TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator Library

This website provides measured scintillation properties of many inorganic and organic materials and citations to published papers in which the original measurements were reported. It is intended for two main uses: a web-accessible reference to useful scintillation detector materials and properties; an aid in developing fundamental theories or empirical relations between basic material properties and scintillation performance. To this end, both strong and weak scintillators have been included as well as those where sensitive measurements have not detected any scintillation emissions.

Shook, L. [University of California, Berkeley, CA ↗

Investigation of the LiCaAlF 6 :Eu Scintillator Family for Next-Generation Neutron Detection (Annual Report)

LiCaAlF 6 :Eu (LiCAF:Eu) is a promising scintillator that possesses several fundamental advantages over CsLiYCl 6 :Ce (CLYC). This scintillator, however, is just one member of a much broader family of materials known as colquiriites, designated as LiMe II Me III F 6 , where Me II and Me III can be any number of divalent and trivalent cations, respectively. The LiCAF system has incredible potential for a wide variety of substitutions in the Me II and Me III sites, and its members are recognized as excellent hosts for luminescing activator dopants (e.g., Ce 3+ , Eu 2+ , Cr 3+ , Pb 2+ and Yb 2+ ) in order to tune the nuclear and luminescence performance in several ways. We intend to fully exploit this versatility by investigating the effects of substituting other alkali, alkali-earth, rare-earth, Group III, and Group XIII elements. The objective of this work is to explore the colquiriite system of scintillating materials, most notably LiCaAlF 6 :Eu, to identify and characterize new scintillators with improved scintillation performance, simplified crystal growth, and tunable neutron and gamma sensitivities.

Harrison, Mark J.↗

Accelerated Aging Test for Plastic Scintillator Gamma Ray Detectors

Polyvinyl toluene (PVT) and polystyrene (PS), collectively referred to as “plastic scintillator,” are synthetic polymer materials used to detect gamma radiation, and are commonly used in instrumentation. Recent studies have revealed that plastic scintillator undergoes an environmentally related material degradation that adversely affects performance under certain conditions and histories. A significant decrease in gamma ray sensitivity has been seen in some detectors in systems as they age. The degradation of sensitivity of plastic scintillator over time is due to a variety of factors, and the term “aging” is used to encompass all factors. Some plastic scintillator samples show no aging effects (no significant change in sensitivity over more than 10 years), while others show severe aging (significant change in sensitivity in less than 5 years). Aging effects arise from weather (variations in heat and humidity), chemical exposure, mechanical stress, light exposure, and loss of volatile components. The damage produced by these various causes can be cumulative, causing observable damage to increase over time. Damage may be reversible up to some point, but becomes permanent under some conditions. It has been demonstrated that exposure of plastic scintillator in an environmental chamber to 30 days of high temperature and humidity (90% relative humidity and 55°C) followed by a single cycle to cold temperature (-30°C) will produce severe fogging in all PVT samples. This thermal cycle will be referred to as the “Accelerated Aging Test.” This document describes the procedure for performing this Accelerated Aging Test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed Material Scintillator Systems Particle ID Modelling Report

AMixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators. This report contains results from this project’s second task, to model and quantify the promise of the MMSSs invented earlier in the project. Those inventions have been divided into two categories, and this report focuses on the first category: MMSS inventions the use zones of differently-colored scintillators to detect and characterize neutron sources. We call this category particle-ID, or PID, detectors. Inventions using gradients designed to encode the position of radiation interactions using gradients will be discussed in a future report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent development in organic scintillators

Discussion on recent developments of organic scintillators includes studies of organic compounds that form glass-like masses which scintillate and are stable at room temperature, correlations between molecular structure of organic scintillators and self-quenching, recently developed fast scintillators, and applications of liquid-scintillation counters.

Horrocks, D. L.↗

High latitude scintillation effects on very high frequency /vhf/ and S-band satellite transmissions.

A scintillation study was conducted with the purpose to define the extent of scintillation activity in the S-band region, and to determine if such activities at higher frequencies are caused by ionospheric irregularities similar to those causing scintillations at vhf and lower frequencies. Simultaneous transmissions at 137 and 1695 MHz from polar orbiting satellites were used in this study. Scintillations were found to be present at S-band frequencies in the polar regions; it is concluded that they are caused by ionospheric characteristics similar to those causing scintillations at lower frequencies.

Pope, J. H.↗

Research Investigation on Dense Scintillation Glass for Use in Total Absorption Nuclear Cascade Detectors

Three approaches to the development of a high density scintillation glass were investigated: They include the increase of density of glass systems containing cerium - the only systems which were known to show scintillation, the testing of a novel silicate glass system containing significant concentrations of silver produced by ion exchange and never tested previously, and the hot pressing of a diphasic compact of low density scintillation glass with high density passive glass. In first two cases, while ultraviolet excited fluorescence was maintained in the glasses showing high density, scintillation response to high energy particles was not retained in the case of the cerium containing glasses or developed in the case of the silver containing glasses. In the case of the compacts, the extremely long path length caused by the multiple internal reflections which occur in such a body resulted in attenuation even with glasses of high specific transmission. It is not clear why the scintillation efficiency is not maintained in the higher density cerium containing glasses.

Hensler, J. R.↗

Ionospheric irregularities causing scintillation of GHz frequency radio signals

Consideration of the recently observed phenomenon of scintillation of satellite signals at GHz frequency range. Based on the scintillation data and results from in situ measurements, several ionospheric irregularity models with different power spectra are studied. Scintillation index is computed for the various models and compared with observed results. Both magnitude and frequency dependence of the scintillation index are investigated. It is found that a thick irregularity slab of the order of 200 km with an electron density fluctuation of about 20 per cent of its background value and with a nonmonotonic power spectrum may account for the maximum observed values of the scintillation index as well as its frequency dependence. Some future observations and measurements are suggested.

Wernik, A. W.↗

Interstellar scattering of pulsar radiation. 1: Scintillation

An investigation of the intensity fluctuations of 28 pulsars near 0.4 GHz indicates that scintillation spectra have a Gaussian shape, scintillation indices are near unity, and the scintillation bandwidth depends linearly on dispersion measure. Observations near 2.5 GHz suggest a strong dependence of the frequency at which scintillation indices fall below unity on dispersion measure. Multistation measurements of scintillation provide values or limits for the scale size of the scattering diffraction pattern. The dependences of scattering parameters on dispersion measure is discussed in terms of the current models. It is suggested that any line of sight through the galaxy encounters increasingly rare, increasingly large deviations of thermal electron density on the scale of 10 to the 11th power cm.

Backer, D. C.↗

Ionospheric scintillations associated with equatorial E-region

Amplitude scintillations at 40, 140, and 360 MHz recorded at an equatorial station Ootacamund (dip 4 deg N) during the ATS-6 phase II and the ionograms at a nearby station Kodaikanal (dip 3.5 deg N) are examined for the scintillation activity. Various sporadic E events, but not the Es-q, are associated with intense daytime scintillations. There are no scintillations at times of normal E-layer or cusp type of Es. Scintillations are also present at times of night Es.

Chandra, H.↗

Equatorial scintillations - A review

Scintillation observations of equatorial irregularities by techniques such as in situ, radar backscatter, airglow, and total electron content are reviewed, with an emphasis on GHz measurements. New aspects of the spread-F analysis from ionograms are mentioned, followed by a discussion of scintillation morphology, and the longitudinal control of the equatorial scintillations is emphasized. A coordinated multitechnique observation of the equatorial irregularities is described in detail, the study being divided into two parts: (1) an examination of the large field-aligned irregularity structures and their association with discrete patches of scintillation activity, and (2) an investigation of the coexistence of km-scale-irregularities with meter scales and a description of the evolution of the irregularity and scintillation spectra during the various phases of irregularity generation and decay. Unsolved problems are also reviewed, e.g., it is stated that the effects of steep spatial gradients in the electron density structures and their subsequent erosion on both CW and pulse propagation need to be evaluated both from the point of view of theory and experiments.

Basu, S.↗

High pressure gas scintillation drift chambers with wave shifter fiber readout. I

The authors present results from a prototype xenon-gas scintillation drift chamber. It was operated at pressures up to 20 atm, and the scintillation light yield was measured at various pressures and reduced fields. Scintillation-reduced fields ranged from 1.3 to 3 kV/cm/atm in a 5.4-mm scintillation gap. Drift fields ranged from 45 to 100 V/cm/atm in an 8-cm drift region. The chamber was exposed to an 241Am source in a port either 2.7 or 5.4 cm from the secondary scintillation region. The authors also describe the high-voltage problems encountered during operation at high pressures. Further tests with the wave shifter fiber readout showed that the problem of gas contamination by the fibers is manageable but that the interaction between the optical fibers and the high-pressure xenon gas can lead to fiber damage. A solution to this problem is described.

Parsons, A.↗

Results from a study of scintillation behavior at 12, 20, and 30 GHz using the results from the Virginia Tech Olympus receivers

Tropospheric scintillations are rapid fluctuations of signal caused by multiple scattering from the small scale turbulent refractive index inhomogeneities in the troposphere. They can strongly impair satellite communications links operating at frequency above 10 GHz. The VA Tech OLYMPUS propagation experiment which includes 12, 20, and 30 GHz beacon receivers at an elevation angle of 14 degrees provides us with valuable multifrequency scintillation data. A long term analysis of tropospheric scintillation results from the VA Tech OLYMPUS experiment is presented. It includes statistics of both the scintillation intensity and the attenuation relative to clear air as well as seasonal, diurnal and meteorological trends. A comparison with the Consultative Committee for International Radio (CCIR) predictive model for scintillation fading is presented.

Pratt, Timothy↗

Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy

New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.

Bloser, Peter F.↗

Tests of Multibeam Scintillation Mitigation on Laser Uplinks

A report presents additional details about parts of the program of research and development that is the topic of the immediately preceding article. The report emphasizes those aspects of the program that pertain to the use of multiple uplink laser beams in a ground-to-spacecraft optical communication system to reduce (relative to the case of a single uplink laser beam) the depth and frequency of occurrence of fades in the uplink signal received at the spacecraft. The underlying multibeam scintillation-mitigation concept was described in "Multiple-Beam Transmission for Optical Communication" (NPO-20384), NASA Tech Briefs, Vol. 22, No. 11 (November 1998), page 56. The report discusses the need for mitigating uplink scintillation; briefly describes the Optical Communications Telescope Laboratory and its role as the ground station in the research; summarizes prior experiments in uplink scintillation and multibeam mitigation of scintillation in ground-to-spacecraft laser communications; and describes key experiments planned to be performed in the next five years. The report then elaborates somewhat on the initial experiments, which are to be dedicated to understanding and perfecting the multibeam scintillation-mitigation strategy.

Wilson, Keith↗

Studies of non-proportionality in alkali halide and strontium iodide scintillators using SLYNCI

Recently a collaboration of LLNL and LBNL has constructed a second generation Compton coincidence instrument to study the non-proportionality of scintillators. This device, known as SLYNCI (Scintillator Light-Yield Non-proportionality Characterization Instrument), has can completely characterize a sample with less than 24 hours of running time. Thus, SLYNCI enables a number of systematic studies of scintillators since many samples can be processed in a reasonable length of time. These studies include differences in nonproportionality between different types of scintillators, different members of the same family of scintillators, and impact of different doping levels. The results of such recent studies are presented here, including a study of various alkali halides, and the impact of europium doping level in strontium iodide. Directions of future work area also discussed.

59 BASIC BIOLOGICAL SCIENCES↗