Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗

Dual Fiber Spectrometer for Highly Non-Degenerate Entanglement Source

NASA is developing quantum metrology capabilities for potential space-based quantum components in future navigation and communications systems. Innate knowledge of component operation is key for the space qualification of these components. This paper focuses on the measurement and analysis of an important characteristic of an entanglement source, the joint spectrum. We describe a spectrometer based on dispersive optical fibers and present experimental measurements of the joint spectrum of a highly non-degenerate SPDC-based entanglement source that emits entangled photons in the near-infrared and telecommunications bands. How the analysis of such a joint spectrum could be applied to the modeling and simulation of entanglement swapping operations as possible extensions of quantum networks is examined. Lastly, we discuss how the separability of the two-photon state is quantified via Schmidt decomposition and how the degree of separability impacts the spectral purity of heralded single-photon emissions.

SPDC↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Temporal X-ray Reconstruction using Temporal and Spectral Measurements at LCLS

Transverse deflecting structures (TDSs) are widely used in accelerator physics to measure the longitudinal density of particle bunches. When used in combination with a dispersive section, the whole longitudinal phase space density can be imaged. At the Linac Coherent Light Source (LCLS), the installation of such a device downstream of the undulators enables the reconstruction of the X-ray temporal intensity profile by comparing longitudinal phase space distributions with lasing on and lasing off. However, the resolution of this TDS is limited to around 1 fs rms (root mean square), and therefore, it is not possible to resolve single self-amplified spontaneous emission (SASE) spikes within an X-ray photon pulse. By combining the power spectrum from a high resolution photon spectrometer and the temporal structure from the TDS, the overall resolution is enhanced, thus allowing the observation of temporal, single SASE spikes. The combined data from the spectrometer and the TDS is analysed using an iterative algorithm to obtain the actual intensity profile. In this paper, we present some improvements to the reconstruction algorithm as well as real data taken at LCLS.

47 OTHER INSTRUMENTATION↗

Fidelity Comparison of Time-Bin and Fock State Encoding in Hybrid Quantum Systems Under Channel and Transduction Effects

Future quantum networks are expected to integrate a heterogeneous combination of quantum systems, owing to the diverse advantages offered by different physical platforms in terms of scalability, coherence times, and interfacing capabilities. Within the context of this emerging quantum communication paradigm, this paper presents an analytical comparison of two photonic encoding schemes—time-bin and Fock state (single rail)—in hybrid quantum systems where flying qubits are entangled with stationary matter qubits. We evaluate their resilience against fiber channel and quantum transduction effects by calculating the fidelity of the final states relative to their ideal forms. Employing the characteristic function approach, we derive analytical fidelity expressions and investigate their dependence on parameters such as transmissivity, noise levels, fiber length, and source generation success probability. Additionally, we simulate the scenario with a dedicated QuTiP software implementation to verify the validity of the theoretical models. Our findings reveal that due to its inherent single-mode structure, the Fock state encoding consistently outperforms time-bin encoding in fidelity, as this structure significantly minimizes susceptibility to losses compared to the two-mode nature of the time-bin scheme. This analysis offers valuable insights for future hybrid quantum communication and information processing applications.

Fiorini, Francesco [Pisa U.]↗

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The CheMin XRD on the Mars Science Laboratory Rover Curiosity: Construction, Operation, and Quantitative Mineralogical Results from the Surface of Mars

The Mars Science Laboratory mission was launched from Cape Canaveral, Florida on Nov. 26, 2011 and landed in Gale crater, Mars on Aug. 6, 2012. MSL's mission is to identify and characterize ancient "habitable" environments on Mars. MSL's precision landing system placed the Curiosity rover within 2 km of the center of its 20 X 6 km landing ellipse, next to Gale's central mound, a 5,000 meter high pile of laminated sediment which may contain 1 billion years of Mars history. Curiosity carries with it a full suite of analytical instruments, including the CheMin X-ray diffractometer, the first XRD flown in space. CheMin is essentially a transmission X-ray pinhole camera. A fine-focus Co source and collimator transmits a 50μm beam through a powdered sample held between X-ray transparent plastic windows. The sample holder is shaken by a piezoelectric actuator such that the powder flows like a liquid, each grain passing in random orientation through the beam over time. Forward-diffracted and fluoresced X-ray photons from the sample are detected by an X-ray sensitive Charge Coupled Device (CCD) operated in single photon counting mode. When operated in this way, both the x,y position and the energy of each photon are detected. The resulting energy-selected Co Kalpha Debye-Scherrer pattern is used to determine the identities and amounts of minerals present via Rietveld refinement, and a histogram of all X-ray events constitutes an X-ray fluorescence analysis of the sample.The key role that definitive mineralogy plays in understanding the Martian surface is a consequence of the fact that minerals are thermodynamic phases, having known and specific ranges of temperature, pressure and composition within which they are stable. More than simple compositional analysis, definitive mineralogical analysis can provide information about pressure/temperature conditions of formation, past climate, water activity and the like. Definitive mineralogical analyses are necessary to establish the origin or provenance of a sample. The search for evidence of extant or extinct life on Mars will initially be a search for evidence of present or past conditions supportive of life (e.g., evidence of water), not for life itself.Results of the first 1,000 sols (Mars days) will be discussed, including the discovery of the first habitable environment on Mars.

CheMin↗

Transformer coupled toroidal wave-heated remote plasma sources operating in Ar/NF 3 mixtures

Remote plasmas are used in semiconductor device manufacturing as sources of radicals for chamber cleaning and isotropic etching. In these applications, large fluxes of neutral radicals (e.g. F, O, Cl, H) are desired with there being negligible fluxes of potentially damaging ions and photons. One remote plasma source (RPS) design employs toroidal, transformer coupling using ferrite cores to dissociate high flows of moderately high pressure (up to several Torr) electronegative gases. In this paper, results are discussed from a computational investigation of moderate pressure, toroidal transformer coupled RPS sustained in Ar and Ar/NF 3 mixtures. Operation of the RPS in 1 Torr (133 Pa) of argon with a power of 1.0 kW at 0.5 MHz and a single core produces a continuous toroidal plasma loop with current continuity being maintained dominantly by conduction current. Operation with dual cores introduces azimuthal asymmetries with local maxima in plasma density. Current continuity is maintained by a mix of conduction and displacement current. Operation in NF 3 for the same conditions produces essentially complete NF 3 dissociation. Electron depletion as a result of dissociative attachment of NF 3 and NF x fragments significantly alters the discharge topology, confining the electron density to the downstream portion of the source where the NFx density has been lowered by this dissociation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A loophole-free Bell's inequality experiment

The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

Kwiat, Paul G.↗

Free-electron crystals for enhanced X-ray radiation

Abstract Bremsstrahlung—the spontaneous emission of broadband radiation from free electrons that are deflected by atomic nuclei—contributes to the majority of X-rays emitted from X-ray tubes and used in applications ranging from medical imaging to semiconductor chip inspection. Here, we show that the bremsstrahlung intensity can be enhanced significantly—by more than three orders of magnitude—through shaping the electron wavefunction to periodically overlap with atoms in crystalline materials. Furthermore, we show how to shape the bremsstrahlung X-ray emission pattern into arbitrary angular emission profiles for purposes such as unidirectionality and multi-directionality. Importantly, we find that these enhancements and shaped emission profiles cannot be attributed solely to the spatial overlap between the electron probability distribution and the atomic centers, as predicted by the paraxial and non-recoil theory for free electron light emission. Our work highlights an unprecedented regime of free electron light emission where electron waveshaping provides multi-dimensional control over practical radiation processes like bremsstrahlung. Our results pave the way towards greater versatility in table-top X-ray sources and improved fundamental understanding of quantum electron-light interactions.

47 OTHER INSTRUMENTATION↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Estimate of Gamma Dose Rates from Arrays of Fermi-1 Blanket Elements During the MEDE Process

The Enrico Fermi Atomic Power Plant Unit 1 (Fermi-1) was a sodium-cooled fast breeder reactor located in Monroe County, Michigan. The reactor was powered by a core of enriched uranium metal alloy driver fuel, which was enveloped by an axial and radial blanket material consisting of depleted uranium metal alloyed with 3 wt.% molybdenum. There are 406 axial and 559 radial irradiated sodium-bonded Fermi-1 blanket assemblies in storage at INL, totaling 34 metric tons of heavy metal. Disposal of the Fermi-1 blanket material directly into a geological repository is prohibited due to the reactive characteristic of its bond sodium. A melt drain evaporate (MEDE) process can effectively remove bond sodium from Fermi-1 blanket material. Consequently, planning is underway to apply a MEDE process to treat the 34 metric tons of heavy metal of irradiated Fermi-1 blanket material. Given the irradiated Fermi-1 blanket material’s relatively low power history and 50+ years of decay, it can be treated in a shielded glovebox. To assess the requisite shielding, the dose rates of the Fermi-1 blanket elements in various process configurations are needed. The method to perform the dose rate calculations is to first generate an average source term and associated photon source spectra for the Fermi-1 blanket material in SCALE and then use the associated photon spectra to calculate dose rates using MCNP6.2 in seven representative geometries. Dose rates in rem/h were calculated on contact (1 cm from outer geometry surface), 30 cm away from outer geometry surface, and 1 m from outer geometry surface at axial heights spanning the length of the blanket material within the geometry. The maximum average dose rate for the single Fermi-1 radial blanket element is ~0.60 rem/h, for the Fermi-1 radial blanket assembly ~1.10 rem/h, for the single Fermi-1 axial blanket element ~0.5 rem/h, for the Fermi-1 axial blanket assembly ~1.01 rem/h, for the MEDE can ~ 0.98 rem/h, for the Fermi Storage Canister ~ 0.83 rem/h, and for the MEDE cans in the DOE Standard Canister ~0.51 rem/h. Based on these maximum average values, the bounding dose rates are assumed to be 3× the average dose rates calculated for the axial blanket material and 7.6× the average dose rates calculated for the radial blanket material, based on the distribution of Fermi-1 blanket material assembly burnup.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver

The simplified architecture is a minimal system for a deep-space optical communications transceiver. For a deepspace optical communications link the simplest form of the transceiver requires (1) an efficient modulated optical source, (2) a point-ahead mechanism (PAM) to compensate for two-way light travel, (3) an aperture to reduce the divergence of the transmit laser communication signal and also to collect the uplink communication signal, and (4) a receive detector to sense the uplink communication signal. Additional components are introduced to mitigate for spacecraft microvibrations and to improve the pointing accuracy. The Canonical Transceiver implements this simplified architecture (see figure). A single photon-counting smart focal plane sensor combines acquisition, tracking, and forward link data detection functionality. This improves optical efficiency by eliminating channel splits. A transmit laser blind sensor (e.g. silicon with 1,550-nm beam) provides transmit beam-pointing feedback via the two-photon absorption (TPA) process. This vastly improves the transmit/receive isolation because only the focused transmit beam is detected. A piezoelectric tiptilt actuator implements the required point-ahead angle. This point-ahead mechanism has been demonstrated to have near zero quiescent power and is flight qualified. This architecture also uses an innovative 100-mHz resonant frequency passive isolation platform to filter spacecraft vibrations with voice coil actuators for active tip-tilt correction below the resonant frequency. The canonical deep-space optical communications transceiver makes synergistic use of innovative technologies to reduce size, weight, power, and cost. This optical transceiver can be used to retire risks associated with deep-space optical communications on a planetary pathfinder mission and is complementary to ongoing lunar and access link developments.

Ortiz, Gerard G.↗

Dispersive optical systems for scalable Raman driving of hyperfine qubits

Hyperfine atomic states are among the most promising candidates for qubit encoding in quantum information processing. In atomic systems, hyperfine transitions are typically driven through a two-photon Raman process by a laser field which is amplitude modulated at the hyperfine qubit frequency. Here we introduce a method for generating amplitude modulation by phase modulating a laser and reflecting it from a highly dispersive optical element known as a chirped Bragg grating. This approach is passively stable, offers high efficiency, and is compatible with high-power laser sources, enabling large Rabi frequencies and improved quantum coherence. We benchmark this approach by globally driving an array of approximately 300 neutral 87 Rb atomic qubits trapped in optical tweezers and obtain Rabi frequencies of 2 MHz with photon-scattering error rates of less than 2×10 -4 per π pulse. This robust approach can be directly integrated with local addressing optics in both neutral atom and trapped ion systems to facilitate high-fidelity single-qubit operations for quantum information processing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and Performance of the CdZnTe VFG Imaging Calorimeter Prototype for Gamma-ray Astronomy

We present the design and first results of the CdZnTe Imaging calorimeter prototype. The CdZnTe Imaging calorimeter has been designed for use in large astrophysical gamma-ray space instruments, and we report here on a small prototype built to validate the approach. The calorimeter is based on virtual Frisch-grid drift-bar CdZnTe detectors. The design is modular, such that multiple crates of 16 bars, each served by a single ASIC, can be arranged in to different configurations depending on the specific requirements for an instrument. The modules are plugged into the readout motherboard in the designed configuration for a given instrument. The detectors are capable of measuring the interaction point of an incident photon in three dimensions and the energy deposited. In this work, we have designed and built a prototype consisting of 4 by 4 module array and have tested it with various radioactive sources to measure its position and energy resolution. The preliminary results demonstrate ~1% FWHM energy resolution and 1-2 mm position resolution for 662 keV photons (Cs137), subject to the further improvement by applying various corrections. We tested the module with a “conventional” analog ASIC readout as well as a wave-front sampling ASIC to compare the results, which is critical for the optimization of the future instrument.

A. A. Moiseev↗

Stability and Viability of Off-Axis Photoemission Geometries in 4D Ultrafast Electron Microscopy

Femtosecond (fs) laser-based 4D ultrafast electron microscopy (UEM) commonly makes use of photoelectron emission from a source material in the electron gun region of an otherwise conventional TEM. For TEMs equipped with thermionic guns, the source material is often LaB 6 , the same as used for thermionic operation. Here, such thermionic-based UEMs have proven useful for applications requiring large electron fluxes (i.e., high beam currents) often at the expense of beam coherence and brightness, which is especially important for single-shot nanosecond applications. Importantly, for fs-based UEMs, beam currents can be controlled over a broad range of parameter space through the properties of the fs laser and the photon pulses produced therefrom.

Willis, Simon A. [University of Minnesota, Minneap↗

Spatially and Temporally-Resolved Multi-Parameter Interferometric Rayleigh Scattering

A novel approach to simultaneously measure the translational temperature, bulk velocity, and density in gases by collecting, referencing, and analyzing nanosecond time-scale Rayleigh scattered light from molecules is described. A narrow-band pulsed laser source is used to probe two largely separated measurement locations, one of which is used for reference. The elastically scattered photons containing information from both measurement locations are collected at the same time and analyzed spectrally using a planar Fabry - Perot interferometer. A practical means of referencing the measurement of velocity using the laser frequency, and the density and temperature using the information from the reference measurement location maintained at constant properties is described. To demonstrate the technique single-shot spectra of elastic scattered light are obtained in a near zero velocity H2-air Hencken burner flame and simultaneously in an N2-filled gas cell. A simplified Gaussian distribution model to the scattered light spectra is used to obtain the flame properties. Corrections to this model are applied at lower gas temperatures when the simplified Gaussian approximation is no longer suitable. The near-zero measured velocity as a function of the measured flame temperature, and a comparison of the measured flame density and temperature with the perfect gas law are presented.

Bivolaru, Daniel↗