Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator) were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.

60 APPLIED LIFE SCIENCES↗

SU-E-T-169: Evaluation of Oncentra TPS for Nasopharynx Brachy Using Patient Specific Voxel Phantom and EGSnrc

Purpose: Nasopharnx carcinoma (NPC) treatment is being carried out using Ir-192 HDR seeds in Mehdieh Hospital in Hamadan, Iran. The Oncentra™ TPS is based on optimized TG-43 formalism which disregards heterogeneity in the treatment area. Due to abundant heterogeneity in head and neck, comparison of the Oncentra™ TPS dose evaluation and an accurate dose calculation method in NPC brachytherapy is the objective of this study. Methods: CT DICOMs of a patient with NPC obtained from Mehdieh Hospital used to create 3D voxel phantom with CTCREATE utility of EGSnrc code package. The voxel phantom together with Ir-192 HDR brachytherapy source were the input to DOSXYZnrc to calculate the 3D dose distribution. The sources were incorporate with type 6 source in DOSXYZnrc and their dwell times were taken into account in final dose calculations. Results: The direct comparison between isodoses as well as DVHs for the GTV, PTV and CTV obtained by Oncentra™ and EGSnrc Monte Carlo code are made. EGSnrc results are obtained using 5×10{sup 9} histories to reduce the statistical error below 1% in GTV and 5% in 5% dose areas. The standard ICRP700 cross section library is employed in DOSXYZnrc dose calculation. Conclusion: A direct relationship between increased dose differences and increased material density (hence heterogeneity) is observed when isodoses contours of the TPS and DOSXYZnrc are compared. Regarding the point dose calculations, the differences range from 1.2% in PTV to 5.6% for cavity region and 7.8% for bone regions. While Oncentra™ TPS overestimates the dose in cavities, it tends to underestimate dose depositions within bones.

60 APPLIED LIFE SCIENCES↗

SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-02: Application of ARCHERRT-- A GPU-Based Monte Carlo Dose Engine for Radiation Therapy -- to Tomotherapy and Patient-Independent IMRT

Purpose: As a module of ARCHER -- Accelerated Radiation-transport Computations in Heterogeneous EnviRonments, ARCHER{sub RT} is designed for RadioTherapy (RT) dose calculation. This paper describes the application of ARCHERRT on patient-dependent TomoTherapy and patient-independent IMRT. It also conducts a 'fair' comparison of different GPUs and multicore CPU. Methods: The source input used for patient-dependent TomoTherapy is phase space file (PSF) generated from optimized plan. For patient-independent IMRT, the open filed PSF is used for different cases. The intensity modulation is simulated by fluence map. The GEANT4 code is used as benchmark. DVH and gamma index test are employed to evaluate the accuracy of ARCHER{sub RT} code. Some previous studies reported misleading speedups by comparing GPU code with serial CPU code. To perform a fairer comparison, we write multi-thread code with OpenMP to fully exploit computing potential of CPU. The hardware involved in this study are a 6-core Intel E5-2620 CPU and 6 NVIDIA M2090 GPUs, a K20 GPU and a K40 GPU. Results: Dosimetric results from ARCHER{sub RT} and GEANT4 show good agreement. The 2%/2mm gamma test pass rates for different clinical cases are 97.2% to 99.7%. A single M2090 GPU needs 50~79 seconds for the simulation to achieve a statistical error of 1% in the PTV. The K40 card is about 1.7∼1.8 times faster than M2090 card. Using 6 M2090 card, the simulation can be finished in about 10 seconds. For comparison, Intel E5-2620 needs 507∼879 seconds for the same simulation. Conclusion: We successfully applied ARCHER{sub RT} to Tomotherapy and patient-independent IMRT, and conducted a fair comparison between GPU and CPU performance. The ARCHER{sub RT} code is both accurate and efficient and may be used towards clinical applications.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-03: Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT

Purpose: To compare the CT doses derived from the experiments and GPU-based Monte Carlo (MC) simulations, using a human cadaver and ATOM phantom. Methods: The cadaver of an 88-year old male and the ATOM phantom were scanned by a GE LightSpeed Pro 16 MDCT. For the cadaver study, the Thimble chambers (Model 10×5−0.6CT and 10×6−0.6CT) were used to measure the absorbed dose in different deep and superficial organs. Whole-body scans were first performed to construct a complete image database for MC simulations. Abdomen/pelvis helical scans were then conducted using 120/100 kVps, 300 mAs and a pitch factor of 1.375:1. For the ATOM phantom study, the OSL dosimeters were used and helical scans were performed using 120 kVp and x, y, z tube current modulation (TCM). For the MC simulations, sufficient particles were run in both cases such that the statistical errors of the results by ARCHER-CT were limited to 1%. Results: For the human cadaver scan, the doses to the stomach, liver, colon, left kidney, pancreas and urinary bladder were compared. The difference between experiments and simulations was within 19% for the 120 kVp and 25% for the 100 kVp. For the ATOM phantom scan, the doses to the lung, thyroid, esophagus, heart, stomach, liver, spleen, kidneys and thymus were compared. The difference was 39.2% for the esophagus, and within 16% for all other organs. Conclusion: In this study the experimental and simulated CT doses were compared. Their difference is primarily attributed to the systematic errors of the MC simulations, including the accuracy of the bowtie filter modeling, and the algorithm to generate voxelized phantom from DICOM images. The experimental error is considered small and may arise from the dosimeters. R01 grant (R01EB015478) from National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to the dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.

60 APPLIED LIFE SCIENCES↗

Smooth full field reconstruction of velocity and its gradients from noisy scattered velocimetry data in a cross-slot flow

We present a method combining generalized Tikhonov regularization with a finite element approximation for reconstructing smooth velocity and velocity gradient fields from spatially scattered and noisy velocity data in a two-dimensional complex flow domain. Synthetic velocity data for a cross-slot geometry are generated using the Oldroyd-B solution, subsequently perturbed by random noise. Performances of diverse finite element continuity-regularization criterion combinations are tested against noise-free data, while the optimum regularization parameter is determined using generalized cross-validation. The best performance is achieved for the velocity field and its gradients simultaneously by C{sup 2} continuous Hermite finite elements and minimization of a norm of the velocity's third derivative. The standard regularization criterion based on the second derivative is shown to lead to systematic distortions in boundary regions, allowing therefore a lower reduction in the statistical error. Furthermore, optical fields are calculated by applying a differential constitutive equation directly to the reconstructed flow kinematics; high quality velocity gradient fields are shown to be an essential prerequisite for their reliable prediction. Overall, the method is expedient to implement and does not require boundary conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of concentration and temperature dependences of precipitation kinetics in iron-copper alloys using kinetic Monte Carlo and stochastic statistical simulations

The previously developed ab initio model and the kinetic Monte Carlo method (KMCM) are used to simulate precipitation in a number of iron-copper alloys with different copper concentrations x and temperatures T. The same simulations are also made using an improved version of the previously suggested stochastic statistical method (SSM). The results obtained enable us to make a number of general conclusions about the dependences of the decomposition kinetics in Fe-Cu alloys on x and T. We also show that the SSM usually describes the precipitation kinetics in good agreement with the KMCM, and using the SSM in conjunction with the KMCM allows extending the KMC simulations to the longer evolution times. The results of simulations seem to agree with available experimental data for Fe-Cu alloys within statistical errors of simulations and the scatter of experimental results. Comparison of simulation results with experiments for some multicomponent Fe-Cu-based alloys allows making certain conclusions about the influence of alloying elements in these alloys on the precipitation kinetics at different stages of evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the electron antineutrino mass in tritium beta decay in the Troitsk nu-mass experiment

The results obtained in the Troitsk nu-mass experiment by measuring the electron-antineutrino mass in tritium beta decay are presented. The facility used consists of a gaseous windowless tritium source and an electrostatic electron spectrometer involving an adiabatic magnetic collimation. Runs in which measurement conditions were reliably established were thoroughly selected in analyzing data obtained from 1994 to 2004. All known systematic effects were taken into account. For the square of the electron-antineutrino mass, the treatment of measured spectra yielded the following result: m{sub {nu}}{sup 2} = -0.67 {+-} 1.89{sub stat.} {+-} 1.68{sub syst.} eV{sup 2}. The use of the Bayesian method and the Feldman-Cousins unified approach made it possible to obtain the following upper limits on the mass: m{sub {nu}} < 2.12 eV (at a 95% C.L.; Bayesian method) and m{sub {nu}} < 2.05 eV (at a 95% C.L., Feldman-Cousins method). At the same time, an estimation of the sensitivity limit without allowance for negative values of the square of the mass leads to m{sub {nu}} < 2.2 eV (at a 95% C.L.). Measured spectra were analyzed for the possible existence of an additional structure (step) in the electron spectrum near the boundary energy. The conclusion drawn from this analysis was that, within the existing statistical errors, there are no reasons for introducing such a feature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Features of the application of the Monte Carlo method to calculations for large RBMK reactors and to model correction on the basis of data from in-core detectors

Statistical errors in sampling neutron fields in physically large systems like an RBMK are analyzed both qualitatively and quantitatively. Recommendations concerning the choice of parameters for calculations are given. A new procedure for Monte Carlo RBMK calculations with model corrections on the basis of data from in-core detectors is proposed. Dedicated software based on the CUDA software and hardware platform is developed for computational research. Results of testing the procedure and software in question via calculations for real RBMK reactors are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Finite-size effect on two-particle production in continuous and discrete spectrum

The formalism allowing one to account for the effect of a finite space-time extent of particle production region is given. Its applications to the lifetime measurement of hadronic atoms produced by a high-energy beam in a thin target, as well as to the femtoscopy techniques widely used to measure space-time characteristics of the production processes, are discussed. Particularly, it is found that the neglect of the finite-size effect on the pionium lifetime measurement in the experiment DIRAC at CERN could lead to the lifetime overestimation comparable with the 10% statistical error. The theoretical systematic errors arising in the calculation of the finite-size effect due to the neglect of non-equal emission times in the pair center-of-mass system, the space-time coherence and the residual charge are shown to be negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin transfer to Λ and Λ-bar hyperons in deep inelastic scattering at HERMES

Preliminary results on the spin transfer to the Λ and Λ-bar hyperons measured by the HERMES Collaboration are presented. Longitudinal spin transfer directed along the virtual-photon momentum in the Λ rest frame is found to be D{sup Λ}{sub LL }= 0.19 ± 0.04{sub stat} ± 0.02{sub syst}, the transverse component being compatible with zero. For Λ-bar both longitudinal and transverse components are compatible with zero within statistical errors of ±0.1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The origin of the background radioactive isotope {sup 127}Xe in the sample of Xe enriched in {sup 124}Xe

The results of investigation of {sup 127}Xe radioactive isotope production in the xenon sample enriched in {sup 124}Xe, {sup 126}Xe, {sup 128}Xe are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of {sup 124}Xe. In this work we consider two channels of {sup 127}Xe production: the neutron knock-out from {sup 128}Xe nucleus by cosmogenic muons and the neutron capture by {sup 126}Xe nucleus. For the first channel the upper limit of the cross section of {sup 127}Xe production was found to be σ ≤ 0.007 × 10{sup −24} cm{sup 2} at 95% C.L. For the second channel the value obtained for the cross section was found to be equal to σ = (2.74 ± 0.4) × 10{sup −24} cm{sup 2}, which coincides well, within the statistical error, with reference value.

07 ISOTOPE AND RADIATION SOURCES↗

Critical Temperature of the Three-Vertex Potts Model on a Kagome Lattice

The Potts model on a Kagome lattice is considered. The Monte Carlo method is used to obtain the temperature dependences of the thermodynamic parameters: heat capacity C, order parameter m, and susceptibility χ. The calculations were performed for systems with periodic boundary conditions. Systems with linear dimensions L × L = N, L = 20–90, were considered. Based on the fourth-order Binder cumulant method, the critical temperature (T{sub c}) was calculated for the three-vertex Potts model on a Kagome lattice. It is shown that the obtained value of T{sub c}, within the statistical error, is in good agreement with the results obtained by the transfer matrix and polynomial approximation methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heavy-quark meson spectrum tests of the Oktay–Kronfeld action

The Oktay-Kronfeld (OK) action extends the Fermilab improvement program for massive Wilson fermions to higher order in suitable power-counting schemes. It includes dimension-six and -seven operators necessary for matching to QCD through order ${\mathrm{O}}(\Lambda^3/m_Q^3)$ in HQET power counting, for applications to heavy-light systems, and ${\mathrm{O}}(v^6)$ in NRQCD power counting, for applications to quarkonia. In the Symanzik power counting of lattice gauge theory near the continuum limit, the OK action includes all ${\mathrm{O}}(a^2)$ and some ${\mathrm{O}}(a^3)$ terms. To assess whether the theoretical improvement is realized in practice, we study combinations of heavy-strange and quarkonia masses and mass splittings, designed to isolate heavy-quark discretization effects. We find that, with one exception, the results obtained with the tree-level-matched OK action are significantly closer to the continuum limit than the results obtained with the Fermilab action. The exception is the hyperfine splitting of the bottom-strange system, for which our statistical errors are too large to draw a firm conclusion. Lastly, these studies are carried out with data generated with the tadpole-improved Fermilab and OK actions on 500 gauge configurations from one of MILC's $a\approx0.12$~fm, $N_f=2+1$-flavor, asqtad-staggered ensembles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine learning based design space exploration for hybrid main-memory design

We develop a machine learning (ML) based design space exploration (DSE) method that builds predictive models for various responses of a hybrid main-memory system. To overcome the challenges associated with latency, capacity, and power of memory systems in future extreme-scale machines, the hybrid memory architectures are being considered in which novel non-volatile memory (NVM) systems augment the traditional DRAM. However, way before their actual design and implementation, these emerging hybrid memory systems need to be simulated and analyzed to fully understand their capabilities and limitations. As the conventional architectural-level memory simulators require significant amounts of computational costs and time, we propose to utilize ML techniques for developing various memory-response models that can instantly provide a predicted response corresponding to any new memory configuration. Specifically, in this work, we apply four supervised ML techniques to build regression models for memory latency, bandwidth, power, and total read/write responses. The training and validation data for the ML methods are generated using NVMain memory simulator for DRAM, NVM, and their hybrid combinations. We demonstrate the results of the ML based memory-DSE method in terms of the learning curve characteristics for hyperparameter tuning and the statistical error analyses of the designed predictive models.

Sen, Satyabrata↗

Arctic Sea Ice Volume Variability over 1901–2010: A Model-Based Reconstruction

PIOMAS-20C, an Arctic sea ice reconstruction for 1901–2010, is produced by forcing the Pan-Arctic Ice Ocean Modeling and Assimilation System (PIOMAS) with ERA-20C atmospheric data. ERA-20C performance over Arctic sea ice is assessed by comparisons with measurements and data from other reanalyses. ERA-20C performs similarly with respect to the annual cycle of downwelling radiation, air temperature, and wind speed compared to reanalyses with more extensive data assimilation such as ERA-Interim and MERRA. PIOMAS-20C sea ice thickness and volume are then compared with in situ and aircraft remote sensing observations for the period of ~1950–2010. Error statistics are similar to those for PIOMAS. We compare the magnitude and patterns of sea ice variability between the first half of the twentieth century (1901–40) and the more recent period (1980–2010), both marked by sea ice decline in the Arctic. The first period contains the so-called early-twentieth-century warming (ETCW; ~1920–40) during which the Atlantic sector saw a significant decline in sea ice volume, but the Pacific sector did not. The sea ice decline over the 1979–2010 period is pan-Arctic and 6 times larger than the net decline during the 1901–40 period. Sea ice volume trends reconstructed solely from surface temperature anomalies are smaller than PIOMAS-20C, suggesting that mechanisms other than warming, such as changes in ice motion and deformation, played a significant role in determining sea ice volume trends during both periods.

54 ENVIRONMENTAL SCIENCES↗

Pangeo-Enabled ESM Pattern Scaling (PEEPS): A customizable dataset of emulated Earth System Model output

Emulation through pattern scaling is a well-established method of rapidly producing climate fields (like temperature or precipitation) from existing Earth System Model (ESM) output that, while inaccurate, is often useful for a variety of downstream purposes. Conducting pattern scaling has historically been a laborious process, in large part due to the increasing volume of ESM output data that has often required downloading and storing locally to train on. Here we describe the Pangeo-Enabled ESM Pattern Scaling (PEEPS) dataset, a repository of trained annual and monthly patterns from CMIP6 outputs. This manuscript describes and validates these updated patterns so that users can save effort calculating and reporting error statistics in manuscripts focused on the use of patterns. The trained patterns are available as NetCDF files on Zenodo for ease of use in the impact community, and are reproducible with the code provided via GitHub in both Jupyter notebook and Python script formats. Because all training data for the PEEPS data set is cloud-based, users do not need to download and house the ESM output data to reproduce the patterns in the zenodo archive, should that be more efficient. Validating the PEEPS data set on the CMIP6 archive for annual and monthly temperature, precipitation, and near-surface relative humidity, pattern scaling performs well over a variety of future scenarios except for regions in which there are strong, potentially nonlinear climate feedbacks. Although pattern scaling is normally conducted on annual mean ESM output data, it works equally well on monthly mean ESM output data. We identify several downstream applications of the PEEPS data set, including impacts assessment and evaluating certain types of Earth system uncertainties.

54 ENVIRONMENTAL SCIENCES↗