Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shape resonances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The winds of O-stars. II - The terminal velocities of stellar winds of O-type stars

The SEI method (Lamers et al., 1987) is used to obtain P Cygni profiles of the UV resonance lines of C IV, N V, and S IV and of the subordinate UV lines of N IV and C III observed in the spectra of 27 O-type stars. Theoretical profiles which include the turbulence effects agree well with the observations, and they can account for the deep absorption troughs, the shape of the violet absorption wings, and the wavelength of the emission peak. The resulting terminal velocities of the stellar winds are found to be systematically lower by about 400 km/s than previous estimates obtained using the Sobolev approximation (Castor and Lamers, 1979), suggesting that the narrow absorption components, observed in the UV resonance lines of O and B stars, reach the terminal velocity of the winds.

Groenewegen, M. A. T.↗

Acoustical levitation for space processing

It is pointed out that many space-manufacturing processes will require the manipulation of weightless molten material within a container in such a way that the material does not touch the container wall. A description is given of an acoustical method which can be used for the positioning and shaping of any molten material including nonconductors such as glasses. The new approach makes use of an acoustical standing wave which is excited within an enclosure or resonator.

Wang, T. G.↗

Measurement of solar gravitational oblateness with gravity gradiometers

A very high sensitivity rotating gravity gradiometer onboard the spacecraft is described for measuring the gravitational oblateness of the Sun during a solar probe mission. The proposed instrument would be a self-contained structure in a thermal-vacuum-magnetic shield in the shape of a cross, with a mass of 20 kg and arm length of 1.0 m and thickness of 0.1 m. The sensor inside would have a resonant frequency of 1/30 Hz, a mechanical Q of one million and would use gravitational radiation antenna technology to achieve a sensitivity of 6 x 10 to the minus 8th power Eotvos, which would provide a measurement of the solar oblateness to an accuracy of 1.5 to 6 x 10 to the minus 8th power. The gravity gradiometer will require a spinning spacecraft, so that it will not sense the spacecraft gravity fields, but the gradiometer does not need to be at the spacecraft center of mass, or even on the spacecraft spin axis. Major problem areas to be addressed are demonstration of the instrument sensitivity prior to flight and the measurement and compensation for any residual spacecraft angular rates.

Forward, R. L.↗

Pulse evolution and mode selection characteristics in a TEA-CO2 laser perturbed by injection of external radiation

A grating-tunable TEA-CO2 laser with an unstable resonator cavity, modified to allow injection of CW CO2 laser radiation at the resonant transition line by means of an intracavity NaCl window, has been used to study the coupling requirements for generation of single frequency pulses. The width and shape of the mode selection region, and the dependence of the gain-switched spike buildup time and the pulse shapes on the intensity and detuning frequency of the injected radiation are reported. Comparisons of the experimental results with previously reported mode selection behavior are discussed.

Flamant, P. H.↗

Stability and Spin-Orbit Resonance Analysis of Low Altitude Martian Orbits

Orbit stability has been thoughtfully studied in various celestial bodies. In particular the focus has been placed on the Moon, due to the unstable natural perturbations of its gravity field. The increasing interest in Mars orbiters brings the question of the likelihood of natural decay in low altitude regimes. This paper studies the change in shape of low altitude Mars orbits by carrying out large sets of numerical high fidelity simulations. Results showed that various configurations of the orbital elements gave perturbations that result-ed in unstable orbits. The paper also studies the potential causes of the observed unstable regions. First by taking a close look at zonal and tesseral harmonics to find the implications of Mars mass concentrations of the used gravity fields, and second by computing theoretical spin-orbit resonances to study their implications in the stability at low altitudes.

gravity perturbations↗

Theory and calculation of resonances and autoionization of two-electron atoms and ions

Techniques for calculating the electron scattering from one-electron hydrogen-like targets on the basis of the Feshback formalism, are discussed. The principal similarities between resonance parameters in the Feshbach formalism and the corresponding Breit-Wigner quantities, are described in detail. Special attention is devoted to a description of the Fano line shape parameter q, and a technique for formulating it in terms of a projector operator is proposed. The theoretical methods are illustrated by numerical calculations for 1S, 3P, and 1D states of H(-) below the first excited threshold of the target atom. Calculations of 1,3S 1,3P, 1,3D states for He are also presented.

Temkin, A.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Wireless Sensing System Using Open-circuit, Electrically-conductive Spiral-trace Sensor

A wireless sensing system includes a sensor made from an electrical conductor shaped to form an open-circuit, electrically-conductive spiral trace having inductance and capacitance. In the presence of a time-varying magnetic field, the sensor resonates to generate a harmonic response having a frequency, amplitude and bandwidth. A magnetic field response recorder wirelessly transmits the time-varying magnetic field to the sensor and wirelessly detects the sensor's response frequency, amplitude and bandwidth.

Woodard, Stanley E.↗

Electron paramagnetic resonance studies of slowly tumbling vanadyl spin probes in nematic liquid crystals

The purposes of this vanadyl spin probe study are threefold: (1) to establish when the breakdown of motionally narrowed formulas occurs; (2) to analyze the experimental vanadyl EPR line shapes by the stochastic Lioville method as developed by Polnaszek et al. (1973) for slow tumbling in an anisotropic liquid; and (3) to compare the vanadyl probe study results with those of Polnaszek and Freed (1975). Spectral EPR line shapes are simulated for experimental spectra of vanadyl acetylacetonate (VOAA) in nematic liquid crystal butyl p-(p-ethoxyphenoxycarbonyl) phenyl carbonate (BEPC) and Phase V of EM laboratories. It is shown that the use of typical vanadyl complexes as spin probes for nematic liquid crystals simplifies the theoretical analysis and the subsequent interpretation. Guidelines for the breakdown of motionally narrowed formulas are established. Both the slow tumbling aspects and the effects of non-Brownian rotation should be resolved in order to extract quantitative information about molecular ordering and rotational mobility.

Bruno, G. V.↗

Design of FIR digital filters for pulse shaping and channel equalization using time-domain optimization

Three algorithms are developed for designing finite impulse response digital filters to be used for pulse shaping and channel equalization. The first is the Minimax algorithm which uses linear programming to design a frequency-sampling filter with a pulse shape that approximates the specification in a minimax sense. Design examples are included which accurately approximate a specified impulse response with a maximum error of 0.03 using only six resonators. The second algorithm is an extension of the Minimax algorithm to design preset equalizers for channels with known impulse responses. Both transversal and frequency-sampling equalizer structures are designed to produce a minimax approximation of a specified channel output waveform. Examples of these designs are compared as to the accuracy of the approximation, the resultant intersymbol interference (ISI), and the required transmitted energy. While the transversal designs are slightly more accurate, the frequency-sampling designs using six resonators have smaller ISI and energy values.

Houts, R. C.↗

The C ring of Saturn: A high resolution view of some of its structure

Voyager 2 photopolarimeter stellar occultation data on Saturn C ring are discussed. The overall shape is much like the W-shape of other Saturnian rings and the Uranian epsilon ring. The inner structure is quite complex and it is not possible to locate the region of the weaker 1980S27 resonance. There appear to be pseudoperiodic structures, with very pronounced variations in optical depth. Possibly two isolated resonances in close proximity can develop a gravitational interaction that leads to wave patterns imposed upon the intervening ring material. The strength of the variations noted in optical depth between 90140 and 90175 km is too large to be an artifact. It could be temporal, however.

Lane, A. L.↗

Acoustic measurement of the surface tension of levitated drops

The measurement of the frequency of the fundamental mode of shape oscillation of acoustically levitated drops has been carried out to determine the surface tension of the drop material. Sound fields of about 20 kHz in frequency allow the suspension of drops a few millimeters in size, as well as the necessary drive for oscillations. The surface tension of water, hexadecane, silicone oil, and aqueous solutions of glycerin levitated in air has been measured, and the results have been compared with those obtained with standard ring tensiometry. The two sets of data are in good agreement, the largest discrepancy being about 10 percent. Uncertainties in the effects of the nonspherical static shape of drops levitated in the earth's gravitational field and the rotation state of the sample are the major contributors to the experimental error. A decrease of the resonance frequency of the fundamental mode indicates a soft nonlinearity as the oscillation amplitude increases.

Trinh, E. H.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Hot-Electron Bolometer Mixers on Silicon-on-Insulator Substrates for Terahertz Frequencies

A terahertz Hot-Electron Bolometer (HEB) mixer design using device substrates based on Silicon-On-Insulator (SOI) technology is described. This substrate technology allows very thin chips (6 pm) with almost arbitrary shape to be manufactured, so that they can be tightly fitted into a waveguide structure and operated at very high frequencies with only low risk for power leakages and resonance modes. The NbTiN-based bolometers are contacted by gold beam-leads, while other beamleads are used to hold the chip in place in the waveguide test fixture. The initial tests yielded an equivalent receiver noise temperature of 3460 K double-sideband at a local oscillator frequency of 1.462 THz and an intermediate frequency of 1.4 GHz.

bolometer↗

Analysis of Voyager spectra of the beta Cephei star nu Eridani

Voyager 500-1700 A spectrophotometric observations of the beta Cephei star nu Eri are presented and discussed. The Voyager observations were obtained in 1981 and cover six pulsation cycles of the star. These data are supplemented with a set of nine International Ultraviolet Explorer (IUE) SWP high-resolution observations covering one, earlier epoch, pulsation cycle. Light curves are derived from the Voyager data at 1055 and 1425 A. These light curves are found to be consistent in both shape and period with published optical curves. The 1055 A light curve also exhibits a phenomenon not seen in the optical curves: a small but highly significant systematic increase in the flux of the maximum light phases while maintaining a constant minimum light level over the interval of observation. Substantially larger errors in the longer wavelength data preclude discussion of this phenomenon in the 1425 A light curve. Examination of the far-UV continuum in nu Eri during this period shows that the color temperature is lower for the brighter maxima. Analysis of the far-UV continuum at maximum and minimum light yields an effective temperature difference between these two phases of 2200 + or - 750 K. Spectroscopically, three prominent features are seen in the Voyager data: a feature at 985 A mostly due to a blend of C III 977 A, H I Ly gamma 972 A, and N III 990 A; a feature at 1030 A due to H I Ly beta 1026 A and C II 1037 A; and the Si IV resonance doublet near 1400 A. A comparison of the 912-1700 A spectral region in nu Eri with a set of standard, i.e., nonpulsating stars, shows that nu Eri closely resembles the standard both in continuum shape and spectral line strengths with the possible exception of a slight flux excess between 912 and 975 A. The equivalent width of the 985 A feature is shown to vary in strength over the pulsation cycle in antiphase with the light curve and variations seen in the C IV 1548-1551 lines from the IUE data. This behavior of the 985 A feature is most likely caused by variations in the strength of the Ly gamma component of the blend. Comparisons are also made between nu Eri and the only other beta Cephei star studied in the far-UV, BW Vul, with the most notable differences between the two stars being the much larger delta(T(sub eff)) for BW Vul and the almost total absence of abnormalities in observed spectrum of nu Eri.

Porri, A.↗

Resonant isolator for maser amplifier

An isolator is described for use in a low noise maser amplifier, which provides low loss across a wide bandwidth and which can be constructed at moderate cost. The isolator includes a train of garnet or ferrite elements extending along the length of a microwave channel parallel to the slow wave structure, with the elements being of staggered height, so that the thin elements which are resonant to the microwaves are separated by much thicker elements. The thick garnet or ferrite elements reduce the magnetic flux passing through the thin elements to permit altering of the shape of the thin elements so as to facilitate their fabrication and to provide better isolation with reduced loss, by increasing the thickness of the thin elements and decreasing their length and width.

Clauss, R. C.↗

Computer modeling of pulsed CO2 lasers for lidar applications

The experimental results will enable a comparison of the numerical code output with experimental data. This will ensure verification of the validity of the code. The measurements were made on a modified commercial CO2 laser. Results are listed as following. (1) The pulse shape and energy dependence on gas pressure were measured. (2) The intrapulse frequency chirp due to plasma and laser induced medium perturbation effects were determined. A simple numerical model showed quantitative agreement with these measurements. The pulse to pulse frequency stability was also determined. (3) The dependence was measured of the laser transverse mode stability on cavity length. A simple analysis of this dependence in terms of changes to the equivalent fresnel number and the cavity magnification was performed. (4) An analysis was made of the discharge pulse shape which enabled the low efficiency of the laser to be explained in terms of poor coupling of the electrical energy into the vibrational levels. And (5) the existing laser resonator code was changed to allow it to run on the Cray XMP under the new operating system.

Spiers, Gary D.↗

[Acoustic Levitation Methods and Apparatus]

Methods are described for acoustically levitating objects within chambers of spherical and cylindrical shape. The wavelengths for chambers of particular dimensions are given, for generating standing wave patterns of any of a variety of modes within the chambers. For a spherical chamber the lowest resonant mode is excited by applying a wavelength of 3.02R, where R is the chamber radius. The two lowest pure radial modes for that chamber, are excited by applying wavelengths of 1.40R and 0.814R. For a cylindrical chamber of radius R, the lowest mode is at a wavelength of 3.41R, and the lowest pure radial modes are at wavelengths of 1.64R and 0.896R.

Barmatz, M. B.↗