Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Effect of proton irradiation temperature on persistent photoconductivity in zinc oxide metal-semiconductor-metal ultraviolet photodetectors

The electrical and structural characteristics of 50-nm-thick zinc oxide (ZnO) metal-semiconductor-metal ultraviolet (UV) photodetectors subjected to proton irradiation at different temperatures are reported and compared. The devices were irradiated with 200 keV protons to a fluence of 1016 cm−2. Examination of the x-ray diffraction (XRD) rocking curves indicates a preferred (100) orientation prior to irradiation, with decrease in crystal quality afterward. Additionally, peak shifts in XRD and Raman spectra of the control sample relative to well-known theoretical positions are indicative of tensile strain in the as-deposited ZnO films. Shifts toward theoretical unstrained positions are observed in the irradiated films, which indicates partial relaxation. Raman spectra also indicate increase in oxygen vacancies (VO) and zinc interstitial defects (Zni) compared to the control sample. Additionally, transient photocurrent measurements performed on each sample at different temperatures showed up to 2× increase in photocurrent decay time constants for irradiated samples vs the control. This persistent photoconductive behavior is linked to the activation of electron and hole traps near the surface, and to the desorption and reabsorption of O2 molecules on the ZnO surface under the influence of UV light. Using an Arrhenius model, trap activation energies were extracted and, by comparing with known energies from the literature, the dominant defects contributing to persistent photoconductivity for each irradiation condition were identified. The persistence of differences in photocurrent transients between different samples months after irradiation indicates that the defects introduced by the suppression of thermally activated dynamic annealing processes have a long-term deleterious effect on device performance.

Heuser, Thomas A. (ORCID:0000000225642400)↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Deformation of Néel-type skyrmions revealed by Lorentz transmission electron microscopy

Néel-type magnetic skyrmions in multilayers are promising candidates for ultra-low power spintronic devices. To image the Néel-type skyrmions using Lorentz transmission electron microscopy (L-TEM), the samples must be tilted. Thus, the external magnetic field consists of both in-plane and out-of-plane components. To date, it is still not well known on the effect of the in-plane magnetic field on the L-TEM images, leading to ambiguities in retrieving the structure of Néel-type skyrmions. Here, Néel-type skyrmions in three [Pt/Co/Ta]$_{20}$ multilayer samples, with the easy magnetization axis being tuned from the out-of-plane to the in-plane direction by increasing the Co thickness from 1.8 to 2.2 nm, are imaged. When using a smaller defocus value (-2 mm) and a higher magnification (×9100) of L-TEM, a surprising dark-bright-dark-bright double contrasted pattern, instead of the previously reported dark-bright contrasted pattern, is observed. The additional dark-bright contrasted pattern becomes more evident for thicker Co layer samples in which the magnetization axis tilts more toward the in-plane direction. Further analysis, via a combination of magnetic force microscopy experiments, micromagnetic simulations, and micromagnetic analysis to Lorentz TEM simulation, shows that the additional dark-bright features originate from the deformation of the Néel-type skyrmions within an in-plane magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Second Target Station Project (CHESS Technical Report)

CHESS is a direct geometry neutron spectrometer designed to detect and analyze weak signals intrinsic to small cross-sections (e.g., small mass, small magnetic moments or neutron absorbing materials). This instrument is optimized to enable unprecedented characterization of quantum materials, spin liquids, thermoelectric and battery materials, liquids, and soft matter. The ability to simultaneously measure dynamic processes over a wide energy range for very small samples will make CHESS the spectrometer of choice for the initial exploration of new materials. The broad dynamic range will also be well matched to measurements of relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of STS enables use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single experiment. An essential feature of CHESS is the capability for polarization analysis to separate nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials, and better understanding spin-anisotropic correlations. This instrument will employ advanced sample environments such as high-pressure cells, dilution refrigerators, high field cryo-magnets and polarization devices, as well as combinations of these, to solve problems at the forefront of materials research. CHESS will be one of the flagship spectrometers of the Second Target Station (STS), providing world leading capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of the collection of mesospheric dust particles with a rocket instrument

We investigate the collection of dust particles in the mesosphere with the MESS (MEteoric Smoke Sampler) instrument that is designed to fly on a sounding rocket. We assume that the ice particles that form in the polar mesosphere between 80 and 85 km altitude in summer contain meteoric smoke particles; and these should be collected with MESS. The instrument consists of a collection device with an opening and closure mechanism, as well as an attached conic funnel which increases the sampling area in comparison to the collection area. Dust particles are collected either directly after passing through the instrument or indirectly after colliding with and fragmenting on the funnel wall. We calculate the dust and fragment trajectories in the detector to determine the collection efficiency for different particle sizes, rocket velocities, and heights, and we find the final velocities and the temperatures of the particles. The considered design has a sampling area of 62.78 mm diameter and a collection area of 20 mm diameter. For the conditions at the rocket launch site in Andøya, Norway, we estimate the collection of meteoric smoke particles contained in the ice particles to be ~10 12 –10 14 amu mm –2 . The estimated temperatures suggest that the composition of these smoke particles is not affected by the collection. Our calculations also show that keeping the instrument open above 85 km altitude increases the amount of small smoke particles that are directly collected. The directly collected smoke particles are heated as they decelerate, which can affect their composition.

47 OTHER INSTRUMENTATION↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Short-Depth QAOA circuits and Quantum Annealing on Higher-Order Ising Models (Rev.2)

The Quantum Alternating Operator Ansatz (QAOA) and Quantum Annealing (QA) are quantum algorithms that are both based on the adiabatic theorem and both have the goal of sampling the optimal solution(s) of combinatorial optimization problems. Quantum annealing has been physically instantiated on D-Wave devices using superconducting flux qubits, and QAOA can be programmed on digital gate-model quantum computers such as the programmable superconducting transmon qubits devices of the IBMQ series, for instance ibm washington. QAOA and QA address the same types of problems, but it is unclear how they will scale to large problem sizes and to larger and higher-fidelity quantum computers. In this article, we present a direct comparison between QAOA, one and two rounds, run on all 127 qubits of ibm washington and QA run on D-Wave Advantage system4.1 and Advantage system6.1. The problems which allow for this comparison are random Ising model problems whose connectivity matches the heavy hexagonal lattice topology of ibm washington and the Pegasus graph connectivity of the two D-Wave devices. We create two classes of problem instances for this comparison: one with higher order terms (ZZZ variable interactions), linear terms, and quadratic terms, and a separate problem type with only linear and quadratic terms. Our QAOA circuits are novel and extremely short depth, with a CNOT depth of 6 per round, which allows whole chip usage of ibm washington’s heavy hexagonal lattice and can be applied to future heavy-hex chips. We also test the effectiveness of the error suppression technique digital dynamical decoupling on the QAOA circuits. The QAOA circuits compiled to ibm washington are composed of several thousand circuit instructions, approximately 3, 000 depending on the details of the circuit, making these some the largest quantum circuits ever executed on a digital quantum processor. QAOA and QA are compared against the classical heuristic algorithm of simulated annealing and all problem instances are exactly solved using CPLEX in order to evaluate which samplers, if any, correctly found the ground state solution(s) of the problem instances. We find that (i) QA outperforms QAOA on all problem instances, (ii) QAOA samples the problems better than random sampling, and (iii) QAOA angle computation exhibits clear parameter concentration across the ensemble of Ising models.

127 Qubits↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond stimulated Raman spectro-microscopy for probing chemical reaction dynamics in solid-state materials

Femtosecond stimulated Raman spectroscopy (FSRS) is a chemically specific vibrational technique that has the ability to follow structural dynamics during photoinduced processes such as charge transfer on the ultrafast timescale. FSRS has a strong background in following structural dynamics and elucidating chemical mechanisms; however, its use with solid-state materials has been limited. As photovoltaic and electronic devices rely on solid-state materials, having the ability to track the evolving dynamics during their charge transfer and transport processes is crucial. Following the structural dynamics in these solid-state materials will lead to the identification of specific chemical structures responsible for various photoinduced charge transfer reactions, leading to a greater understanding of the structure–function relationships needed to improve upon current technologies. Furthermore, isolating the specific nuclear motions and molecular structures that drive a desired physical process will provide a chemical blueprint, leading to the rational design and fabrication of efficient electronic and photovoltaic devices. In this perspective, we discuss technical challenges and experimental developments that have facilitated the use of FSRS with solid-state samples, explore previous studies that have identified structure–function relationships in charge transfer reactions, and analyze the future developments that will broaden and advance the field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Cross-slip and easy-glide CRSS in titanium: Theoretical predictions and in-situ TEM measurements

This study investigates the mechanics of prismatic and first-order pyramidal $\langle$a$\rangle$ slip in titanium (Ti), elucidating the physics of easy-glide and cross-slip through a combination of theory and experiments. Screw-character prismatic (Pr) dislocations in Ti are of particular interest because their complex cores can be stable or unstable, leading to activation by either cross-slip or planar glide. To investigate these mechanisms, site-specific micro tensile samples were prepared using focused ion beam (FIB) milling and mounted on a push-to-pull (PTP) device for in-situ transmission electron microscopy (TEM) tensile testing. The in-situ experiments provide direct observations of the onset of dislocation motion and the precise determination of the critical resolved shear stress (CRSS) for the activated mechanisms, and its evolution with load cycling. A comprehensive theory has been developed to predict the CRSS values for easy glide, cross-slip, and multiplication of dislocations. Predicted critical stresses for pyramidal (π)-to-Pr and reverse cross-slip agree closely with the experimental measurements. The latter cross-slip stress is a factor of two higher than that of unobstructed planar slip. The model accounts for overlapping dislocation cores and employs a Wigner-Seitz based cell to evaluate misfit energies. By combining ab initio density functional theory (DFT) with anisotropic elasticity, the framework identifies minimum energy pathways for dislocation glide, which can be intermittent and zig-zag. A simplified expression utilizing (π) and Pr Schmid factor ratios is proposed for critical stress corresponding to (π)-to-Pr cross-slip transition. The results are strongly dependent on crystal orientation, underscoring non-Schmid behavior. Overall, this study explores key critical stress parameters essential for informing higher-scale simulations of plasticity in Ti.

Critical stress↗

Cooking methods and kitchen ventilation availability, usage, perceived performance and potential in Canadian homes

Cooking is a substantial contributor to air pollutant exposures in many residences. Effective use of kitchen ventilation can mitigate exposure; however, information on its availability, usage, and potential to increase its use across the population has been limited. This study aimed to obtain nationally representative information on cooking methods, kitchen ventilation availability and usage, and the potential for education to increase effective usage. An online survey was sent to a representative sample of Canadian homes to collect data on cooking methods, the presence and use of mechanical kitchen ventilation devices, perceived device performance, and willingness to implement mitigation strategies. Responses were weighted to match key demographic factors and analyzed using non-parametric statistics. Among the 4500 respondents, 90% had mechanical ventilation devices over the cooktop (66% of which were vented to the outside), and 30% reported regularly using their devices. Devices were used most often for deep-frying, followed by stir-frying, sautéing or pan-frying, indoor grilling, boiling or steaming. Almost half reported rarely or never using their ventilation devices during baking or oven self-cleaning. Only 10% were fully satisfied with their devices. More frequent use was associated with the device being vented to the outdoors, having more than two speed settings, quiet operation if only one speed, covering over half of the cooktop, and higher perceived effectiveness. After being informed of the benefits of kitchen ventilation, 64% indicated they would consider using their devices more often, preferentially using back burners with ventilation, and/or using higher ventilation device settings when needed. This study provides population-representative data on the most used cooking methods, kitchen ventilation availability and usage, and influencing factors in Canadian homes. Such data are needed for exposure assessments and evaluating the potential to mitigate cooking-related pollutant exposures via more effective use of kitchen ventilation. The data can be reasonably extrapolated to the United States, given the similarities in residential construction practices and cultural norms between the two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-physics modeling of tungsten collector probe samples during the WEST C4 He campaign

Abstract We describe the results of a multi-scale, multi-physics modeling assessment of SOLPS-ITER, hPIC2, RustBCA and Xolotl, in which five single-crystal tungsten (W) samples were placed in a reciprocating collector probe and exposed to helium (He) plasma in the WEST fusion device. In our models, we considered a pure (100 %) He plasma, as well as one with oxygen (O) present (95% He 5% O) corresponding to the impurity concentration estimated during the C4 He campaign in WEST. Our SOLPS simulations approximately match experimental reciprocating Langmuir probe plasma measurements of plasma density and temperature. Using these plasma parameters as input, hPIC2 and RustBCA predict that the presence of oxygen impurities lead to a 15%–20% decrease in ion and heat fluxes to the surface, and an order of magnitude higher sputtering yields (compared with a pure He plasma). Xolotl predictions for the response of tungsten to plasma surface interactions (PSIs) agree with experimental LAMS analysis, and indicate large near-surface He concentrations, which quickly decay with depth. Our model also shows an increasing role of erosion—in removing the near-surface He—with time. Overall, slightly higher retention is predicted for tungsten exposed to a pure He plasma, with the largest differences in the near-surface gas content caused by the large oxygen-induced erosion. This highlights the important role that impurities play in PSI. Therefore, future work will focus on providing a fully self-consistent description of oxygen (and oxides, etc.) in our models, through multi-species implementation in GITR and inclusion of oxygen and tungsten oxide formation in Xolotl.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent DIII-D progress toward validating models of tungsten erosion, re-deposition, and migration for application to next-step fusion devices

Abstract Fundamental mechanisms governing the erosion and prompt re-deposition of tungsten impurities in tokamak divertors are identified and analyzed to inform the lifetime of tungsten plasma-facing components in ITER and other future devices. Various experiments conducted at DIII-D to benchmark predictive models are presented, leveraging the DiMES removable sample exposure probe capability and the Metal Rings Campaign, in which toroidally symmetric rows of tungsten-coated tiles were installed in the DIII-D divertor. In tokamak divertors, the width of the electric sheath is of the order of the main ion Larmor radius, and a vast majority of sputtered tungsten impurities are typically ionized within the sheath. Therefore, W prompt redeposition is mainly governed by the ratio of the characteristic ionization mean-free path of neutral tungsten to the width of the sheath. In-situ monitoring of the prompt redeposition of tungsten impurities in divertors is demonstrated via the use of WII/WI line ratios and the ionizations/photon (S/XB) method in L-mode discharges. Even with this relatively limited set of emission measurements, net erosion measurements were found to be a consistent upper bound to an analytic scaling based on the ratio of the W ionization length, λ iz , and the width of the magnetic sheath rather than the ratio of λ iz and the W + gyro-radius. In the far-scrape-off layer (SOL) of the ITER divertor, however, it is calculated that the measurement of photon emissions associated with the ionization of tungsten impurities up to W 5 + may be required. Finally, W deposition patterns on DiMES collector probes, interpreted via DIVIMP-WallDYN modelling, reveal the key roles of progressive W erosion/re-deposition staps and E × B drifts in regulating long-range high-Z material migration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hyperdimensional scanning transmission electron microscopy and examinations and related systems, methods, and devices

A material identification system includes one or more data interfaces configured to receive first sensor data generated by a first sensor responsive to a material sample, and receive second sensor data generated by a second sensor responsive to the material sample. The material identification system also includes one or more processors configured to generate a set of predictions of an identification of the material sample and a corresponding set of certainty information.

Aguiar, Jeffery A.↗