Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Mars Sample Return Science Planning Group Phase 2 (MSPG2): Overview & Interim Report

Mars Sample Return (MSR) has been a high priority of the international planetary science community for decades. In recent years, significant programmatic advances have brought MSR closer to becoming a reality. In 2018, NASA and the European Space Agency (ESA) signed a joint Statement of Intent to continue defining respective roles and responsibilities in the flight missions required to realize MSR. In October 2020, NASA and ESA formalized this partnership with the signature of a Memorandum of Understanding for the MSR flight elements. The MSR campaign consists of M2020, two MSR flight elements and the ground-based infrastructure to receive, handle and curate the samples from Mars. In an engineering sense, MSR consists of a linked set of missions, and a concluding set of ground-based activities, that we refer to as the MSR Campaign.

G. Kminek↗

MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

sample chemistry↗

A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.

Viso, M.↗

Microbial ecology measurement system

The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

Source record↗

NASA Li/CF(x) cell problem analysis: Scanning electron microscopy with energy dispersive x ray spectrometry

An analysis was made of Lithium/carbon fluoride cell parts for possible chloride contamination induced by exposure to thionyl chloride (SOCl2); various samples were submitted for analysis. Only a portion of the analysis which has been conducted is covered, herein, namely analysis by scanning electron microscopy with energy dispersive x ray spectrometry (SEM/EDS). A strip of nickel was exposed to SOCl2 vapors to observe variations in surface concentrations of sulfur and chlorine with time. By detecting chlorine one can not infer contamination by SOCl2 only that contamination is present. Six samples of stainless steel foil were analyzed for chlorine using EDS. Chlorine was not detected on background samples but was detected on the samples which had been handled including those which had been cleaned. Cell covers suspected of being contaminated while in storage and covers which were not exposed to the same storage conditions were analyzed for chlorine. Although no chlorine was found on the covers from cells, it was found on all stored covers. Results are presented with techniques shown for analysis and identification. Relevant photomicrographs are presented.

Baker, John↗

Reduction of Marine Magnetic Data for Modeling the Main Field of the Earth

The marine data set archived at the National Geophysical Data Center (NGDC) consists of shipborne surveys conducted by various institutes worldwide. This data set spans four decades (1953, 1958, 1960-1987), and contains almost 13 million total intensity observations. These are often less than 1 km apart. These typically measure seafloor spreading anomalies with amplitudes of several hundred nanotesla (nT) which, since they originate in the crust, interfere with main field modeling. The source for these short wavelength features are confined within the magnetic crust (i.e., sources above the Curie isotherm). The main field, on the other hand, is of much longer wavelengths and originates within the earth's core. It is desirable to extract the long wavelength information from the marine data set for use in modeling the main field. This can be accomplished by averaging the data along the track. In addition, those data which are measured during periods of magnetic disturbance can be identified and eliminated. Thus, it should be possible to create a data set which has worldwide data distribution, spans several decades, is not contaminated with short wavelengths of the crustal field or with magnetic storm noise, and which is limited enough in size to be manageable for the main field modeling. The along track filtering described above has proved to be an effective means of condensing large numbers of shipborne magnetic data into a manageable and meaningful data set for main field modeling. Its simplicity and ability to adequately handle varying spatial and sampling constraints has outweighed consideration of more sophisticated approaches. This filtering technique also provides the benefits of smoothing out short wavelength crustal anomalies, discarding data recorded during magnetically noisy periods, and assigning reasonable error estimates to be used in the least square modeling. A useful data set now exists which spans 1953-1987.

Baldwin, R. T.↗

In Situ Strategy of the 2011 Mars Science Laboratory to Investigate the Habitability of Ancient Mars

The ten science investigations of the 2011 Mars Science Laboratory (MSL) Rover named "Curiosity" seek to provide a quantitative assessment of habitability through chemical and geological measurements from a highly capable robotic' platform. This mission seeks to understand if the conditions for life on ancient Mars are preserved in the near-surface geochemical record. These substantial payload resources enabled by MSL's new entry descent and landing (EDL) system have allowed the inclusion of instrument types nevv to the Mars surface including those that can accept delivered sample from rocks and soils and perform a wide range of chemical, isotopic, and mineralogical analyses. The Chemistry and Mineralogy (CheMin) experiment that is located in the interior of the rover is a powder x-ray Diffraction (XRD) and X-ray Fluorescence (XRF) instrument that provides elemental and mineralogical information. The Sample Analysis at Mars (SAM) suite of instruments complements this experiment by analyzing the volatile component of identically processed samples and by analyzing atmospheric composition. Other MSL payload tools such as the Mast Camera (Mastcam) and the Chemistry & Camera (ChemCam) instruments are utilized to identify targets for interrogation first by the arm tools and subsequent ingestion into SAM and CheMin using the Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem. The arm tools include the Mars Hand Lens Imager (MAHLI) and the Chemistry and Alpha Particle X-ray Spectrometer (APXX). The Dynamic Albedo of Neutrons (DAN) instrument provides subsurface identification of hydrogen such as that contained in hydrated minerals

Mahaffy, Paul R.↗

Reducing Organic Contamination in NASA JSC Astromaterial Curation Facility

Future robotic and human spaceflight missions to the Moon, Mars, asteroids and comets will require handling and storing astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. Much was learned from the rigorous attempts to minimize and monitor organic contamination during Apollo, but it was not adequate for current analytical requirements; thus [1]. OSIRIS-REx, Hayabusa-2, and future Mars sample return will require better protocols for reducing organic contamination. Future isolation con-tainment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study established the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs [2, 3]. After standard ultra-pure water (UPW) cleaning, the majority of organic contaminates found were hydrocarbons, plasticizers, silicones, and solvents. Hydro-carbons loads (> C7) ranged from 1.9 to 11.8 ng/cm2 for TD-GC-MS wafer exposure analyses and 5.0 to 19.5 ng/L for TD-GC-MS adsorbent tube exposure. Plasticizers included < 0.6 ng/cm2 of DBP, DEP, TXIB, and DIBP. Silicones included < 0.5 ng/cm2 of cyclo(Me2SiO)x (x = 6, 8, 9, 10) and siloxane. Solvents included < 1.0 ng/cm2 of 2-cyclohexen-1-one, 3,5,5-trimethyl- (Isopho-rone), N-formylpiperidine, and 2-(2-butoxyethoxy) ethanol. In addition, DBF, rubber/polymer additive was found at < 0.2 ng/cm2 and caprolactam, nylon-6 at < 0.6 ng/cm2. Reducing Organics: The Apollo program was the last sam-ple return mission to place high-level organic requirements and biological containment protocols on a curation facility. The high vacuum complex F-201 glovebox in the Lunar Receiving Labora-tory used ethyl alcohol (190 proof), 3:1 benzene/methanol (nano grade solution), and heat sterilization at 130degC for 48 hours to reduce organic contamination. In addition, both heat sterilization and peracetic acid sterilization were used in the atmospheric de-contamination (R) cabinets. Later, Lunar curation gloveboxes were degreased with a pressurized Freon 113 wash. Today, UPW has replaced Freon as the standard cleaning procedure, but does not have the degreasing solvency power of Freon. Future Cleaning Studies: Cleaning experiments are cur-rently being orchestrated to study how to degrease and reduce organics in a JSC curation glovebox lower than the established baseline. Several new chemicals in the industry have replaced traditional degreasing solvents such as Freon and others that are now federally restricted. However, these new suites of chemicals remain untested for lowering organics in curation gloveboxes. 3M's HFE-7100DL and DuPont's Vertrel XF are currently being tested as a replacement for Freon 113 as a degreaser at JSC cura-tion facilities. In addition, the use of UPW as a final rinse is be-ing tested, which presumably can maintain a lower total organic carbon load than the filtered purity of chemical solutions. References: [1] Allton J.H. et al. (2012) LPS XLIII, 2439; [2] Calaway M.

Calaway, M. J.↗

Advances in X-ray Instruments to Support Mars Sample Return

The Mars 2020 Perseverance rover is currently collecting drill cores of ancient igneous and sedimentary rock in and around Jezero crater for potential transport to Earth. These samples from the martian surface will enable detailed mineralogical, geochemical, and petrological measurements to characterize ancient depositional and diagenetic environments, quantitatively age-date the samples, and identify the building blocks for life or evidence for life itself. Furthermore, these drill cores are especially precious because they may represent the most pristine samples from the martian surface and our best chance at identifying martian life, as future sample return missions may be conducted by humans that can introduce biological contaminants to the samples. Because of the importance of these samples, we must take great care in their handling, curation, and preliminary analyses so that they are preserved for scientific measurements for decades to come. In-situ measurements by Perseverance have identified minerals that further warrant special treatment of the returned samples. Hydrated sulfate carbonate, swelling clay minerals, and oxychlorine salts are extremely sensitive to changes in temperature and relative humidity. The structures of hydrated sulfates and oxychlorine minerals, in particular, readily change when exposed to different conditions, meaning the mineral assemblage of the as-returned samples may be lost if the samples aren’t handled properly. Characterizing the as-returned mineral assemblage, particularly of the salts, is essential for reconstructing past aqueous conditions and habitability. To characterize the as-returned mineral assemblage, the samples must be analyzed rapidly before phase changes occur and/or under controlled conditions (e.g., within a glove box). Significant recent advances in X-ray instrumentation for robotic exploration of the solar system have resulted in high-resolution miniaturized instruments that would provide mineralogical, geochemical, and petrological information on the returned martian samples without degradation of the mineral assemblage. Here, we describe a combined X-ray diffractometer/X-ray fluorescence spectrometer (XRD/XRF), an X-ray computed tomographic (XCT) instrument, and a scanned beam XRF mapping instrument that could be used in a glove box so that the martian samples remain under controlled conditions.

E. B. Rampe↗

From Apollo to the Future, the NASA Curation Model for Engaging the Sample Science Community Maximizes Science on Extraterrestrial Samples

The Astromaterials Acquisition and Curation Office at Johnson Space Center (JSC) has enjoyed a long-term partnership (50 years!) with a broad community of planetary sample scientists. This partnership has enabled the curators of planetary samples to plan for and enact evolving requirements for preservation of sample scientific integrity and for handling and long-term storage. The basis for this relationship is a standing peer review advisory committee composed of leading scientists who are recognized for achievements in sample analysis. The committee and its descendants have brought familiarity with the most relevant scientific investigations and the associated analytical and contamination challenges. Beginning with Apollo, the review committee was charged with oversight of curatorial operations and with ensuring fair access to samples. As additional samples from other planetary bodies were acquired, the committee evolved, taking on new responsibilities, reflected in committee name changes. However, oversight of curatorial operations and fair allocation of samples remain basic responsibilities. Committee recommendations are sent to the NASA Headquarters Discipline Scientist for approval. To minimize conflict of interest and maximize fair access, the rules governing the make-up of the committee is structured. Systematic rotation of leadership and staggered terms of membership allow the committee to retain expertise while bringing in fresh ideas. The first peer review committee was called the Lunar Sample Analysis and Planning Team (LSAPT) and was formalized in early 1968 with about 15 members. Their function was to review a) the equipment and procedures used in the new Lunar Receiving Laboratory (LRL); b) the proficiency and capability of the LRL staff; c) the sequence of sample analysis and allocation after quarantine release; and d) the findings of the Preliminary Examination Team (PET). According to LSAPT member Gerald Wasserburg, one of the first issues they faced was deciding whether to have most of the sample analyses performed in house at the LRL or to distribute samples to members of the scientific community. LSAPT concluded that the major scientific investigations should be carried out externally to the LRL by scientists chosen for their expertise in specific disciplines. Further they recommended that the PET's basic characterization of samples be circulated to the broad scientific community. LSAPT set its own agenda, paid attention to facility details, closely monitored the move of samples from the LRL to the interim curatorial facility in 1973, and was active in inspecting curation facilities. Between 1975 and 1979, a Facility Subcommittee of LSAPT oversaw the design and construction of a permanent facility for preservation of lunar samples. The result was an outstanding facility still in use today. In 1977, a separate peer review committee, the Meteorite Working Group (MWG), was formed to evaluate requests for new meteorites then being collected in Antarctica under what would in 1980 become a 3-agency agreement (National Science Foundation, NASA, Smithsonian Institution). By 1979, after lunar samples were moved into the new permanent facility, the vacated gloveboxes and laboratory were prepared for meteorite curation. Recognizing that LSAPT had been helpful in setting up the JSC curatorial facility for Antarctic meteorites, JSC recommended the review committee be given expanded duties, including advice on curation and analysis of materials from other planetary bodies and the name be changed to Lunar and Planetary Sample Team (LAPST). In 1993, LAPST was renamed the Curation and Analysis Planning Team for Extraterrestrial Materials (CAPTEM) to reflect additional functions. CAPTEM is chartered to be (1) a community-based, interdisciplinary forum for discussion and analysis of matters concerning the collection and curation of extraterrestrial samples, including planning future sample return missions and (2) a standing review panel, charged with evaluating proposals requesting allocation of all extraterrestrial samples contained in NASA collections. Efficiency and flexibility are gained through use of subcommittees, both ad hoc and standing. Transition of the MWG to a subcommittee of CAPTEM was completed in 2017. Today subcommittees review allocation requests for lunar samples, Antarctic meteorites, cosmic dust, Stardust cometary samples, Genesis solar wind samples, and samples returned from asteroids. Other subcommittees address facilities, informatics, and micro-cratered substrates. Planetary samples have been sent to research teams in over 30 countries world-wide. The expertise in the care and fair distribution of astromaterials by NASA using this model spans generations of planetary sample scientists and is a valuable resource to be tapped for future sample returns - OSIRIS-REx, Hayabusa 2, and Mars 2020.

Allton, Judith↗

Pieces of Other Worlds - Extraterrestrial Samples for Education and Public Outreach

During the Year of the Solar System spacecraft from NASA and our international partners will encounter two comets; orbit the asteroid Vesta, continue to explore Mars with rovers, and launch robotic explorers to the Moon and Mars. We have pieces of all these worlds in our laboratories, and their continued study provides incredibly valuable "ground truth" to complement space exploration missions. Extensive information about these unique materials, as well as actual lunar samples and meteorites, are available for display and education. The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. At the current time JSC curates six types of extraterrestrial samples: (1) Moon rocks and soils collected by the Apollo astronauts (2) Meteorites collected on US expeditions to Antarctica (including rocks from the Moon, Mars, and many asteroids including Vesta) (3) "Cosmic dust" (asteroid and comet particles) collected by high-altitude aircraft (4) Solar wind atoms collected by the Genesis spacecraft (5) Comet particles collected by the Stardust spacecraft (6) Interstellar dust particles collected by the Stardust spacecraft These rocks, soils, dust particles, and atoms continue to be studied intensively by scientists around the world. Descriptions of the samples, research results, thousands of photographs, and information on how to request research samples are on the JSC Curation website: http://curator.jsc.nasa.gov/ NASA provides a limited number of Moon rock samples for either short-term or long-term displays at museums, planetariums, expositions, and professional events that are open to the public. The JSC Public Affairs Office handles requests for such display samples. Requestors should apply in writing to Mr. Louis Parker, JSC Exhibits Manager. Mr. Parker will advise successful applicants regarding provisions for receipt, display, and return of the samples. All loans will be preceded by a signed loan agreement executed between NASA and the requestor's organization. Email address: louis.a.parker@nasa.gov Sets of twelve thin sections of Apollo lunar samples and sets of twelve thin sections of meteorites are available for short-term loan from JSC Curation. The thin sections are designed for use in college and university courses where petrographic microscopes are available for viewing. Requestors should contact the Ms. Mary Luckey, Education Sample Curator. Email address: mary.k.luckey@nasa.gov

Allen, Carlton C.↗

Apollo Next Generation Sample Analysis (ANGSA): A Segue to the Next Era of Lunar Exploration and Sample Return Activities

In the fifty years since the first lunar samples were collected on Apollo 11, significant advancements have taken place in laboratory analysis, planetary science, and astromaterials curation. These advances are now being leveraged for the Apollo Next Generation Sample Analysis (ANGSA) Program, which aims to study specially curated Apollo samples that have never been studied before. Since Apollo 17 in 1972, a great deal has been learned about the Moon, including the unique environments of the poles. Building upon Apollo and remote sensing studies since then, the Artemis Program aims to explore the cold environments near the lunar south pole while achieving the concurrent goals of landing the first woman and the next man on the Moon by 2024. Recent developments for ANGSA have significantly accelerated our readiness for Artemis sample return, particularly in the area of cold sample studies. Four science teams were selected to study cold and/or volatile-bearing samples collected during the Apollo program. These samples have special storage and handling requirements that necessitate their processing in a -20°C environment that meets the Apollo materials and cleanliness requirements. NASA has recently undertaken the development and implementation of a cold sample processing facility to support ANGSA. A similar facility will be needed to process the cold, volatile-bearing samples planned to be returned by Artemis missions; therefore, ANGSA provides excellent preparation for Artemis’ future cold sample processing efforts. We will outline the goals of the ANGSA and Artemis programs, illustrating the complementary nature of the work for both. We will describe the efforts to date in designing, testing, and implementing a cold curation facility that meets the requirements of ANGSA and Apollo curation. We will then outline future work for that facility to reach operational readiness. Finally, we will present the sample collection and curation strategies for Artemis, showing how they overlap and build on ANGSA efforts. The development of cold curation at NASA represents a significant leap in the knowledge, experience, and technologies used in astromaterials curation, opening the door for new investigations of lunar volatiles, impacts, formation processes, prebiotic chemistry, and resource utilization, among many others.

Julie Mitchell↗

A new capability facilitating nuclear materials research: the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML), located in the Long Beamline Building (LBB) of the Advanced Photon Source (APS) of Argonne National Laboratory (ANL), serves as a centralized radiological facility for preparing radioactive samples for APS beamline experiments. The AML is equipped to receive shipments, handle open-form radioactive materials, encapsulate samples, and transport samples to-and-from beamline end-stations. The AML works closely with users and the APS radiological safety committee to make sure the safe conduct of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oxidation of Palladium-Chromium Alloys for High Temperature Applications

An alloy consisting of Pd with 13 wt % Cr is a promising material for high temperature applications. High temperature performance is degraded by the oxidation of the material, which is more severe in the fine wires and thin films used for sensor applications than in the bulk. The present study was undertaken to improve our understanding of the physical and chemical changes occurring at these temperatures and to identify approaches to limit oxidation of the alloy. The alloy was studied in both ribbon and wire forms. Ribbon samples were chosen to examine the role of grain boundaries in the oxidation process because of the convenience of handling for the oxidation studies. Wire samples 25 microns in diameter which are used in resistance strain gages were studied to correlate chemical properties with observed electrical, physical, and structural properties. Overcoating the material with a metallic Cr film did prevent the segregation of Pd to the surface; however, it did not eliminate the oxidation of the alloy.

Piltch, Nancy D.↗

Sample Return Systems for Extreme Environments (SaRSEE)

Sample return missions offer a greater science yield when compared to missions that only employ in situ experiments or remote sensing observations, since they allow the application of more complex technological and analytical methodologies in controlled terrestrial laboratories,that are both repeatable and can be independently verified. The successful return of extraterrestrial materials over the last four decades has contributed to our understanding of the solar system, but retrieval techniques have largely depended on the use of either soft-landing, or touch-and-go procedures that result in high V requirements, larger spacecraft mass ratios, and return yields typically limited to a few grams of surface materials that have experienced varying degrees of alteration from space weathering. Hard-landing methods using planetary penetrators offer an alternative for sample return that significantly reduce a mission's V and mass ratios,increase sample yields, and allow for the collection of subsurface materials, and lessons can be drawn from previous sample return missions. The following details progress in the design,development, and testing of penetrator/sampler technology capable of surviving subsonic and low, supersonic impact velocities (<700 m/s) that would enable the collection of geologic materials using tether technology to return the sample to a passing spacecraft. The testing of energy absorbing material for protecting the sample, design evolution and field testing of the penetrator, and dynamic modeling of tether behavior during sampling are discussed. It is shown through both modeling and field testing that penetrators at speeds between 300-600 m/s (~Mach 1-2) can penetrator into the ground to depths of 1-2 m with overall structural integrity attained.The first flight tests demonstrated the potential for survivability at these speeds. The second flight series demonstrated core sample collection with partial ejection of the sample return canister. The 3rd flight series demonstrated self-ejection of the sample return system fully intact and with the core retaining the full stratigraphy of the rock bed. The tether analysis shows that the forces on the tether during release and return of the sample to the main spacecraft are all at levels that can easily be handled by existing tether materials. The mass analysis of the requirements indicates that sample return form the asteroids could be handled with Discovery or New Frontier range of missions dependent on the number of samples to be returned to the Earth.

Winglee, R. M.↗

Gene Expression Measurement Module (GEMM) - A Fully Automated, Miniaturized Instrument for Measuring Gene Expression in Space

The capability to measure gene expression on board spacecraft opens the door to a large number of high-value experiments on the influence of the space environment on biological systems. For example, measurements of gene expression will help us to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment on a wide range of organisms from microbes to humans, develop effective countermeasures against these effects, and determine the metabolic bases of microbial pathogenicity and drug resistance. These and other applications hold significant potential for discoveries in space biology, biotechnology, and medicine. Supported by funding from the NASA Astrobiology Science and Technology Instrument Development Program, we are developing a fully automated, miniaturized, integrated fluidic system for small spacecraft capable of in-situ measurement of expression of several hundreds of microbial genes from multiple samples. The instrument will be capable of (1) lysing cell walls of bacteria sampled from cultures grown in space, (2) extracting and purifying RNA released from cells, (3) hybridizing the RNA on a microarray and (4) providing readout of the microarray signal, all in a single microfluidics cartridge. The device is suitable for deployment on nanosatellite platforms developed by NASA Ames' Small Spacecraft Division. To meet space and other technical constraints imposed by these platforms, a number of technical innovations are being implemented. The integration and end-to-end technological and biological validation of the instrument are carried out using as a model the photosynthetic bacterium Synechococcus elongatus, known for its remarkable metabolic diversity and resilience to adverse conditions. Each step in the measurement process-lysis, nucleic acid extraction, purification, and hybridization to an array-is assessed through comparison of the results obtained using the instrument with those from standard laboratory protocols. Once developed, the system can be used with minor modifications for multiple experiments on different platforms in space, including extension to higher organisms and microbial monitoring. A proposed version of GEMM that is capable of handling both microbial and tissue samples on the International Space Station will be briefly summarized.

Pohorille, Andrew↗

Genesis Solar Wind Sample Curation Documentation

Introduction: A scientist with experience as a sample science analyst, provider of flight hardware for multiple missions, and senior engineer in an ISO 2000-rated manufacturing plant has described the timeline of key participants in any PI-led sample return mission, the breadth of the organizations involved [1,2], and, of interest to this meeting, choosing the types of data to preserve and issues of future data accessibility. This work broadens that perspective by giving similar lessons from Genesis sample curation point-of-view. Curation participation regarding data gathering was part of the mission review process from the beginning. Genesis’ story illustrates outcome of several choices about types of data to record and preserve. Precision analysis of solar wind atoms captured in pure, ultraclean substrates is the driving science goal; therefore, detailed documentation was captured from all mission and curation phases and from investigator laboratories because these processes affect the final analytical results [3]. Pre-flight: Design and fabrication of the spacecraft. Like many modern small sample return missions, Genesis was a tightly managed team integrated across science, engineering and curation. Communication across the team was excellent, and, for the most part, the hands-on engineering technicians understood the impacts of “small choices” they routinely make, and the eyes-on oversight of manufacturing processes by scientists was mindful of details. The payload was designed by the Jet Propulsion Laboratory and the spacecraft by Lockheed Martin. Solar wind collectors and instruments were fabricated by multiple vendors and laboratories. The main portion of the payload was assembled at JSC. Fabrication procedures and contamination-control data (with witness coupons) were stored primarily at JSC. The original composition, dimensions and configuration of components, results of thermal testing, etc. are still needed for interpretation of analytical data. At times, these must be estimated from secondary information acquired pre-flight. Moreover, some files (e.g., original 3-D models and early Powerpoint) cannot be opened using software. Archived curation data includes 2-D drawings, material usage lists, QA documentation and analyses of consumables used during fabrication. Important chemical information still resides in archived hardware, paints and lubricants, material coupons, cleaning coupons, environmental witness plates and reference materials from manufacturing facilities. Purity and cleanliness of collector substrates. Semi-conductor vendors provided surface cleanliness data and some purity data. Purity for specific elements of interest was verified by science team members in their laboratories [4]. Curation archived procurement and shipping records, analysis reports, and non-proprietary fabrication data. A physical archive of flight collector reference materials is maintained for future use so additional data can be collected as analytical techniques improve. These are of increased value due to the hard landing upon re-entry. Cleaning and cleanliness assessments of flight hardware. Cleaning of the science canister payload was performed at JSC in a dedicated ISO 4 cleanroom using ultrapure water (UPW). The cleanliness of this UPW was monitored throughout processing. The archive for the clean lab also includes airborne particle counts, airborne molecular and inorganic contamination measurements as well as cleanroom construction material coupons and witness coupons. Hardware cleanliness was assessed by particle counts in rinse water batches. This information is recorded in batch cleaning forms and logbooks, and are, perhaps, of decreased value due to the hard landing. Post-flight: Curation-generated data. The curation handling history of each Genesis sample is documented in a typical astromaterials sample database which captures sample location, physical description and characterization data. Samples have a “shelf life”. Crucial to the preservation of samples is ongoing documentation of the sample environment, initially under curatorial control but is now a separate facility function with requires coordination. PI-generated data. Data on sample characterization and cleaning techniques continues to be generated by sample users [5]. These are often captured in LPSC abstracts, but these “engineering” results often are not publishable as stand-alone papers. We are actively looking for ways to make this information more accessible to users. Ion implants into samples have aided science return and can be shared among investigators. These (and similar) materials should be added to the curatorial collection with appropriate process and characterization data generated externally. Summary: Complete data archives for returned astromaterial samples must be broad in types and formats, and inclusive of environmental monitoring.

Genesis↗

A resolution independent neural operator

The Deep operator network (DeepONet) is a powerful yet simple neural operator architecture that utilizes two deep neural networks to learn mappings between infinite-dimensional function spaces. This architecture is highly flexible, allowing the evaluation of the solution field at any location within the desired domain. However, it imposes a strict constraint on the input space, requiring all input functions to be discretized at the same locations; this limits its practical applications. Here, in this work, we introduce a general framework for operator learning from input–output data with arbitrary number and locations of sensors. This begins by introducing a resolution-independent DeepONet (RI-DeepONet), enabling it to handle input functions that are arbitrarily, but sufficiently finely, discretized. To this end, we propose two dictionary learning algorithms to adaptively learn a set of appropriate continuous basis functions, parameterized as implicit neural representations (INRs), from correlated signals defined on arbitrary point cloud data. These basis functions are then used to project arbitrary input function data as a point cloud onto an embedding space (i.e., a vector space of finite dimensions) with dimensionality equal to the dictionary size, which can be directly used by DeepONet without any architectural changes. In particular, we utilize sinusoidal representation networks (SIRENs) as trainable INR basis functions. The introduced dictionary learning algorithms are then used in a similar way to learn an appropriate dictionary of basis functions for the output function data, which defines a new neural operator architecture referred to as the R esolution I ndependent N eural O perator (RINO). In the RINO, the operator learning task simplifies to learning a mapping from the coefficients of input basis functions to the coefficients of output basis functions. We demonstrate the robustness and applicability of RINO in handling arbitrarily (but sufficiently richly) sampled input and output functions during both training and inference through several numerical examples.

Deep operator network (DeepONet)↗