Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗

Deployment of Digital Twins and Advanced Instrumentation to Identify Looseness Between Rotor Spider Arms and Rim Attachment in Hydro Turbines

The project aimed to develop a Virtual Sensor Digital Twin (VS-DT) to monitor rotor rim float displacement (RRFD) in legacy hydropower turbines. RRFD, if undetected, can cause rotor and stator damage, leading to costly repairs and safety concerns. The purpose of the VS-DT was to predict RRFD signals using existing conventional sensors instead of installing dedicated, costly physical sensors, thereby reducing operational costs and enhancing safety.

13 HYDRO ENERGY↗

Photoluminescence Induced in Mineral Oil by Ionizing Radiation

We have studied photoluminescence (PL) properties of vacuum pump mineral oil as a function of the type and intensity of ionizing radiation exposure. The mineral oil has a simple aliphatic structure, which possesses no chromophore in the traditional sense. Unexpected PL in the mineral oil has characteristic features such as variation of the emission peak wavelength depending on the excitation wavelength and intensity dramatically increasing with radiation dose. The observed behavior can be understood in the framework of a previously suggested model introducing aggregation-induced PL and the formation of conjugated clusters comprising nontraditional chromophores. Our findings can be used for the development of optical sensors for real-time monitoring of oil utilized in vacuum pumps in nuclear fusion reactors.

Bliznyuk, Valery N.↗

Vehicle Localization in 3D World Coordinates Using Single Camera at Traffic Intersection

Optimizing traffic control systems at traffic intersections can reduce the network-wide fuel consumption, as well as emissions of conventional fuel-powered vehicles. While traffic signals have been controlled based on predetermined schedules, various adaptive signal control systems have recently been developed using advanced sensors such as cameras, radars, and LiDARs. Among these sensors, cameras can provide a cost-effective way to determine the number, location, type, and speed of the vehicles for better-informed decision-making at traffic intersections. In this research, a new approach for accurately determining vehicle locations near traffic intersections using a single camera is presented. For that purpose, a well-known object detection algorithm called YOLO is used to determine vehicle locations in video images captured by a traffic camera. YOLO draws a bounding box around each detected vehicle, and the vehicle location in the image coordinates is converted to the world coordinates using camera calibration data. During this process, a significant error between the center of a vehicle’s bounding box and the real center of the vehicle in the world coordinates is generated due to the angled view of the vehicles by a camera installed on a traffic light pole. As a means of mitigating this vehicle localization error, two different types of regression models are trained and applied to the centers of the bounding boxes of the camera-detected vehicles. The accuracy of the proposed approach is validated using both static camera images and live-streamed traffic video. Based on the improved vehicle localization, it is expected that more accurate traffic signal control can be made to improve the overall network-wide energy efficiency and traffic flow at traffic intersections.

47 OTHER INSTRUMENTATION↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a Triple Bubbler Inside Molten Salt for Pyroprocessing Safeguards Purposes

The application of a triple bubbler system within molten salt environments, specifically a eutectic mixture of LiCl-KCl, is explored for nuclear safeguards purposes, focusing on nuclear material accountancy (NMA) and holdup accountancy in pyroprocessing techniques. Traditional holdup accountancy methods, which involve periodic sampling and lengthy lead times, are being supplemented by the development of actinide sensors using electrochemistry. However, these methods alone are insufficient to meet regulatory requirements set by agencies like NRC and IAEA. The triple bubbler device measures salt level, density, and surface tension simultaneously using three dip tubes of varying diameters and heights. This study investigates the accuracy and robustness of the triple bubbler in molten salt conditions at temperatures ranging from 450-550°C. The updated bubbler design, utilizing tantalum metal and larger tube geometry, demonstrated minimal plugging and maintained measurement accuracy within acceptable uncertainties: 0.611% for depth, 1.34% for density, and approximately 40% for surface tension. Results indicate that the triple bubbler system is effective for real-time, accurate measurements in pyroprocessing environments, making it a promising tool for ensuring compliance with nuclear safeguards and supporting nuclear non-proliferation efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

In-Rod Sensor System Overview, Benefits and Recent Irradiation Test Results

Westinghouse is developing an In-Rod Sensor (IRS) System capable of measuring critical fuel rod parameters such as center-line fuel temperature, rod internal pressure and axial fuel pellet stack elongation without having penetrations to the fuel rod. The technology is similar to the Halden Reactor instrumentation, but the IRS system focuses on commercial fuel rod instrumentation. Both systems circumvent fuel rod penetrations, however the IRS system overcomes unique geometric challenges found in commercial fuel rod assemblies. The IRS could also play a key role in accelerated fuel qualification by allowing real-time measurements during separate effects tests, integral fuel testing or during irradiation of lead test rods or lead test assemblies. Combining these measurements with data acquired from targeted separate effects testing and multi-scale modelling could significantly reduce the time required to qualify new fuel and reduce the safety margin uncertainty of operating plants. The IRS is actively in development for Light Water Reactors (LWR) based fuel assemblies but can also be applied to Gen IV reactor designs with minimal modifications.

Carvajal, Jorge↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Modular Accelerator Robotics Framework for AD Robotics

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khan, M. [Fermilab; Rensselaer Poly.; Unlis↗

Modular Accelerator Robotics Framework Implementation For Accelerator Inspection

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khana, M. [Unlisted, US, IL] (ORCID:0009000↗

Developing ML/AI Methods for High-Throughput Characterization of Multiple-Sensor Streams of Tokamak Dynamics for High-Speed Control (Final Report)

This project evaluated and developed new mathematical and algorithmic techniques capable of handling (in real-time) the growing amounts of data generated by modern fusion research. While existing numerical linear algebra (NLA) methods provide the backbone to classical data analysis and algorithms, these methods fundamentally do not port to distributed architectures nor do they allow low-latency data reduction for control. Motivated by the needs for modern fusion reactors, this project explored and implemented new numerical methods to characterize plasma dynamics, respond in real-time to discharge evolution, and to process massive-scale data accurately and rapidly more fully. This project links expertise in multiple-sensor diagnostics of tokamak plasma dynamics from Columbia University’s Plasma Physics Laboratory with expertise in massive-scale data reduction and extreme data control algorithms at Columbia University’s Data Science Institute. This interdisciplinary project (i) applied machine learning methods, (ii) implemented a properly-trained neural-network for very fast processing of high-speed plasma videography, and (ii) developed the applied mathematical methods, based on randomized-NLA (rNLA) routines, for data analysis, reduction, and real-time control. The Columbia University High Beta Tokamak-Extended Pulse (HBT-EP) facility provided data to test new algorithms and partnership with Columbia University's Data Sciences Institute evaluated the broader use of new algorithms for many challenging control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Middleware for a Heterogeneous CAV Fleet

This paper introduces CAN to ROS, a model-based code generation tool used in development, testing, and deployment of a heterogeneous fleet of vehicles with robotic sensing in ROS. Code generation supports two main features: (1) self-configuration for deployment in a heterogeneous vehicle fleet, and (2) quick iteration for testing and development of reading vehicle sensors and robotic control. This tool features the ability to detect the vehicle it is in and regenerate and rebuild itself at runtime to provide the proper two-way bridge between ROS and the sensed on-board vehicle sensor network. Code generation relies on a per-model defined JSON to map a CAN database (DBC) to the desired ROS topic names and message types. The live ROS publishing of CAN messages allows for instant feedback, and the code regeneration allows for adjustments in DBC or vehicle JSON to iteratively hone in on new vehicle signals. Generated ROS nodes are written in C++ for runtime use in lightweight embedded computers. This has been tested in vehicles from three different Original Equipment Manufacturers (OEMs), and can be extended to support a wide array of vehicles. By using a unifying ROS specification, a heterogeneous set of vehicles can be unified into a fleet with abstracted model-specific details; this opens the door for developing cross-model software applications for vehicle control, connected vehicle applications, or fleet monitoring systems.

42 ENGINEERING↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

Big Data For Operation and Maintenance Cost Reduction

The purpose of this research is to develop a first-of-a-kind framework for integrating Big Data capability into the daily activities of our current fleet of nuclear power plants. Big Data is traditionally defined as data sets with high volume, velocity, and heterogeneity, and the existing Big Data analytics capabilities are now widely popular in fields such as finance, weather, e-commerce, healthcare and sports. In the nuclear industry, while the volume and velocity of data may present computational challenges for existing analytics capabilities, data heterogeneity are seen to present the major challenge. This research project mainly focuses on incorporating the wide range of data heterogeneities in nuclear power plants into an integrated Big Data Analytics capability. The primary end-product of this project is a Big Data framework that is capable of dealing with the large volume and heterogeneity of the data found in nuclear power plants to extract timely and valuable information on equipment performance. The framework can generate system insights that are actionable relations between measurable impacts and the corresponding maintenance action plans and enable optimization of plant operation and maintenance based on the extracted information. The developed framework is capable of handling heterogeneous data including both image data and time-series sensor data. Specifically, this developed framework includes the following components. The first component is an overarching maintenance ontology which includes system insights required by maintenance optimization. The maintenance ontology interacts with other components in the developed framework. The second component handles Piping & Instrumentation Diagram (P&ID) data. It can be used to extract system components and their relations automatically from the P&IDs. This extracted information is stored in the first component, i.e., maintenance ontology, and is also used as input to the third component, i.e., a tool for generating the fault tree for the corresponding system. The generated fault tree in turn is stored in the ontology for assessing risk that is used as a criterion in maintenance policy optimization. The fourth component is a tool for inferring the parameters in the Markov degradation model for a nuclear system. It uses basic information from the ontology. The fifth component is a tool for assessing the degradation level using sensor measurement data, for example, pressure, flowrate. This tool can be used for determining corrective maintenance actions. The results obtained from components four and five are returned to the ontology. The sixth component of the framework is a tool for optimizing the maintenance policy for a nuclear system of interest. It takes certain basic information from the ontology, e.g., costs of maintenance actions and system failures, as input, and returns the optimal maintenance policy to the ontology. This tool can be used for determining predictive maintenance actions. A set of experiments have also been conducted to verify the algorithms developed in this project for nuclear system degradation monitoring. The experiments are based on four solenoid valves, similar to the ones used in nuclear power plants. The analyses based on the experimental data using two algorithms, i.e., the Randomized Window Decomposition (RWD) algorithm and the particle filtering algorithm, and the results are introduced in the report. The Big Data framework developed in this project can be used as a support tool in daily activities of plant operation and maintenance and will reduce current costs while maintaining or improving safety levels. Overall, the project will not only benefit existing reactors, however it will open new frontiers to realize the long overdue value of Big Data Analytics in the nuclear sphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer↗