Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 5”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Climate System Response to External Forcings and Climate Change Projections in CCSM4

Results are presented from experiments performed with the Community Climate System Model, version 4 (CCSM4) for the Coupled Model Intercomparison Project phase 5 (CMIP5). These include multiple ensemble members of twentieth-century climate with anthropogenic and natural forcings as well as single-forcing runs, sensitivity experiments with sulfate aerosol forcing, twenty-first-century representative concentration pathway (RCP) mitigation scenarios, and extensions for those scenarios beyond 2100–2300. Equilibrium climate sensitivity of CCSM4 is 3.20°C, and the transient climate response is 1.73°C. Global surface temperatures averaged for the last 20 years of the twenty-first century compared to the 1986–2005 reference period for six-member ensembles from CCSM4 are +0.85°, +1.64°, +2.09°, and +3.53°C for RCP2.6, RCP4.5, RCP6.0, and RCP8.5, respectively. The ocean meridional overturning circulation (MOC) in the Atlantic, which weakens during the twentieth century in the model, nearly recovers to early twentieth-century values in RCP2.6, partially recovers in RCP4.5 and RCP6, and does not recover by 2100 in RCP8.5. Heat wave intensity is projected to increase almost everywhere in CCSM4 in a future warmer climate, with the magnitude of the increase proportional to the forcing. Precipitation intensity is also projected to increase, with dry days increasing in most subtropical areas. For future climate, there is almost no summer sea ice left in the Arctic in the high RCP8.5 scenario by 2100, but in the low RCP2.6 scenario there is substantial sea ice remaining in summer at the end of the century.

54 ENVIRONMENTAL SCIENCES↗

SU-C-206-01: Impact of Charge Sharing Effect On Sub-Pitch Resolution for CZT-Based Photon Counting CT Systems

Purposes: Photon counting CT is a new imaging technology that can provide tissue composition information such as calcium/iodine content quantification. Cadmium zinc telluride CZT is considered a good candidate the photon counting CT due to its relatively high atomic number and band gap. One potential challenge is the degradation of both spatial and energy resolution as the fine electrode pitch is deployed (<50 µm). We investigated the extent of charge sharing effect as functions of gap width, bias voltage and depth-of-interaction (DOI). Methods: The initial electron cloud size and diffusion process were modeled analytically. The valid range of charge sharing effect refers to the range over which both signals of adjacent electrodes are above the triggering threshold (10% of the amplitude of 60keV X-ray photons). The intensity ratios of output in three regions (I1/I2/I3: left pixel, gap area and right pixel) were calculated. With Gaussian white noises modeled (a SNR of 5 based upon the preliminary experiments), the sub-pitch resolution as a function of the spatial position in-between two pixels was studied. Results: The valid range of charge sharing increases linearly with depth-of-interaction (DOI) but decreases with gap width and bias voltage. For a 1.5mm thickness CZT detector (pitch: 50µm, bias: 400 V), the range increase from ∼90µm up to ∼110µm. Such an increase can be attributed to a longer travel distance and the associated electron cloud broadening. The achievable sub-pitch resolution is in the range of ∼10–30µm. Conclusion: The preliminary results demonstrate that sub-pixel spatial resolution can be achieved using the ratio of amplitudes of two neighboring pixels. Such ratio may also be used to correct charge loss and help improve energy resolution of a CZT detector. The impact of characteristic X-rays hitting adjacent pixels (i.e., multiple interaction) on charge sharing is currently being investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscale 3D Liver Bioreactor for In Vitro Hepatotoxicity Testing under Perfusion Conditions

The accurate prediction of hepatotoxicity demands validated human in vitro models that can close the gap between preclinical animal studies and clinical trials. In this study we investigated the response of primary human liver cells to toxic drug exposure in a perfused microscale 3D liver bioreactor. The cellularized bioreactors were treated with 5, 10, or 30 mM acetaminophen (APAP) used as a reference substance. Lactate production significantly decreased upon treatment with 30 mM APAP (p < 0.05) and ammonia release significantly increased in bioreactors treated with 10 or 30 mM APAP (p < 0.0001), indicating APAP-induced dose-dependent toxicity. The release of prostaglandin E2 showed a significant increase at 30 mM APAP (p < 0.05), suggesting an inflammatory reaction towards enhanced cellular stress. The expression of genes involved in drug metabolism, antioxidant reactions, urea synthesis, and apoptosis was differentially influenced by APAP exposure. Histological examinations revealed that primary human liver cells in untreated control bioreactors were reorganized in tissue-like cell aggregates. These aggregates were partly disintegrated upon APAP treatment, lacking expression of hepatocyte-specific proteins and transporters. In conclusion, our results validate the suitability of the microscale 3D liver bioreactor to detect hepatotoxic effects of drugs in vitro under perfusion conditions.

42 ENGINEERING↗

Report of the 90-day study on human exploration of the Moon and Mars

The basic mission sequence to achieve the President's goal is clear: begin with Space Station Freedom in the 1990's, return to the Moon to stay early in the Next century, and then journey to Mars. Five reference approaches are modeled building on past programs and recent studies to reflect wide-ranging strategies that incorporate varied program objectives, schedules, technologies, and resource availabilities. The reference approaches are (1) balance and speed; (2) the earliest possible landing on Mars; (3) reduce logistics from Earth; (4) schedule adapted to Space Station Freedom; and (5) reduced scales. The study and programmatic assessment have shown that the Human Exploration Initiative is indeed a feasible approach to achieving the President's goals. Several reasonable alternatives exist, but a long-range commitment and significant resources will be required. However, the value of the program and the benefits to the Nation are immeasurable.

Aaron Cohen↗

Measurement of thermal gap conductance using the laser flash method

Thermal gap conductance refers to overall heat conductance through a gas-filled gap as interface thermal resistance between the gas and surface has to be considered. The analysis of new ATR (Advanced Test Reactor) fuel experiments requires experimental data and models for the gap conductance of the cladding/fuel capsule gap, which typically varies from 5 μm to 50 μm and is filled with He at 1-3 atm. Although past research has studied the gap conductance between UO{sub 2} fuel and Zircaloy cladding, new experiments are needed to provide the gap conductance data between HT9 and stainless steel 316, and between advanced fuels and advanced cladding in the Accident Tolerant Fuels program. In this paper, the laser flash method is modified to measure the gap conductance. The gap is formed by welding two stainless steel 316 disks with three spacers. The temperature at the rear surface, after exposure to the laser pulse at the front surface, is modeled with 1D heat transfer through three layers. The analytic solution is then fitted with the measured temperature to determine gap conductance. The sensitivity analysis based on the 1D assumption and 3D numerical simulations were performed to assess the sensitivity and uncertainty of the measurement. It is concluded the heat capacity of the gas in the gap has minimal impact on the measurement, which indicates that the thermal property determined by this method is the thermal conductance, instead of the thermal diffusivity. Convective heat loss through sidewalls under the current experimental design has insignificant influences. Heat transfer through spacers may cause up to 10% overestimation of thermal gap conductance, but the effects can be mostly eliminated by the design of grooves on samples. The result established a pathway for gap conductance determination. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PVWatts Version 5 Manual

The NREL PVWatts calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes includes several built-in parameters that are hidden from the user. This technical reference describes the sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimate. This reference is applicable to the significantly revised version of PVWatts released by NREL in 2014.

14 SOLAR ENERGY↗

A Reference Model for Software and System Inspections. White Paper

Software Quality Assurance (SQA) is an important component of the software development process. SQA processes provide assurance that the software products and processes in the project life cycle conform to their specified requirements by planning, enacting, and performing a set of activities to provide adequate confidence that quality is being built into the software. Typical techniques include: (1) Testing (2) Simulation (3) Model checking (4) Symbolic execution (5) Management reviews (6) Technical reviews (7) Inspections (8) Walk-throughs (9) Audits (10) Analysis (complexity analysis, control flow analysis, algorithmic analysis) (11) Formal method Our work over the last few years has resulted in substantial knowledge about SQA techniques, especially the areas of technical reviews and inspections. But can we apply the same QA techniques to the system development process? If yes, what kind of tailoring do we need before applying them in the system engineering context? If not, what types of QA techniques are actually used at system level? And, is there any room for improvement.) After a brief examination of the system engineering literature (especially focused on NASA and DoD guidance) we found that: (1) System and software development process interact with each other at different phases through development life cycle (2) Reviews are emphasized in both system and software development. (Figl.3). For some reviews (e.g. SRR, PDR, CDR), there are both system versions and software versions. (3) Analysis techniques are emphasized (e.g. Fault Tree Analysis, Preliminary Hazard Analysis) and some details are given about how to apply them. (4) Reviews are expected to use the outputs of the analysis techniques. In other words, these particular analyses are usually conducted in preparation for (before) reviews. The goal of our work is to explore the interaction between the Quality Assurance (QA) techniques at the system level and the software level.

He, Lulu↗

Modeling laser wakefield accelerators in a Lorentz boosted frame

Modeling of laser-plasma wakefield accelerators in an optimal frame of reference is shown to produce orders of magnitude speed-up of calculations from first principles. Obtaining these speedups requires mitigation of a high-frequency instability that otherwise limits effectiveness in addition to solutions for handling data input and output in a relativistically boosted frame of reference. The observed high-frequency instability is mitigated using methods including an electromagnetic solver with tunable coefficients, its extension to accomodate Perfectly Matched Layers and Friedman's damping algorithms, as well as an efficient large bandwidth digital filter. It is shown that choosing the frame of the wake as the frame of reference allows for higher levels of filtering and damping than is possible in other frames for the same accuracy. Detailed testing also revealed serendipitously the existence of a singular time step at which the instability level is minimized, independently of numerical dispersion, thus indicating that the observed instability may not be due primarily to Numerical Cerenkov as has been conjectured. The techniques developed for Cerenkov mitigation prove nonetheless to be very efficient at controlling the instability. Using these techniques, agreement at the percentage level is demonstrated between simulations using different frames of reference, with speedups reaching two orders of magnitude for a 0.1 GeV class stages. The method then allows direct and efficient full-scale modeling of deeply depleted laser-plasma stages of 10 GeV-1 TeV for the first time, verifying the scaling of plasma accelerators to very high energies. Over 4, 5 and 6 orders of magnitude speedup is achieved for the modeling of 10 GeV, 100 GeV and 1 TeV class stages, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NASTRAN User's Manual Level 16.0 and Supplement

The user's manual is restricted to those items related to the use of NASTRAN that are independent of the computing system being used. The features of NASTRAN described include: (1) procedures for defining and loading a structural model and a functional reference for every card that is used for structural modeling; (2) the NASTRAN data deck, including the details for each of the data cards; (3) the NASTRAN control cards that are associated with the use of the program; (4) rigid format procedures, along with specific instructions for the use of each rigid format: (5) procedures for using instructions for the use of each rigid format; (5) procedures for using the NASTRAN plotting capability; (6) procedures governing the creation of DMAP programs; and (7) the NASTRAN diagnostic messages. The NASTRAN dictionary of mnemonics, acronyms, phrases, and other commonly used NASTRAN terms is included along with a limited number of sample problems.

Source record↗

An Inverse Heat Conduction Algorithm Used to Calculate the Temperatures on the Inner and Outer Cylindrical Surfaces of an HMX-based PBX Explosive Annulus

In this work, a new Inverse Heat Conduction (IHC) algorithm is applied to estimate the surface temperatures at twelve locations on the inner and outer cylindrical boundaries of an HMX-based Plastic Bonded Explosive (PBX) annulus. This IHC algorithm was developed in references using a set of Direct Heat Conduction (DHC) solutions and a temperature correction method. The DHC solutions were calculated using a Galerkin based finite element (FE) method. This HMX based PBX annulus was used in the Large Scale Annular Cookoff (LSAC) experiment, Shot 5. The reason Shot 5 was chosen as a prototype mathematical model for this study is that the temperature was measured at eighteen locations in the midplane of the HMX-based PBX annulus. In addition, this annulus underwent an experimental thermal ignition and a deflagration that caused a thermal explosion and the disassembly of the experiment. The objective of this study is to describe how the application of the temperature correction algorithm produced the convergence of the DHC solutions to the measured temperatures at twelve internal locations in the midplane of the HMX-based PBX annulus.

36 MATERIALS SCIENCE↗

Satellite power system (SPS) magnetron tube assessment study

Taks performed to extend the data base and to define a technology development program for the magnetron directional amplifier for the SPS are reviewed. These include: (1) demonstrating the tracking of phase and amplitude of the microwave output to phase and amplitude references; (2) expanding the range of power over which the directional amplifier will operate; (3)recognizing the importance of amplitude control in overall system design and in simplifying power conditioning; (4) developing a preliminary design for the overall architecture of the power module; (5) demonstrating magnetron starting using the amplitude control system; (6) mathematically modelling and performing a computerized study of the pyrolytic graphite radiating fin; (7) defining the mass of the magnetic circuit for the SPS tube; (8) noise measurement; (9) achieving harmonic suppression by notch reflection filters; (10) estimating the mass of the transmitting antenna; (11) developing a magnetron package with power generation, phase control, and power condition functions; and (12) projecting magnetron package characteristics.

Source record↗

Evaluation of High-Performance Space Nuclear Electric Generators for Electric Propulsion Application

Electric propulsion applications are enhanced by high power-to-mass ratios for their electric power sources. At multi-megawatt levels, we can expect thrust production systems to be less than 5 kg/kWe. Application of nuclear electric propulsion to human Mars missions becomes an attractive alternative to nuclear thermal propulsion if the propulsion system is less than about 10 kg/kWe. Recent references have projected megawatt-plus nuclear electric sources at specific mass values from less than 1 kg/kWe to about 5 kg/kWe. Various assumptions are made regarding power generation cycle (turbogenerator; MHD (magnetohydrodynamics)) and reactor heat source design. The present paper compares heat source and power generation options on the basis of a parametric model that emphasizes heat transfer design and realizable hardware concept. Pressure drop (important!) is included in the power cycle analysis, and MHD and turbogenerator cycles are compared. Results indicate that power source specific mass less than 5 kg/kWe is attainable, even if peak temperatures achievable are limited to 1500 K. Projections of specific mass less than 1 kg/kWe are unrealistic, even at the highest peak temperatures considered.

Woodcock, Gordon↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Artemis IV

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D Hilmers↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Late Artemis Missions

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D. Hilmers↗

SU‐C‐105‐05: Reference Dosimetry of High‐Energy Electron Beams with a Farmer‐Type Ionization Chamber

Purpose: To investigate gradient effects and provide Monte Carlo calculated beam quality conversion factors to characterize the Farmer‐type NE2571 ion chamber for high‐energy reference dosimetry of clinical electron beams. Methods: The EGSnrc code system is used to calculate the absorbed dose to water and to the gas in a fully modeled NE2571 chamber as a function of depth in a water phantom. Electron beams incident on the surface of the phantom are modeled using realistic BEAMnrc accelerator simulations and electron beam spectra. Beam quality conversion factors are determined using calculated doses to water and to air in the chamber in high‐energy electron beams and in a cobalt‐60 reference field. Calculated water‐to‐air stopping power ratios are employed for investigation of the overall ion chamber perturbation factor. Results: An upstream shift of 0.3–0.4 multiplied by the chamber radius, r-cav, both minimizes the variation of the overall ion chamber perturbation factor with depth and reduces the difference between the beam quality specifier (R{sub 5} {sub 0}) calculated using ion chamber simulations and that obtained with simulations of dose‐to‐water in the phantom. Beam quality conversion factors are obtained at the reference depth and gradient effects are optimized using a shift of 0.2r-cav. The photon‐electron conversion factor, k-ecal, amounts to 0.906 when gradient effects are minimized using the shift established here and 0.903 if no shift of the data is used. Systematic uncertainties in beam quality conversion factors are investigated and amount to between 0.4 to 1.1% depending on assumptions used. Conclusion: The calculations obtained in this work characterize the use of an NE2571 ion chamber for reference dosimetry of high‐energy electron beams. These results will be useful as the AAPM continues to review their reference dosimetry protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning System Calculation Errors Are Present in Most Imaging and Radiation Oncology Core-Houston Phantom Failures

Purpose: The anthropomorphic phantom program at the Houston branch of the Imaging and Radiation Oncology Core (IROC-Houston) is an end-to-end test that can be used to determine whether an institution can accurately model, calculate, and deliver an intensity modulated radiation therapy dose distribution. Currently, institutions that do not meet IROC-Houston's criteria have no specific information with which to identify and correct problems. In the present study, an independent recalculation system was developed to identify treatment planning system (TPS) calculation errors. Methods and Materials: A recalculation system was commissioned and customized using IROC-Houston measurement reference dosimetry data for common linear accelerator classes. Using this system, 259 head and neck phantom irradiations were recalculated. Both the recalculation and the institution's TPS calculation were compared with the delivered dose that was measured. In cases in which the recalculation was statistically more accurate by 2% on average or 3% at a single measurement location than was the institution's TPS, the irradiation was flagged as having a “considerable” institutional calculation error. The error rates were also examined according to the linear accelerator vendor and delivery technique. Results: Surprisingly, on average, the reference recalculation system had better accuracy than the institution's TPS. Considerable TPS errors were found in 17% (n=45) of the head and neck irradiations. Also, 68% (n=13) of the irradiations that failed to meet the IROC-Houston criteria were found to have calculation errors. Conclusions: Nearly 1 in 5 institutions were found to have TPS errors in their intensity modulated radiation therapy calculations, highlighting the need for careful beam modeling and calculation in the TPS. An independent recalculation system can help identify the presence of TPS errors and pass on the knowledge to the institution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beyond leading twist: 𝜌 meson decay constants and distribution amplitudes in a self-consistent light-front quark model

In this study, we present a comprehensive analysis of decay constants and chiral-even and chiral-odd distribution amplitudes (DAs) up to twist 4 for the 𝜌 meson in the standard light-front quark model (LFQM) based on the Bakamjian-Thomas (BT) construction. For the 𝜌 meson, which possesses both longitudinal (ℎ=0) and transverse (ℎ =±1) polarizations, two types of decay constants, 𝑓$^{∥}_{𝜌}$ and 𝑓$^{⊥}_{𝜌}$, arises accordingly. We demonstrate that these decay constants can be self-consistently extracted from both local (𝑧𝜇 =0) and nonlocal (𝑧𝜇 ≠0) matrix elements ⟨0⁢|$\overline{𝑞}$(𝑧)⁢Γ⁢𝑞⁡(−𝑧)|⁢𝜌⁡(𝑃,ℎ)⟩, with Γ=(𝛾 𝜇 ,𝜎 𝜇⁢𝜈 ,𝛾 𝜇 ⁢𝛾 5 ,𝟏), in a manner independent of current components, polarizations, and reference frames. In particular, we emphasize the role of nonlocal matrix elements involving axial-vector and scalar currents, where mixing between 𝑓$^{∥}_{𝜌}$ and 𝑓$^{⊥}_{𝜌}$ occurs. We show that this mixing is consistently resolved through the BT construction, ensuring the proper extraction of these decay constants.

Electroweak interaction↗

Revised Kimberlina Groundwater Simulations

Kimberlina Groundwater Qaulity Simulations (Version 3: 2015 October) by Lawrence Livermore National Labratory. Submitted to the EDX team at the National Energy Technology Laboratory for research use. This dataset contains 562 updated groundwater quality simulations based on the Kimberlina site. It is a six-layer model including the aquifers and aquitards inbetween the ground surface and the reservoir. The input files and associated leakage information for these simulations are included in the zip file "nrap_kim_well31_fluxes and inputs.tar.gz". These 562 simulations are the successful results out of 1000 monte carlo simulations, with time length greater than 5 years. Each simulation consists 6 output files, therefore, there are 3372 files (6*562) in total. One single example simulation of full time length (200 year) is also provided in the zip file "single_simulation_200yr_sim0012.tar.gz". These 6 groundwater quality parameters are: - pH (use absolute value) - TDS (mg/kg) - Pressure (Pa) - CO2 Liquid Saturation (fraction range 0.0-1.0) - CO2 Gas Concentration (mol/L) - CO2 Liquid Concentration (mol/kg) Their correponding file names, take the first simulation for example, are: ph0001.ntab (for pH) , tds0001.ntab (for TDS), usnt0001.p.ntab (for pressure), usnt0001.s_liquid.ntab (for liquid saturation), usnt0001.c_co2_gas.ntab (for CO2 gas concentration) and usnt0001.c_co2_liquid.ntab (for CO2 liquid concentration). Each output file contains at least 19 columns (variables). The total number of columns depends on the simulation time length. The column data include the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the jth grid of y-axis 4. k: the kth grid of z-axis 5. element_ref: element type reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The rest (14, 15, 16...) variables are the simulated parameter values over time, take pH as an example, are: 14. ph000y: initial pH value. 15. ph001y: simulated pH value at the end of the 1st year. 16. ph002y: simulated pH value at the end of the 2nd year. ... (and so on)... The zip input files have the input fluxes of brine and CO2 (in kg/s) allocated to model layers 1,2,3 and 5 (layers 4 and 6 are assumed to be no-flow aquitards) through the following nodes: (src1 WELL 7 7 25 25 10 32) #Etchegoin (src2 WELL 7 7 25 25 33 72) #Macoma Chanac (src3 WELL 7 7 25 25 73 83) #Santa Margarita Mclure (src4 WELL 7 7 25 25 84 89) #Fruitvale Round Mountain (aquitard) (src5 WELL 7 7 25 25 90 96) #Olcese Sand (thief zone) (src6 WELL 7 7 25 25 97 99) #tremblor Freeman (aquitard) ex: brn1 is assigned to src 1 from i=(7,7), j=(25,25), k=(10,32) Edited by Ya-Mei Yang at National Energy Technology Laboratory

brine leakage↗