Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

The NASA Tournament Laboratory (NTL): Improving Data Access at PDS while Spreading Joy and Engaging Students through 16 Micro-Contests

NASA PDS hosts terabytes of valuable data from hundreds of data sources and spans decades of research. Data is stored on flat-file systems regulated through careful meta dictionaries. PDS's data is available to the public through its website which supports data searches through drill-down navigation. While the system returns data quickly, result sets in response to identical input differ depending on the drill-down path a user follows. To correct this Issue, to allow custom searching, and to improve general accessibility, PDS sought to create a new data structure and API, and to use them to build applications that are a joy to use and showcase the value of the data to students, teachers and citizens. PDS engaged TopCoder and Harvard Business School through the NTL to pursue these objectives in a pilot effort. Scope was limited to Small Bodies Node data. NTL analyzed data, proposed a solution, and implemented it through a series of micro-contests. Contest focused on different segments of the problem; conceptualization, architectural design, implementation, testing, etc. To demonstrate the utility of the completed solution, NTL developed web-based and mobile applications that can compare targets, regardless of mission. To further explore the potential of the solution NTL hosted "Mash-up" challenges that integrated the API with other publically available assets, to produce consumer and teaching applications, including an Augmented Reality iPad tool. Two contests were also posted to middle and high school students via the NoNameSite.com platform, and as a result of these contests, PDS/SBN has initiated a Facebook program. These contests defined and implemented a data warehouse with the necessary migration tools to transform legacy data, produced a public web interface for the new search, developed a public API, and produced four mobile applications that we expect to appeal to users both within and, without the academic community.

LaMora, Andy↗

Star sensor/mapper with a self deployable, high-attenuation light shade for SAS-B

A star sensor/mapper to determine positional data for the small astronomy satellites was tested to detect stars of plus 4 visual magnitude. It utilizes two information channels with memory so that it can be used with a low-data-rate telemetry system. One channel yields star amplitude information; the other yields the time of star occurrence as the star passes across an N-slit reticle/photomultiplier detector system. Some of the features of the star sensor/mapper are its low weight of 6.5 pounds, low power consumption of 0.4 watt, bandwidth switching to match the satellite spin rate, optical equalization of sensitivity over the 5-by-10 deg field of view, and self-deployable sunshade. The attitude determination accuracy is 3 arc minutes. This is determined by such parameters as the reticle configuration, optical train, and telemetry readout. The optical and electronic design of the star sensor/mapper, its expansion capabilities, and its features are discussed.

Schenkel, F. W.↗

A simple Fourier analysis technique for measuring the dynamic response of manual control systems.

From a practical standpoint most dynamic response analysis techniques are complicated, expensive, and time consuming to mechanize and operate. Adaptive parameter tracking techniques partially overcome these faults, but they have prescribed forms which is an undesirable restriction for basic research. To overcome these drawbacks, an on-line Fourier analysis technique has been developed which deals only with the input and error signals in a manual feedback control system. Several sine waves are used for the input, and the on-line data measurement includes the error variance and a simple means for obtaining the sine and cosine transforms of the error signal at each of the input frequencies. From this relatively small amount of data, we show simple ways to compute the open- and closed-loop dynamic response at input frequencies and the relative amount of linearly correlated power in the error signal.

Allen, R. W.↗

Identification of Geostructures of the Continental Crust Particularly as They Relate to Mineral Resource Evaluation

The author has identified the following significant results. A pattern of very old geostructures was recognized, reflecting structures in the crust. This pattern is not peculiar to Alaska, but can be recognized throughout the northern cordillera. A new metallogenic hypothesis for Alaska was developed, based on the relationship of space image linears to known mineral deposits. Using image linear analysis, regional geologic features were also recognized; these features may be used to guide in the location of undiscovered oil and/or gas accumulations in northern Alaska. The effectiveness of ERTS data in enhancing medium and small scale mapping was demonstrated. ERTS data were also used to recognize and monitor the state of large scale vehicular scars on Arctic tundra.

Lathram, E. H.↗

WMAP Detection of Early Reionization

The Wilkinson Microwave Anisotropy Probe (WMAP) has mapped the full sky in Stokes I, Q, and U parameters at frequencies 23, 33, 41, 61, and 94 GHz. We detect correlations between the temperature and polarization maps significant at more than 10 standard deviations. The correlations are inconsistent with instrument noise and are significantly larger than the upper limits established for potential systenatic errors. The correlations are present in all WMAP frequency bands with similar amplitude from 23 to 94 GHz, and are consistent with a superposition of a CMB signal with a weak foreground. The fitted CMB component is robust against different data combinations and fitting techniques. On small angular scales the WMAP data show the temperature-polarization correlation expected from adiabatic density perturbations. The data for $\ell > 20$ agree well with the signal predicted solely from the temperature power spectra, with no additional free parameters. The existence of correlations on super-horizon scales provides significant support for inflationary cosmologies. We detect excess power on large angular scales compared to predictions based on the temperature power spectra alone. The excess power is well described by reionization at redshift $11 < z < 30$ at 95\% confidence. A model-independent fit to reionization optical depth yields results consistent with the best-fit $\Lambda$CDM model, with best fit value $\tau = 0.17 \pm 0.04$ at 68\% confidence, including systematic and foreground uncertainties. This value is larger than expected given the detection of a Gunn-Peterson trough in the absorption spectra of distant quasars, and implies that the universe has a complex ionization history. I will discuss the WMAP data and its implications for reionization in the early universe.

Kogut, A.↗

WMAP Detection of Early Reionization

The Wilkinson Microwave Anisotropy Probe (WMAP) has mapped the full sky in Stokes I, Q, and U parameters at frequencies 23, 33, 41, 61, and 94 GHz. We detect correlations between the temperature and polarization maps significant at more than 10 standard deviations. The correlations are inconsistent with instrument noise and are significantly larger than the upper limits established for potential systematic errors. The correlations are present in all WMAP frequency bands with similar amplitude from 23 to 94 GHz, and are consistent with a superposition of a CMB signal with a weak foreground. The fitted CMB component is robust against different data combinations and fitting techniques. On small angular scales the WMAP data show the temperature-polarization correlation expected from adiabatic density perturbations. The data for $\ell > 20$ agree well with the signal predicted solely from the temperature power spectra, with no additional free parameters. The existence of correlations on super-horizon scales provides significant support for inflationary cosmologies. We detect excess power on large angular scales compared to predictions based on the temperature power spectra alone. The excess power is well described by reionization at redshift $11 < z < 30$ at 95\% confidence. A model-independent fit to reionization optical depth yields results consistent with the best-fit $\Lambda$CDM model, with best fit value $\tau = 0.17 \pm 0.04$ at 68\% confidence, including systematic and foreground uncertainties. This trough in the absorption spectra of distant quasars, and implies that the universe has a complex ionization history. I will discuss the WMAP data and its implications for reionization in the early universe.

Kogut, A.↗

Small-Satellite Mission Failure Rates

The purpose of this report is to determine the failure rate of small-satellite missions launched between the years 2000 and 2016. This analysis considers the rates of both partial and total mission failure, as well as the failures attributable to failure of the launch vehicle. This study observed that between the years of 2000 to 2016, 41.3% of all small satellites launched failed or partially failed. Of these small satellite missions, 24.2% were total mission failures, another 11% were partial mission failures, and 6.1% were launch vehicle failures. The small satellite failure data reveals an increase in the failure rate as the yearly launch rate has increased. The period 2000 to 2008 averaged 15 launches per year, during which 28.6% of the small satellite missions failed or partially failed. The period from 2009 to 2016 averaged 48 launches per year, during which 42.6% of the small satellite missions failed or partially failed. The launch vehicle failure rate for both periods was the same at around 6.1%. The implication is that for modern small satellite missions, almost one out of every two small satellite missions will result in either a total or a partial mission failure. Counting the partial mission successes as “successful missions” reduces the failure rate, but only to 38.2% for the period 2009 to 2016.

Small Satellite↗

Numerical Simulation of No Vent Chill and Fill of a Large Liquid Hydrogen Tank

On orbit transfer of cryogenic liquids is necessary for many future space missions. The techniques required to transfer cryogens in micro gravity are quite different from ground system applications. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor generated due to heat transfer from warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. If the normal gravity technique is used on orbit, the uncertainty of liquid and vapor distributions in unsettled condition may result in dumping of large amounts of liquid propellant overboard. The Vented Chill and No Vent Fill (VCNVF) process is a methodology [1] used to reduce propellant loss by holding the vent valve open during initial wall chilldown, preventing over-pressurization of the tank and stalling of the incoming flow, but closing the tank vent valve after chilling the tank wall sufficiently. An accurate simulation of no vent tank chill and fill is necessary to estimate the amount of propellant necessary to chill the tank, determine the maximum sustainable flowrate to fill the tank without stalling, and establish a timeline for the filling process. Numerical modeling of filling a cryogenic tank is complex because the flow is two-phase and the process involves both boiling and condensation with heat transfer between solid and fluid. In recent years, progress has been made to develop a numerical modeling technique [2,3,4] that has been verified by comparing with the test data from a small flight tank using liquid nitrogen [5]. The purpose of the present paper is to apply this technique in a larger tank with liquid hydrogen and compare with the test data of Chato [1]. The K-site Test Facility [1], shown in Figure 1, consists of a Test Tank, spray system, instrumentation, and the vacuum chamber. The test tank selected was ellipsoidal with an 87 inch major diameter and a 1.2 to 1 major to minor axis ratio. The two ends are joined by a short 1.5 inch cylindrical section. The tank is made of 2219 aluminum chemically milled to a nominal thickness of 0.087 inches. The tank weighs 329.25 pounds, and the tank volume is 175 ft 3 . The GFSSP model of the Test Tank is shown in Figure 2. Node 13 is a boundary node that represents the supply tank which is supplying liquid hydrogen at a given pressure and temperature. The total measured flowrate is evenly distributed through Branches 131 through 139. Nodes 1 through 9 represent the test tank and they are connected with metal solid nodes 14 through 22 through fluid-to-solid conductors that allow convective heat transfer between the solid and fluid nodes. The predicted tank pressure, filling rate, wall temperature and fluid temperature will be compared with test data.

Alok Majumdar↗

Analysis of small crack behavior for airframe applications

The small fatigue crack problem is critically reviewed from the perspective of airframe applications. Different types of small cracks-microstructural, mechanical, and chemical-are carefully defined and relevant mechanisms identified. Appropriate analysis techniques, including both rigorous scientific and practical engineering treatments, are briefly described. Important materials data issues are addressed, including increased scatter in small crack data and recommended small crack test methods. Key problems requiring further study are highlighted.

Mcclung, R. C.↗

Remote Sensing Application to Land Use Classification in a Rapidly Changing Agricultural/Urban Area: City of Virginia Beach, Virginia

Remote sensing data on computer-compatible tapes of LANDSAT 1 multispectral scanner imager were analyzed to generate a land use map of the City of Virginia Beach. All four bands were used in both the supervised and unsupervised approaches with the LAYSYS software system. Color IR imagery of a U-2 flight of the same area was also digitized and two sample areas were analyzed via the unsupervised approach. The relationships between the mapped land use and the soils of the area were investigated. A land use land cover map at a scale of 1:24,000 was obtained from the supervised analysis of LANDSAT 1 data. It was concluded that machine analysis of remote sensing data to produce land use maps was feasible; that the LAYSYS software system was usable for this purpose; and that the machine analysis was capable of extracting detailed information from the relatively small scale LANDSAT data in a much shorter time without compromising accuracy.

Odenyo, V. A. O.↗

A feasibility study for measuring stratospheric turbulence using metrac positioning system

The feasibility of obtaining measurements of Lagrangian turbulence at stratospheric altitudes is demonstrated by using the METRAC System to track constant-level balloons. The basis for current estimates of diffusion coefficients are reviewed and it is pointed out that insufficient data is available upon which to base reliable estimates of vertical diffusion coefficients. It is concluded that diffusion coefficients could be directly obtained from Lagrangian turbulence measurements. The METRAC balloon tracking system is shown to possess the necessary precision in order to resolve the response of constant-level balloons to turbulence at stratospheric altitudes. A small sample of data recorded from a tropospheric tetroon flight tracked by the METRAC System is analyzed to obtain estimates of small-scale three-dimensional diffusion coefficients. It is recommended that this technique be employed to establish a climatology of diffusion coefficients and to ascertain the variation of these coefficients with altitude, season, and latitude.

Gage, K. S.↗

Review of current interest and research in water hyacinth-based wastewater treatment

The status of activity in the user community for water hyacinth-based wastewater treatment was evaluated. The principal technique used was that of interviewing people who either (1) were known to be engaged in hyacinth research or development or (2) had made inquiry to NASA about hyacinth systems. About 40 non-research organizations and a similar number of research organizations were contacted. As a result of the interviews and a review of the relevant literature, it was concluded that hyacinth systems have the potential for providing a lower cost way for small cities to meet increasingly stringent effluent requirements. A limited amount of full-scale demonstration of hyacinth systems has been carried out during the past two years, but the yield of design data has been small. Several organizations are currently planning construction of experimental full-scale hyacinth-based wastewater treatment systems during 1977-1978.

Markarian, R. K.↗

Estimation of Longitudinal Unsteady Aerodynamics of a Wing-Tail Combination From Wind Tunnel Data

This paper presents an initial step toward model identification from wind tunnel data for an airliner configuration. Two approaches to modeling a transport configuration are considered and applied to both steady and large-amplitude forced-oscillation wind tunnel data taken over a wide range of angles of attack. Only limited conclusions could be drawn from this initial data set. Although model estimated time histories of normal force and pitching moment agree reasonably well with the corresponding measured values, model damping parameters did not, for some cases, have values consistent with small amplitude oscillatory data. In addition, large parameter standard errors implied poor information content for model structure determination and parameter estimation. Further investigation of the modeling problem for more general aerodynamic models is recommended with close attention to experiment design for obtaining parameters with high accuracy.

Murphy, Patrick C.↗

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

Data analysis of the LPSP experiment on OSO-8

The first and statistically most reliable step in the data analysis - the computation of the vertical phase lag between photospheric and chromospheric oscillations - was completed. Unfortunately, the error associated with this calculated phase lag is so great that the result has no physical significance. Since the subsequent data analysis that was originally planned would have much larger associated errors, it was concluded that the data available is insufficient to allow any meaningful results to be derived. Accordingly, the project was terminated. The reasons for the failure of the data are discussed. There are two basic reasons for this failure; (1) the very low signal to noise ratio of the raw data, and (1) the small statistical sample that resulted from the very small number of usable orbits. The final phase of data analysis is described. Finally, some comments and recommendations of a general nature are made concerning this entire contract effort. It is hoped that at least some lessons can be learned from this particular Guest Investigator project, so that future Guest Investigator programs can be pursued more effectively, and with less risk.

Frazier, E. N.↗

The dependence of the CO2 removal efficiency of LiOH on humidity and mesh size

The effect of humidity on the CO2 removal efficiency of small beds of anhydrous LiOH has been studied. Experimental data taken in this small bed system clearly show that there is an optimum humidity for beds loaded with LiOH from a single lot. The CO2 efficiency falls rapidly under dry conditions, but this behavior is approximately the same in all samples. The behavior of the bed under wet conditions is quite dependent on material size distribution. The presence of large particles in a sample can lead to rapid fall off in the CO2 efficiency as the humidity increases.

Davis, S. H.↗