Search NASA⌕ Search

SEARCH · Search NASA

Results for “Roofing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Solar water heater design package

Package describes commercial domestic-hot-water heater with roof or rack mounted solar collectors. System is adjustable to pre-existing gas or electric hot-water house units. Design package includes drawings, description of automatic control logic, evaluation measurements, possible design variations, list of materials and installation tools, and trouble-shooting guide and manual.

Source record↗

Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas

Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.

Source record↗

Winter performance of a domestic solar-heating system--Duffield, Virginia

Sunlight supplies 39 percent of heat load, saving 9 barrels of fuel oil in one heating season. Report describes system installation in two-story, single-family residence. Energy is collected with roof-mounted air flat-plate collectors, stored in rock bin, and transferred to water preheat tank whenever system is storing energy; heat pump supplies heat to house.

Source record↗

Motel solar-hot-water system--Dallas, Texas

Report describes system which meets 64 percent of hot water requirements of 120 room motel. Key system components include 1,000 square foot, roof-mounted collector array, 1,000 gallon storage tank, tube-in-shell heat exchanger, and three domestic hot-water tanks. Report contains calibration instructions for differential temperature controllers, shutdown procedures, and operation guidelines, performance analysis, and manufacturers' maintenance literature.

Source record↗

Motel solar-hot-water system with nonpressurized storage--Jacksonville, Florida

Modular roof-mounted copper-plated arrays collect solar energy; heated water drains from them into 1,000 gallon nonpressurized storage tank which supplies energy to existing pressurized motel hot water lines. System provides 65 percent of hot water demand. Report described systems parts and operation, maintenance, and performance and provides warranty information.

Source record↗

Building with integral solar-heat storage--Starkville, Mississippi

Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.

Source record↗

Solar heating and hot water system installed at Saint Louis, Missouri

The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

Source record↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

Urban solar photovoltaics potential: An inventory and modelling study applied to the San Fernando Valley region of Los Angeles

Procedures for analyzing the potential of solar photovoltaic collectors to meet energy requirements in a metropolitan region are described and a modeling effort is applied to the San Fernando Valley region of Los Angeles. The procedure involves a series of steps designed to produce maps and tabulations revealing the amount of rooftop area available for establishing solar collectors and the proportion of energy requirement that could be potentially supplied by solar photovoltaics within each of the 533 mainline feeder service areas in the study area. For the sixty five square mile study area, the results showed that, with half the available flat and south facing roofs used and assuming the availability of energy storage, 52.7 percent of the actual kWh energy requirements could have been met in 1978 using photovoltaic collectors. Hourly, daily, weekly, and monthly fluctuations in potential supply and actual loads and recommendations of avenues for further research are discussed. Some further potential applications of the modeling technique are suggested.

Angelici, G. L.↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Pyramidal-Reflector Solar Heater

Motor-driven reflector compensates for seasonal changes in Sun's altitude. System has flat-plate absorbers mounted on north side of attic interior. Skylight window on south-facing roof admits Sunlight into attic, lined with mirrors that reflect light to absorbers. Reflectors are inner surfaces of a pyramid lying on its side with window at its base and absorber plates in a cross-sectional plane near its apex.

Source record↗

Solar-Heated and Cooled Office Building--Columbus, Ohio

Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

Source record↗

Solar Hot Water for a Motor Inn -- Las Vegas, Nevada

Solar hot-water installation at motor inn in Las Vegas, Nevada is described in report containing descriptions of design, philosophy, operation of system and problems and solutions. Provides drawings of solar roof plan, operator's instructions, manufacturers' brochures and copy of acceptance report.

Source record↗

Two-Story-Dwelling Solar Installation

Report covers system description of a roof mounted solar energy system in Georgia. Includes study approach, economic analysis, results of analysis and economic uncertainty analysis. Elaboration on some of equations, procedures, and parameters used in analysis is found in report appendixes.

Source record↗

Pivot Attachment for Prefabricated Beams

Assembly of prefabricated structural beams for roof trusses, bleachers, or other lightweight structures made easier by use of flexural pivot at one or both ends. When pivot is attached, joint is flexible, thus simplifying alinement; joint is subsequently rigidized by threaded collar that completes attachment.

Stroll, H. W. J.↗

Solar hot water system installed at Mobile, Alabama

The system consists of six rows of ten collectors and three rows of eleven collectors (1990 square feet) mounted on the roof. Griswald flow control valves were installed to regulate the flow to each row. Two Heliotrope electronic thermometers with a combined capability of measuring the temperatures of 22 different locations were installed for monitoring purposes.

Source record↗

Solar hot water system installed at Las Vegas, Nevada

A solar energy hot water system installed in a motor inn at Las Vegas, Nevada is described. The inn is a three story building with a flat roof for installation of the solar panels. The system consists of 1,200 square feet of liquid flat plate collectors, a 2,500 gallon insulated vertical steel storage tank, two heat exchangers, and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

Source record↗

Integrated residential photovoltaic array development

The design details of an optimized integrated residential photovoltaic module/array are presented. This selected design features a waterproofing and mounting scheme which was devised to simplify the installation procedures by the avoidance of complex gasketed or caulked joints, while still maintaining a high confidence that the watertight integrity of the integral roofing surface will be achieved for the design lifetime of the system. The production and installation costs for the selected module/array design are reported for a range of annual production rates as a function of the cost of solar cells.

Shepard, N. F., Jr.↗