SEARCH · Search NASA
Results for “Rejection”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Actinide in Air (Rn-Progeny Rejected) Alpha Spectroscopy With Tensioned Metastable Fluid Detectors
Here, this article discusses outcome of research for deriving a methodology and apparatus for ascertaining for the presence of ultratrace-level actinides in air from their alpha emission signatures, while remaining blind to the relatively large (1000× higher activity) alpha emissions from Rn-progeny. Apparatus and techniques were developed to collect and characterize alpha-emitting nuclides of Rn-progeny and actinides in air on a polycarbonate 3 μm pore size continuous air monitor (CAM) filter. A wet-chemistry approach was developed and validated for successfully separating the Rn-progeny alpha emitting isotopes of Po-214 and Po-218, while extracting the actinides (U, Pu, Am) in a fluid mixture that is suitable for conduct of alpha spectroscopy with a centrifugally tensioned metastable fluid detector (CTMFD). The resulting α-TMFD technology was compared against the state-of-art “Alpha-Sentry™” Continuous Air Monitor (CAM) system commonly utilized world-wide. Results indicate that the α-TMFD technology can potentially offer complementary and superior performance in multiple performance categories, and ∼18× improvement in the time to detect (e.g., at 0.02 derived air concentration (DAC) within ∼3 h, versus ∼70 h for Alpha-Sentry) for actinides of interest while also remaining ∼100% blind to ∼10 3 × higher Rn-progeny background—with the added potential for offering few keV scale energy resolution without resorting to peak shape fitting, versus ∼300–400 keV for existing CAM systems.
Identification and rejection of pile-up jets at high pseudorapidity with the ATLAS detector
N/A
Correction to: Identification and rejection of pile-up jets at high pseudorapidity with the ATLAS detector
Unfortunately, in the original version of this article the copyright holder was wrong in the HTML. The original article has been corrected.
Polyglycine Acts as a Rejection Signal for Protein Transport at the Chloroplast Envelope
Not Available
Refrigeration Playbook. Heat Reclaim; Optimizing Heat Rejection and Refrigeration Heat Reclaim for Supermarket Energy Conservation
The purpose of this playbook and accompanying spreadsheets is to generalize the detailed CBP analysis and to put tools in the hands of experienced refrigeration designers to evaluate multiple applications of refrigeration waste heat reclaim across the United States. Supermarkets with large portfolios of similar buildings can use these tools to assess the impact of large-scale implementation of heat reclaim systems. In addition, the playbook provides best practices for implementing heat reclaim systems to achieve the best long-term performance possible. It includes guidance on operations and maintenance as well as measurement and verification.
General Guidelines on Criteria for Adoption or Rejection of Evaluated Libraries and Data by the Nuclear Data Team
This memo contains general guidelines on what documentation and tools need to be in place as well as format and data testing requirements such that evaluated nuclear data sets or entire libraries can be adopted by the nuclear data team. Additional requirements beyond this memo might apply for specific nuclear data observables. These guidelines were established based on discussions between J.L. Conlin, M.G. Gray, A.P. McCartney, D. Neudecker, D.K. Parsons and M.C. White.
Transplant rejection and tolerance – advancing the field through integration of computational and experimental investigation
This Research Topic provides a venue for stimulating these interdisciplinary conversations in the context of transplantation. The articles collected under this Research Topic introduce new theoretical and experimental studies that describe novel techniques and methods for understanding the interactions between the immune response and transplants and for establishing more effective strategies of diagnosis and intervention that will promote transplant tolerance.
Cosmogenic Background Rejection at the ICARUS [Poster]
ICARUS is on the surface of Earth and is exposed to huge cosmic activity and is the focus for several physics analyses. In summary, the overburden is very effective in reducing the hadrons while fully eliminating the electromagnetic cosmic ray components. Exploiting the information from three sub detectors and benchmarking the method with data is in progress.
Cosmogenic Background Rejection at ICARUS [Poster]
Explore the source record for details and available documents.
Next Generation Fiber-Encapsulated Nanoscale Hybrid Materials for Direct Air Capture with Selective Water Rejection
Recently, NOHMs sorbents have been demonstrated to be highly stable and tunable for CO2 capture and have negligible vapor pressure, but their main drawbacks are high viscosity and high gas transfer limitation in their neat bulk phase. This project explored gas-assisted electrospinning processing coupled with promising encapsulation matrices such as Polymers with Intrinsic Microporosity (PIM-1) and polyacrylonitrile (PAN)/organopolysilizane (OPSZ) polymer/ceramic hybrid materials, which were demonstrated to be effective novel carriers for the active NOHMs sorbents. These encapsulation materials were evaluated by their thermal stability, hydrophobicity, permeability, and CO2 selectivity. The manufacturing parameters such as component composition and processing solvent were linked to bulk sorbent properties, e.g., surface area, pore volume, fiber thickness, capture capacity, capture kinetics, etc. These investigations resulted in fundamental knowledge and technical know-how that will be useful for scaling up the nanofiber mat contactor design. The encapsulation materials and design has been shown to not only increase the thermal oxidative stability of the NOHMs, but also yield significantly reduced pressure drop and increased performance of large modular air filters. 70 PAN: 30 OPSZ/NIPEI fibers exhibited the highest capture performance with 1.5 mmol CO2/g∙h kinetics the first hour under 100% CO2 condition, followed by 80 PAN: 20 OPSZ/NIPEI and 90 PAN: 10 OPSZ/NIPEI, while 90 PAN: 10 OPSZ/NIPEI fibers performed the best with 0.25 mmol CO2/g∙h of the initial kinetics under 400 ppm CO2 concentration. All the fabricated fibers demonstrated stable capture performances up to 15 cycles of adsorption and desorption. Using encapsulated NOHMs, the study found that the microwave could help regenerate the capture materials within 20 minutes without chemically degrading the materials. A high-level TEA/LCA study was performed to evaluate the feasibility of this technology at scale. These estimates show that the sorbent cost and environmental impact levels are comparable to other existing technologies. Overall, these findings increase the technological feasibility of using liquid-like, low vapor pressure NOHMs as a next generation sorbent for the direct air capture of CO2.
Deterministic Linear Time for Maximal Poisson-Disk Sampling using Chocks without Rejection or Approximation.
Abstract not provided.
Falling Particle Receiver Mass Flow Control for Dynamic Disturbance Rejection
Explore the source record for details and available documents.
CONDENSER HEAT REJECTION SYSTEMS
Explore the source record for details and available documents.
High-pass RF coaxial filter rejects dc and low frequency signals
A low-loss RF filter element for coaxial transmission provides dc isolation and eliminates low frequency signals. The characteristic impedance of the transmission line is not affected, as the design permits direct connection of the filter to the line.
Condenser heat rejection systems monthly progress report, 28 jan. - 24 feb. 1962
Large diameter jet condenser flow, temperature, and pressure instrumentation calibration
Condenser heat rejection systems monthly progress report, jan. 1962
Fabrication and testing of large diameter multiple tube jet condenser
Point-source detection system rejects spatially extended radiation sources
System employing digital space correlation to suppress false target signals in a point-target tracking device is a reliable method for discriminating a distant target from false targets in the field of view of an infrared detection system or tracking device.