Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Exploration of the Habitability of Mars with the SAM Suite Investigation on the 2009 Mars Science Laboratory

The 2009 Mars Science Laboratory (MSL) with a substantially larger payload capability that any other Mars rover, to date, is designed to quantitatively assess a local region on Mars as a potential habitat for present or past life. Its goals are (1) to assess past or present biological potential of a target environment, (2) to characterize geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The Sample Analysis at Mars (SAM) Suite, in its final stages of integration and test, enables a sensitive search for organic molecules and chemical and isotopic analysis of martian volatiles. MSL contact and remote surface and subsurface survey Instruments establish context for these measurements and facilitate sample identification and selection. The SAM instruments are a gas chromatograph (GC), a mass spectrometer (MS), and a tunable laser spectrometer (TLS). These together with supporting sample manipulation and gas processing devices are designed to analyze either the atmospheric composition or gases extracted from solid phase samples such as rocks and fines. For example, one of the core SAM experiment sequences heats a small powdered sample of a Mars rock or soil from ambient to -1300 K in a controlled manner while continuously monitoring evolved gases. This is followed by GCMS analysis of released organics. The general chemical survey is complemented by a specific search for molecular classes that may be relevant to life including atmospheric methane and its carbon isotope with the TLS and biomarkers with the GCMS.

Mahaffy, P. R.↗

Sampling and Control Circuit Board for an Inertial Measurement Unit

A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

Chelmins, David T↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Characterization of Electronic Stress-Induced Changes in Multilayer MoS 2

Transition metal dichalcogenides like molybdenum disulfide (MoS 2 ) are compelling for next-generation electronic devices. In this work, we investigate the impact of electronic stress on MoS 2 to illustrate that observational and phenomenological information on multiple devices can be useful to describe changes in the device, and caution against the rationalization of paltry results as representative or correlative to device behavior. Here, we stress MoS 2 by applying a sustained 20 V DC bias to study the material’s response. Post-stress electronic characterization revealed nonuniform shifts in current–voltage (I–V) behavior alongside microscale changes. Complementary mechanical, spectroscopic, and scanning microwave impedance measurements showed that stress-induced features locally modulate stiffness, surface potential, Raman intensity, and charge carrier density. We correlated I–V behavior with morphological features (wrinkles, tears, folds, height) and device-level geometry (MoS 2 overlap with electrodes, channel area, contact length) on 50 test structures across five chips to move beyond anecdotal conclusions. We found no universal correlations before DC stress. However, device-level geometry was correlated with I–V behavior after DC stress, suggesting that electrode contacts play a more dominant role than morphology in determining performance. Delamination and thinning induced by DC stress led to localized reductions in charge carrier density within the affected regions. Further, delamination and thinning appear to map to I–V device performance in a few samples, but the correlation is lost when a larger sample size is considered. This suggests significant sample-to-sample variability in surface electronic states of the test structures. We also discuss how environmental factors introduced during fabrication may contribute to the observed heterogeneous device response. Progress will require high-resolution, multimodal analysis across many samples constructed under controlled, clean conditions. By building data sets that capture variability, we can better identify the true drivers of performance.

36 MATERIALS SCIENCE↗

Surface Contact Model for Comets and Asteroids

A contact force model was developed for use in touch and go (TAG) surface sampling simulations on small celestial bodies such as comets and asteroids. In TAG scenarios, a spacecraft descending toward the surface of a small body comes into contact with the surface for a short duration of time, collects material samples with a sampler device, and then ascends to leave the surface. The surface contact required 6-DOF (degrees of freedom) dynamics models due to coupling of the attitude and translation dynamics during the contact. The model described here is for contact scenarios that utilize a rotating brush wheel sampler (BWS) to collect surface material. The model includes stiffness and damping of the surface material during BWS vertical motion, lateral friction from the BWS dragging across the surface, and lateral shear from the rotating BWS scooping the surface material. This model is useful for any mission to asteroids or comets that incorporates surface sampling operations.

Blackmore, Lars James C.↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Density of NaAlSi 2 O 6 Melt at High Pressure and Temperature Measured by In-Situ X-ray Microtomography

In this study, the volumetric compression of jadeite (NaAlSi 2 O 6 ) melt at high pressures was determined by three-dimensional volume imaging using the synchrotron-based X-ray microtomography technique in a rotation-anvil device. Combined with the sample mass, measured using a high-precision analytical balance prior to the high-pressure experiment, the density of jadeite melt was obtained at high pressures and high temperatures up to 4.8 GPa and 1955 K. The density data were fitted to a third-order Birch-Murnaghan equation of state, resulting in a best-fit isothermal bulk modulus K T0 of $10.8$ $^{+1.9}_{–5.3}$ GPa and its pressure derivative K' T0 of $3.4$ $^{+6.6}_{–0.4}$. Comparison with data for silicate melts of various compositions from the literature shows that alkali-rich, polymerized melts are generally more compressible than alkali-poor, depolymerized ones. The high compressibility of jadeite melt at high pressures implies that polymerized sodium aluminosilicate melts, if generated by low-degree partial melting of mantle peridotite at ~250–400 km depth in the deep upper mantle, are likely denser than surrounding mantle materials, and thus gravitationally stable.

36 MATERIALS SCIENCE↗

Delta Modulation

An optimum adaptive delta modulator-demodulator configuration is derived. This device utilizes two past samples to obtain a step size which minimizes the mean square error for a Markov Gaussian source. The optimum system is compared using computer simulations with the linear delta modulator and an enhanced Abate delta modulator. In addition the performance is compared to the rate distortion bound for a Markov source. It is shown that the optimum delta modulator is neither quantization nor slope-overload limited. The results show that the output signal-to-noise ratio is independent of the input signal power and is subject only to the limitations of the hardware employed. In addition, voice was recorded using these systems. The demodulated voice indicates negligible degradation is caused by the optimum system and by the enhanced Abate system while the linear delta modulator suffers significant degradation at a sampling frequency of 56 kilobits/sec.

Schilling, D. L.↗

A variable-step-size robust delta modulator.

Description of an analytically obtained optimum adaptive delta modulator-demodulator configuration. The device utilizes two past samples to obtain a step size which minimizes the mean square error for a Markov-Gaussian source. The optimum system is compared, using computer simulations, with a linear delta modulator and an enhanced Abate delta modulator. In addition, the performance is compared to the rate distortion bound for a Markov source. It is shown that the optimum delta modulator is neither quantization nor slope-overload limited. The highly nonlinear equations obtained for the optimum transmitter and receiver are approximated by piecewise-linear equations in order to obtain system equations which can be transformed into hardware. The derivation of the experimental system is presented.

Song, C. L.↗