Reliability of Aging Polymer Components

A viscoelastic constitutive analysis is used to investigate the counter-intuitive observation of “mobility decrease with increased deformation through yield” in a glass forming polymer under compressive and tensile loading conditions. Current Sandia National Laboratory polymer models are built on the assumption that deformation enhances the mobility of the material. If this assumption is not true at small strain rates (e.g., thermal fluctuations in stockpile storage) then models will not be able to accurately predict stress evolution and potential failure of components during stockpile storage. The behavior of an epoxy thermoset is explored using an extensively validated material “clock” model, the Simplified Potential Energy Clock (SPEC) model. This methodology allows for a comparison between the linear viscoelastic (LVE) limit and the true non-linear viscoelastic (NLVE) representation and enables exploration of a wide range of conditions that are not practical to explore experimentally. The model predicts the behavior described as “mobility decrease with increased deformation” in the LVE limit and at low strain rates for NLVE. Only when loading rates are sufficient to decrease the material shift factor by multiple orders of magnitude is the anticipated deformation induced mobility or “mobility increase with increased deformation” observed. While the model has not been “trained” for these behaviors, it also predicts that the normalized stress relaxation response is indistinguishable amongst strain levels in the “post-yield” region as has been experimentally reported. At long time, which has not been examined experimentally, the model predicts the normalized relaxation curves “crossover” and return to the LVE ordering. These findings further demonstrate the ability of rheologically simple models to represent experimentally measured material response and present predictions at long time scales that could be tested experimentally.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Development of process parameters and post-build conditions for qualification of LPBF 316 SS

To harness the potential of laser powder bed fusion (LPBF) 316H stainless steel (SS) for use in advanced nuclear reactors, extensive research efforts are needed to develop optimal laser processing parameters and appropriate heat treatments, taking into account various manufacturing platforms and locations. Furthermore, it is crucial to assess the material properties in environments relevant to reactor operating conditions. In collaboration with Oak Ridge National Laboratory (ORNL) and Los Alamos National Laboratory (LANL), Argonne National Laboratory (ANL) is dedicated to gaining insights into how the manufacturing process and post-build treatments impact the performance of LPBF 316H SS. This report provides an overview of ANL's research findings for FY23, focusing on LPBF 316H SS produced using a Renishaw AM400 laser system. Specifically, our research has concentrated on three key areas: 1) Optimum laser processing parameters: Leveraging the high-throughput printing technology, we systematically varied the laser power, exposure time and point distance within the same build. By measuring the as-printed porosity, we identified an optimum printing parameter window that produced materials with near-complete density; 2) Post-built treatment development: Materials printed with the optimum laser parameters underwent treatments including stress relief, solution annealing, and hot isostatic pressing. Subsequently, we fabricated tension, creep, and fatigue specimens from materials subjected to these different conditions. Over the next year, a series of scoping tests will be conducted to facilitate the selection of the most suitable post-build treatment condition; 3) Thermal aging effects on microstructure and properties: thermal aging at 550°C, 650°C and 750°C was conducted on LPBF 316H SS specimens up to 2500 h. Microstructural characterization was performed with electron microscopy, and the evolution of the dislocation cell structures and secondary phases was studied. Microhardness tests and tension tests were conducted to quantify changes in mechanical properties. The results revealed that the aged LPBF 316H SS exhibited a high density of Cr-rich and Mo-rich fine precipitates within grains due to the presence of a high density of dislocations and the globally distributed dislocation cell structures, which served as heterogeneous nucleation sites for secondary phases. Along grain boundaries, a Mo-Cr-rich phase, observed in 750°C-aged conditions, displayed significant thermal coarsening. Throughout the aging process, various mechanisms, including stress relaxation, dislocation cell structure recovery, solution hardening, and precipitation hardening, competed to influence materials strength. These results contribute towards establishing the technical basis for qualifying LPBF 316H SS for advanced nuclear reactor applications.

36 MATERIALS SCIENCE↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Designs for Irradiation Creep Testing of SiC in HFIR

Understanding irradiation creep of nuclear fuel cladding is important to properly size the initial fuel-cladding gap and understand when pellet-cladding contact is expected to occur due to a combination of fuel swelling and cladding creep-down. Irradiation creep also plays a role in relaxing stresses that develop in-pile. Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are the leading long-term accident-tolerant fuel cladding concept for light-water reactors (LWRs). Although some limited data are available regarding irradiation creep of the individual constituents (fibers, matrix), data regarding irradiation creep of SiC/SiC composites are currently insufficient. Additional data regarding irradiation creep compliance and the rupture lifetime (combination of creep and slow crack growth) are needed to understand material limitations. This work describes the design and development of two irradiation vehicles that are being pursued for testing SiC/SiC concepts in the High Flux Isotope Reactor (HFIR). The first is a passive experiment, referred to as the PRECISE experiment, that leverages the constant coolant pressure of HFIR to compress a metallic bellows and provide a well-characterized load to drive creep in a SiC/SiC dog bone specimen. The total creep strain would be quantified post-irradiation by measuring dimensional changes of the specimen length as well as local dimensional changes within the gauge region. Non-stressed specimens would also be irradiated under the same conditions to provide an indication of dimensional changes due to radiation-induced swelling in the absence of creep. A second, more complex experiment, referred to as the INSITE experiment, is being designed in parallel that would use pneumatics to pressurize a metal bellows and linear variable differential transformers (LVDTs) to measure the specimen displacement in situ during irradiation. Such an experiment would provide significantly more data regarding the evolution of the creep compliance as a function of dose and applied stress within a single experiment but would require significantly more development time and cost to execute. The primary concern with the INSITE experiment is the accuracy, reliability, and expected lifetime of the LVDTs during irradiation at elevated temperatures. Efforts are being made to adjust the experiment design and operating procedure to limit LVDT temperatures and mitigate or otherwise compensate for uncertainties due to factors such as temperature fluctuations, creep in the surrounding structural materials, and drift of the LVDTs. This work describes the experiment designs, thermal and structural analysis that were performed to ensure that the desired temperature and stress conditions can be achieved, some initial sensitivity analyses to predict the evolution of the radiation-induced specimen displacements, and potential sources of uncertainty in the measurements. Out-of-pile testing is being performed in parallel to confirm that the test trains achieve the expected stress states in the specimens and do not result in prohibitive stress concentrators (e.g., in the grip regions) that might risk pre-mature failure. The PRECISE experiments are proceeding toward fabrication and assembly with HFIR insertion planned during fiscal year 2026. The INSITE experiment is progressing toward out-of-pile demonstrations, which will provide more conclusive evidence regarding the feasibility of executing these tests in HFIR or whether alternative displacement monitoring techniques may need to be considered.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LIFETIME PREDICTION FOR MODEL 9975 O-RINGS IN KAMS

The Savannah River Site (SRS) is currently storing plutonium materials in the K-Area Materials Storage (KAMS) facility. The materials are packaged per the DOE 3013 Standard and transported and stored in KAMS in Model 9975 shipping packages, which include double containment vessels sealed with dual O-rings made of Parker Seals compound V0835-75 (based on Viton{reg_sign} GLT). The outer O-ring of each containment vessel is credited for leaktight containment per ANSI N14.5. O-ring service life depends on many factors, including the failure criterion, environmental conditions, overall design, fabrication quality and assembly practices. A preliminary life prediction model has been developed for the V0835-75 O-rings in KAMS. The conservative model is based primarily on long-term compression stress relaxation (CSR) experiments and Arrhenius accelerated-aging methodology. For model development purposes, seal lifetime is defined as a 90% loss of measurable sealing force. Thus far, CSR experiments have only reached this target level of degradation at temperatures {ge} 300 F. At lower temperatures, relaxation values are more tolerable. Using time-temperature superposition principles, the conservative model predicts a service life of approximately 20-25 years at a constant seal temperature of 175 F. This represents a maximum payload package at a constant ambient temperature of 104 F, the highest recorded in KAMS to date. This is considered a highly conservative value as such ambient temperatures are only reached on occasion and for short durations. The presence of fiberboard in the package minimizes the impact of such temperature swings, with many hours to several days required for seal temperatures to respond proportionately. At 85 F ambient, a more realistic but still conservative value, bounding seal temperatures are reduced to {approx}158 F, with an estimated seal lifetime of {approx}35-45 years. The actual service life for O-rings in a maximum wattage package likely lies higher than the estimates due to the conservative assumptions used for the model. For lower heat loads at similar ambient temperatures, seal lifetime is further increased. The preliminary model is based on several assumptions that require validation with additional experiments and longer exposures at more realistic conditions. The assumption of constant exposure at peak temperature is believed to be conservative. Cumulative damage at more realistic conditions will likely be less severe but is more difficult to assess based on available data. Arrhenius aging behavior is expected, but non-Arrhenius behavior is possible. Validation of Arrhenius behavior is ideally determined from longer tests at temperatures closer to actual service conditions. CSR experiments will therefore continue at lower temperatures to validate the model. Ultrasensitive oxygen consumption analysis has been shown to be useful in identifying non-Arrhenius behavior within reasonable test periods. Therefore, additional experiments are recommended and planned to validate the model.

42 ENGINEERING↗

Examination of Gamma-irradiated Calcium Silicate Hydrates. Part II: Mechanical Properties

Mechanical properties of calcium silicate hydrates (C-S-H) with C/S ratios of 0.75, 1, and 1.33 were examined with nanoindentation after gamma-adsorbed doses of 0.145, 0.280, 0.500, and 0.784 MGy, and were compared with control samples. Young' s modulus and stress relaxation tests showed no apparent trend with irradiation dose. Qualitatively, most of the irradiated samples were found to relax more than their respective controls, but not always in a statistically significant manner. Most of the Young' s modulus irradiated–control pairs showed marginally higher stiffness in the irradiated samples, but overall trends with irradiation dose were not obvious. Creep compliance was obtained for the samples irradiated at the highest dose and their respective controls. Two of the three irradiated samples exhibited less creep than their respective controls, but only one of which was statistically significant. The lack of clear changes in mechanical properties for these samples correlates with separate chemical analyses that showed no loss of interlayer water by exposure to irradiation or changes in the mean silicate chain length. Further research evaluating higher doses (25 and 200 MGy) representative of those received by concrete structures in nuclear power plants at prolonged operation is being carried out to complement the present study.

36 MATERIALS SCIENCE↗

Probing viscoelastic surfaces with bimodal tapping-mode atomic force microscopy: Underlying physics and observables for a standard linear solid model

This paper presents computational simulations of single-mode and bimodal atomic force microscopy (AFM) with particular focus on the viscoelastic interactions occurring during tip–sample impact. The surface is modeled by using a standard linear solid model, which is the simplest system that can reproduce creep compliance and stress relaxation, which are fundamental behaviors exhibited by viscoelastic surfaces. The relaxation of the surface in combination with the complexities of bimodal tip–sample impacts gives rise to unique dynamic behaviors that have important consequences with regards to the acquisition of quantitative relationships between the sample properties and the AFM observables. The physics of the tip–sample interactions and its effect on the observables are illustrated and discussed, and a brief research outlook on viscoelasticity measurement with intermittent-contact AFM is provided.

36 MATERIALS SCIENCE↗

A simple and efficient quasi 3-dimensional viscoelastic model and software for simulation of tapping-mode atomic force microscopy

This study introduces a quasi-3-dimensional (Q3D) viscoelastic model and software tool for use in atomic force microscopy (AFM) simulations. The model is based on a 2-dimensional array of standard linear solid (SLS) model elements. The well-known 1-dimensional SLS model is a textbook example in viscoelastic theory but is relatively new in AFM simulation. It is the simplest model that offers a qualitatively correct description of the most fundamental viscoelastic behaviors, namely stress relaxation and creep. However, this simple model does not reflect the correct curvature in the repulsive portion of the force curve, so its application in the quantitative interpretation of AFM experiments is relatively limited. In the proposed Q3D model the use of an array of SLS elements leads to force curves that have the typical upward curvature in the repulsive region, while still offering a very low computational cost. Furthermore, the use of a multidimensional model allows for the study of AFM tips having non-ideal geometries, which can be extremely useful in practice. Examples of typical force curves are provided for single- and multifrequency tappingmode imaging, for both of which the force curves exhibit the expected features. Lastly, a software tool to simulate amplitude and phase spectroscopy curves is provided, which can be easily modified to implement other controls schemes in order to aid in the interpretation of AFM experiments.

36 MATERIALS SCIENCE↗

Plastic Deformation in Profile-Coated Elliptical KB Mirrors

Profile coating has been successfully applied to produce elliptical Kirkpatrick-Baez (KB) mirrors using both cylindrical and flat Si substrates. Previously, focusing widths of 70 nm with 15-keV monochromatic and 80 nm with white beam were achieved using a flat Si substrate. Now, precision elliptical KB mirrors with sub-nm figure errors are produced with both Au and Pt coatings on flat substrates. Recent studies of bare Si-, Au-, and Pt-coated KB mirrors under prolonged synchrotron X-ray radiation and low-temperature vacuum annealing will be discussed in terms of film stress relaxation and Si plastic deformation.

36 MATERIALS SCIENCE↗

Blister Threshold Based Thermal Limits for the U-Mo Monolithic Fuel System

Fuel failure is most commonly induced in research and test reactor fuel elements by exposure to an under-cooled or over-power condition that results in the fuel temperature exceeding a critical threshold above which blisters form on the plate. These conditions can be triggered by normal operational transients (i.e. temperature overshoots that may occur during reactor startup or power shifts) or mild upset events (e.g., pump coastdown, small blockages, mis-loading of fuel elements into higher-than-planned power positions, etc.). The rise in temperature has a number of general impacts on the state of a fuel plate that include, for example, stress relaxation in the cladding (due to differential thermal expansion), softening of the cladding, increased mobility of fission gases, and increased fission-gas pressure in pores, all of which can encourage the formation of blisters on the fuel-plate surface. These blisters consist of raised regions on the surface of fuel plates that occur when the cladding plastically deforms in response to fission-gas pressure in large pores in the fuel meat and/or mechanical buckling of the cladding over damaged regions in the fuel meat. The blister temperature threshold decreases with irradiation because the mechanical properties of the fuel plate degrade while under irradiation (due to irradiation damage and fission-product accumulation) and because the fission-gas inventory progressively increases (and, thus, so does the gas pressure in pores).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micromechanical Behavior of Solid-Solution-Strengthened Mg-1wt.%Al Alloy Investigated by In-Situ Neutron Diffraction

In-situ neutron-diffraction experiments were employed to investigate the micromechanical behavior of solid-solution-strengthened Mg-1wt.%Al alloy. Two starting textures were used: 1) as-extruded then solutionized texture, T1, in which the basal poles of most grains are tilted around 70~85 from the extrusion axis, and 2) a reoriented texture, T2, in which the basal poles of most grains are tilted around 10~20 from the extrusion axis. Lattice strains and diffraction peak intensity variations were measured in situ during loading-unloading cycles in uniaxial tension. Twinning activities and stress states for various grain orientations were revealed. The results show that the soft grain orientations, favorably oriented for either extension twinning or basal slip, exhibit the stress relaxation, resulting in the compressive residual strain after unloading. On the other hand, the hard grain orientations, unfavorably oriented for both extension twinning and basal slip, carry more applied load, leading to much higher lattice strains during loading followed by tensile residual strains upon unloading.

Lee, Sooyeol↗

Thermomechanical Characterization and Analysis of Insulation Materials for Nuclear-Based Space Power Systems

Testing was carried out to characterize and predict the long-term thermomechanical properties of various thermal insulation materials for use in nuclear-based space power systems. In particular, the high temperature compressive strength and stress relaxation behavior of these materials under vacuum or an inert atmosphere and up to 950 C were evaluated under either isothermal conditions or under various thermal gradients for test times of over two years. Several tests subjected to thermal gradient conditions were also evaluated for changes in strain due to cooling or heating events. Other testing of these materials included evaluation of their response to lateral (as opposed to axial) loads, their response to triaxial loading conditions, thermal shock behavior of these materials, and shrinkage effects in these materials due to elevated temperature exposure. Additionally, finite element and mathematical models were formulated to predict the mechanical behavior exhibited by these materials out to 35,000 hours (4 years) based on this testing. This paper will summarize the design and construction of unique test equipment to carry out this testing, along with the results of the testing and the subsequent modeling.

NESDPS Office of Nuclear Energy Space and Defense ↗

Prediction of the Creep-Fatigue Lifetime of Alloy 617: An Application of Non-destructive Evaluation and Information Integration

A relatively simple method using the nominal constant average stress information and the creep rupture model is developed to predict the creep-fatigue lifetime of Alloy 617, in terms of time to rupture. The nominal constant average stress is computed using the stress relaxation curve. The predicted time to rupture can be converted to number of cycles to failure using the strain range, the strain rate during each cycle, and the hold time information. The predicted creep-fatigue lifetime is validated against the experimental measurements of the creep-fatigue lifetime collected using conventional laboratory creep-fatigue tests. High temperature creep-fatigue tests of Alloy 617 were conducted in air at 950°C with a tensile hold period of up to 1800s in a cycle at total strain ranges of 0.3% and 0.6%. It was observed that the proposed method is conservative in that the predicted lifetime is less than the experimentally determined values. The approach would be relevant to calculate the remaining useful life to a component like a steam generator that might fail by the creep-fatigue mechanism.

36 MATERIALS SCIENCE↗

Aging Behavior of the EPDM O-Rings in the H1616 Shipping Package

The H1616 shipping package is used within the DOE complex for shipping tritium reservoirs. The annual recertification frequency can create logistical difficulties with other constraints on the timing of shipments; thus, a longer re-certification period is desirable. The ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package are being aged and tested at the Savannah River National Laboratory (SRNL) to provide a technical basis for extending the annual maintenance of the H1616 shipping package. H1616 EPDM O-rings are being aged at elevated temperature, and tested for degradation in mechanical properties, compression stress relaxation (CSR) behavior, and leak performance. Mechanical properties of aged O-rings show significant degradation can occur, but an inert atmosphere (argon backfill) greatly reduces the rate of degradation. The CSR behavior of O-rings was evaluated in air at 79 to 177 °C. These collective data were used to develop a predictive model for extrapolation of CSR behavior to relevant service temperatures (<67 °C). O-rings were also aged in H1616 Containment Vessels (CV) in an inert atmosphere at 71 to 149 °C. The vessels are helium leak tested periodically to determine if they continue to remain leak-tight. The vessel tests provide a solid demonstration that the H1616 O-rings will remain leak-tight at temperatures up to 113 °C for up to approximately 2.3 years. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in service. The predictive model developed from the CSR data conservatively indicates a service life of ~5 years at 67 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance. Based on the collective data developed to date, SRNL has recommended that the maintenance interval for the H1616 package be extended from 1 year to 2 years. Future recommendations in support of even longer maintenance intervals are expected, as additional aging data become available.

36 MATERIALS SCIENCE↗

Aging Behavior of the Viton® Fluoroelastomer O-Rings in the 9975 Shipping Package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.

36 MATERIALS SCIENCE↗