Search NASA⌕ Search

SEARCH · Search NASA

Results for “STIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose

Purpose: A new type of in vivo dosimeter, an optically stimulated luminescent dosimeter (OSLD), has now become commercially available for clinical use. The OSLD is a plastic disk infused with aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C). Crystals of Al{sub 2}O{sub 3}:C, when exposed to ionizing radiation, store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. The effects of accumulated dose on OSLD response were investigated. Methods: The OSLDs used in this work were nanodot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). Dose to the OSLDs was delivered by 6 MV x rays and gamma rays from Co-60 and Ir-192. The signal on the OSLDs after irradiation is removed by optical annealing with a 150 W tungsten-halogen lamp or a 14 W compact fluorescent lamp was investigated. Results: It was found that OSLD response to dose was supralinear and this response was altered with the amount of accumulated dose to the OSLD. The OSLD response can be modeled by a quadratic and an exponential equation. For accumulated doses up to 60 Gy, the OSLD sensitivity (counts/dose) decreases and the extent of supralinear increases. Above 60 Gy of accumulated dose the sensitivity increases and the extent of supralinearity decreases or reaches a plateau, depending on how the OSLDs were optically annealed. With preirradiation of OSLDs with greater than 1 kGy, it is found that the sensitivity reaches a plateau 2.5 folds greater than that of an OSLD with no accumulated dose and the supralinearity disappears. A regeneration of the luminescence signal in the dark after full optical annealing occurs with a half time of about two days. The extent of this regeneration signal depends on the amount of accumulated dose. Conclusions: For in vivo dosimetric measurements, a precision of {+-}0.5% can be achieved if the sensitivity and extent of supralinearity is established for each OSLD and use. Methods are presented for accomplishing this task.

36 MATERIALS SCIENCE↗

Accelerated sea-level rise is suppressing CO 2 stimulation of tidal marsh productivity: A 33-year study

Accelerating relative sea-level rise (RSLR) is threatening coastal wetlands. However, rising CO 2 concentrations may also stimulate carbon sequestration and vertical accretion, counterbalancing RSLR. A coastal wetland dominated by a C 3 plant species was exposed to ambient and elevated levels of CO 2 in situ from 1987 to 2019 during which time ambient CO 2 concentration increased 18% and sea level rose 23 cm. Plant production did not increase in response to gradually rising ambient CO 2 concentration during this period. Elevated CO 2 increased shoot production relative to ambient CO 2 for the first two decades, but from 2005 to 2019, elevated CO 2 stimulation of production was diminished. The decline coincided with increases in relative sea level above a threshold that hindered root productivity. While elevated CO 2 stimulation of elevation gain has the potential to moderate the negative impacts of RSLR on tidal wetland productivity, benefits for coastal wetland resilience will diminish in the long term as rates of RSLR accelerate.

54 ENVIRONMENTAL SCIENCES↗

Establishment of specific features of electron localization at U{sup -} centers in semiconductors from thermally stimulated currents

The specific features of thermally stimulated currents in semiconductors containing U{sup -} centers are treated theoretically in comparison with the corresponding features for semiconductors containing defects with a positive correlation energy or single-level centers. It is shown that the analysis of the curves of thermally stimulated currents normalized to the maximum current in respect to the shape and to the presence or absence of a shift of the temperature maximum of the curve in relation to the initial occupancy provides an extra necessary criterion for identifying defects with different parameters of binding of electrons. The results can be used in analyzing experimental data on thermally stimulated currents that exhibit features inexplicable in the context of the often used model of single-level centers.

36 MATERIALS SCIENCE↗

Stimulated radiation at a wavelength of 2.5 {mu}m at room temperature from optically excited Cd{sub x}Hg{sub 1-x}Te-based structures

The main requirements for optimization of the MCT-based (Cd{sub x}Hg{sub 1-x}Te-based) structures for an increase in the wavelength of the stimulated radiation from them under optical pumping are discussed. The emergence of stimulated radiation in MCT range of 2-2.5 {mu}m at room temperature for optimized MCT structures grown on GaAs substrates using the method of molecular beam epitaxy is shown experimentally. The obtained experimental data are the first results of observation of stimulated radiation from the MCT structures at these wavelengths at room temperature. The gain factor in the active medium measured for this case is very large and attains values of 50 cm{sup -1}, which allows one to hope that a further advance to a longer wavelengths is possible.

36 MATERIALS SCIENCE↗

Investigating the Role of TNF-α and IFN-γ Activation on the Dynamics of iNOS Gene Expression in LPS Stimulated Macrophages

Macrophage produced inducible nitric oxide synthase (iNOS) is known to play a critical role in the proinflammatory response against intracellular pathogens by promoting the generation of bactericidal reactive nitrogen species. Robust and timely production of nitric oxide (NO) by iNOS and analogous production of reactive oxygen species are critical components of an effective immune response. In addition to pathogen associated lipopolysaccharides (LPS), iNOS gene expression is dependent on numerous proinflammatory cytokines in the cellular microenvironment of the macrophage, two of which include interferon gamma (IFN-γ) and tumor necrosis factor alpha (TNF-α). To understand the synergistic effect of IFN-γ and TNF-α activation, and LPS stimulation on iNOS expression dynamics and NO production, we developed a systems biology based mathematical model. Using our model, we investigated the impact of pre-infection cytokine exposure, or priming, on the system. We explored the essentiality of IFN-γ priming to the robustness of initial proinflammatory response with respect to the ability of macrophages to produce reactive species needed for pathogen clearance. Results from our theoretical studies indicated that IFN-γ and subsequent activation of IRF1 are essential in consequential production of iNOS upon LPS stimulation. We showed that IFN-γ priming at low concentrations greatly increases the effector response of macrophages against intracellular pathogens. Ultimately the model demonstrated that although TNF-α contributed towards a more rapid response time, measured as time to reach maximum iNOS production, IFN-γ stimulation was significantly more significant in terms of the maximum expression of iNOS and the concentration of NO produced.

59 BASIC BIOLOGICAL SCIENCES↗

Single-cell correlations of mRNA and protein content in a human monocytic cell line after LPS stimulation

The heterogeneity of mRNA and protein expression at the single-cell level can reveal fundamental information about cellular response to external stimuli, including the sensitivity, timing, and regulatory interactions of genes. Here we describe a fully automated system to digitally count the intron, mRNA, and protein content of up to five genes of interest simultaneously in single-cells. Full system automation of 3D microscope scans and custom image analysis routines allows hundreds of individual cells to be automatically segmented and the mRNA-protein content to be digitally counted. Single-molecule intron and mRNA content is measured by single-molecule fluorescence in-situ hybridization (smFISH), while protein content is quantified though the use of antibody probes. To mimic immune response to bacterial infection, human monocytic leukemia cells (THP-1) were stimulated with lipopolysaccharide (LPS), and the expression of two inflammatory genes, IL1β (interleukin 1β) and TNF-α (tumor necrosis factor α), were simultaneously quantified by monitoring the intron, mRNA, and protein levels over time. The simultaneous labeling of cellular content allowed for a series of correlations at the single-cell level to be explored, both in the progressive maturation of a single gene (intron-mRNA-protein) and comparative analysis between the two immune response genes. In the absence of LPS stimulation, mRNA expression of IL1β and TNF-α were uncorrelated. Following LPS stimulation, mRNA expression of the two genes became more correlated, consistent with a model in which IL1β and TNF-α upregulation occurs in parallel through independent mechanistic pathways. This smFISH methodology can be applied to different complex biological systems to provide valuable insight into highly dynamic gene mechanisms that determine cell plasticity and heterogeneity of cellular response.

59 BASIC BIOLOGICAL SCIENCES↗

Hydraulic Fractures in Core From Stimulated Reservoirs: Core Fracture Description of HFTS Slant Core, Midland Basin, West Texas

The geometry and extent of the hydraulic-fracture network produced during well stimulation are generally not well known. Indirect methods such as microseismic monitoring may provide information about the network, but they are not definitive. The Hydraulic Fracture Test Site (HFTS) project was designed to recover core from a stimulated volume, thus providing direct information about hydraulic fractures. Here we present methods and some results from a fracture description of the HFTS slant well cores. Methods: The 4-inch-diameter cores were contained within an aluminum tube and were examined prior to slabbing. We developed criteria for distinguishing between hydraulic, natural, drilling-induced, and core-handling fractures by examining the orientation and surface features of all fractures, making use of a CT scan of the core. Results: More than 700 fractures total were found in 600 ft of core, including hydraulic fractures, two sets of calcite-sealed natural fractures, and drilling-induced and core-handling fractures. Hydraulic fractures were found to be most abundant in the section of core closest to the stimulated wells. Significance: Benefits from an experiment of this type are: (1) Hydraulic fractures are observed directly, allowing fracture density and spatial distribution to be quantified. (2) Twist hackles on hydraulic-fracture surfaces may provide information about the direction of fracture propagation. (3) The degree to which natural, sealed fractures have been reactivated may be assessed. (4) Proppant distribution in the fractures can be examined. (5) Details of the observed hydraulic-fracture network can be used to verify, or provide input data for, models of hydraulic-fracture growth and proppant distribution. (6) Findings can provide ground truth for indirect diagnostic techniques such as microseismic monitoring. (7) Fractures in core and image log in the same well can be compared, and findings used to help calibrate other horizontal well image logs.

Gale, Julia↗

Microseismic Focal Mechanisms and Implications for Changes in Stress during the 2014 Newberry EGS Stimulation

We adapt the relative polarity method from Shelly et al. (2016) to compute focal mechanisms for microearthquakes associated with the 2014 hydroshearing stimulation at the Newberry volcano geothermal site. We focus the analysis on events relocated by Aguiar and Myers (2018), who report that six event clusters predominantly comprise the 2014 sequence. Data quality allows focal mechanism analysis for four of the six event clusters. We use Hardebeck and Shearer (2002, 2003; hereafter HASH) to compute focal mechanisms based on first–motion polarities and S/P amplitude ratios. We manually determine P– and S–wave polarities for a well–recorded reference event in each cluster, then use waveform cross correlation to determine whether recordings of other events in the cluster are the same or reversed polarity at each network station. Here, most waveform polarities are consistent with the affiliated reference event, indicating similar focal mechanisms within each cluster. The deeper clusters are east–west–striking normal faults, whereas the shallower clusters, close to the top of the open–hole section of the borehole, are strike slip with east–west motion. Regional studies and prestimulation borehole breakouts find the maximum stress direction is vertical and maximum horizontal stress is approximately north–south. Fault geometry and focal mechanisms of microseismicity during the stimulation suggest that increased pressure from fluid injection predominantly caused changes in horizontal stress, consistent with predictions from numerical studies of stress change caused by fluid injection. At shallow depths, where previous studies suggest the difference between vertical and horizontal stress is lowest, injection appears to have rotated the direction of maximum stress from vertical to horizontal, resulting in strike–slip motion. At greater depth, vertical stress continued to be the dominant direction during the stimulation, but fault orientation indicates either reactivation of pre–existing fractures or rotation of the direction of maximum horizontal stress from approximately north–south to east–west.

15 GEOTHERMAL ENERGY↗

Susceptibility Study of Audio Recording Devices to Electromagnetic Stimulations

Little research has been performed to study how intentional electromagnetic signals may couple into recording devices. An electromagnetic susceptibility study was performed on an analog tape recorder, a digital video camera, a wired computer microphone, and a wireless microphone system to electromagnetic interference. Devices were subjected to electromagnetic stimulations in the frequency range of 1-990 MHz and field strengths up to 4.9 V/m. Carrier and message frequencies of the stimulation signals were swept, and the impacts of device orientation and antenna polarization were explored. Message signals coupled into all devices only when amplitude modulated signals were used as stimulation signals. Test conditions that produced maximum sensitivity were highly specific to each device. Only narrow carrier frequency ranges could be used for most devices to couple messages into recordings. A basic detection technique using cross-correlation demonstrated the need for messages to be as long as possible to maximize message detection and minimize detection error. Analysis suggests that detectable signals could be coupled to these recording devices under realistic ambient conditions.

42 ENGINEERING↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

An Integrated Multiscale Modeling Framework for Unconventional Stimulation and Production (Final Report)

The production of oil and gas from unconventional reservoirs largely depends upon two main features operating at different scales: (1) the establishment of a reservoir scale stimulated fracture network that effectively communicates with the rock volume, enhancing permeability and transport to the wellbore and (2) the coupled multi-phase flow, chemical and mechanical processes affecting the migration of hydrocarbons from the low permeability country rock adjacent to the stimulated fracture network. To date, there has been no simulation framework that allows seamless and integrated prediction of these features across spatial scales extending from the pore structure of the reservoir rock to the volume of the reservoir. In addition, there has been a lack of suitable field measurements to test such models, as stimulation and production data are often proprietary and not freely available to national laboratories and academic institutions. New multi-scale simulation capabilities are needed that are validated against suitable field-based research experiments on hydraulic fracturing and shale production.

02 PETROLEUM↗

A study of transient stimulated Raman scattering and self-focusing in the picosecond time regime

Two third order processes, stimulated Raman scattering and self-focusing, with picosecond pulses are studied. In the case of transient stimulated scattering, the gain is reduced from the steady state value, and qualitatively new features, such as shortening and delay of the Stokes pulse relative to the laser pulse, appear. These predictions are extended to realistic laser pulses, and experiments confirm all of the theoretical predictions. The self-focusing and frequency broadening of picosecond pulses is studied in the absence of stimulated Raman scattering in several materials with large orientational Kerr constants. Measurements of the relaxation time indicate that the orientational Kerr effect is important in the self-focusing of picosecond pulses. Self-focused filaments are observed to propagate with constant diameters over a distance greater than 10 cm, but disappear before the end of a 20 cm cell. The filaments radiate light continuously along their path and the spectrum of the light shows that the frequency content extends symmetrically for several hundred wave numbers on either side of the laser frequency.

Reintjes, J. F.↗

Stimulated plasma waves in the ionosphere

The reported discussion is concerned with longitudinal waves associated with electron motions. These waves are easily stimulated in the ionosphere by rocket- and satellite-borne RF sounders. Most of the observations of stimulated plasma waves in the ionosphere are based on ionograms obtained from the sounders carried on board five satellites, including Explorer 20, Alouette 1 and 2, and ISIS 1 and 2. The majority of the observations can be explained by considering the propagation of the sounder-stimulated plasma waves. Attention is given to aspects of plasma wave dispersion, linear phenomena, plasma wave instabilities and nonlinear phenomena, unexplained phenomena, diagnostic applications, geophysical and astrophysical applications, and a number of experiments planned for the future.

Benson, R. F.↗

A system for measuring thermal activation energy levels in silicon by thermally stimulated capacitance

One method being used to determine energy level(s) and electrical activity of impurities in silicon is described. The method is called capacitance transient spectroscopy (CTS). It can be classified into three basic categories: the thermally stimulated capacitance method, the voltage-stimulated capacitance method, and the light-stimulated capacitance method; the first two categories are discussed. From the total change in capacitance and the time constant of the capacitance response, emission rates, energy levels, and trap concentrations can be determined. A major advantage of using CTS is its ability to detect the presence of electrically active impurities that are invisible to other techniques, such as Zeeman effect atomic absorption, and the ability to detect more than one electrically active impurity in a sample. Examples of detection of majority and minority carrier traps from gold donor and acceptor centers in silicon using the capacitance transient spectrometer are given to illustrate the method and its sensitivity.

Cockrum, R. H.↗

Vomiting Center reanalyzed: An electrical stimulation study

Electrical stimulation of the brainstem of 15 decerebrate cats produced stimulus-bound vomiting in only 4 animals. Vomiting was reproducible in only one cat. Effective stimulating sites were located in the solitary tract and reticular formation. Restricted localization of a vomiting center, stimulation of which evoked readily reproducible results, could not be obtained.

Miller, A. D.↗

Stimulated Rayleigh-Brillouin gain spectroscopy in pure gases

Stimulated Rayleigh-Brillouin gain spectra of pure gases are reported. Stimulated Rayleigh scattering is now clearly distinguishable from stimulated Brillouin scattering without the aid of induced absorption. As examples, spectral line shapes of Ar and SF6 at various pressures and the associated gain asymmetry are discussed. Potential applications of coherent Rayleigh-Brillouin spectroscopy are suggested.

She, C. Y.↗

On the line profile coefficient for stimulated emission

It is pointed out that the line profile coefficients for spontaneous and stimulated emission are identical in low-intensity radiation fields. In more intense radiation fields, however, the stimulated emission profiles in the radiative transfer equation and in the rate equations for the atomic level populations may differ from each other, owing to their different physical nature. A seeming discrepancy between the stimulated emission profiles of the usual semi-classical aproach and a recent quantum mechanical approach by Cooper et al. (1982), which should also be valid for intense 'broadband' fields, is discussed and shown to have negligible consequences for low-intensity radiation fields.

Cooper, J.↗

The value of electrical stimulation as an exercise training modality

Voluntary exercise is the traditional way of improving performance of the human body in both the healthy and unhealthy states. Physiological responses to voluntary exercise are well documented. It benefits the functions of bone, joints, connective tissue, and muscle. In recent years, research has shown that neuromuscular electrical stimulation (NMES) simulates voluntary exercise in many ways. Generically, NMES can perform three major functions: suppression of pain, improve healing of soft tissues, and produce muscle contractions. Low frequency NMES may gate or disrupt the sensory input to the central nervous system which results in masking or control of pain. At the same time NMES may contribute to the activation of endorphins, serotonin, vasoactive intestinal polypeptides, and ACTH which control pain and may even cause improved athletic performances. Soft tissue conditions such as wounds and inflammations have responded very favorably to NMES. NMES of various amplitudes can induce muscle contractions ranging from weak to intense levels. NMES seems to have made its greatest gains in rehabilitation where directed muscle contractions may improve joint ranges of motion correct joint contractures that result from shortening muscles; control abnormal movements through facilitating recruitment or excitation into the alpha motoneuron in orthopedically, neurologically, or healthy subjects with intense sensory, kinesthetic, and proprioceptive information; provide a conservative approach to management of spasticity in neurological patients; by stimulation of the antagonist muscle to a spastic muscle stimulation of the agonist muscle, and sensory habituation; serve as an orthotic substitute to conventional bracing used with stroke patients in lieu of dorsiflexor muscles in preventing step page gait and for shoulder muscles to maintain glenohumeral alignment to prevent subluxation; and of course NMES is used in maintaining or improving the performance or torque producing capability of muscle. NMES in exercise training is our major concern.

Currier, Dean P.↗