Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Bioleaching ion-unexchangeable rare earth in ion-adsorption type rare earth waste tailing

Ion-adsorption type rare earth ores (IREO) in China serve as the primary source of medium and heavy rare earth globally. With the rapidly growing demand for rare earth elements (REEs) and the dwindling supply of premium IREO, enhancing the recovery of REEs, especially the ion-unexchangeable REEs with ultra-low content and ambiguous speciation from IREO or its tailing, has become a critical trend and challenge. Here, this study identified the occurrences of ion-unexchangeable REEs, primarily detected in Fe-enriched minerals, xenotime, and monazite of IREO using TESCAN integrated mineral analyzer (TIMA) and laser ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) analysis. To extract these elusive REEs, a bioleaching technique utilizing Aspergillus niger (A. niger) metabolites was proposed, achieving a leaching yield of 31.4 wt%. Complementary sequential chemical extraction methods (SCEM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) calculations further elucidate the underlying mechanism, involving the carboxylic acid produced by the metabolic process of microbes that dissolves goethite by disrupting Fe—O bonds and liberating REEs, which complexed with carboxylate (R—COO—), to promote further dissolution. This work offers insight into enhancing the recovery of ion-unexchangeable REEs from IREO or its tailing, paving the way for sustainable and efficient rare earth mining practices.

42 ENGINEERING↗

Developing a new ethylene glycol/H 2 O pretreatment system to achieve efficient enzymatic hydrolysis of sugarcane bagasse cellulose and recover highly active lignin: Countercurrent extraction

Improving pretreatment efficiency is a critical premise in achieving efficient biomass conversion, and obtaining high-performance natural polymers is the guarantee of high-value conversion of biomass. Here, in this study, a new pilot-scale continuous countercurrent pretreatment reaction unit about ethylene glycol-alkali solution was designed for pretreating sugarcane bagasse in order to achieve efficient separation of the three major components of lignocellulose when expanding the scale of pretreatment, reduce lignin deposition on the fiber surface, and obtain highly active lignin and excellent enzymatic hydrolysis efficiency of cellulose. X-ray diffractometer (XRD), X-ray photoelectron spectrometer (XPS), brunauer-emmett-teller (BET) and scanning electron microscope (SEM) methods are used to analyze the structural properties of sugarcane bagasse before and after pretreatment, and high-performance liquid chromatography (HPLC) is used to analyze the monosaccharide components in the enzymatic solution. In addition, the structural properties of the recovered lignin are analyzed by gel permeation chromatography (GPC), 31 P NMR and 2D-HSQC-NMR methods. The results indicate that the system can gain a high cellulose recovery of 92.99% along with a lignin removal of 95.33%, and recovered lignin has low lignin carbohydrate complexes, low condensation, and rich in phenolic hydroxyl groups for 1.95 mmol/g. Meanwhile, the countercurrent pretreatment system can effectively reduce the deposition of lignin on the cellulose surface, which is evidently superior to the non-countercurrent pretreatment and facilitates the efficiency of enzymatic saccharification of substrate, achieving a high glucose yield of 99% as well as a total sugar yield of 91.11%. The method efficiently separates biomass in a green manner, and solid residues are easily hydrolyzed, showing potential for industrial-scale production.

09 BIOMASS FUELS↗

Spectral line identification from a photoionised silicon plasma in emission

Next-generation X-ray satellite telescopes such as XRISM, NewAthena and Lynx will enable observations of exotic astrophysical sources at unprecedented spectral and spatial resolution. Proper interpretation of these data demands that the accuracy of the models is at least within the uncertainty of the observations. One set of quantities that might not currently meet this requirement is transition energies of various astrophysically relevant ions. Current databases are populated with many untested theoretical calculations. Accurate laboratory benchmarks are required to better understand the coming data. We obtained laboratory spectra of X-ray lines from a silicon plasma at an average spectral resolving power of ∼7500 with a spherically bent crystal spectrometer on the Z facility at Sandia National Laboratories. Many of the lines in the data are measured here for the first time. We report measurements of 53 transitions originating from the K-shells of He-like to B-like silicon in the energy range between ∼1795 and 1880 eV (6.6–6.9 Å). The lines were identified by qualitative comparison against a full synthetic spectrum calculated with ATOMIC. The average fractional uncertainty (uncertainty/energy) for all reported lines is ∼5.4 × 10 −5 . We compare the measured quantities against transition energies calculated with RATS and FAC as well as those reported in the NIST ASD and XSTAR’s uaDB. Average absolute differences relative to experimentally measured values are 0.20, 0.32, 0.17 and 0.38 eV, respectively. All calculations/databases show good agreement with the experimental values; NIST ASD shows the closest match overall.

astrophysical plasmas↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Development of a Flow-through Cell for Ultrasonic Extraction (UE)─Single Particle (SP)─ICP-MS─an Approach for Nano/Microparticle Elemental and Isotopic Analysis

Nanotechnology is a salient part of the scientific landscape, and analytical approaches are rapidly evolving to enable small-scale characterization of nano- and microparticle compositions and impurities. Here, a flow-through sonicating cell was developed for direct particle extraction from a silicon wafer and integrated with an inductively coupled plasma–mass spectrometer (ICP-MS) for subsequent elemental and isotopic characterization of the released particles. Ultrasonic extraction (UE)─single particle (SP)─ICP-MS offers controlled particle mobilization from solid substrates and allows for increased sample throughput by eliminating the need for pre-extraction of particles and decreasing sample preparation steps. Coupling this device to an ICP-MS with a time-of-flight (TOF) mass analyzer, it is possible to distinguish unique isotopic compositions of the particles. Both tungsten and nickel isotopically tagged particles, which were deposited on Si wafers, are presented here with analysis via UE─SP─ICP-MS. This approach could support efforts in the fields of particle synthesis, nuclear safeguards and forensics, environmental monitoring, and semiconductor industries in which the detection of particles from substrates and wafers is critical.

Paul, Molly [ORNL] (ORCID:0009000009672055)↗

Coupling of Lipid Peroxidation and Criegee Intermediate Mediated Autoxidation in the Heterogeneous Oxidation of Linoleic Acid Aerosols

Autoxidation is an established mechanism for the degradation of organic molecules, which is relevant in the atmosphere, combustion processes, the environment, and the rancidification of lipids (commonly known as lipid peroxidation). Autoxidation proceeds via radical chain reactions involving hydroxyl (•OH), peroxy (RO2•), and alkoxy radicals, which are also prominent oxidants in the atmosphere. Recent reports have provided evidence for an alternative autoxidation mechanism driven instead by Criegee intermediates (CIs), which are produced from the reaction of β-hydroxy peroxy radicals (β-OH-RO2•). This work evaluates the contributions of these two mechanisms in the •OH initiated heterogeneous oxidation of linoleic acid (LA) aerosols. Reaction kinetics and product distributions are monitored using a vacuum ultraviolet photoionization aerosol time-of-flight mass spectrometer. To explain the observed kinetics, a kinetic model is developed that incorporates both the conventional peroxidation and alternative CI-mediated autoxidation mechanisms. We observe that the CI-mediated autoxidation pathways enhance the heterogeneous autoxidation rate, while the peroxidation reactions, although present, contributes less to the overall oxidation rate. α-Acyloxyalkyl hydroperoxides (AAHPs) are identified as key indicators for bimolecular reactions of CI with LA, highlighting the role of LA as a CI scavenger. Moreover, the measured functionalized LA products with hydroxyl or carbonyl group(s), serve as markers for the peroxidation reactions. In summary, this work presents a quantitative framework to understand the coupled reaction network of •OH, RO2•, β-OH-RO2• radicals, and CI in driving heterogeneous autoxidation, which is crucial for understanding degradation mechanisms of organic molecules in the environment and atmosphere.

Criegee intermediate↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Solvation Structure of 237 Np 4+ in a Noncomplexing Environment

Here, the solvation structure of an Np 4+ ion in an aqueous, noncomplexing and nonoxidizing environment of trifluoromethanesulfonic (triflic) acid was investigated with X-ray absorption spectroscopy (XAS) combined with ab initio molecular dynamics (AIMD) and time-dependent density functional theory (TDDFT) calculations. Np L III -edge X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) data were collected for Np 4+ in 1, 3, and 7 M triflic acid using a laboratory-scale spectrometer and separately at a synchrotron facility, producing data sets in excellent agreement. TDDFT calculations revealed a weak pre-edge feature not previously reported for Np L III -edge XANES. AIMD modeling results showed differences in the hydration shell of the Np 4+ ion at different concentrations of triflic acid; these results are supported by the experiment. EXAFS fit models to the experiment resulted in similar coordination of Np 4+ in noncomplexing aqueous media as reported in the literature for 1 M perchloric acid but, together with calculations, revealed more than one distance between Np and O atoms in 7 M triflic acid. These results imply monodentate coordination with sulfonate groups in 7 M triflic acid and suggest the possibility of proto-neptunyl species in relatively low-concentration Np 4+ acid solutions.

Boglaienko, Daria V. [Pacific Northwest National L↗

Demonstration of Capture, Cooling, Tagging, and Spectroscopic Characterization of UV Photoproduct Ions in a Cryogenic Ion Trap: Application to 266 nm Photofragment Ions from Rhodamine 6G

We demonstrate a method to determine the structures of the primary photodissociation products from a cryogenically cooled parent ion. In this approach, a target ion is cooled by a pulse of buffer gas and tagged in a 20 K Paul trap. The cold ion is then photodissociated by pulsed (~5 ns) UV laser excitation, and the ionic products are trapped, cooled, and tagged by introduction of a second buffer gas pulse in the same trap. The tagged fragments are then ejected into a triple focusing, UV/vis/IR time-of-flight photofragmentation mass spectrometer which yields vibrational and electronic spectra of the mass-selected photofragments. Furthermore, these methods are demonstrated by application to the 266 nm photodissociation of the Rhodamine 6G cation to yield the R575 fragment ion based on loss of ethene as well as to a weaker secondary fragment arising from loss of m/z 43.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Activation, Dehydrogenation, and Carbon–Carbon Coupling of Methane by Iridium Cations Studied by Infrared Multiple Photon Dissociation Spectroscopy and Density Functional Theory

Products resulting from the sequential activation of one, two, three, and four methane molecules by atomic iridium cations were characterized by gas-phase infrared multiple photon dissociation spectroscopy and density functional theory (DFT) calculations. Iridium cations were generated using a laser ablation source and reacted with methane in a linear radiofrequency ion trap before mass analysis and spectroscopic interrogation in a Fourier transform ion cyclotron resonance mass spectrometer coupled to the free-electron laser for intracavity experiments (FELICE) beamline. Product ions were irradiated using infrared light over the 250–1500 cm –1 range. Comparisons between the experimental and DFT-calculated spectra enabled structural determination of the products formed. The observed products include HIrCH + , Ir(CH 2 ) 2 + , H s Ir(C 3 H 5 ) + , and Ir(CH 3 ) s (C 3 H 5 ) + , where the subscript s denotes a syn orientation of the two ligands. Furthermore, formation of the latter two products provides evidence for efficient C–H bond activation and subsequent C–C coupling on the atomic iridium cation.

Chemical reactions↗

Photodissociation and Infrared Spectroscopy of U + (CO 2 ) n , UO + (CO 2 ) n , and UO 2+ (CO 2 ) n Cation-Molecular Complexes

Laser vaporization of uranium in a pulsed supersonic expansion of carbon dioxide is used to produce complexes of the form U + (CO 2 ) n , UO + (CO 2 ) n , and UO 2+ (CO 2 ) n . These ions are selected in a reflectron time-offlight mass spectrometer and studied with visible laser photodissociation and tunable infrared laser photodissociation spectroscopy in the region of the CO 2 antisymmetric stretch. The dissociation patterns and spectroscopy of these ions indicate that CO 2 ligands are intact molecules. Although reaction products that form oxide-carbonyl or oxalate species are predicted to be stable, there is no direct evidence in the frequency range studied for the formation of these species. There is no clear indication for the coordination numbers for singly charged uranium and its oxide complexes with CO 2 . However, there is strong support in the vibrational patterns for an eight-coordinate complex of the doubly charged UO 2+ species, i.e., UO 2+ (CO 2 ) 8 .

Cluster chemistry↗

Oxidation of Silicon Carbide with Atomic Oxygen through the Passive-to-Active Transition

The inelastic and reactive scattering dynamics of O( 3 P) atoms on a 6H-silicon carbide (SiC) surface were investigated as a function of temperature with a molecular beam-surface scattering technique that employed a rotatable mass spectrometer detector. One set of experiments used a pulsed hyperthermal beam that produced ~8 km s –1 O atoms, and another set of experiments used a continuous beam that contained O atoms with a nominal velocity of ~2 km s –1 . When exposed to the relatively low-flux, pulsed hyperthermal O-atom beam, a passive oxide layer on the SiC that formed at lower temperatures decomposed as the temperature increased above 1673 K. Instead of entering an active oxidation regime, a graphitic layer formed on the surface and largely protected the underlying SiC from incoming O atoms. Investigation of the oxide decomposition without O-atom bombardment revealed volatile Si and SiO products at the moment that the oxide decomposed, implying that Si sublimation occurs concurrently with oxide decomposition. In the experiment with the continuous (higher flux) O-atom beam, volatile SiO and CO products were observed after the passive oxide decomposed, indicating that active oxidation was reached. Finally, the results of this study provide evidence for the importance of Si sublimation within the active oxidation regime. Above the passive-to-active transition temperature, Si sublimation is an ongoing process, and continuous active oxidation will only occur if sufficient oxygen reacts with the surface to produce SiO more quickly than a graphitic layer can form. Thus, accurate models of SiC ablation by atomic oxygen must account for multiple competing mechanisms that depend on the surface temperature and incident O-atom flux.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoinduced Carbon Dioxide Release via a Metastable Photoacid in a Nonaqueous Environment

Capturing and concentrating carbon dioxide (CO 2 ) from the atmosphere is an important modern scientific and technological challenge. CO 2 can be captured by forming a carbamate bond with amines, most notably monoethanolamine (MEA). Regenerating MEA by releasing the captured CO 2 requires heating the carbamate solution, which is energy-demanding and wasteful. Recently, photoacids were used to convert light input into pH change, which in turn released CO 2 from aqueous carbonate solutions. Here, we report a merocyanine photoacid that releases CO 2 from a non-aqueous carbamate solution of MEA, thereby extending the utility of this concept to a wider range of capture agents and environments. Based on the absorption spectra of the photoacid in the presence of acids and CO 2 , we show that the photoacid cycle and the CO 2 capture of MEA are two separate equilibria that are coupled to each other via protons. Then, we demonstrate that irradiating 405 nm light on the sample can induce release of CO 2 which we detect using an in-line mass spectrometer. This work highlights an alternative path for optimizing a photo-induced CO 2 capture and release system.

Amines↗

Open-Source and FAIR Research Software for Proteomics

Scientific discovery relies on innovative software as much as experimental methods, especially in proteomics, where computational tools are essential for mass spectrometer setup, data analysis, and interpretation. Since the introduction of SEQUEST, proteomics software has grown into a complex ecosystem of algorithms, predictive models, and workflows, but the field faces challenges, including the increasing complexity of mass spectrometry data, limited reproducibility due to proprietary software, and difficulties integrating with other omics disciplines. Closed-source, platform-specific tools exacerbate these issues by restricting innovation, creating inefficiencies, and imposing hidden costs on the community. Open-source software (OSS), aligned with the FAIR Principles (Findable, Accessible, Interoperable, Reusable), offers a solution by promoting transparency, reproducibility, and community-driven development, which fosters collaboration and continuous improvement. In this manuscript, we explore the role of OSS in computational proteomics, its alignment with FAIR principles, and its potential to address challenges related to licensing, distribution, and standardization. Drawing on lessons from other omics fields, we present a vision for a future where OSS and FAIR principles underpin a transparent, accessible, and innovative proteomics community.

97 MATHEMATICS AND COMPUTING↗

SPE-CZE-MS Quantifies Zeptomole Amounts of Phosphorylated Peptides

Capillary zone electrophoresis (CZE) is gaining attention in the field of single-cell proteomics for its ultralow-flow and high-resolution separation abilities. Even more sample-limited yet rich in biological information are phosphoproteomics experiments, as the phosphoproteome composes only a fraction of the whole cellular proteome. Rapid analysis, high sensitivity, and maximization of sample utilization are paramount for single-cell analysis. Some challenges of coupling CZE analysis with mass spectrometry analysis (MS) of complex mixtures include 1. sensitivity due to volume loading limitations of CZE and 2. incompatibility of MS duty cycles with electropherographic time scales. Here, we address these two challenges as applied to singlecell- equivalent phosphoproteomics experiments by interfacing a microchip-based CZE device integrated with a solid-phaseextraction (SPE) bed with the Orbitrap Astral mass spectrometer. Using 225 phosphorylated peptide standards and phosphorylated peptide-enriched mouse brain tissue, we investigate microchip-based SPE-CZE functionality, quantitative performance, and complementarity to nano-LC-MS (nLC-MS) analysis. We highlight unique SPE-CZE separation mechanisms that can empower fitfor- purpose applications in single-cell-equivalent phosphoproteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Observation and Analysis of Low-Energy Magnons with Raman Spectroscopy in Atomically Thin NiPS 3

van der Waals (vdW) magnets have rapidly emerged as a fertile playground for fundamental physics and exciting applications. Despite the impressive developments over the past few years, technical limitations pose a severe challenge to many other potential breakthroughs. High on the list is the lack of suitable experimental tools for studying spin dynamics on atomically thin samples. Here, Raman scattering techniques are employed to directly observe the low-lying magnon (~1 meV) even in bilayer NiPS 3 . Further, the advantage is that it offers excellent energy resolutions far better on low-energy sides than most inelastic neutron spectrometers can offer. More importantly, with appropriate theoretical analysis, the polarization dependence of the Raman scattering by those low-lying magnons also provides otherwise hidden information on the dominant spin-exchange scattering paths for different magnons. By comparing with high-resolution inelastic neutron scattering data, these low-energy Raman modes are confirmed to be indeed of magnon origin. Because of the different scattering mechanisms involved in inelastic neutron and Raman scattering, this information is fundamental in pinning down the final spin Hamiltonian. This work demonstrates the capability of Raman spectroscopy to probe the genuine two-dimensional spin dynamics in atomically thin vdW magnets, which can provide insights that are obscured in bulk spin dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗