Search NASA⌕ Search

SEARCH · Search NASA

Results for “Site occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Crystal structure of Methanococcus jannaschii dihydroorotase with substrate bound

Here, we report the X-ray structural analysis of dihydroorotase from Methanococcus jannaschii co-crystallized with dihydroorotate at pH 6.5. The crystals are isomorphous with the crystals of the apoenzyme, with space group P3 2 21 and unit-cell dimensions a = b = 111.4, c = 101.2 Å. The structure was refined to R = 0.169 and R free = 0.186 at a resolution of 1.87 Å at room temperature. During crystallization the degradative reaction took place, and the electron density in the active site corresponds to the substrate carbamoyl aspartate. Carbamoyl aspartate interacts with the protein in the active site in a manner similar to that observed for Escherichia coli and human dihydroorotases. However, the flexible loop (residues 140–151) adopts both conformations in the crystal, loop-out and loop-in, with the loop-out conformation having higher occupancy. This contrasts with our expectations for the flexible loop to be exclusively in the loop-in conformation, which is the conformation that it adopts to stabilize the binding of the substrate in the known systems. Additional studies with substrate analogs that resemble carbamoyl aspartate and different crystallization conditions would provide further insight into the conformation of the flexible loop in this system.

Methanococcus jannaschii↗

2020 Results for Avian Monitoring at the Technical Area 36 Minie Site, Technical Area 39 Point 6, and Technical Area 16 Burn Ground at Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) biologists in the Environmental Protection and Compliance Division initiated a multi-year program in 2013 to monitor avifauna (birds) at two open detonation sites and one open burn site on LANL property. In this annual report we compare monitoring results from these efforts among years to monitor trends. The objectives of this study are to 1) determine whether LANL operations impact bird species richness, diversity, or abundance and 2) examine occupancy and nest success of secondary-cavity nesting birds using nestboxes. LANL biologists completed the eighth year of this effort in 2020

54 ENVIRONMENTAL SCIENCES↗

Managing Hanford's Direct Feed Low Activity Waste Program - 20002

The Office of River Protection (ORP) is responsible for the management and completion of the River Protection Project (RPP) mission, which comprises both the Hanford Site tank farms operations and the completion and operation of the Waste Treatment and Immobilization Plant Project. The RPP mission is to safely retrieve, treat, and immobilize Hanford's high-level and low-activity tank waste and close the tank farms to protect the Columbia River. The Direct-Feed Low-Activity Waste (DFLAW) Program is a major subset of the overall RPP mission, providing disposition of low-activity waste. The scope is to retrieve, treat, and immobilize the low-activity waste at the Low-Activity Waste Facility. DFLAW will begin operations no later than December 2023. The DFLAW Program overarches a suite of individual projects, activities, and infrastructure upgrades. The major projects and activities include multiple contractors under both ORP and the Richland Operations Office, underscoring the need for effective integration, coordination, and collaboration. The objectives of the DFLAW Program leadership team are to: - Effectively coordinate and integrate the projects that comprise the DFLAW Program - Manage the interfaces between the projects so that the integrated DFLAW Program is completed successfully - Ensure the DFLAW portfolio of projects operate as required without gaps or conflicts at the interfaces. DOE is accomplishing these objectives through a newly established leadership model that integrates the DOE and contractor work streams and promotes a teamwork model to enable collaborative success. Long considered one of the most formidable cleanup challenges at Hanford, the Department of Energy and its contractors are on the verge of achieving a cleanup commitment that has been decades in the making. DOE is preparing to vitrify (turn to glass) Hanford's chemical and radioactive tank waste using the DFLAW process. The Modified Consent Decree milestone for completing hot commissioning of the Hanford Site's Low- Activity Waste Facility is Dec. 31, 2023. While this milestone may seem distant under normal project management circumstances, it is a relatively short period of time for the operational and cultural transformation necessary to successfully begin treating tank waste at Hanford. Direct feed means separating the waste at a tank farm to remove the more radioactive portion (i.e., solids and cesium) so that the resulting low-activity (less radioactive) waste can be fed directly to the Waste Treatment and Immobilization Plant's Low-Activity Waste Facility. Starting DFLAW will require a singular, intensive leadership focus, along with a sustained, collective commitment to excellence and teamwork by the Department and its contractors. Major upgrades to Hanford's infrastructure will occur prior to startup. Supporting DFLAW operations requires significant integration between the DFLAW facilities - the Waste Treatment Plant, Hanford's tank farms, effluent treatment facilities, disposal facilities - and between all of the site contractors to achieve success. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Creb5 controls its own expression and directly induces the joint interzone regulatory program

Prior studies have indicated that the transcription factor Creb5 is expressed in the joint interzone, which contains the progenitors for all synovial joint tissues in both mouse and human embryos. In the absence of Creb5 function, most synovial joint interzones fail to form and the cartilage templates in the long bones remain fused. This earlier work did not clarify whether Creb5 initiates a cascade of signaling molecules, such as growth and differentiation factor 5 (Gdf5) and Wnt-family members, that in turn induce the formation of the joint interzone, or instead directly activates the expression of joint interzone markers. In the present study, an integrative analysis of the transcriptome, chromatin accessibility, and Creb5-occupancy in joint progenitors revealed that Creb5 directly binds to both its own two promoters and to the regulatory regions of Gdf5 and Sfrp2, each of whose expression in the joint interzone is Creb5-dependent. Functional enhancer analysis indicated that Creb5 binding sites in either the two Creb5 promoters, or in Gdf5 and Sfrp2 regulatory elements are necessary for these sequences to drive transgene expression in the developing synovial joints. While Creb5 directly drives Gdf5 and Sfrp2 expression in the inner joint interzone, Creb5 activates Barx1 expression specifically in the outer joint interzone. Our findings indicate that Creb5 initiates a regulatory network that both promotes the formation of synovial joints, and subsequently activates distinct transcriptional targets in the inner versus the outer regions of the joint interzone, thus regionalizing gene expression in the developing joint.

Zhang, Cheng-Hai↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact Noise Monitoring at Site 9940: RD-24 Shots

The purpose of this sampling event was to determine if the observation point (inside the MFCP) could be relocated from 74 feet away to 21 feet from ground zero and to determine how much attenuation is provided by the MFCP. The MFCP provides noise attenuation to ensure Members of the Workforce (MOW) exposure to impact noise is below the Occupational Exposure Limit (OEL) of 140 dBC. The MFCP will be used for future tests under similar configurations. Please note that during each test shot, MOW was located inside MFCP that was 74 feet from ground zero and donned hearing protection (e.g., ear plugs with a minimum noise reduction rating of 23).

42 ENGINEERING↗

Challenges of space medical operations and life sciences management

The Kennedy Space Center (KSC) has been the premier launch and landing site for America's space program since the early 1960s. Visitors are cognizant of space vehicles, processing facilities and launch pads which are treasured national resources. However, most are unaware of the unique organization which supports launch and landing activities and manages the center's occupational medicine, environmental health, ecological and environmental monitoring functions, as well as human and plant research programs. Management of this multifaceted organization can be complex because funding its different functions comes from a number of sources. Additionally the diverse disciplines of personnel present a special challenge in maintaining professional competencies while assuring efficiency in cyclical operations. This article explains the organization's structure and reviews some of its accomplishments.

Haddad, S. G.↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Challenges and Opportunities Specific to Microreactors: Compact and Light-Weight Shielding During Operation and Transportation

The problem of designing a shield for a mobile microreactor has been addressed. The principal challenges encountered in this endeavor are the dual goals of increasing radiation protection and decreasing weight. It is recognized that these two goals are contradictory. Increasing shielding naturally increases weight. Conversely, decreasing weight naturally calls for decreasing material inventory, including possibly decreasing shield mass. The operational and regulatory drivers for shielding and transportation constraints are identified and summarized. The main constraints pertain to volume, mass, radiation dose, material feasibility and availability, and decommissioning expectations. The latter are limits on residual contamination and dose rates after the reactor is removed. Progress toward solving the challenge of shielding a transportable microreactor is made by considering a tungsten tetraboride (WB4) shell surrounding the reactor vessel. The shield and a generic microreactor were modeled using the MCNP code. It was determined that the presence of a 16-cm-thick WB4 shield reduces the dose equivalent rate during operations to 3.6 mrem/h just outside of a concrete vault and dome and soil berm surrounding the reactor, which is very near the occupational dose rate limits. Without the WB4 layer, the dose rate at the same location outside the berm would be 120 mrem/h. Most importantly, the presence of the WB4 shield substantially protects the surrounding concrete and soil from activation, thus decreasing the duration of administrative control for the site following removal of the reactor from 16 to 3.4 years. At that point, the site may be decommissioned and returned to unrestricted public access. A limitation on the incorporation of a WB4 shield as an intrinsic component of a microreactor is that it results in a design that is transportable only by using the largest road conveyances and that the load would require special permits for transit through the U.S. highway system. New directions for further improvements and possibly more effective solutions to the shielding problem of a mobile microreactor are discussed in the conclusion section.

Microreactor↗

Extending the Gutzwiller approximation to intersite interactions

In this work, we develop an extension of the Gutzwiller approximation (GA) formalism that includes the effects of Coulomb interactions of arbitrary range (including density density, exchange, pair hopping, and Coulomb-assisted hopping terms). This formalism reduces to the ordinary GA formalism for the multiband Hubbard models in the presence of only local interactions. This is accomplished by combining the 1 / z expansion—where z is the coordination number, and only the leading-order terms contribute in the limit of infinite dimensions—with a P R † P R - I expansion, where P R is the Gutzwiller projector on the site R . Furthermore, the method is conveniently formulated in terms of a Gutzwiller Lagrange function. We apply our theory to the extended single-band Hubbard model. Similarly to the usual Brinkman-Rice mechanism, we find a Mott transition. A valence skipping transition is observed, where the occupation of the empty and doubly occupied states for the Gutzwiller wave function is enhanced with respect to the uncorrelated Slater determinant wave function.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

KSC Headquarters Building Area SWMU 104 Soil Interim Measure Report for LOC 2D and LOC 2E Kennedy Space Center, Florida

This Interim Measure (IM) Report for Location of Concern (LOC) 2D and LOC 2E summarizes the activities associated with implementation of an IM to address soil and concrete contamination at the Kennedy Space Center (KSC) Headquarters Building Area (KHQA) located at KSC, Florida. KHQA has been designated Solid Waste Management Unit (SWMU) 104 under KSC’s Resource Conservation and Recovery Act Corrective Action Program. The IM consisted of excavating/removing residual polychlorinated biphenyl (PCB) contamination in soil and concrete from two separate areas, LOC 2D and LOC 2E, which were associated with electrical transformer locations. IM activities were conducted in accordance with the Interim Measure Work Plan (IMWP), Revision 1, for KHQA dated June 2018, which was approved by the Florida Department of Environmental Protection in a correspondence letter dated April 2016 and the United States Environmental Protection Agency in a correspondence letter dated August 2018. The objective of the IM was to remove all remaining contaminated media with total PCB concentrations greater than the State of Florida Residential Soil Cleanup Target Level (RSCTL) (0.5 milligrams per kilogram [mg/kg]). This cleanup goal meets unrestrictive re-use conditions in Florida, and is below federal regulations for PCB Bulk Remediation Waste Cleanup of 1 mg/kg for high occupancy, unrestricted use areas, as outlined in 40 Code of Federal Regulations (CFR) 761.61(a). The timeline of the IM was coordinated with demolition of the former KSC Headquarters Building (demolished in 2021) in order to safely remove contaminated media after electrical equipment was de-energized and removed from the site. Excavation activities were conducted between January 10, 2022, and February 8, 2022, and included two waste streams for off-site disposal: (1) PCB-remediation waste greater than or equal to 50 mg/kg, and (2) PCB-remediation waste less than 50 mg/kg. A total of approximately 347 cubic yards (478 tons) of PCB-contaminated soil and concrete was initially removed from the LOC 2D and LOC 2E areas, as defined in the IMWP. An additional 4.35 tons of soil and concrete were removed based on verification sampling, which was conducted until the cleanup goal was achieved. The total area of excavation from both LOC 2D and LOC 2E was approximately 5,186 square feet (0.12 acres), and excavation depths ranged from 0.5 to 4.0 feet below land surface Excavated soils and concrete were stockpiled based on waste stream and subsequently transported and disposed of at Waste Connections of Osceola County, LLC – JED Landfill in St. Cloud, Florida (PCBs less than 50 mg/kg) or the Chemical Waste Management Landfill in Emelle, Alabama (PCBs greater than or equal to 50 mg/kg). Following excavation, clean backfill was brought to the site and provided to the Demolition Contractor to complete backfill and grading in conjunction with their final site restoration activities from building demolition. Post-IM groundwater sampling was conducted in May 2022 at three monitoring wells installed in April 2022 to confirm that PCBs did not leach into groundwater. These wells were installed where the highest PCB concentrations were detected at LOC 2D, LOC 2E, and from the Building Perimeter IM (previously completed in 2020). All PCB results in groundwater were non-detect. Volatile organic compounds were also analyzed based on potential past use of solvents in transformers with PCB-dielectric fluids and the potential release of dielectric fluids containing volatile organic compounds, and all results were non-detect. Based on completion of a successful IM at LOC 2D and LOC 2E, as well as previous remedial actions that have addressed other contamination at KHQA (SWMU 104), No Further Action without controls will be recommended for SWMU 104. NASA will submit separate Site Rehabilitation Completion Order request documentation for SWMU 104 to support an NFA without controls recommendation.

PCB↗

A Rapid Population Assessment Method for Wild Pigs Using Baited Cameras at 3 Study Sites

ABSTRACT Reliable and efficient population estimates are a critical need for effective management of invasive wild pigs ( Sus scrofa ). We evaluated the use of 10‐day camera grids for rapid population assessment (RPA) of wild pigs at 3 study sites that varied in vegetation communities and wild pig densities. Study areas included Buck Island Ranch, Florida; Tejon Ranch, California; and the Savannah River Site, South Carolina, USA, during 2016–2018. Rapid population assessments grids were composed of baited camera traps spaced approximately 500 or 750 m apart. Two RPA grids were deployed per study site and each grid was deployed twice (4–6 months apart) to assess changes in response to season or population control efforts. We assessed the ability of RPA grids to track population trends, how camera number influenced estimate precision, and how relative abundance indices related to density estimates. We detected changes in occupancy probability, detection probability, and N‐mixture estimates following removal operations and between seasons, but the ability of RPA grids to track population trends was dependent on the statistical method used and number of cameras traps. Increasing the number of cameras traps used in RPA grids increased precision, and these results can be used in determining survey design and estimate choice. We found that estimates of occupancy probability, detection probability, and N‐mixture estimates were positively correlated with spatially explicit capture–recapture density estimates. Thus, these less labor‐intensive estimates from RPA grids showed potential to index the relative abundance of wild pigs in some systems. Our evaluation of RPAs indicates that using study‐specific combinations of statistical method and number of cameras can provide a useful tool for monitoring wild pig presence, tracking population trends, and evaluating the effectiveness of management actions. © 2020 The Wildlife Society.

Schlichting, Peter E.↗

TA-03-0016 Ion Beam Facility D&D: Sphere of Influence [Slides]

TA-03-0016 Ion Beam Facility: This structure is 70 years old and has been vacant since 1994 and was excessed in 1999. The Ion Beam Facility (IBF) was built in 1953 to support essential post-World War II scientific research and houses LANL's original vertical and tandem Van de Graaff accelerators. The vertical Van de Graaff accelerator was built under the direction of Joseph McKibben from 1948 to 1952 and was used for applied nuclear physics experiments. The Ion Beam facility is considered by NNSA as one of its highest risk process contaminated facilities within the complex. Ion Beam is a radiological facility adjacent to the LANL Occupational Medicine Facility on the south side of TA-3, the most populated technical area at LANL. It poses an undesirable fire risk, especially given its close location to a rugged wooded canyon and difficulties in fighting a wildland fire in such a location. Demolition of this structure will provide a constructable site for critical mission radiological laboratory spaces.

99 GENERAL AND MISCELLANEOUS↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗