Search NASA⌕ Search

SEARCH · Search NASA

Results for “Refilling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

300 records · Page 17

Water reactive hydrogen fuel cell power system

A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

08 HYDROGEN↗

Factors influencing helium measurements for detection of control rod failures in BWR

Much effort has been made to minimize the number and consequences of fuel failures at nuclear power plants. The consequences of control rod failures have also gained an increased attention. In this paper we introduce a system for on-line surveillance of control rod integrity which has several advantages comparing to the surveillance methods available today in boiling water reactors (BWRs). This system measures the helium released from failed control rods containing boron carbide (B4C). However, there are a number of factors that might influence measurements, which have to be taken into consideration when evaluating the measured data. These factors can be separated into two groups: 1) local adjustments, made on the sampling line connecting the detector to the off-gas system, and 2) plant operational parameters. The adjustments of the sample line conditions include variation of gas flow rate and gas pressure in the line. Plant operational factors that may influence helium measurements can vary from plant to plant. The factors studied at Leibstadt nuclear power plant (KKL) were helium impurities in injected hydrogen gas, variation of the total off-gas flow and regular water refill. In this paper we discuss these factors and their significance and present experimental results of measurements at KKL. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The power of simplification: Operator interface with the AP1000{sup R} during design-basis and beyond design-basis events

The AP1000{sup R} plant is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and cost. The passive safety features are designed to function without safety-grade support systems such as component cooling water, service water, compressed air or HVAC. The AP1000 passive safety features achieve and maintain safe shutdown in case of a design-basis accident for 72 hours without need for operator action, meeting the expectations provided in the European Utility Requirements and the Utility Requirement Document for passive plants. Limited operator actions may be required to maintain safe conditions in the spent fuel pool (SFP) via passive means. This safety approach therefore minimizes the reliance on operator action for accident mitigation, and this paper examines the operator interaction with the Human-System Interface (HSI) as the severity of an accident increases from an anticipated transient to a design basis accident and finally, to a beyond-design-basis event. The AP1000 Control Room design provides an extremely effective environment for addressing the first 72 hours of design-basis events and transients, providing ease of information dissemination and minimal reliance upon operator actions. Symptom-based procedures including Emergency Operating Procedures (EOPs), Abnormal Operating Procedures (AOPs) and Alarm Response Procedures (ARPs) are used to mitigate design basis transients and accidents. Use of the Computerized Procedure System (CPS) aids the operators during mitigation of the event. The CPS provides cues and direction to the operators as the event progresses. If the event becomes progressively worse or lasts longer than 72 hours, and depending upon the nature of failures that may have occurred, minimal operator actions may be required outside of the control room in areas that have been designed to be accessible using components that have been designed to be reliable in these conditions. The primary goal of any such actions is to maintain or refill the passive inventory available to cool the core, containment and spent fuel pool in the safety-related and seismically qualified Passive Containment Cooling Water Storage Tank (PCCWST). The seismically-qualified, ground-mounted Passive Containment Cooling Ancillary Water Storage Tank (PCCAWST) is also available for this function as appropriate. The primary effect of these actions would be to increase the coping time for the AP1000 during design basis events, as well as events such as those described above, from 72 hours without operator intervention to 7 days with minimal operator actions. These Operator actions necessary to protect the health and safety of the public are addressed in the Post-72 Hour procedures, as well as some EOPs, AOPs, ARPs and the Severe Accident Management Guidelines (SAMGs). Should the event continue to become more severe and plant conditions degrade further with indications of inadequate core cooling, the SAMGs provide guidance for strategies to address these hypothetical severe accident conditions. The AP1000 SAMG diagnoses and actions are prioritized to first utilize the AP1000 features that are expected to retain a damaged core inside the reactor vessel. Only one strategy is undertaken at any time. This strategy will be followed and its effectiveness evaluated before other strategies are undertaken. This is a key feature of both the symptom-oriented AP1000 EOPs and the AP1000 SAMGs which maximizes the probability of retaining a damaged core inside the reactor vessel and containment while minimizing the chances for confusion and human errors during implementation. The AP1000 SAMGs are simple and straight-forward and have been developed with considerable input from human factors and plant operations experts. Most importantly, and different from severe accident management strategies for other plants, the AP1000 SAMGs do not require diagnosis of the location of the core (i.e., whether reactor vessel failure has occurred). This is a fundamental consequence of the AP1000 In-Vessel Retention approach, which allows severe accident management to be based on fundamental principles (e.g. provide coolant as close as possible to the core) that do not change during a specific event. This eliminates the need for one of the more difficult diagnostic requirements, since reactor vessel failure does not directly relate to any measurable plant parameter, and differs from other designs in that an engineered failure of the pressure vessel' (e.g. core catcher) is never required. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRACE and TRAC-BF1 benchmark against Leibstadt plant data during the event inadvertent opening of relief valves

In framework of introducing TRACE code to transient analyses system codes for Leibstadt Power Plant (KKL), a conversion process of existing TRAC-BF1 model to TRACE has been started within KKL. In the first step, TRACE thermal-hydraulic model for KKL has been developed based on existing TRAC-BF1 model. In order to assess the code models a simulation of plant transient event is required. In this matter simulations of inadvertent opening of 8 relief valves event have been performed. The event occurs at KKL during normal operation, and it started when 8 relief valves open resulting in depressurization of the Reactor Pressure Vessel (RPV). The reactor was shutdown safely by SCRAM at low level. The high pressure core spray (HPCS) and the reactor core isolation cooling (RCIC) have been started manually in order to compensate the level drop. The remaining water in the feedwater (FW) lines flashes due to saturation conditions originated from RPV depressurization and refills the reactor downcomer. The plant boundary conditions have been used in the simulations and the FW flow rate has been adjusted for better prediction. The simulations reproduce the plant data with good agreement. It can be concluded that the TRAC-BF1 existing model has been used successfully to develop the TRACE model and the results of the calculations have shown good agreement with plant recorded data. Beside the modeling assessment, the TRACE and TRAC-BF1 capabilities to reproduce plant physical behavior during the transient have shown satisfactory results. The first step of developing KKL model for TRACE has been successfully achieved and this model is further developed in order to simulate more complex plant behavior such as Turbine Trip. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRACE Code Validation of BWR SVEA Fuel Assembly Spray Cooling

Emergency spray cooling injection is a safety feature implemented in many boiling water reactor designs to reflood a reactor during an accident. Significant experimental work has qualified the efficacy of spray cooling, and ongoing computational modeling efforts strive to more accurately portray the phenomena involved. This work examines the physical phenomena pertaining to emergency spray cooling injection over SVEA-type fuel assemblies. BWR emergency core cooling system (ECCS) designs commonly incorporate a Low-Pressure Core Spray (LPCS) system that introduces coolant through spray nozzles directed to the top of the core, and are located in the upper plenum region. This design is effective for LOCA response, particularly during the initial refill and reflood stages of accident response where the goal is limiting the peak cladding temperature rise in the core. The U.S. NRC thermal-hydraulics code TRACE version 5.0 Patch 4 has been chosen to simulate the separate-effect tests performed by ASEA-ATOM. The computational model was evaluated by performing forward uncertainty quantification using Dakota as the analysis tool and code driver on 31 identified parameters from the input model and TRACE physical constitutive models. This paper discusses the sensitivity of the investigated parameters with respect to spray cooling simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RoboCount{sup TM} 2020 - A Robotic Non-Destructive Waste Assay System - 19331

A robotic system for non-destructive assay of radioactive waste - RoboCount{sup TM} 2020ab - has been designed, manufactured, and a prototype delivered to a customer. RoboCount{sup TM} 2020 is based on an industrial 6-axis articulating robot platform, combined with a dedicated waste package platform and a high-resolution HPGe gamma spectrometer. The system enables measurement of waste packages including drums (100-l, 200-l, 400-l), crates (up to 1200 x 800 x 800 mm), 1 m{sup 3} flexible intermediate bulk containers (FIBC), and others. Assay type can be freely defined, ranging from currently accepted protocols such as segmented gamma scan (SGS) or integral gamma scan (IGS) to new protocols developed for specific non-cylindrical waste packages, e.g., measurement of FIBCs from all four sides and the top. As a result of the robotic hardware flexibility, reconfiguration of the system for a new task is a matter of software changes only. In addition, while primarily geared towards waste characterization, the system can be configured for free release (clearance) by installing a second detector and field-of-view shielding. The prototype is currently in operation at a NPP site in Europe where it is used for D and D waste characterization in crates and FIBCs. Additional features beyond the basic functionality have been implemented such as an automatic lead collimator change based on measured HPGe detector dead time and an automatic liquid nitrogen refill, performed by the robot via a docking station at predefined time intervals. (Use of electrically cooled HPGe detectors is also possible). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Field Measurement on UF6 Cylinders Using Electro-Mechanically Cooled Systems

Measurement of the enrichment of solid state UF6 stored within large metal cylinders is a task commonly performed by plant operators and inspectors. The measurement technologies typically used range from low-resolution, high-efficiency sodium iodide detectors to high-resolution, moderate-efficiency high-purity germanium (HPGe) detectors. The technology used and methods deployed are dependent upon the material being measured, environmental conditions, time constraints, and measurement-precision requirements. Operators and inspectors typically use specially designed, HPGe detectors that are cooled with liquid nitrogen in situations where high-resolution measurements are required. However, the requirement for periodically refilling the system with liquid nitrogen makes remote usage cumbersome and slow. The task of cooling the detector reduces the available time for the inspector to perform other safeguards activities while on site. If the inspector has to reduce the count time for each selected cylinder to ensure that all preselected cylinders are measured during the inspection, the resulting measurement uncertainties may be increased, making it more difficult to detect and verify potential discrepancies in the operator's declarations. However, recent advances in electromechanically cooled HPGe detectors may provide the inspector with an improved verification tool by eliminating the need for liquid nitrogen. This report provides a summary of test results for field measurements performed using electromechanically cooled HPGe detectors on depleted, natural, and low-enriched uranium cylinders. The results of the study provide valuable information to inspectors and operators regarding the capabilities and limitations of electromechanically cooled systems based on true field-measurement conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Mechanically-Cooled, Highly-Portable, HPGe-Based, Coded-Aperture Gamma-Ray Imager

Coded-aperture gamma-ray imaging is a mature technology that is capable of providing accurate and quantitative images of nuclear materials. Although it is potentially of high value to the safeguards and arms-control communities, it has yet to be fully embraced by those communities. One reason for this is the limited choice, high-cost, and low efficiency of commercial instruments; while instruments made by research organizations are frequently large and / or unsuitable for field work. In this paper we present the results of a project that mates the coded-aperture imaging approach with the latest in commercially-available, position-sensitive, High Purity Germanium (HPGe) detec-tors. The instrument replaces a laboratory prototype that, was unsuitable for other than demonstra-tions. The original instrument, and the cart on which it is mounted to provide mobility and pointing capabilities, has a footprint of ~ 2/3 m x 2 m, weighs ~ 100 Kg, and requires cryogen refills every few days. In contrast, the new instrument is tripod mounted, weighs of order 25 Kg, operates with a laptop computer, and is mechanically cooled. The instrument is being used in a program that is ex-ploring the use of combined radiation and laser scanner imaging. The former provides information on the presence, location, and type of nuclear materials while the latter provides design verification information. To align the gamma-ray images with the laser scanner data, the Ge imager is fitted and aligned to a visible-light stereo imaging unit. This unit generates a locus of 3D points that can be matched to the precise laser scanner data. With this approach, the two instruments can be used completely independently at a facility, and yet the data can be accurately overlaid based on the very structures that are being measured.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Separating Oil-Water Mixtures Using Bump Arrays

Particle separation is an important process step across many fields. One technique being applied for separating solids such as blood components or sand particles from carrier fluids is the use of arrays of aligned posts called deterministic lateral arrays to bump particles to one side in the flow stream to enhance separation. This technique may be useful for separation of deformable particles. The ability to efficiently separate two-phase industrial (oil/water) mixtures is key for future use of valuable resources. Over 1 trillion gallons of petroleum production water could be reclaimed annually for reuse in the drought-ridden western US states. The ability to reclaim this petroleum production water may be critical for the Central High Plains (Colorado, Kansas, Oklahoma, Texas, and New Mexico). Trends in just the High Plains area already lost 20 to 25% of the irrigated farming area due to insufficient ground water storage to irrigate, and farmland losses are expected to grow to 40%. Proving this technology is key to reuse of petroleum production water for crop irrigation or to replace water from currently failing aquifers in rich agricultural lands of the Central High Plains. We conducted experiments applying mesofluidic separation for flowing two-phase (oil/water) mixtures. Experiments were conducted using oils of differing viscosities with water as the carrier fluid; separation was achieved over a range of oil-water concentrations. We describe the results of these experiments in this paper.

oil-water separation, micelle, droplet separation,↗

The Breathing Plasmasphere

Explore the source record for details and available documents.

Plasmasphere, refilling, erosion, imaging↗