Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE UNIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Catalytic Promotion of Transition-Metal-Doped Graphene Cathodes in Li-CO 2 Batteries

The Li-CO 2 battery is a promising energy storage system with impressive theoretical specific energy and discharge capacity. Graphene-based single-atom catalysts (SACs) provide high surface area and long-term electrochemical reactivity and stability, making SACs among the most promising cathode catalysts for these batteries. However, current Li-CO 2 systems have high reaction barriers, slowing the reaction and greatly increasing the overpotential. Improvement of the discharge/charge energetics requires atomic-level innovations in cathode design, such as alterations to the catalyst chemical structure. In this paper, we propose enhancing the SAC by using a Ti metal center, which is found to deliver the highest electrochemical Li + CO 2 activity among 3d transition metal candidates. Furthermore, we propose cathode surface coating with ionic liquids, since these environments promote the formation of reaction intermediates in the electrochemical conversion process. Here, our work provides insights to optimize electrode design for high-performance Li-CO 2 batteries, which can open new avenues to recycle greenhouse gases and achieve enhanced renewable energy storage.

25 ENERGY STORAGE↗

Pressure-Tolerant 3D Anodes Enable Short-Circuit Prevention and Low Heat Generation in Argyrodite Solid-State Batteries

Solid-state batteries (SSBs) offer a safer, higher-energy-density alternative to lithium-ion batteries, yet commercialization is hindered by incompatibility with lithium metal. Here, to overcome these challenges, we developed a cost-effective, commercially available prelithiated micro carbon fiber framework (Li-Cf) anode featuring a high-pressure-tolerance, for use with argyrodite solid-state electrolytes (SSEs). This 3D structure accommodates uniform lithium deposition, simplifies cell assembly under elevated pressure, inhibits dendrite growth toward SSEs, reduces heat generation, and enhances overall compatibility. Notably, our architecture enables the cell to tolerate pressures up to 400 MPa without short-circuiting during assembly. Meanwhile, the 3D framework serves as a preferential pathway for lithium deposition, thereby reducing lithium growth toward the SSEs and mitigating the risk of dendrite formation in SSEs. Operando calorimetry and distribution of relaxation times analysis reveal that lithium morphology degradation at the interface with the SSEs is a key failure mechanism in lithium metal argyrodite SSBs, leading to increased diffusion resistance and heat generation. In contrast, the Li-Cf anode mitigates these issues by reducing both heat flux and charge transfer resistance. Full cells with LiNi 0.8 Co 0.1 Mn 0.1 O 2 /Li 6 PS 5 Cl/Li-Cf retain ~79% capacity after 600 cycles, demonstrating significantly improved cycling stability and strong potential for practical energy storage applications.

25 ENERGY STORAGE↗

Locally Confined Polysulfide-Reactive Electrolytes for Shuttle-Free Sodium–Sulfur Batteries

Sodium-sulfur batteries promise high-energy-density and sustainable electrochemical energy storage but suffer from uncontrolled polysulfides dissolution and high sodium reactivity. These challenges fundamentally originate from poor electrolyte-electrode compatibility. Current electrolyte research inadequately addresses the trade-off between minimal polysulfides solvation and stabilizing sodium interfaces. Here, we present a locally-confined polysulfide-reactive electrolyte strategy that mediates the polysulfide dissolution dynamics and sodium stability by leveraging an electrophilic solvating species with a localized high-concentration electrolyte. This design enables shuttle-free cell operation by synergistically restricting the global solvating power of the electrolyte through intermolecular interactions and locally scavenging sparingly dissolved polysulfides via electrolyte electrophilicity. The precisely confined surface reaction facilitates a protective cathode-electrolyte interface, realizing a quasi-solid-state sulfur conversion in our liquid ether-based electrolyte, which crucially avoids crossover-induced catastrophic sodium-metal degradation. The proposed electrolyte demonstrates long-term cycling of high-mass-loading sulfur cathodes (> 3 mg S cm −2 with commercial carbon host and 70 wt% sulfur content), which afford 710 mA h g −1 over 400 cycles in coin cells and steady pouch cell operation over 180 cycles. Furthermore, this work establishes a scalable electrolyte design protocol that regulates the reaction chemistry of highly reactive electrodes, offering a pathway toward sustainable renewable energy storage.

25 ENERGY STORAGE↗

Stable cycling of high-mass loaded MnO 2 electrodes for sodium-ion batteries

Achieving cost-effective, sustainable solutions for large-scale energy storage are critical for advancing the global clean energy transition. In view of the challenges posed by limited lithium reserves, low-cost sodium-ion batteries (SIBs) have emerged as a promising direction, especially for grid-level energy storage. Among the various battery electrode materials, manganese dioxide (MnO 2 ) stands out as a favorable choice for such large-scale applications due to its earth abundance, cost-effectiveness, and non-toxic nature. Although MnO 2 is known as a pseudocapacitive material with superior cycling stability in aqueous electrolytes, its dissolution in non-aqueous electrolytes has restricted its use in long-lifetime batteries. In this study, we address two issues which have limited the use of MnO 2 electrodes in non-aqueous electrolytes. First, using electrochemical quartz crystal microbalance measurements in combination with other electrochemical methods, we demonstrate that diglyme (bis(2-methoxyethyl) ether) electrolyte can achieve stable cycling of electrodeposited ε-MnO 2 . These results enable us to tackle a second objective, that is increasing the mass loading of the MnO 2 electrode, since achieving high areal energy density is a significant factor in reducing manufacturing costs. Using 3D printed graphene aerogel (GA) as a scaffold, our studies show that the electrodeposited MnO 2 /GA electrodes possess scalable properties with mass loadings from 20 to 80 mg cm −2 . The resulting electrodes exhibit areal energy densities as high as 4.4 mA h cm −2 at a current density of 10 mA cm −2 . The high mass loaded MnO 2 electrodes were incorporated as a cathode in a SIB which used TiO 2 as the anode. The SIB device exhibited excellent performance with power densities in excess of 70 mW cm −2 . These studies highlight the promise of MnO 2 electrodes for use in a low-cost technology for large-scale energy storage.

25 ENERGY STORAGE↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

Energy Storage Grand Challenge: Energy Storage Market Report

As part of the Department of Energy's (DOE) Energy Storage Grand Challenge (ESGC), DOE intends to synthesize and disseminate best available energy storage data, information, and analysis to inform decision-making and accelerate technology adoption. The ESGC Roadmap provides options for addressing technology development, commercialization, manufacturing, valuation, and workforce challenges to position the United States for global leadership in the energy storage technologies of the future. This report provides a baseline understanding of the numerous, dynamic energy storage markets that fall within the scope of the ESGC via an integrated presentation of deployment, investment, and manufacturing data from the best, publicly-available sources. This report covers the following energy storage technologies: lithium ion batteries, lead acid batteries, pumped storage hydropower, comrpessed air energy storage, redox flow batteries, hydrogen, building thermal energy storage, and select long duration energy storage technologies. Not all energy storage technologies and markets could be addressed in this report. Due to the wide array of energy technologies, market niches, and data availability issues, this market report only included a select group of technologies. For example, thermal energy storage technologies are very broadly defined and cover a wide range of potential markets, technology readiness levels, and primary energy sources. In other areas, data scarcity necessitates a greater understanding of future applications and emerging science. Future efforts will update data presented in this report and be expanded to include other energy storage technologies. This data-driven assessment of the current status of energy storage markets is essential to track progress toward the goals described in the Energy Storage Grand Challenge and inform the decision-making of a broad range of stakeholders. At the same time, gaps identified through the development of this report can point to areas where further data collection and analysis could provide an even greater level of understanding of the full range of markets and technologies. Finally, numerous complementary analyses are planned, underway, or completed that will provide a deeper understanding of the specific technologies and markets covered at a high-level in this report.

25 ENERGY STORAGE↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Achieving gigawatt-scale green hydrogen production and seasonal storage at industrial locations across the U.S

Onsite production of gigawatt-scale wind- and solar-sourced hydrogen (H 2 ) at industrial locations depends on the ability to store and deliver otherwise-curtailed H 2 during times of power shortages. Thousands of tonnes of H 2 will require storage in regions where subsurface storage is scarce, which may only be possible using liquid organic H 2 carriers. We evaluate aboveground system with a focus on providing technical insights into toluene/methylcyclohexane (TOL/MCH) storage systems in locations suitable for gigawatt-scale wind- and solar-powered electrolyzer systems in the United States. Here we show that the levelized cost of storage, at a national median of US dollar $1.84/kg-H 2 is spatially heterogeneous, causing minor impact on the cost of H 2 supply in the Midwest, and significant impact in Central California and the Southeast. While TOL/MCH may be the cheapest aboveground bulk storage solution evaluated, upfront capital costs, modest energy efficiency, reliance on critical materials and pre-sulfided catalysts, and greenhouse gas emissions from heating are opportunities for further development.

14 SOLAR ENERGY↗

A Parallel Kinetic Model for Surface and Bulk Charge Storage in ε -MnO 2 Pseudocapacitors

Pseudocapacitive materials such as manganese dioxide (MnO 2 ) are attractive for energy storage applications due to their ability to combine the fast kinetics of capacitors with the higher energy density of battery-type systems. However, the electrochemical behavior of MnO 2 remains difficult to interpret mechanistically, in part because existing models often fail to distinguish between surface-based redox processes and bulk intercalation mechanisms. In this work, we develop a physics-based model that represents MnO 2 pseudocapacitance as a linear combination of two independent, parallel electrochemical processes: (i) the surface or near-surface redox storage and (ii) lithium ion intercalation into the bulk material. These two processes are treated with distinct kinetic and thermodynamic parameters and are assumed to proceed independently. The total measured current is assumed to be the sum of these two partial currents. We validate the model using rate-dependent cyclic voltammetry experiments, demonstrating that it captures key trends and provides physically interpretable parameters reflecting the relative contributions of surface and bulk processes. By enabling a clear separation between these mechanisms, the model offers a useful framework for analyzing pseudocapacitive materials and can guide the rational design of high-performance energy storage electrodes.

Energy - Storage↗

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Reaction Pathways over ZnZrO 2 -Based Catalysts and Catalytic Sorbents

Reactive capture and conversion (RCC) is a process intensification approach that integrates CO 2 capture and hydrogenation within a single unit, removing the CO 2 purification and storage steps of traditional process flow schemes. This alters the catalytic step from a traditional steady-state (SS) flow process to a transient capture and conversion cycle, which could lead to product distributions distinct from those observed in conventional SS experiments. Such differences are investigated in the combined capture and hydrogenation of carbon dioxide to methanol over a ZnZrO 2 catalyst and a ZnZrO 2 + NaNO 3 /Mg 3 AlO x catalytic sorbent (CS) using fixed-bed kinetic measurements, in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), and steady-state isotopic transient kinetic analysis-DRIFTS (SSITKA-DRIFTS). Under SS conditions, ZnZrO 2 produced methanol through sequential hydrogenation of HCOO* and CH 3 O* intermediates. On the contrary, CO was attributed primarily to CO 2 dissociation at oxygen vacancies, as supported by isotopic shifts and measured reaction orders. For the CS, isotopic switching experiments suggested that monodentate carbonate species (CO 3 2− , abbreviated as m-CO 3 2− ) act as active intermediates that can be hydrogenated to HCOO* and subsequently to CH 3 O. Under RCC conditions, in situ DRIFTS and isotopic experiments reveal that m-CO 3 2− species formed during the CO 2 capture step follow two competing routes upon H 2 exposure: (i) direct hydrogenation to methane on the sorbent domain or (ii) migration of m-CO 3 2− to the ZnZrO 2 domain, where they are hydrogenated to methanol through the HCOO pathway. Overall, RCC enables carbonate hydrogenation routes not observed under SS cofeed conditions. Thus, the reaction pathways and rates during RCC can be different from operation under conventional SS conditions, and the product distribution is determined here by competition between carbonate hydrogenation on sorbent sites and migration to ZnZrO 2 for methanol synthesis.

CCUS↗

System Analysis Modeling and Intermodal Transportation for Commercial Spent Nuclear Fuel

The United States Department of Energy (DOE) has long term goals to develop solutions for managing the nation’s spent nuclear fuel (SNF) and high-level waste (HLW) inventory. The Integrated Waste Management (IWM) program under the DOE office of Nuclear Energy (DOE-NE) is employing system-level engineering and analysis principles to inform potential future waste management system architectures. Managing the spent nuclear waste requires the use of system-level analysis software that takes various aspects of the fuel cycle into account like waste generation, on-site/centralized storage, transportation infrastructure, and long-term disposal. The Next Generation System Analysis Model (NGSAM) is an agent-based model that was developed to simulate the transportation and storage of SNF and HLW. As an agent-based model, NGSAM has the capability to detail the interaction and movement of individual components and groups, such as rail cars and casks. The SNF inventory from commercial nuclear reactors is currently in temporary storage at multiple locations spread across the United States. Shipping of SNF from these locations relies on one of three transportation modes: rail, heavy-haul truck, or barge. Out of the three modes identified, rail is generally the most preferred due to the size of the canisters and casks the SNF would be shipped in. However, under some scenarios, a direct rail route might not be readily available to a reactor site or improving the rail infrastructure at shutdown sites might be too cost-prohibitive for utilities to opt for a direct rail transfer. Under such scenarios, using a barge or heavy haul truck to de-inventory the site and transfer the SNF to a nearby intermodal transfer site with adequate rail infrastructure where the payload could be transferred to a rail car might prove to be an attractive option. This work initially presents the various intermodal transportation options that could be used to transfer SNF from reactor sites to rail cars. This is followed by exploring the operational steps in each of these modes to move the SNF from a reactor site and transfer it to a rail car. This work also presents the procedure of implementing the intermodal transfer methodology in NGSAM using various Java methods. Finally, the process times for accomplishing each of the individual steps are furnished. The implementation ideology, assumptions, and future steps are presented in this work.

Gadey, Harish Reddy↗

A life cycle and product type based estimator for quantifying the carbon stored in wood products

Background: Timber harvesting and industrial wood processing laterally transfer the carbon stored in forest sectors to wood products creating a wood products carbon pool. The carbon stored in wood products is allocated to end-use wood products (e.g., paper, furniture), landfill, and charcoal. Wood products can store substantial amounts of carbon and contribute to the mitigation of greenhouse effects. Therefore, accurate accounts for the size of wood products carbon pools for different regions are essential to estimating the land-atmosphere carbon exchange by using the bottom-up approach of carbon stock change. Results: To quantify the carbon stored in wood products, we developed a state-of-the-art estimator (Wood Products Carbon Storage Estimator, WPsCS Estimator) that includes the wood products disposal, recycling, and waste wood decomposition processes. The wood products carbon pool in this estimator has three subpools: (1) end-use wood products, (2) landfill, and (3) charcoal carbon. In addition, it has a user-friendly interface, which can be used to easily parameterize and calibrate an estimation. To evaluate its performance, we applied this estimator to account for the carbon stored in wood products made from the timber harvested in Maine, USA, and the carbon storage of wood products consumed in the United States. Conclusion: The WPsCS Estimator can efficiently and easily quantify the carbon stored in harvested wood products for a given region over a specific period, which was demonstrated with two illustrative examples. In addition, WPsCS Estimator has a user-friendly interface, and all parameters can be easily modified.

54 ENVIRONMENTAL SCIENCES↗

Offshore Oil and Gas Infrastructure Reuse for CCS: Opportunities and Challenges in the U.S. Gulf of Mexico

The United States Gulf of Mexico has historically been a significant oil and gas producing region and continues to produce hydrocarbons today. As such, significant investments have been made to install oil and gas infrastructure such as pipelines, platforms, and wells. As these assets reach the end of their useful life or production associated with the assets is curtailed, the assets become a liability for both the owner/operators and the U.S. and state governments responsible for regulating the assets. There are costs and risks associated with safely decommissioning the assets, and in some cases, the assets may be abandoned (e.g., the owner is no longer a going concern). In parallel, carbon capture and storage (CCS) technology has developed in the United States and interest and incentives for CCS projects have accelerated in recent years, with many public announcements of CCS projects in development in the U.S. Gulf of Mexico region. The region is particularly well-suited to CCS due to the high density of industry on the coastline (i.e., CO 2 sources) and favorable geology in the near-offshore region. CCS also requires the use of many of the same assets required for oil and gas production (pipelines, platforms, wells) and the oil and gas industry has direct experience with CO 2 transport and injection (i.e., EOR). Therefore, the combination of existing infrastructure in close proximity to potential CCS project sites appears to provide a potential “win-win” solution for re-use of existing oil and gas assets. This paper presents a high-level evaluation of oil and gas infrastructure in the Gulf of Mexico with the goals of identifying the scale of the opportunity (e.g., how much existing infrastructure is realistically re-usable), identifying gaps in knowledge/policy/information required to evaluate existing infrastructure for re-use, and proposing key actions that could be pursued to further the assessment of existing infrastructure re-use for CCS.

Infrastructure, reuse, re-purpose, oil and gas, pi↗

Developing an Analytical Framework for Cumulative Effects

The extended dry storage scenario for spent nuclear fuel (SNF) in the United States introduces the possibility of more than one transportation campaign to move the SNF from its point of origin to one or more interim storage facilities before it reaches its final destination. While the structural integrity of SNF and its storage and transportation systems are often evaluated under single event loading conditions, the reality is that a single SNF system will experience multiple structural loading events during its life cycle, the number and severity of which will depend on its individual circumstances. SNF systems will also be subjected to environmental exposure that will affect their temperature and the potential for cracks to develop in the SNF canister walls. Considered separately, many different events and scenarios might be strong enough to challenge the integrity of SNF cladding and the storage and transportations canisters that contain SNF. But considered together, over the full life cycle of an SNF system, there is the possibility that individual low-magnitude events could cause enough incremental damage to components of the SNF system to challenge its structural integrity if the time span is long enough or if the life cycle includes a sufficient number of loading events. The concern is that the cumulative effect of relatively small mechanical loads, thermal stresses, or cracking can add up to conditions that could compromise SNF or its containment structures. This report is a first step in establishing an analysis framework for evaluating these cumulative effects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gulf of Mexico Miocene CO2 Site Characterization Mega Transect

The project Gulf of Mexico Miocene CO2 Site Characterization Mega Transect is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The University of Texas at Austin study focused on (1) collecting high-resolution, 3-D (HR3D) seismic datasets of the shallow geologic section to evaluate the capacity of potential reservoirs and the sealing capacity of the confining system, and (2) producing a regional CO2 atlas of Miocene age units of the upper Texas coast submerged lands (southeast Texas). The goal of the study was to evaluate the capability of the Miocene age geologic section of Texas submerged lands to permanently store large volumes of anthropogenic CO2. The geographic locations of three HR3D, “P-Cable” seismic surveys collected in the near-shore waters of southeast Texas offers a vertical and horizontal view (data “cube”) example from the second survey. The dataset's high quality allowed for defining recognizable geologic morphologies (shapes) and possible fluid content, which are important for determining an area’s prospects for geologic storage. The regional CO2 atlas of Miocene age units highlights several topics, including: (1) a regional analyses of petroleum systems as analogs for CO2 storage; (2) petrography, petrology, and extent of confining systems of the Miocene section; (3) static capacity estimate; and (4) examples of characterization methodologies of prospect areas. The HR3D datasets and regional analyses within the CO2 atlas of the offshore Texas Miocene provide a sound basis for a future generation of specific CO2 prospects in the study area.

.las↗

Supply Chain for Photovoltaics in the United States: 2024 in Review

Solar photovoltaic (PV) and battery energy storage system (BESS) technologies are two immediately available options for meeting U.S. electricity demands, which are increasing due to expansion of loads from end uses including data centers, buildings, vehicles, and factories. Globally, PV and BESS supply chains are dominated by products manufactured in China and elsewhere by Chinese companies. However, U.S. PV and BESS manufacturing have recently grown, with some capacity in each step of the PV supply chain, albeit not enough to currently meet demand with domestic manufacturing alone. This study analyzes U.S. PV supply chains and costs in 2024, for the crystalline silicon and cadmium telluride module supply chains. The full report additionally addresses the PV balance of system, inverter and BESS supply chains. The study concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗