Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advanced solid state sensor system for remote sensing from satellite

Discussion of approaches to providing the needed performance improvement in solid state sensor systems for remote sensing from future resources surveying satellites. An advanced breadboard line array imaging system using long detector arrays from a number of small chips has been built. Test results and typical imagery produced by the breadboard system demonstrate the capabilities of solid state imager technology.

Thompson, L. L.↗

Failure Detector for Power-Factor Controller

New protective circuits have been developed for power-factor ac motor controllers. Circuits prevent direct current and consequent motor heating that would normally result from failure of solid-state switch in controller. Single-phase power-factor controller with short detector compensates for short-circuit failure in either direction by applying full power to motor. Controller with open detector compensates for open-circuit failure in either direction by turning off power to motor.

Nola, F. J.↗

Operational processing and cloud boundary detection from micro pulse lidar data

Micro Pulse Lidar (MPL) was developed at NASA Goddard Space Flight Center (GSFC) as the result of research on space-borne lidar techniques. It was designed to provide continuous, unattended observations of all significant atmospheric cloud and aerosol structure with a rugged, compact system design and the benefit of eye safety (Spinhirne 1993). The significant eye safety feature is achieved by using low pulse energies and high pulse repetition rates compared to standard lidar systems. MPL systems use a diode pumped 10 microj, 2500 Hz doubled Nd:YLF laser. In addition, a solid state Geiger mode avalanche photo diode (GAPD) photon counting detector is used allowing for quantum efficiencies approaching 70%. Other design features have previously been noted by Spinhirne (1995). Though a commercially available instrument, with nearly 20 systems operating around the world, the most extensive MPL work has come from those operated by the Atmospheric Radiation Measurement (ARM) (Stokes and Schwartz 1994) program. The diverse ability of the instrument relating to the measurement of basic cloud macrophysical structure and both cloud and aerosol radiative properties well suits the ARM research philosophy. MPL data can be used to yield many parameters including cloud boundary heights to the limit of signal attenuation, cloud scattering cross sections and optical thicknesses, planetary boundary layer heights and aerosol scattering profiles, including those into the stratosphere in nighttime cases (Hlavka et al 1996). System vertical resolution ranges from 30 m to 300 m (i.e. high and low resolution respectively) depending on system design. The lidar research group at GSFC plays an advisory role in the operation, calibration and maintenance of NASA and ARM owned MPL systems. Over the past three years, processing software and system correction techniques have been developed in anticipation of the increasing population of systems amongst the community. Datasets produced by three ARM-owned systems have served as the basis for this development. With two operating at the southern Great Plains Cloud and Radiation Testbed Site (SGP CART) since December 1993 and another at the Manus Island Atmospheric Radiation and Cloud Station (TWP ARCS) location in the tropical western Pacific since February 1997, the ARM archive contains over 4 years of observations. In addition, high resolution systems planning to come on-line at the North Slope, AK CART shortly with another scheduled to follow at the TWP ARCS-II will diversify this archive with more extensive observations.

Campbell, James R.↗

Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.

Gronoff, Guilluame↗

Ultrastable reference pulser for high-resolution spectrometers

Solid-state double-pulse generator for a high resolution semiconductor detector meets specific requirements for resolution /0.05 percent/, amplitude range /0.1-13 MeV/, and repetition rate /0.1-1000 pulses per second/. A tag pulse is generated in coincidence with each reference pulse.

Brenner, R.↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

Besser, P. J.↗

Sensors and detectors in NASA's future missions

Advances in electronics are responsible for major improvements in NASA's sensing and detection capabilities for future space missions. Technologies such as charge-transfer devices, tunable diode lasers, millimeter and submillimeter wave solid-state receiver components, large-scale circuit integration, new electronic materials and processing techniques, and novel detector electronics are contributing to the goal of a tenfold increase in the capacity of data collection from future platforms and will be used for space exploration and utilization.

Rubin, B.↗

The Goddard Space Flight Center Solid State Spectrometer for the HEAO-B Mission

A non-dispersive, cryogenically-cooled X-ray detector system, to be flown as one of the focal-plane experiments on the High Energy Astrophysical Observatory-B, is described. The instrument is designed to measure the X-ray flux in the 500 eV to 5000 eV range with an energy resolution of 150 eV (pulser) and a temporal resolution approaching 2 microsec.

Joyce, R. M.↗

Characterization of the RaD-X Mission Instruments

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. To properly interpret the measurements, it is necessary to evaluate how the payload affects the radiation environment of the detectors. In addition, it is necessary to evaluate how the detectors react to the different particles impacting them. We present the results of the Geant-4 simulations of the interaction of the different radiations with the payload and the instruments. We show how it affect the measurements, and which instruments are better suited for future missions

Gronoff, Guillaume↗

Microchannel detector array for X-rays and UV

Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.

Timothy, J. G.↗

New processes and materials for ultraviolet detection with solid state devices

The three major effects that degrade external responsivity of silicon from the 1/lambda theoretical curve for a quantum detector are: surface reflectance, surface recombination, and junction depth. Since the p-n junction must be very shallow, problems relating to surface are further enhanced. MOS type of processing is necessary. HCl oxides and numerous acid clean-ups are utilized in order to obtain a contamination free surface with low Qss levels. Stringent process controls such as CV shifts, spreading resistance measurements, thickness monitoring etc., are used to analyze the surface contaminations, surface mobile charges, surface concentrations, junction depth, oxide thickness etc. Low surface concentrations of 10 to the 18th atoms/cu cm are achieved by low temperature boron nitride depositions. Shallow junction depths of the order of a few tenths of a micron are achieved by low temperature controlled diffusions. In order to improve breakdown characteristics of these shallow junction devices, field plate and deep diffused p(+) ring geometries are used.

Chopra, D.↗

The X-ray pulsars 4U 1145-61 and 1E 1145.1-6141

Observations of the neighboring X-ray pulsars 4U 1145-61 and 1E 1145.1-6141 obtained by OSO 8, HEAO 1 and the Einstein Observatory between 1975 and 1979 are reported. A temporal analysis of Einstein Solid State Spectrometer and Monitor Proportional Counter data, OSO 8 A and C detector data and HEAO 1 A-2(3) experiment data confirms the presence of two periodicites at 291 and 297 sec in the region, with the shorter period located within 3 arcmin of 4U 1145-61. Observations indicate the spectrum of 4U 1145-61 to obey a power law with an index of 1.5 out to at least 60 keV, with little variation with pulse phase, and a 500-eV EW iron line at 6.7 keV. The spectrum of the other source is found to be more absorbed. Similarities between the pulsars are noted, and it is suggested that they may be the result of pulsar formation in a homogeneous cloud of progenitors.

White, N. E.↗

Hard X-ray properties of cataclysmic variables

A brief summary is presented of results for AM Her, EX Hya, SS Cyg, and U Gem obtained with the high-energy detectors of the HEAO A2 experiment from 2-60 keV and the Solid State Spectrometer Experiment with the Monitor Proportional Control on the Einstein Observatory. It is found that the magnetic variable AM Her and the dwarf novae are similar in having bremsstrahlung of similar luminosity with temperatures for the dwarf novae that can approach that for AM Her and in flickering on a time scale of 5-15 min. But in general these dwarf novae temperatures are about 2-10 times lower. Only in Am Her is there evidence in the spectrum and eclipses for a small spot very close to the white dwarf surface. Most of the hard X-rays in SS Cyg, EX Hya, and U Gem are not pulsed, and the hard X-ray fluxes observed have never been significantly absorbed or degraded.

Swank, J. H.↗

Growth of mercuric iodide (HgI2) for nuclear radiation detectors

Mercuric iodide is a material used for the fabrication of the sensing element in solid state X-ray and gamma ray detecting instruments. The operation of the devices is determined to a large degree by the density of structural defects in the single crystalline material used in the sensing element. Since there were strong indications that the quality of the material was degraded by the effects of gravity during the growth process, a research and engineering program was initiated to grow one or more crystals of mercuric iodide in the reduced gravity environment of space. A special furnace assembly was designed which could be accommodated in a Spacelab rack, and at the same time made it possible to use the same growth procedures and controls used when growing a crystal on the ground. The space crystal, after the flight, was subjected to the same evaluation methods used for earth-grown crystals, so that comparisons could be made.

Vandenberg, L.↗

Carbon-Nanotube Schottky Diodes

Schottky diodes based on semiconducting single-walled carbon nanotubes are being developed as essential components of the next generation of submillimeter-wave sensors and sources. Initial performance predictions have shown that the performance characteristics of these devices can exceed those of the state-of-the-art solid-state Schottky diodes that have been the components of choice for room-temperature submillimeter-wave sensors for more than 50 years. For state-of-the-art Schottky diodes used as detectors at frequencies above a few hundred gigahertz, the inherent parasitic capacitances associated with their semiconductor junction areas and the resistances associated with low electron mobilities limit achievable sensitivity. The performance of such a detector falls off approximately exponentially with frequency above 500 GHz. Moreover, when used as frequency multipliers for generating signals, state-of-the-art solid-state Schottky diodes exhibit extremely low efficiencies, generally putting out only micro-watts of power at frequencies up to 1.5 THz. The shortcomings of the state-of-the-art solid-state Schottky diodes can be overcome by exploiting the unique electronic properties of semiconducting carbon nanotubes. A single-walled carbon nanotube can be metallic or semiconducting, depending on its chirality, and exhibits high electron mobility (recently reported to be approx.= 2x10(exp 5)sq cm/V-s) and low parasitic capacitance. Because of the narrowness of nanotubes, Schottky diodes based on carbon nanotubes have ultra-small junction areas (of the order of a few square nanometers) and consequent junction capacitances of the order of 10(exp -18) F, which translates to cutoff frequency >5 THz. Because the turn-on power levels of these devices are very low (of the order of nano-watts), the input power levels needed for pumping local oscillators containing these devices should be lower than those needed for local oscillators containing state-of-the-art solid-state Schottky diodes.

Manohara, Harish↗

Increasing the response of PIN photodiodes to the ultraviolet

Solid state device uses sapphire windows and avoids coatings which absorb ultraviolet radiation and ultimately alter detector geometry. Ultimate solution for ultraviolet response is geometry with maximum peripheral area and horizontal field structure to draw out photon induced current carriers.

Burrous, C. N.↗

OAST Space Theme Workshop. Volume 3: Working group summary. 3: Sensors (E-3). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2). D. Additional assessment

Developments required to support the space power, SETI, solar system exploration and global services programs are identified. Instrumentation and calibration sensors (rather than scientific) are needed for the space power system. Highly sophisticated receivers for narrowband detection of microwave sensors and sensors for automated stellar cataloging to provide a mapping data base for SETI are needed. Various phases of solar system exploration require large area solid state imaging arrays from UV to IR; a long focal plane telescope; high energy particle detectors; advanced spectrometers; a gravitometer; and atmospheric distanalyzer; sensors for penetrometers; in-situ sensors for surface chemical analysis, life detection, spectroscopic and microscopic analyses of surface soils, and for meteorological measurements. Active and passive multiapplication sensors, advanced multispectral scanners with improved resolution in the UV and IR ranges, and laser techniques for advanced probing and oceanographic characterization will enhance for global services.

Source record↗