W-Band Scanning ARM Cloud Radar (WSACR) Multiple Elevation PPI Scan (a1-level)

The wsacr PCM process executed by the sacr3 binary reads in wsacr.00 data and produces CF/Radial compliant NetCDF files for each of the radar operational scanning modes. This incorporates raw data from the radar, as well as scientifically important base derived parameters that affect interpretation of the data.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of CO in Mesoporous Silica Monitored by Time ResolvedStep-Scan and Rapid-Scan FT-IR Spectroscopy

Carbon monoxide molecules generated in the channels ofmesoporous MCM-41 silica sieve from a precursor (diphenyl cyclopropenone)by photodissociation with a nanosecond laser pulse were monitored by timeresolved FT-infrared spectroscopy using the step-scan and rapid-scanmethods. A very broad absorption of CO is observed in the region 2200 to2080 cm-1 at room temperature that decays in a biphasic mode. Two-thirdsof the band intensity decays on the hundreds of microsecond scale(lifetime 344 + 70 ?s). The process represents the escape of themolecules through the mesopores into the surrounding gas phase, and adiffusion constant of 1.5 x 10-9 m2/sec is derived. The broad profile ofthe absorption is attributed to contact of the random hopping CO withsiloxaneand silanol groups of the pore surface. Measurements usingMCM-41 with the silanols partially capped by trimethyl silyl groups gavefurther insight into the nature of the infrared band profile. These arethe first observations on the diffusion behavior of carbon monoxide in amesoporous material at room temperature. The residual carbon monoxideremains much longer in the pores and features distinct peaks at 2167 and2105 cm-1 characteristic for CO adsorbed on SiOH groups C end on and Oend on, respectively. The bands decrease with time constants of 113 + 3ms (2167 cm-1) and 155 + 15 ms (2105 cm-1) suggesting that CO in thesesites is additionally trapped by surrounding diphenyl acetyleneco-product and/or precursor molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Directed flow of quarks from the RHIC Beam Energy Scan measured by STAR

Directed flow (ν 1 ) is a good probe of the early-stage dynamics of collision systems, and the ν 1 slope at midrapidity ( dv 1 /dy| y=0 ) is sensitive to the system's equation of state. STAR has published ν 1 (y) measurements for ten particle species (π ± ,$p, \bar{p},Λ,\bar{Λ},ϕ,K^± and K_S^0$) in Au+Au collisions at eight beam energies from $ \sqrt{s_{NN}}$ = 7.7 GeV to 200 GeV. In this study, we employ a simple coalescence idea to decompose ν 1 of hadrons into ν 1 of constituent quarks. The dv 1 /dy values of $\bar{p},\bar{K},$ and $\bar{Λ}$ are used to test the coalescence sum rule for produced quarks. Data involving produced quarks support the coalescence picture at $ \sqrt{s_{NN}}$ =11.5 GeV to 200 GeV, and a sharp deviation from this picture is observed at 7.7 GeV. The dv 1 /dy of transported quarks is studied via net particles (net p and net Λ). In these proceedings, we further extract the ν 1 slopes of produced and transported quarks, assuming that the coalescence sum rule is valid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metal hydride differential scanning calorimetry as an approach to compositional determination of mixtures of hydrogen isotopologues and helium

Gaseous mixtures of diatomic hydrogen isotopologues and helium are often encountered in the nuclear energy industry and in analytical chemistry. Compositions of stored mixtures can vary due to interactions with storage and handling materials. When tritium is present, it decays to form ions and helium-3, both of which can lead to further compositional variation. Monitoring of composition is typically achieved by mass spectrometry, a method that is bulky and energy-intensive. Mass spectrometers disperse sample material through vacuum pumps, which is especially troublesome if tritium is present. Moreover, our ultimate goal is to create a compact, fast, low-power sensor that can determine composition with minimal gas consumption and waste generation, as a complement to mass spectrometry that can be instantiated more widely. We propose calorimetry of metal hydrides as an approach to this, due to the strong isotope effect on gas absorption, and demonstrate the sensitivity of measured heat flow to atomic composition of the gas. Peak shifts are discernible when mole fractions change by at least 1%. A mass flow restriction results in a unique dependence of the measurement on helium concentration. We present a mathematical model as a first step toward prediction of the peak shapes and positions. The model includes a useful method to compute estimates of phase diagrams for palladium in the presence of arbitrary mixtures of hydrogen isotopologues. As a result, we expect that this approach can be used to deduce unknown atomic compositions from measured calorimetric data over a useful range of partial pressures of each component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New method for analysis of X-ray computed tomography scans of TRISO fuel forms

X-ray computed tomography (XCT) is a powerful characterization tool that has been used for examination of both tristructural-isotropic (TRISO) coated particles and fuel forms. Rapid, nondestructive imaging of complete specimens by XCT provides significant characterization advantages in both speed and comprehensiveness over traditional materialographic methods. This paper discusses a method that has been developed to analyze XCT images of pebble fuel forms containing ~18,000 TRISO particles each. The XCT images are three-dimensional with contrast based on relative x-ray transparency. In the case of TRISO fuel forms, XCT image intensity distinguishes between the high-density kernel, the medium-density SiC, and the low-density matrix and carbon layers. Image analysis software has been developed to process XCT data sets to extract spatial distribution information, including particle nearest-neighbor distances, local packing fraction, and fuel-free zone thickness in TRISO fuel forms. Finally, although this type of high-resolution XCT analysis is likely not feasible as a quality control measurement for commercial TRISO fuel, it is highly useful in generating feedback for the development of fuel form fabrication processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗