Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILICON RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Charge-coupled device (CCD) television camera for NASA's Galileo mission to Jupiter

The CCD detector under construction for use in the slow-scan television camera for the NASA Galileo Jupiter orbiter to be launched in 1985 is presented. The science objectives and the design constraints imposed by the earth telemetry link, platform residual motion, and the Jovian radiation environment are discussed. Camera optics are inherited from Voyager; filter wavelengths are chosen to enable discrimination of Galilean-satellite surface chemical composition. The CCO design, an 800 by 800-element 'virtual-phase' solid-state silicon image-sensor array with supporting electronics, is described with detailed discussion of the thermally generated dark current, quantum efficiency, signal-to-noise ratio, and resolution. Tests of the effect of ionizing radiation were performed and are analyzed statistically. An imaging mode using a 2-1/3-sec frame time and on-chip summation of the signal in 2 x 2 blocks of adjacent pixels is designed to limit the effects of the most extreme Jovian radiation. Smearing due to spacecraft/target relative velocity and platform instability will be corrected for via an algorithm maximizing spacial resolution at a given signal-to-noise level. The camera is expected to produce 40,000 images of Jupiter and its satellites during the 20-month mission.

Klaasen, K. P.↗

Eye-safe visible wavelength lidar

Recent technological advances on several fronts offer the possibility for relatively low-cost, eye-safe visible-wavelength lidar systems for autonomous aerosol/environmental monitoring applications. Improved silicon photodiodes and avalanche photodiodes that have become available offer high-quantum-efficiency detection at very low dark counts (10 to 1000 count/s) and can be used in a photon counting mode for signal plus background and dark current photoelectron count rates of megahertz. The essential requirements and features of a possible lidar system that capitalizes on technical advances on several fronts are outlined. A baseline lidar system is suggested for monitoring tropospheric and stratospheric aerosols. Sensitivity to wavelength, background radiation, detector characteristics, and other system parameters is discussed for several simulated data sets.

Cooley, T. W.↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Effects of Low Earth Orbit on Docking Seal Materials

Spacecraft docking seals are typically made of silicone elastomers. When such seals are exposed to low Earth orbit (LEO) conditions, they can suffer damage from ultraviolet (UV) radiation and atomic oxygen (AO, or monoatomic oxygen, the predominant oxygen species in LEO). An experiment flew on the International Space Station (ISS) to measure the effects of LEO on seal materials S0383-70 and ELA-SA-401 and various mating counterface materials which included anodized aluminum. Samples flown in different orientations received different amounts of UV and AO. The hypotheses were that most of the damage would be from UV, and 10 days or more of exposure in LEO would badly damage the seals. Eighteen seals were exposed for 543 days in ram (windward), zenith (away from Earth), or wake (leeward) orientations, and 15 control samples (not flown) provided undamaged baseline leakage. To determine post-flight leak rates, each of the 33 seals were placed in an O-ring groove of a leak test fixture and pressure tested over time. Resistance temperature detectors (RTDs), pressure transducers, and LabVIEW (National Instruments) programs were used to measure and analyze the temperature and pressure and calculate leakage. Average leakage of control samples was 2.6 x 10(exp -7) lbs/day. LEO exposure did not considerably damage ELA-SA-401. The S0383-70 flight samples leaked at least 10 times more than ELA-SA-401 in all cases except one, demonstrating that ELA-SA-401 may be a more suitable sealing material in LEO. AO caused greater damage than UV; samples in ram orientation (receiving an AO fluence of 4.3 x 10(exp 21) atoms/(sq cm) and in wake (2.9x 10(exp 20) atoms/(sq cm)) leaked more than those in zenith orientation (1.58 x 10(exp 20) atoms/(sq cm)), whereas variations in UV exposure did not seem to affect the samples. Exposure to LEO did less damage to the seals than hypothesized, and the data did not support the conjecture that UV causes more damage than AO.

Leakage↗

Design and performance of the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument

Design and performance data are analyzed for the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument, which has been developed for the NASA Earth Radiation Budget Satellite (ERBS). SAGE II is designed to monitor globally, from 70 degrees S to 70 degrees N latitude, the vertical distribution of stratospheric aerosols, ozone, water vapor, and nitrogen dioxide by measuring the extinction of solar radiation through the earth's atmosphere during the ERBS observatory solar occultations. A flat scanning mirror reflects solar radiation into a Cassegrain type telescope, which forms a solar image on the entrance slit of a grating spectrometer. The instantaneous-field-of-view of the SAGE II is scanned along the vertical solar diameter by the elevation scan mirror. The optical system is contained within an azimuth gimbal which tracks the solar radiometric centroid during the data event, while the spectrometer isolates seven spectral wavelengths from 0.385-1.02 micrometers. The seven channels of the spectrometer use silicon photodiode dedectors operated in the photovoltaic mode. The detector outputs are multiplexed into a serial data stream for readout by the ERBS telemetry system, with each output being sampled 64 times per second and digitized to 12 bit resolution.

Zaun, N. H.↗

Plasmonic photoconductive terahertz focal-plane array with pixel super-resolution

Abstract Imaging systems operating in the terahertz part of the electromagnetic spectrum are attractive due to their ability to penetrate many opaque materials and provide unique spectral signatures of various chemicals. However, the use of terahertz imagers in real-world applications has been limited by the slow speed, large size, high cost and complexity of present systems, largely due to the lack of suitable terahertz focal-plane array detectors. Here we report a terahertz focal-plane array that can directly provide the spatial amplitude and phase distributions, along with the ultrafast temporal and spectral information of an imaged object. It consists of a two-dimensional array of ~0.3 million plasmonic photoconductive nanoantennas optimized to rapidly detect broadband terahertz radiation with a high signal-to-noise ratio. We utilized the multispectral nature of the amplitude and phase data captured by these plasmonic nanoantennas to image different objects, including super-resolved etched patterns in a silicon substrate and defects in battery electrodes. By eliminating the need for raster scanning and spatial terahertz modulation, our terahertz focal-plane array offers more than a 1,000-fold increase in the imaging speed compared with the state of the art and potentially suits a broad range of applications in industrial inspection, security screening and medical diagnosis, among others.

Optics↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Considerations of Radiation-Hardened Electronics for Alpha Detectors in Molten Salt Reactors

Along with advanced generations of reactors quickly becoming reality, the need for instrumentation to provide reliable information for their safety and operation is also becoming relevant. Instrumentation-wise, molten salt reactors (MSRs) represent an especially challenging case in which detectors must survive extreme temperatures, high amounts of radiation, and a highly corrosive coolant. Adding to the complexity, tight material control and accounting must be maintained with any special nuclear material (SNM), a practice made more difficult by the nature of a loop of flowing fuel. Alpha spectroscopy offers a unique window into investigating the isotopic concentrations of actinides within just such a molten salt environment. The characteristic α emissions of specific actinide isotopes in the salt enable quantification of their concentrations. Semiconductor devices based on wide bandgap materials such as silicon carbide and gallium oxide can withstand the extreme temperatures within MSRs and offer good chemical stability with the corrosive salt. Collaborators at The Ohio State University are fabricating and testing a β gallium oxide α particle sensor that could identify actinide concentrations within the fuel salt to help improve the material control and accounting required for complicated system inherent to MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unusually Strong Near‐Infrared Photoluminescence of Highly Transparent Bulk InSe Flakes

Abstract Bulk γ‐InSe has a direct bandgap of 1.24 eV, which corresponds to near infrared wavelengths ( λ = 1.0 µm) useful in optoelectronic applications from biometric detectors to silicon photonics. However, its potential for optoelectronic applications is largely untapped due in part to the lack of quantitative studies of its optical properties. Here, the unusually low absorptance and high photoluminescence quantum efficiency of single‐crystalline InSe flakes with thickness in the hundreds of nanometers are studied. InSe emits brightly at room temperature from its direct bandgap with a peak photoluminescence quantum yield (PLQY) of 20%, despite displaying indirect bandgap like low absorption coefficient due to the symmetry of its crystal structure. By performing pump‐dependent PLQY measurements, the radiative and nonradiative recombination coefficients are extracted, including the Shockley‐Read‐Hall and Auger coefficients. Finally, a proof‐of‐concept alternating current electroluminescent device at low temperature is demonstrated to show the promise of InSe in optoelectronic technology such as highly transparent, bright NIR light sources.

Geng, Jamie↗

Integrated Electron-tunneling Refrigerator and TES Bolometer for Millimeter Wave Astronomy

We describe progress in the development of a close-packed array of bolometers intended for use in photometric applications at millimeter wavelengths from ground- based telescopes. Each bolometer in the may uses a proximity-effect Transition Edge Sensor (TES) sensing element and each will have integrated Normal-Insulator-Superconductor (NIS) refrigerators to cool the bolometer below the ambient bath temperature. The NIS refrigerators and acoustic-phonon-mode-isolated bolometers are fabricated on silicon. The radiation-absorbing element is mechanically suspended by four legs, whose dimensions are used to control and optimize the thermal conductance of the bolometer. Using the technology developed at NIST, we fabricate NIS refrigerators at the base of each of the suspension legs. The NIS refrigerators remove hot electrons by quantum-mechanical tunneling and are expected to cool the biased (approx.10 pW) bolometers to <170 mK while the bolometers are inside a pumped 3He-cooled cryostat operating at approx.280 mK. This significantly lower temperature at the bolometer allows the detectors to approach background-limited performance despite the simple cryogenic system.

Silverberg, R. F.↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

Design and Construction of the CMS Outer Tracker for the Phase-2 Upgrade

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000-4000~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about 5-7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger, for the first time at hadron colliders, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely spaced silicon sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments (stubs), used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), containing different sensor configurations and multiple ASICs. This contribution will present the design of the Phase-2 OT, the first results with pre-production devices, and the quality assurance procedures used to ensure the functionality of the modules: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication among the module's ASICs.

43 PARTICLE ACCELERATORS↗

Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III)

Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.

Flight Experiment↗

Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment.

Kim, Myung-Hee Y.↗