Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Toward broad-band x-ray detected ferromagnetic resonance in longitudinal geometry

An ultrahigh-vacuum-compatible setup for broad-band X-ray detected ferromagnetic resonance (XFMR) in longitudinal geometry is introduced which relies on a low-power, continuous-wave excitation of the ferromagnetic sample. A simultaneous detection of the conventional ferromagnetic resonance via measuring the reflected microwave power and the XFMR signal of the X-ray absorption is possible. First experiments on the Fe and Co L{sub 3}-edges of a permalloy film covered with Co nanostripes as well as the Fe and Ni K-edges of a permalloy film are presented and discussed. Two different XFMR signals are found, one of which is independent of the photon energy and therefore does not provide element-selective information. The other much weaker signal is element-selective, and the dynamic magnetic properties could be detected for Fe and Co separately. The dependence of the latter XFMR signal on the photon helicity of the synchrotron light is found to be distinct from the usual x-ray magnetic circular dichroism effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient reflectance of photoexcited Cd{sub 3}As{sub 2}

We report ultrafast transient-grating measurements of crystals of the three-dimensional Dirac semimetal cadmium arsenide, Cd{sub 3}As{sub 2}, at both room temperature and 80 K. After photoexcitation with 1.5-eV photons, charge-carriers relax by two processes, one of duration 500 fs and the other of duration 3.1 ps. By measuring the complex phase of the change in reflectance, we determine that the faster signal corresponds to a decrease in absorption, and the slower signal to a decrease in the light's phase velocity, at the probe energy. We attribute these signals to electrons' filling of phase space, first near the photon energy and later at lower energy. We attribute their decay to cooling by rapid emission of optical phonons, then slower emission of acoustic phonons. We also present evidence that both the electrons and the lattice are strongly heated.

36 MATERIALS SCIENCE↗

Theoretical study of optical dielectric response of ZnO nanostructure film deposited on silica substrate using Maxwell-Garnett effective medium theory

In the present study the dielectric optical response of various nanostructures of ZnO deposited on silica substrate has been studied using Maxwell-Garnett Effective Medium Theory. Using the volume filling factors for different nanostructures of ZnO the effective dielectric constant has been evaluated. The variation of this effective dielectric constant with the frequency of applied signal has been investigated. Moreover, the reflectance of the film, power absorption and variation of refractive index with frequency has been studied. The results obtained show that the quantum confinement effects in ZnO nano-structural films deposited on silica substrate give rise to distinct optical properties making it an ideal choice for high power THz generation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Demonstration of an x-ray Raman spectroscopy setup to study warm dense carbon at the high energy density instrument of European XFEL

We present a proof-of-principle study demonstrating x-ray Raman Spectroscopy (XRS) from carbon samples at ambient conditions in conjunction with other common diagnostics to study warm dense matter, performed at the high energy density scientific instrument of the European x-ray Free Electron Laser (European XFEL). We obtain sufficient spectral resolution to identify the local structure and chemical bonding of diamond and graphite samples, using highly annealed pyrolytic graphite spectrometers. Due to the high crystal reflectivity and XFEL brightness, we obtain signal strengths that will enable accurate XRS measurements in upcoming pump–probe experiments with a high repetition-rate, where the samples will be pumped with high-power lasers. Molecular dynamics simulations based on density functional theory together with XRS simulations demonstrate the potential of this technique and show predictions for high-energy-density conditions. Our setup allows simultaneous implementation of several different diagnostic methods to reduce ambiguities in the analysis of the experimental results, which, for warm dense matter, often relies on simplifying model assumptions. The promising capabilities demonstrated here provide unprecedented insights into chemical and structural dynamics in warm dense matter states of light elements, including conditions similar to the interiors of planets, low-mass stars, and other celestial bodies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TRANSITS AND OCCULTATIONS OF AN EARTH-SIZED PLANET IN AN 8.5 hr ORBIT

We report the discovery of an Earth-sized planet (1.16 {+-} 0.19 R{sub Circled-Plus }) in an 8.5 hr orbit around a late G-type star (KIC 8435766, Kepler-xx). The object was identified in a search for short-period planets in the Kepler database and confirmed to be a transiting planet (as opposed to an eclipsing stellar system) through the absence of ellipsoidal light variations or substantial radial-velocity variations. The unusually short orbital period and the relative brightness of the host star (m{sub Kep} = 11.5) enable robust detections of the changing illumination of the visible hemisphere of the planet, as well as the occultations of the planet by the star. We interpret these signals as representing a combination of reflected and reprocessed light, with the highest planet dayside temperature in the range of 2300 K-3100 K. Follow-up spectroscopy combined with finer sampling photometric observations will further pin down the system parameters and may even yield the mass of the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Subdiffraction instrumentation development and application to the elucidation of biological systems, thin films, and organic photovoltaic devices

Fluorescence and Raman instrumentation was developed to elucidate morphology, information on local environment, and material properties of target systems. Far-field fluorescence and luminescence spectroscopic measurements were performed using a pulsed super-continuum laser source and detector with high temporal resolution. With this arrangement morphologies of structures were coupled with time-correlated data. Polymeric beads and Alexa Fluor 594-phalloidin labeled cellular actin structures of cultured cells were imaged below the diffraction limit using stimulated emission depletion to resolve structures to ≈40nm. Lifetime imaging revealed a 2.0 ± 0.1 ns lifetime for fluorescently-labeled beads in confocal and depletion imaging modes. Depletion imaging was also able to display a change of 2.2 to 2.9 ns for different regions of the cellular actin network of cultured cells with a possible difference in lifetime caused by tryptophan quenching of the dye. Subdiffraction imaging with a resolution of ≈40 nm was also accomplished using luminescence depletion of photostable giant CdSe/14CdS nanocrystal quantum dots in air. Nanocrystal quantum dots, typically not prone to depletion, exhibited this phenomenon when excited with an energy of 50 pJ and 2 nJ of depletion energy. Luminescence depletion required half the energy compared to stimulated emission depletion to achieve the same resolution limit. The luminescence was depleted by as much as ≈92% with no observable photobleaching. Raman measurements of polymer films were performed with 532-nm laser illumination using scanning angle and conventional 180° backscattering modes to determine chemical information. The scanning angle mode achieved an angle resolution of 0.09° and was used to probe a thin layer of polystyrene as well as a diblock copolymer of polystyrene and poly(3-hexylthiophene-2,5-diyl). Enhancements to the Raman signals at selected angles lower than the critical angle for total internal reflection, characteristic of waveguides, were measured. An additional enhancement in the Raman signal results from resonant conditions for the diblock copolymer. The epi-collection geometry was used to gain spectroscopic information regarding to the stability of heterojunction solar cells with the aid of resonance Raman spectroscopy. Raman spectral characteristics corresponding to thiophene-based functional groups were used to relate stability of the polymers under different processing conditions such as solvent and thermal annealing while undergoing laser induced photodegradation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

CSAPR2 cell-tracking data collected during TRACER

One of the challenges of analyzing convective cell properties is quick evolution of the individual convective cells. While the operational radar data provide great a data set to analyze the evolution of radar observables of convective precipitation clouds statistically, previous studies also suggested that, because of the quick evolution of cell life cycle, conventional radar volume scan strategies taking ~5-7 minutes might not capture the detailed evolution. The TRACER campaign deployed CSAPR2, which performed frequent update of RHI and sector PPI scans to track convective cells every < 2 minutes guided by a new cell-tracking framework, Multisensor Agile Adaptive Sampling (MAAS; Kollias et al. 2020). This allows for capturing fast-evolving radar observables. The submitted data files are CSAPR2 data in CfRadial format collected during the TRACER field campaign from June to September 2020. The data files include processed radar variables including: noise-masked reflectivity and differential reflectivity corrected for rain attenuation and systematic biases, noise-masked dealiased radial velocity, specific differential phase, locations of target cells (latitude, longitude, radar range), and radar-echo classification.

54 ENVIRONMENTAL SCIENCES↗

Method and system for generating a beam of acoustic energy from a borehole, and applications thereof

A compact array of transducers is employed as a downhole instrument for acoustic investigation of the surrounding rock formation. The array is operable to generate simultaneously a first acoustic beam signal at a first frequency and a second acoustic beam signal at a second frequency different than the first frequency. These two signals can be oriented through an azimuthal rotation of the array and an inclination rotation using control of the relative phases of the signals from the transmitter elements or electromechanical linkage. Due to the non-linearity of the formation, the first and the second acoustic beam signal mix into the rock formation where they combine into a collimated third signal that propagates in the formation along the same direction than the first and second signals and has a frequency equal to the difference of the first and the second acoustic signals. The third signal is received either within the same borehole, after reflection, or another borehole, after transmission, and analyzed to determine information about rock formation. Recording of the third signal generated along several azimuthal and inclination directions also provides 3D images of the formation, information about 3D distribution of rock formation and fluid properties and an indication of the dynamic acoustic non-linearity of the formation.

47 OTHER INSTRUMENTATION↗

WISE/NEOWISE OBSERVATIONS OF COMET 103P/HARTLEY 2

We report results based on mid-infrared photometry of comet 103P/Hartley 2 taken during 2010 May 4-13 (when the comet was at a heliocentric distance of 2.3 AU, and an observer distance of 2.0 AU) by the Wide-field Infrared Survey Explorer. Photometry of the coma at 22 {mu}m and data from the University of Hawaii 2.2 m telescope obtained on 2010 May 22 provide constraints on the dust particle size distribution, d log n/d log m, yielding power-law slope values of alpha = -0.97 {+-} 0.10, steeper than that found for the inbound particle fluence during the Stardust encounter of comet 81P/Wild 2. The extracted nucleus signal at 12 {mu}m is consistent with a body of average spherical radius of 0.6 {+-} 0.2 km (one standard deviation), assuming a beaming parameter of 1.2. The 4.6 {mu}m band signal in excess of dust and nucleus reflected and thermal contributions may be attributed to carbon monoxide or carbon dioxide emission lines and provides limits and estimates of species production. Derived carbon dioxide coma production rates are 3.5({+-} 0.9) x 10{sup 24} molecules per second. Analyses of the trail signal present in the stacked image with an effective exposure time of 158.4 s yields optical-depth values near 9 x 10{sup -10} at a delta mean anomaly of 0.2 deg trailing the comet nucleus, in both 12 and 22 {mu}m bands. A minimum chi-squared analysis of the dust trail position yields a beta-parameter value of 1.0 x 10{sup -4}, consistent with a derived mean trail-grain diameter of 1.1/{rho} cm for grains of {rho} g cm{sup -3} density. This leads to a total detected trail mass of at least 4 x 10{sup 10} {rho} kg.

79 ASTRONOMY AND ASTROPHYSICS↗

Cadmium and cellular signaling cascades: To be or not to be?

The cellular effects of the toxic metal cadmium (Cd) are manifold. A large proportion of the cellular reactions affected by ionic Cd{sup 2+} are mediated by cellular signaling cascades. The aim of this review is to provide a principal understanding of the known physiological signaling cascades, which are recruited by Cd{sup 2+}, and to highlight the fact that Cd{sup 2+}, similarly to other toxic metals, disrupts physiological signal transduction. In principle, second messengers are generated at the time of receptor activation, are short-lived, and act specifically in space and time through non-covalent binding on effectors to transiently alter their activity. Signaling dysregulation induced by Cd{sup 2+} is reflected by a permanent disruption of transducing modules, resulting in low and/or elevated and constant levels of second messengers, which overwhelm the control mechanisms of signaling. This disturbs physiological cellular functions, gene transcription and regulation and may result in cell death and/or stress-induced adaptation and survival as well as carcinogenesis. The impact of Cd{sup 2+} on Ca{sup 2+}-, cAMP-, NO-, ROS-, MAP-kinase-, PKB/Akt-, nuclear factor-kappa B-, and developmental signaling is critically discussed. The hierarchical as well as cooperative and integrative character of signaling cascades activated by Cd{sup 2+} is illustrated in the kidney proximal tubule, a major target of Cd{sup 2+} toxicity. This review also aspires to pinpoint new avenues of research that may contribute to a more differentiated view of the complex mechanisms underlying Cd{sup 2+} toxicity in target tissues and eventually lead to rationales and strategies for prevention and therapy of Cd{sup 2+} toxicity.

60 APPLIED LIFE SCIENCES↗

Method of evaluating pH using an inorganic-oxide nanoparticle based optical pH sensor

A method for evaluating the pH of an aqueous solution by utilizing the optical properties of a pH sensing material includes optically active nanoparticles fixed to a substrate. The optically active nanoparticles have a localized refractive index modulation over a pH range from 2.0 to 12.0 of at least 1% and, where the plurality of optically active nanoparticles have an average nanoparticle diameter of less than about 500 nanometers. The method includes contacting the pH sensing material with the aqueous solution, illuminating the pH sensing material, and monitoring an optical signal generated through comparison of incident light and exiting light to determine the optical transmission, absorption, reflection, and/or scattering of the pH sensitive material. The optical signal of the pH sensitive material varies in response to the pH of the aqueous solution, providing a means by which the pH and any changes in the pH may be analyzed.

02 PETROLEUM↗

Method of evaluating pH using a metallic nanoparticle incorporated nanocomposite-based optical pH sensor

A method for evaluating the pH of an aqueous solution by utilizing the optical properties of a pH sensing material comprised of plurality of optically active nanoparticles dispersed in matrix material. The optically active nanoparticles have an electronic conductivity greater than about 10−1 S/cm and generally have an average nanoparticle diameter of less that about 500 nanometers, and the matrix material is a material which experiences a change in surface charge density over a pH range from 2.0 to 12.0 of at least 1%. The method comprises contacting the pH sensing material and the aqueous solution, illuminating the pH sensing material, and monitoring an optical signal generated through comparison of incident light and exiting light to determine the optical transmission, absorption, reflection, and/or scattering of the pH sensitive material. The optical signal of the pH sensitive material varies in response to the pH of the aqueous solution.

Ohodnicki, Jr., Paul R.↗

Quantum noise of a Michelson-Sagnac interferometer with a translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes ({approx_equal}100 ng) with high mechanical Q values at room temperature ({>=}10{sup 6}) have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity (<0.4 at a wavelength of 1064 nm) which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this topology, both power and signal recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°–10° to 1°–2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband anti-reflective coatings for cosmic microwave background experiments

The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to ~700 mm diameter) and lenslets (~5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetra uoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and applications of retro-reflective surfaces for ultrasound in LBE

The Belgian Nuclear Research Centre SCK-CEN is in the process of developing MYRRHA - a fast flux research reactor to replace the aging BR2. MYRRHA is conceptualized as an accelerator driven system cooled by lead bismuth eutectic mixture (LBE). As LBE is opaque to visual light, ultrasonic measurement techniques are employed as the main technology to provide feedback to submerged operations when needed. Conceptually, MYRRHA is a pool type reactor divided in a cold lower plenum and hot upper plenum separated by a diaphragm that forces the main flow through the core. The main flow is cooled by four heat exchangers and driven by two liquid metal pumps. One of the tasks tackled using ultrasound is locating a potentially lost fuel assembly to assist a recovery operation. As all fuel manipulations in MYRRHA are performed in the lower plenum, a potentially lost fuel assembly is located in the lower plenum. Buoyancy will force the lost fuel assembly to float against the diaphragm unless it is still partially inserted in the core. Because of the latter situation, an ultrasonic scan localizing the fuel assembly should be performed from a large distance to avoid a collision with such a partially inserted fuel assembly. Unfortunately, standard machined stainless steel objects, such as a fuel assembly, reflect an ultrasonic pulse in a specular way which induces stringent requirements on the alignment of the ultrasonic sensor with respect to the fuel assembly as we cannot rely on diffuse reflections and/or scattering of the ultrasonic pulse. Moreover, increasing the distance also increases geometric spreading and absorption of the pulse weakening the signal amplitude even faster to noise levels when deviating from perfect alignment. An alternative approach consists in relying on reflections from the known surroundings: a lost fuel assembly will block the line-of-sight to the diaphragm resulting in an anomaly in the reflection - either a shorter than expected time-of-flight of the pulse or a complete absence of a reflection like a shadow. In that way, it suffices to align the sensor with the diaphragm instead of the fuel assembly which is much easier to achieve as the robotics on which the sensor is mounted move parallel with the diaphragm. The alignment requirement in the latter approach can be further relaxed by using a tiling of retro-reflectors on the lower surface of the diaphragm. In that way, alignment becomes less vital and the main source of acoustic energy loss - geometric spread of the beam - is almost completely removed, leaving only absorption losses. In this paper, we present the first results in developing a retro reflectance surface for ultrasound in LBE. We present experimental results for different designs of retro-reflectors in both water and LBE. We discuss both linear and array retro-reflectors of different sizes and investigate the influence of the main relevant ultrasonic parameters such as wavelength and spot size on the strength of the received reflection under different alignment angles. We also demonstrate how retro-reflective surfaces can be exploited when localizing objects using linear and rotating scanning methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗