced uranium oxycarbide (UCO) tristructural isotropic (TRISO) coated particle fuel developed by the AGR Program. The objective of the AGR-5/6/7 irradiation experiment is to establish the performance of UCO TRISO fuel fabricated using engineering-scale equipment in a production environment under and beyond normal operating conditions. Specifically, the goals of the AGR 5/6/7 irradiation experiment are: 1. Irradiate reference design fuel containing low-enriched UCO TRISO fuel particles to support fuel qualification. 2. Establish the operating margins for the fuel beyond normal operating conditions. 3. Provide irradiated fuel performance data and irradiated fuel samples for post-irradiation examination and safety testing. 4. Support the refinement of fuel performance and fission product transport models with online, post-irradiation examination and safety test data. In order to achieve the test objectives, the AGR-5/6/7 experiment will be irradiated in the northeast flux trap position of the Advanced Test Reactor at Idaho National Laboratory. The larger diameter of the northeast flux trap provides greater flexibility for test train design, significantly enhancing the capability for the combined irradiations. The test train contains five separate and independently controlled and monitored capsules. The middle capsule contains the AGR 7 margin test fuel. The two bottom and two top capsules contain the AGR 5/6 fuel. Each capsule contains a variable number of fuel compacts filled with UCO TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THERMAL ANALYSIS OF 3013/9975 CONFIGURATION

The 3013 containers are designed in accordance with the DOE-STD-3013-2004 and are qualified to store plutonium (Pu) bearing materials for 50 years. The U.S. Department of Energy (DOE) certified Model 9975 shipping package is used to transport the 3013 containers to the K-Area Material Storage (KAMS) facility at the Savannah River Site (SRS) and to store the containers until the plutonium can be properly dispositioned. Detailed thermal analyses to support the storage in the KAMS facility are given in References 2, 3, and 4. The analyses in this paper serve to provide non-accident condition, non-bounding, specific 3013 container temperatures for use in the surveillance activities. This paper presents a methodology where critical component temperatures are estimated using numerical methods over a range of package and storage parameters. The analyses include factors such as ambient storage temperature and the content weight, density, heat generation rate, and fill height, that may impact the thermal response of the packages. Statistical methods are used to develop algebraic equations for ease of computations to cover the factor space. All computations were performed in BTU-FT-Hr-{sup o}F units.

42 ENGINEERING↗

Revised Kimberlina Groundwater Simulations

Kimberlina Groundwater Qaulity Simulations (Version 3: 2015 October) by Lawrence Livermore National Labratory. Submitted to the EDX team at the National Energy Technology Laboratory for research use. This dataset contains 562 updated groundwater quality simulations based on the Kimberlina site. It is a six-layer model including the aquifers and aquitards inbetween the ground surface and the reservoir. The input files and associated leakage information for these simulations are included in the zip file "nrap_kim_well31_fluxes and inputs.tar.gz". These 562 simulations are the successful results out of 1000 monte carlo simulations, with time length greater than 5 years. Each simulation consists 6 output files, therefore, there are 3372 files (6*562) in total. One single example simulation of full time length (200 year) is also provided in the zip file "single_simulation_200yr_sim0012.tar.gz". These 6 groundwater quality parameters are: - pH (use absolute value) - TDS (mg/kg) - Pressure (Pa) - CO2 Liquid Saturation (fraction range 0.0-1.0) - CO2 Gas Concentration (mol/L) - CO2 Liquid Concentration (mol/kg) Their correponding file names, take the first simulation for example, are: ph0001.ntab (for pH) , tds0001.ntab (for TDS), usnt0001.p.ntab (for pressure), usnt0001.s_liquid.ntab (for liquid saturation), usnt0001.c_co2_gas.ntab (for CO2 gas concentration) and usnt0001.c_co2_liquid.ntab (for CO2 liquid concentration). Each output file contains at least 19 columns (variables). The total number of columns depends on the simulation time length. The column data include the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the jth grid of y-axis 4. k: the kth grid of z-axis 5. element_ref: element type reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The rest (14, 15, 16...) variables are the simulated parameter values over time, take pH as an example, are: 14. ph000y: initial pH value. 15. ph001y: simulated pH value at the end of the 1st year. 16. ph002y: simulated pH value at the end of the 2nd year. ... (and so on)... The zip input files have the input fluxes of brine and CO2 (in kg/s) allocated to model layers 1,2,3 and 5 (layers 4 and 6 are assumed to be no-flow aquitards) through the following nodes: (src1 WELL 7 7 25 25 10 32) #Etchegoin (src2 WELL 7 7 25 25 33 72) #Macoma Chanac (src3 WELL 7 7 25 25 73 83) #Santa Margarita Mclure (src4 WELL 7 7 25 25 84 89) #Fruitvale Round Mountain (aquitard) (src5 WELL 7 7 25 25 90 96) #Olcese Sand (thief zone) (src6 WELL 7 7 25 25 97 99) #tremblor Freeman (aquitard) ex: brn1 is assigned to src 1 from i=(7,7), j=(25,25), k=(10,32) Edited by Ya-Mei Yang at National Energy Technology Laboratory

brine leakage↗

Reference Model 3 Cost Breakdown (RM3: Wave Point Absorber)

Contains the Reference Model 3 (RM3) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM3 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 3 (RM3) is a wave point absorber, also referred to as a wave power buoy, that was designed for a reference site located off the shore of Eureka in Humboldt County, California. The design of the device consists of a surface float that translates (oscillates) with wave motion relative to a vertical column spar buoy, which connects to a subsurface reaction plate. This two-body point absorber converts wave energy into electrical power predominately from the devices heave oscillation induced by incident waves; the float is designed to oscillate up and down the vertical shaft up to 4 m. The bottom of the reaction plate is about 35 m below the water surface. The device is targeted for deployment in water depths of 40 m to 100 m. The point absorber is also connected to a mooring system to keep the floating device in position.

16 TIDAL AND WAVE POWER↗

Nuclear Criticality Safety Assessment of Criticality Control Containers without Moderation Control at the Waste Isolation Pilot Plant

The Waste Isolation Pilot Plant (WIPP) provides for safe, permanent disposal of government-owned transuranic (TRU) and TRU mixed wastes. Receipt and disposal of waste at the WIPP site began in March 1999. The Sandia report, Consideration of Nuclear Criticality When Disposing of Transuranic Waste at the Waste Isolation Pilot Plant, addressed potential nuclear criticality safety issues based on the projected inventory characteristics known at the time [1]. As designs for inventory, waste forms, and disposal packages have changed, new analyses have been performed, and updates have been made to address any potential effects to the WIPP safety basis. New analyses performed include Saylor 2017 [2] and Brickner 2019 [3], which address certain waste containers with specified loadings under post-closure conditions. Both examined several hypothetical scenarios and included analyses to bound (from a criticality potential standpoint) credible configurations that could occur at WIPP during the repository regulatory post-closure disposal time period for feature, event, and process (FEP) considerations—10,000 years. During this post-closure period at WIPP, the screening of FEPs is governed by the risk-based standards and implementing regulations of the US Environmental Protection Agency (EPA) (i.e., 40 CFR 191 and 40 CFR 194, respectively) [4,5]. An FEP screening can be based on either a low-consequence or low-probability rationale. A low-probability rationale includes either (a) a qualitative rationale that the FEP is not credible or (b) a quantitative demonstration that the probability is less than 10-4 in 104 years. In this evaluation, a qualitative lowprobability rationale of not credible is used by demonstrating that bounding configurations of the waste are not critical. The demonstration of subcriticality is through quantitative calculations, but a probability of criticality is not evaluated. Rather, the rationale for this evaluation is that bounding configurations with an effective neutron multiplication factor (keff) well below the upper subcriticality limit (USL) make criticality incredible. Reference [2] documented a nuclear criticality assessment of the WIPP repository for disposal of dilute surplus plutonium materials using the Dilute and Dispose Approach and packaging in criticality control overpacks (CCOs). The CCO is the waste disposal container recently designed to allow for up to 380 fissile gram equivalent (FGE) 239 Pu per drum, which is a higher fissile loading than typical waste containers. The CCO consists of a criticality control container (CCC) positioned by upper and lower plywood spacers within a standard 55 gal drum. The CCC is used to establish a geometry control for fissile materials during transportation and WIPP emplacement operations. The current WIPP waste acceptance criteria for CCO payloads limit beryllium to less than or equal to 1% by weight of the waste contents and require the waste form to be non-machine compacted. Reference [2] considered two scenario progressions—room closure from salt creep, hereafter referred to as the reconfigured dry scenario, and flooding with brine, hereafter referred to as the reconfigured wet scenario. The subsequent drying out of the reconfigured wet scenarios was also considered. For all scenarios, subcriticality was maintained when 50 g of B 4 C (acting as a neutron absorber) per CCC was intermixed within the plutonium disposition waste form. The analysis used a waste form description that limits the amount of moderation that could be present within the waste form (i.e., it limits the amount of water and polyethylene that could be present based on planned processing conditions). This analysis to evaluate increased limits on the amount of moderation that could be present was performed as a companion to Reference [2] to address concerns associated with verifying moisture and/or plastic contents of waste materials following packaging of dilute surplus plutonium in the CCO. To that end, this analysis used the models and methods from Reference [2] to evaluate a more generic base waste form consisting of water and polyethylene that is more similar (and nearly identical) to the generic waste forms utilized in other models/analyses supporting the TRU Package Transporter Model II (TRUPACTII) safety analysis [6] (all are without moderation controls). The waste form in this analysis uses a base mixture of 75% water and 25% polyethylene, the total amount of which is varied to determine the optimum moderation to fissile material (H/Pu) ratio. The fissile loading is maintained at up to 380 FGE 239 Pu (modeled as PuO 2 ) per CCO with an additional 545 g of beryllium (to bound the 1% by weight contents restriction) and 50 g of B 4 C intermixed per CCO. The beryllium content (1% by weight) is based on the total allowed waste weight (this does not include packaging and container weights). Figures ES-1 and ES-2 display summary results, showing that with this model including 50 g of B 4 C per CCO, the system keff remains under 0.85 for all moderator amounts and provides a significant margin against post-closure criticality under postulated bounding conditions for compaction. Figure ES-1 compares an infinite model with a room model at the initial emplacement spacing and under full radial compaction. Full radial compaction places each CCC in direct contact and does not credit any anticipated spacing associated with current post-closure geomechanical modeling of the repository [7]. The effects of variations in the H/Pu ratio were evaluated by varying the amount of the water/polyethylene component of the waste model, with fissile loading maintained at 380 239 Pu FGE. Similarly, Figure ES-2 illustrates how various amounts of B 4 C per CCO influence k eff at different radial compactions, all at the H/Pu ratio of 200 (in the room array model). Therefore, while the results from Saylor 2017 [2] modeled more realistic process limits associated with packaging of dilute surplus plutonium, this analysis demonstrates that limits on moderation (plastic and water content) are not necessary to ensure subcriticality in the WIPP repository, provided the requisite B 4 C absorber is present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetic modeling of [ 18 F]V AT , a novel radioligand for positron emission tomography imaging vesicular acetylcholine transporter in non‐human primate brain

Abstract Molecular imaging of vesicular acetylcholine transporter ( VACh T) in the brain provides an important cholinergic biomarker for the pathophysiology and treatment of dementias including Alzheimer's disease. In this study, kinetics modeling methods were applied and compared for quantifying regional brain uptake of the VACh T‐specific positron emission tomography radiotracer, ((−)‐(1‐(‐8‐(2‐fluoroethoxy)‐3‐hydroxy‐1,2,3,4‐tetrahydronaphthalen‐2‐yl)piperidin‐4‐yl)(4‐fluorophenyl)‐methanone) ([ 18 F]V AT ) in macaques. Total volume distribution ( V T ) estimates were compared for one‐tissue compartment model (1 TCM ), two‐tissue compartment model (2 TCM ), Logan graphic analysis (LoganA IF ) and multiple linear analysis (M A 1) with arterial blood input function using data from three macaques. Using the cerebellum‐hemispheres as the reference region with data from seven macaques, three additional models were compared: reference tissue model ( RTM ), simplified RTM ( SRTM ), and Logan graphic analysis (Logan REF ). Model selection criterion indicated that a) 2 TCM and SRTM were the most appropriate kinetics models for [ 18 F]V AT ; and b) S RTM was strongly correlated with 2 TCM (Pearson's coefficients r > 0.93, p < 0.05). Test–retest studies demonstrated that [ 18 F]V AT has good reproducibility and reliability ( TRV < 10%, ICC > 0.72). These studies demonstrate [ 18 F]V AT is a promising VACh T positron emission tomography tracer for quantitative assessment of VACh T levels in the brain of living subjects. image

Jin, Hongjun↗

Computation of infrared cooling rates in the water vapor bands

A fast but accurate method for calculating the infrared radiative terms due to water vapor has been developed. It makes use of the far wing approximation to scale transmission along an inhomogeneous path to an equivalent homogeneous path. Rather than using standard conditions for scaling, the reference temperatures and pressures are chosen in this study to correspond to the regions where cooling is most significant. This greatly increased the accuracy of the new method. Compared to line by line calculations, the new method has errors up to 4% of the maximum cooling rate, while a commonly used method based upon the Goody band model (Rodgers and Walshaw, 1966) introduces errors up to 11%. The effect of temperature dependence of transmittance has also been evaluated; the cooling rate errors range up to 11% when the temperature dependence is ignored. In addition to being more accurate, the new method is much faster than those based upon the Goody band model.

Chou, M. D.↗

A non-LTE treatment of beryllium lines - Misidentification of the solar Be I feature at 2650 A

The formation of beryllium lines, with particular reference to the solar Be spectrum, is investigated in a non-LTE context with a 25-level model atom in which 15 levels are allowed to depart from LTE. In some transitions, particularly the Be I 2650-A line, the non-LTE effects can be quite dramatic, changing the deduced abundances by a factor of 4. Based on the non-LTE calculations and Copernicus observations of other stars, it is found that a solar spectral feature at 2650 A, previously identified by numerous investigators as a Be I line, cannot be produced by Be I. Non-LTE effects on the Be II 3131-A line, used for most Be abundance determinations in the literature, are small by comparison.

Shipman, H. L.↗

Simulation of a Periodic Jet in a Crossflow with a RANS Solver Using an Unstructured Grid

A second-order unstructured-grid code, developed and used primarily for steady aerodynamic simulations, is applied to the synthetic jet in a cross flow. The code, FUN3D, is a vertex-centered finite-volume method originally developed by Anderson[1, 2], and is currently supported by members of the Fast Adaptive Aerospace Tools team at NASA Langley. Used primarily for design[3] and analysis[4] of steady aerodynamic configurations, FUN3D incorporates a discrete adjoint capability, and supports parallel computations using MPI. A detailed description of the FUN3D code can be found in the references given above. The code is under continuous development and contains a variety of flux splitting algorithms for the inviscid terms, two methods for computing gradients, several turbulence models, and several solution methodologies; all in varying states of development. Only the most robust and reliable components, based on experiences with steady aerodynamic simulations, were employed in this work. As applied in this work, FUN3D solves the Reynolds averaged Navier-Stokes equations using the one equation turbulence model of Spalart and Allmaras[5]. The spatial discretization is formed on unstructured meshes using a vertex-centered approach. The inviscid terms are evaluated by a flux-difference splitting formulation using least-squares reconstruction and Roe-type approximate Riemann fluxes. Green-Gauss gradient evaluations are used for viscous and turbulence modeling terms. The discrete spatial operator is combined with a backward time operator which is then solved iteratively using point or line Gauss-Seidel and local time stepping in a pseudo time. For steady flows, the physical time step is set to infinity and the pseudo time step is ramped up with the iteration count. A second-order backward in time operator is used for time accurate flows with 20 to 50 steps in the pseudo time applied at each physical time step. For this effort, FUN3D was modified to support spatially varying boundary and initial conditions, and unsteady boundary conditions. Also, a specialized in/out flow boundary condition was implemented to model the action of the diaphragm. This boundary condition is described below in more detail. The grids were generated using the internally developed codes GridEX[6] for meshing the surfaces and inviscid regions of the domain, and for CAD access; and MesherX[7] for meshing the viscous regions. Grid spacing in on the surfaces and in the inviscid regions are indirectly controlled by specifying sources. The viscous layers are generated using an advancing layer technique. MeshersX allows the user to control the spatial variation of the first step off the surface, growth rates, and the termination criterion by providing small problem dependent subroutines.

Atkins, H. L.↗

Isotopic Evidence for the Source and Fate of Phosphorus in Everglades Wetland Ecosystems

Phosphorus has historically been a limiting nutrient in the Florida Everglades. Increased P loading to the Everglades over the past several decades has led to significant changes in water quality and plant communities. Stormwater runoff that drains agricultural lands and enters the Water Conservation Areas (WCAs) are known to contain elevated levels of P, but the exact source of this P has not been fully determined. Here the results of an O isotope study of dissolved inorganic phosphate (DIP) in both polluted and relatively pristine (or reference) areas of the Everglades are reported. The data reveal spatial and temporal variations in the delta 18O signature of DIP, reflecting the source and the degree of cycling of P. The delta 18O values of DIP collected from the Everglades National Park were close or equal to the predicted delta 18O values of DIP formed in situ in equilibrium with ambient water, indicating that P is quickly cycled in the water column in oligotrophic ecosystems with very low P concentrations. However, most DIP samples collected from areas impacted by agricultural runoff yielded delta 18O values that deviated from the predicted equilibrium DIP delta 18O values based on the delta 18O of water and water temperature, suggesting that biological cycling of P was not rapid enough to remove the fertilizer ?18O signature in the DIP pool from areas receiving high P loading. The delta 18O signature of DIP in impacted areas reflects a mixing of fertilizer P and biologically cycled P, where the relative proportions of biologically cycled vs. fertilizer DIP are controlled by both biological (microbial activities and plant uptake) and hydrologic factors (loading rate and residence time). Using a two-end-member (i.e., fertilizer P and biologically cycled P) mixing model, fertilizers were estimated to contribute about 15 100% of the DIP pool in the highly impacted areas of the northern Everglades, whereas the DIP pool in the reference (i.e., relatively pristine) wetlands in the Everglades National Park was dominated by biologically cycled P. The study shows that O isotopic measurements of dissolved PO(exp 3-, sub 4) can be a useful tool for tracing the fertilizer P inputs to freshwater ecosystems.

Li, Xin↗

MODIS Reflective Solar Bands Lunar Calibration Update and Improvements

The MODerate resolution Imaging Spectroradiometer (MODIS) instruments on-board the Terra and Aqua spacecrafts were launched on December 18, 1999 and May 4, 2002, respectively. Each instrument has been scheduled to view the Moon through its Space View (SV) port approximately once per month in order to monitor the long-term radiometric stability of their reflective solar bands (RSB). The lunar calibration has played a key role in tracking the change in the response versus scan angle (RVS) of the instrument’s scan mirror, which is an essential part of the RSB calibration. The lunar irradiance observed by MODIS depends on the view geometry and it is crucial to remove the geometric effects in order to derive accurate RSB calibration coefficients. With a scheduled roll maneuver, the lunar phase angles are kept in a narrow range of 1° for each MODIS instrument such that the impact of these geometric effects is minimized. Nevertheless, it remains a challenge to completely remove the impact of geometric effects in the calibration coefficients derived from the lunar observations, considering the high expectations for the accuracy and quality of the results. In the current MODIS lunar calibration, the geometric effects on the lunar irradiance are corrected by the RObotic Lunar Observatory (ROLO) model. The overall relative uncertainty of the ROLO model for the MODIS calibration has been assessed to be about 1% in the selected lunar phase angle range of 1°. It could be as large as 4% beyond this small phase angle range, especially for the shortest wavelengths. This uncertainty induces noticeable oscillations in the calibration coefficients derived from the lunar observations. We developed a simple lunar model, which is based on MODIS lunar measurements, derived from scheduled lunar observations, as well as those obtained from intrusion of the Moon in the SV, referred to as unscheduled lunar observations, in the time period from 2005 to 2012. Here, the scheduled lunar observations for the entire mission are reprocessed with the new lunar model applied to correct the view geometry effects for each MODIS instrument. New calibration coefficients for the RSBs are calculated. We show that oscillations and noise in the derived lunar calibration coefficients are significantly reduced for both MODIS instruments.

Terra↗

System Response Testing of HEAF Kevex 130kV Microfocus Source and Thales Flashscan Panel I. Step-wedge Measurements

In the Small Sample DR Testing series, a few questions have arisen when comparing modeled results to experimental data. It is necessary to evaluate these questions in order to validate the modeling assumptions and to ensure the validity of the test procedure in the Small Sample DR Testing. Open Questions: (1) The decay time of the scintillator elements is unknown. (2) The thickness of the Beryllium window on the source is unknown. (3) The residual effects of beam angle and scattering within the detector assembly are unknown. (4) The spectral response of the scintillator and digitizing panel are not known. (5) The spectral content of the source is unknown. Item 1 will be addressed in separate tests by measuring the output of the panel at various intervals after the source has stopped illuminating the panel. Item 2 will be determined by finding the manufacturer specifications. Item 3 will be addressed in separate tests. We cannot easily address items 4 and 5 independently. Measuring the spectral responsivity of the detector directly would require the use of a calibrated reference source, which we lack. Similarly, measuring the spectral content of the source requires spectrally and spatially calibrated detectors, which we also lack. However, we can address the combination of items 1 and 2 to deduce the product of source intensity times detector response. By measuring the X-ray transmittance of samples of known thickness, material composition and density (step wedges), we can infer the desired product and so validate and improve computer models of our system.

47 OTHER INSTRUMENTATION↗

An Experimental Investigation of Fuel Staging In A Model Gas Turbine Combustor

Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged-stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τT Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a given τ Transient , the decay timescale decreased with increasing staging equivalence ratio. For 1, 16, and 58 ms transients, τ does not depend on τ Transient , though it does strongly depend on direction, where instability onset cases have longer and more variable τ than instability decay cases. The same dependence of τ on direction is seen for the 4,000 and 10,000 ms transients. However, unlike the short duration transients, τ does depend on τ Transient as would be expected. Phase space reconstruction shows the instability is a harmonic limit cycle with a single frequency. The instantaneous phase images shows the center region of the combustor goes out-of-phase first followed by the rest of the combustor. Finally, asymmetric fuel staging tests are conducted. It is found that non-axisymmetric staging can be as effective as axisymmetric staging, although small hardware variations between nozzles can affect the the minimum staging equivalence ratio that consistently suppresses the instability. These changes in the bifurcation equivalence ratio can make staging configurations appear less effective; however, both axisymmetric and non-axisymmetric staging configurations exhibit similar staged-stable p' RMS , damping rates, and instability transition times for equivalence ratios greater than the bifurcation equivalence ratio. Instantaneous phase images show similar instantaneous phase relationship structures in the staged nozzle (center or outer), suggesting that the instability suppression mechanism is similar in each case. This result is surprising given that the time-averaged flame shapes are very different between axisymmetric and non-axisymmetric staging configurations. The similar effectiveness of axisymmetric and non-axisymmetric staging in this geometry is attributed to the fact that the instability mode is a nominally axisymmetric plane wave. It is hypothesized that non-axisymmetric staging configurations will likely be more effective than axisymmetric staging configurations when the instability mode shape is asymmetric (such as a circumferential wave).

Culler, Wyatt↗

CARS diagnostics of the burning of H{sub 2} - O{sub 2} and CH{sub 4} - O{sub 2} mixtures at high temperatures and pressures

Coherent anti-Stokes Raman scattering (CARS) spectroscopy is used to determine the parameters of gaseous combustion products of hydrogen and hydrocarbon fuels with oxygen at high temperatures and pressures. The methodical aspects of CARS thermometry, which are related to the optimal choice of molecules (diagnostic references) and specific features of their spectra, dependent on temperature and pressure, are analysed. Burning is modelled under the conditions similar to those of real spacecraft propulsion systems using a specially designed laboratory combustion chamber, operating in the pulse-periodic regime at high temperatures (to 3500 K) and pressures (to 20 MPa) of combustion products. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗