At least 307 records · Page 17

Sensor Needs for Control and Health Management of Intelligent Aircraft Engines

NASA and the U.S. Department of Defense are conducting programs which support the future vision of "intelligent" aircraft engines for enhancing the affordability, performance, operability, safety, and reliability of aircraft propulsion systems. Intelligent engines will have advanced control and health management capabilities enabling these engines to be self-diagnostic, self-prognostic, and adaptive to optimize performance based upon the current condition of the engine or the current mission of the vehicle. Sensors are a critical technology necessary to enable the intelligent engine vision as they are relied upon to accurately collect the data required for engine control and health management. This paper reviews the anticipated sensor requirements to support the future vision of intelligent engines from a control and health management perspective. Propulsion control and health management technologies are discussed in the broad areas of active component controls, propulsion health management and distributed controls. In each of these three areas individual technologies will be described, input parameters necessary for control feedback or health management will be discussed, and sensor performance specifications for measuring these parameters will be summarized.

Simon, Donald L.↗

Secure, Autonomous, Intelligent Controller for Integrating Distributed Sensor Webs

This paper describes the infrastructure and protocols necessary to enable near-real-time commanding, access to space-based assets, and the secure interoperation between sensor webs owned and controlled by various entities. Select terrestrial and aeronautics-base sensor webs will be used to demonstrate time-critical interoperability between integrated, intelligent sensor webs both terrestrial and between terrestrial and space-based assets. For this work, a Secure, Autonomous, Intelligent Controller and knowledge generation unit is implemented using Virtual Mission Operation Center technology.

Ivancic, William D.↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Force/torque and tactile sensors for sensor-based manipulator control

The autonomy of manipulators, in space and in industrial environments, can be dramatically enhanced by the use of force/torque and tactile sensors. The development and future use of a six-component force/torque sensor for the Hermes Robot Arm (HERA) Basic End-Effector (BEE) is discussed. Then a multifunctional gripper system based on tactile sensors is described. The basic transducing element of the sensor is a sheet of pressure-sensitive polymer. Tactile image processing algorithms for slip detection, object position estimation, and object recognition are described.

Vanbrussel, H.↗

Spatial, High-Accuracy, Positioning-Encoding Sensor (SHAPES) for large space system control applications

The Spatial, High-Accuracy, Position-Encoding Sensor is a controls sensor suitable for the determination of the static shape and vibrational motion of large space structures and similar systems and for the determination of position and velocity in rendezvous and docking. It uses a combination of electro-optical techniques to measure the three-dimensional coordinates distributed over the structure at reading rates high compared to the rates at which the coordinates are changing. The technical approach is that of measuring the distance to and the direction of points on the structure from a single sensor head. Many points can be measured simultaneously from a single head without significantly increasing the complexity of the system.

Mclauchlan, J. M.↗

Fused Sensor Analysis and Advanced Control of Industrial Field Devices for Security: Cymbiote Multi-Source Sensor Fusion Platform

Embedded field devices that sense and control physical processes in critical infrastructure are soft targets for cyber-attack because they lack the fundamental features for existing cyber security monitoring and control. In this paper we present a new platform to collect and fuse data across multiple cyber and physical streams from these field devices to enable the host based attack detection and security control capabilities that have become common within IT environments. Experiments of different attack behaviors are discussed and initial machine learning detection approach analysis is presented.

Data fusion, Fied Control Device, Cyber Security, ↗

Design and implementation of sensor systems for control of a closed-loop life support system

The sensing and controlling needs for a Closed-Loop Life Support System (CLLSS) were investigated. The sensing needs were identified in five particular areas and the requirements were defined for workable sensors. The specific areas of interest were atmosphere and temperature, nutrient delivery, plant health, plant propagation and support, and solids processing. The investigation of atmosphere and temperature control focused on the temperature distribution within the growth chamber as well as the possibility for sensing other parameters such as gas concentration, pressure, and humidity. The sensing needs were studied for monitoring the solution level in a porous membrane material along with the requirements for measuring the mass flow rate in the delivery system. The causes and symptoms of plant disease were examined and the various techniques for sensing these health indicators were explored. The study of sensing needs for plant propagation and support focused on monitoring seed viability and measuring seed moisture content as well as defining the requirements for drying and storing the seeds. The areas of harvesting, food processing, and resource recycling, were covered with a main focus on the sensing possibilities for regulating the recycling process.

Alnwick, Leslie↗

Robotic Gripper With Force Control And Optical Sensors

Robotic gripper locates, measures, recognizes and manipulates objects in assembly-line setting. Fiber-optic sensors in fingertips help locate and identify object. Gripper grasps object and determines size from finger-position feedback, while grasped under force control. Prototype handles geranium cuttings in commercial greenhouse, basic concept and design modified for other objects (rods or nuts), including sorting to size.

Montgomery, James L.↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Sensor impacts on building and HVAC controls: A critical review for building energy performance

Building operations rely heavily on control systems and sensors. This paper provides a sophisticated literature review on sensor systems in building/HVAC systems, particularly in the context of controls, and their impacts on energy efficiency and thermal comfort. This study aims to understand the previous and current research and identify future research opportunities on this subject. The reviewed sensor systems were used for heuristic rule-based controls, local controls, and advanced optimal controls for existing and emerging technologies. Five major aspects of sensors are reviewed here: control loops for sensors, sensor types, sensor locations, sensor data, and a sensor impact evaluation framework. To augment the literature review, comprehensive standardized interviews were also conducted with relevant industry experts and practitioners. These interviews were designed and performed to (1) identify significant factors for selecting sensor sets and current undergoing issues, (2) identify potential improvements in sensor configuration/deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experiences to develop structured use-case scenarios. Researchers collected and analyzed 31 interview responses for this paper.

Building control↗

A CCD star sensor for fine pointing control of spaceborne telescopes

A star sensor for measuring small pointing errors in astronomical telescopes is described. By using solid state imaging arrays (CCDs) to track guide star images, this design realizes a number of performance advantages relative to more conventional approaches. Specific topics include star image position measurement, CCD sensitivity including color effects, and performance simulation results. Experimental results for CCDs operating at temperatures below 100 K are also summarized. Two telescope configurations are considered to illustrate the range of possible applications of this technology: (1) a large orbiting telescope for general astronomy requiring a multi-CCD sensor, and (2) a Space Shuttle-based infrared observatory operating at 20 K. Although the requirements and configurations of these applications are widely different, the CCD approach offers substantial advantages to both systems.

Stanton, R. H.↗