Search NASA⌕ Search

SEARCH · Search NASA

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Proof-of-Concept Studies for a Local Tie Monitoring System

We present preliminary results of proof-of-concept studies for an automatic monitoring system of local site ties. The system is based on the usage of robotic total stations. A set of tests were performed with a Leica TCA2003 total station on the local network of Goddard s Geophysical and Astronomical Observatory (GGAO) and the 5-m VLBI antenna at this site. Both the TCA2003 and the VLBI antenna are controlled from a Matlab-coded control program. Running specific observational programs, data were collected that indicate that the reference point of the VLBI antenna can be automatically determined with an accuracy of 1 mm or better.

Schmeing, Benno↗

Development of Miniaturized High-Temperature Multi-Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings.

20 FOSSIL-FUELED POWER PLANTS↗

Data Mining and Machine Learning for Power System Monitoring, Understanding, and Impact Evaluation

This chapter presents results from the Big Data analysis framework to improve power system situational awareness and system reliability. For this purpose, a dataset with real-world phasor measurement unit data and historical transmission system outage data has been created and used to carry out the analysis. Several statistical analysis and machine learning methods have been developed and implemented for event and anomaly detection and modeling. Detection and analysis results for actual examples of power system events are presented. Finally, data-driven characterization and risk assessment methods for weather-related extremes in power systems are developed and demonstrated on the Bonneville Power Administration system. These applications demonstrate the capability of Machine Learning (ML) methods to monitor system abnormalities, to predict system events, and to characterize the impact of extreme events on power grid

data mining, power grid, machine learning, anomaly↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Remote Monitoring System Design Requirements for Accountable Nuclear Materials at the Nevada National Security Site

The Nevada National Security Site (NNSS) worked with other sites within the Department of Energy National Nuclear Security Administration weapons complex to develop design requirements for a Remote Monitoring System. System objectives include: • Continuous monitoring of packaging (containers) within a Facility's buildings to meet Material Control and Accountability (MC&A) inventory requirements. • Remotely access and receive monitoring data for tamper detection/alarm, tracking information, environmental conditions, equipment metadata (serial number, date of manufacturer, etc.), and assessment video feeds. • All data processing, storage/retrieval, and communications will be protected in a manner commensurate with its trust level and classification. • Remotely collected and processed data will be securely stored, backed up, and archived. • Current and historical data will accessible within and outside of a Building (location). • Automated creation of reports and data visualization. • Design features to facilitate the potential future integration with the Facility's physical security alarm and display system. The requirements may be used to develop an integrated conceptual design or may be used in a modular fashion to inform separate designs. The guiding principles in developing the system objectives include: • For MC&A needs, remotely perform the physical inventory and evidence collection of tamper for Security Category I and II packaged material within a facility and be capable of satisfying guidelines establish by DOE M 470.4-6, “Nuclear Material Control and Accountability.” • For personnel safety needs: o Meet/satisfy Nuclear Explosive Safety requirements. o Minimize the exposure of personnel to radiation to be as low as reasonably achievable (ALARA) in accordance with NSTec Radiological Controls Manual (Ref TBD). • For DOE nuclear materials, Building environment shall be controlled to meet requirements for packaged nuclear materials specified in weapons laboratory literature.

99 GENERAL AND MISCELLANEOUS↗

Remote Monitoring System Design Requirements for Accountable Nuclear Materials at the Nevada National Security Site

The Nevada National Security Site (NNSS) worked with other sites within the Department of Energy National Nuclear Security Administration weapons complex to develop design requirements for a Remote Monitoring System. System objectives included: Continuous monitoring of packaging (containers) within a Facility's buildings to meet Material Control and Accountability (MC&A) inventory requirements. Remotely access and receive monitoring data for tamper detection/alarm, tracking information, environmental conditions, equipment metadata (serial number, date of manufacture, etc.), and assessment video feeds. All data processing, storage/retrieval, and communications will be protected in a manner commensurate with its trust level and classification. Remotely collected and processed data will be securely stored, backed up, and archived. Current and historical data will accessible within and outside of a Building (location). Automated creation of reports and data visualization. Design features to facilitate the potential future integration with the Facility's physical security alarm and display system. The requirements may be used to develop an integrated conceptual design or may be used in a modular fashion to inform separate designs. The guiding principles in developing the system objectives include: For MC&A needs, remotely perform the physical inventory and evidence collection of tamper for Security Category I and II packaged material within a facility and be capable of satisfying guidelines establish by DOE M 470.4-6, “Nuclear Material Control and Accountability.” For personnel safety needs: Meet/satisfy Nuclear Explosive Safety requirements. Minimize the exposure of personnel to radiation to be as low as reasonably achievable (ALARA) in accordance with NSTec Radiological Controls Manual. For DOE nuclear materials, Building environment shall be controlled to meet requirements for packaged nuclear materials specified in weapons laboratory literature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PNNL OS3700 Tritium Monitoring System Software and Hardware Operations Manual (Rev.2)

The Pacific Northwest National Laboratory (PNNL) OS3700 Tritium Monitoring System Software and Hardware Operations Manual describes how to install and operate the software and hardware on a personal computer operating in conjunction with the Berthold Technologies LB110 flow-through proportional counter detector system. Included are operational details for the software functions, how to read and use the dropdown menus, how to understand readings and calculations, and how to access the database tables.

54 ENVIRONMENTAL SCIENCES↗

Technology transfer potential of an automated water monitoring system

The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes.

Jamieson, W. M.↗

A noncontacting motion monitoring system for an astronaut translation aid

The development of a noncontacting motion sensing system designed to monitor the movement of a cart along a track in the low earth orbit space environment is described. The system uses Hall effect sensors to detect the position of small permanent magnets located along the track. The measurement criteria are described, the system design is discussed, and estimates of the system error are given. The system will be used on the Crew and Equipment Translation Aid (CETA) experiment scheduled for the STS37 flight in November 1990. It will allow the position, velocity, and acceleration of the cart to be determined as it moves along the track.

Finley, Tom D.↗

An Experimental Global Monitoring System for Rainfall-triggered Landslides using Satellite Remote Sensing Information

Landslides triggered by rainfall can possibly be foreseen in real time by jointly using rainfall intensity-duration thresholds and information related to land surface susceptibility. However, no system exists at either a national or a global scale to monitor or detect rainfall conditions that may trigger landslides due to the lack of extensive ground-based observing network in many parts of the world. Recent advances in satellite remote sensing technology and increasing availability of high-resolution geospatial products around the globe have provided an unprecedented opportunity for such a study. In this paper, a framework for developing an experimental real-time monitoring system to detect rainfall-triggered landslides is proposed by combining two necessary components: surface landslide susceptibility and a real-time space-based rainfall analysis system (http://trmm.gsfc.nasa.aov). First, a global landslide susceptibility map is derived from a combination of semi-static global surface characteristics (digital elevation topography, slope, soil types, soil texture, and land cover classification etc.) using a GIs weighted linear combination approach. Second, an adjusted empirical relationship between rainfall intensity-duration and landslide occurrence is used to assess landslide risks at areas with high susceptibility. A major outcome of this work is the availability of a first-time global assessment of landslide risk, which is only possible because of the utilization of global satellite remote sensing products. This experimental system can be updated continuously due to the availability of new satellite remote sensing products. This proposed system, if pursued through wide interdisciplinary efforts as recommended herein, bears the promise to grow many local landslide hazard analyses into a global decision-making support system for landslide disaster preparedness and risk mitigation activities across the world.

Hong, Yang↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Urine monitoring system failure analysis and operational verification test report

Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.

Glanfield, E. J.↗

Diagnostic procedures for Trend Monitoring System (TMS) communications

A prototype coaxial cable bus communications sytem was developed to support the trend monitoring system (TMS). Troubleshooting procedures are described at the system level. The procedures can be used by repair personnel to isolate a fault in the TMS and to restore the system to operation by swapping out failed components.

Brown, J. S.↗

Health monitoring system for the SSME - Hardware architecture study

This paper presents a hardware architecture for a health monitoring system (HMS) for the SSME. The architecture study was conducted in conjunction with a NASA sponsored program to develop a framework for SSME HMS for (1) ground test and, potentially (2) flight applications. The requirements for both systems are both stated and analyzed. A multiprocessor distributed VME system is envisioned for the ground-test hardware. By repackaging the boards, the same concept is shown to be usable for the flight system. The paper concludes with an analysis of weight, power, and reliability with respect to variations in functionality.

Kamenetz, Jeffry K.↗

Gadolinium-doped water cerenkov-based neutron and high energy gamma-ray detector and radiation portal monitoring system

A water Cerenkov-based neutron and high energy gamma ray detector and radiation portal monitoring system using water doped with a Gadolinium (Gd)-based compound as the Cerenkov radiator. An optically opaque enclosure is provided surrounding a detection chamber filled with the Cerenkov radiator, and photomultipliers are optically connected to the detect Cerenkov radiation generated by the Cerenkov radiator from incident high energy gamma rays or gamma rays induced by neutron capture on the Gd of incident neutrons from a fission source. The PMT signals are then used to determine time correlations indicative of neutron multiplicity events characteristic of a fission source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An expert system/ion trap mass spectrometry approach for life support systems monitoring

Efforts to develop sensor and control system technology to monitor air quality for life support have resulted in the development and preliminary testing of a concept based on expert systems and ion trap mass spectrometry (ITMS). An ITMS instrument provides the capability to identify and quantitate a large number of suspected contaminants at trace levels through the use of a variety of multidimensional experiments. An expert system provides specialized knowledge for control, analysis, and decision making. The system is intended for real-time, on-line, autonomous monitoring of air quality. The key characteristics of the system, performance data and analytical capabilities of the ITMS instrument, the design and operation of the expert system, and results from preliminary testing of the system for trace contaminant monitoring are described.

Palmer, Peter T.↗