Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stream Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Elemental Mercury Recovery in DWPF by pH and Ionic Strength Studies Using Laboratory Scale Replica – 26141

In order to safely disposition nuclear material at large scales, the Savannah River Site (SRS) constructed the Salt Waste Processing Facility (SWPF) for the removal of actinides, the Saltstone facility for preparation of a low-level cementitious grout, and the Defense Waste Processing Facility (DWPF) for the vitrification of high-level waste (HLW). A few years after processing began, high concentrations of mercury were discovered in cementitious waste at the Saltstone facility which initiated a search for the source of mercury during processing at these SRS facilities. Mercury serves as a catalyst in the dissolution of spent nuclear fuel, aluminum-actinide alloys, for actinide recovery, but not enough is known about the behavior and properties of mercury within these process streams.

Pina, Jeanette [Savannah River National Laboratory↗

Active Interrogation Using Electronic Neutron Generators for Nuclear Safeguards Applications

Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. The most commonly used technique for performing active interrogation is to use an electronic neutron generator as the probe radiation source. Exploiting the unique operating characteristics of these devices, including their monoenergetic neutron emissions and their ability to operate in pulsed modes, presents a number of options for performing prompt and delayed signature analyses using both photon and neutron sensors. A review of literature in this area shows multiple applications of the active neutron interrogation technique for performing nuclear nonproliferation measurements. Some examples include measuring the plutonium content of spent fuel, assaying plutonium residue in spent fuel hull claddings, assaying plutonium in aqueous fuel reprocessing process streams, and assaying nuclear fuel reprocessing facility waste streams to detect and quantify fissile material. This paper discusses the historical use of this technique and examines its context within the scope and challenges of next-generation nuclear fuel cycles and advanced concept nuclear fuel cycle facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complex admixtures of clathrate hydrates in a water desalination method

Disclosed is a method that achieves water desalination by utilizing and optimizing clathrate hydrate phenomena. Clathrate hydrates are crystalline compounds of gas and water that desalinate water by excluding salt molecules during crystallization. Contacting a hydrate forming gaseous species with water will spontaneously form hydrates at specific temperatures and pressures through the extraction of water molecules from the bulk phase followed by crystallite nucleation. Subsequent dissociation of pure hydrates yields fresh water and, if operated correctly, allows the hydrate-forming gas to be efficiently recycled into the process stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Process and apparatus for separation of components of a gas stream

A process and apparatus for separating a gas mixture comprising providing a slot in a gas separation channel (conceptualized as a laterally elongated Clusius-Dickel column), having a length through which a net cross-flow of the gas mixture may be established; applying a higher temperature to one side of the channel and a lower temperature on an opposite side of the channel thereby causing thermal-diffusion and buoyant-convection flow to occur in the slot; and establishing a net cross-flow of a gas mixture comprising at least one higher density gas component and at least one lower density gas component along the length of the slot, wherein the cross-flow causes, in combination with the convection flow, a spiraling flow in the slot; and wherein the spiral flow causes an increasing amount of separation of the higher density gas from the lower density gas along the length of the channel. The process may use one or more slots and/or channels.

47 OTHER INSTRUMENTATION↗

Process and apparatus for separation of components of a gas stream

A process and apparatus for separating a gas mixture comprising providing a slot in a gas separation channel (conceptualized as a laterally elongated Clusius-Dickel column), having a length through which a net cross-flow of the gas mixture may be established; applying a higher temperature to one side of the channel and a lower temperature on an opposite side of the channel thereby causing thermal-diffusion and buoyant-convection flow to occur in the slot; and establishing a net cross-flow of a gas mixture comprising at least one higher density gas component and at least one lower density gas component along the length of the slot, wherein the cross-flow causes, in combination with the convection flow, a spiraling flow in the slot; and wherein the spiral flow causes an increasing amount of separation of the higher density gas from the lower density gas along the length of the channel. The process may use one or more slots and/or channels.

47 OTHER INSTRUMENTATION↗

Process and apparatus for separation of components of a gas stream

A process and apparatus for separating a gas mixture comprising providing a slot in a gas separation channel (conceptualized as a laterally elongated Clusius-Dickel column), having a length through which a net cross-flow of the gas mixture may be established; applying a higher temperature to one side of the channel and a lower temperature on an opposite side of the channel thereby causing thermal-diffusion and buoyant-convection flow to occur in the slot; and establishing a net cross-flow of a gas mixture comprising at least one higher density gas component and at least one lower density gas component along the length of the slot, wherein the cross-flow causes, in combination with the convection flow, a spiraling flow in the slot; and wherein the spiral flow causes an increasing amount of separation of the higher density gas from the lower density gas along the length of the channel. The process may use one or more slots and/or channels.

42 ENGINEERING↗

A quantitative analysis of hydraulic interaction processes in stream-aquifer systems

The hydraulic relationship between the stream and aquifer can be altered from hydraulic connection to disconnection when the pumping rate exceeds the maximum seepage flux of the streambed. This study proposes to quantitatively analyze the physical processes of stream-aquifer systems from connection to disconnection. A free water table equation is adopted to clarify under what conditions a stream starts to separate hydraulically from an aquifer. Both the theoretical analysis and laboratory tests have demonstrated that the hydraulic connectedness of the stream-aquifer system can reach a critical disconnection state when the horizontal hydraulic gradient at the free water surface is equal to zero and the vertical is equal to 1. A boundary-value problem for movement of the critical point of disconnection is established for an analytical solution of the inverted water table movement beneath the stream. The result indicates that the maximum distance or thickness of the inverted water table is equal to the water depth in the stream, and at a steady state of disconnection, the maximum hydraulic gradient at the streambed center is 2. In conclusion, this study helps us to understand the hydraulic phenomena of water flow near streams and accurately assess surface water and groundwater resources.

42 ENGINEERING↗

Removal of hydrogen sulfide as ammonium sulfate from hydropyrolysis product vapors

A system and method for processing biomass into hydrocarbon fuels that includes processing a biomass in a hydropyrolysis reactor resulting in hydrocarbon fuels and a process vapor stream and cooling the process vapor stream to a condensation temperature resulting in an aqueous stream. The aqueous stream is sent to a catalytic reactor where it is oxidized to obtain a product stream containing ammonia and ammonium sulfate. A resulting cooled product vapor stream includes non-condensable process vapors comprising H.sub.2, CH.sub.4, CO, CO.sub.2, ammonia and hydrogen sulfide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of hydrogen sulfide as ammonium sulfate from hydropyrolysis product vapors

A system and method for processing biomass into hydrocarbon fuels that includes processing a biomass in a hydropyrolysis reactor resulting in hydrocarbon fuels and a process vapor stream and cooling the process vapor stream to a condensation temperature resulting in an aqueous stream. The aqueous stream is sent to a catalytic reactor where it is oxidized to obtain a product stream containing ammonia and ammonium sulfate. A resulting cooled product vapor stream includes non-condensable process vapors comprising H.sub.2, CH.sub.4, CO, CO.sub.2, ammonia and hydrogen sulfide.

09 BIOMASS FUELS↗

Nitrogen processing by grazers in a headwater stream: riparian connections

Primary consumers play important roles in the cycling of nutrients in headwater streams, storing assimilated nutrients in growing tissue and recycling them through excretion. Though environmental conditions in most headwater streams and their surrounding terrestrial ecosystems vary considerably over the course of a year, relatively little is known about the effects of seasonality on consumer nutrient recycling these streams. Here, we measured nitrogen accumulated through growth and excreted by the grazing snail Elimia clavaeformis (Pleuroceridae) over the course of 12 months in Walker Branch, identifying close connections between in-stream nitrogen processing and seasonal changes in the surrounding forest.

54 ENVIRONMENTAL SCIENCES↗

R-process-rich Stellar Streams in the Milky Way*

We present high-resolution Magellan/MIKE spectra of 22 bright (9 < V < 13.5) metal-poor stars (-3.18 < [Fe/H] < -1.37) in three different stellar streams, the Helmi debris stream, the Helmi trail stream, and the ω Centauri progenitor stream. We augment our Helmi debris sample with results for 10 stars by Roederer et al. for a total of 32 stars. Detailed chemical abundances of light elements as well as heavy neutron-capture elements have been determined for our 22 stars. All three streams contain carbon-enhanced stars. For 13 stars, neutron-capture element lines were detectable, and they all show signatures in agreement with the scaled solar r -process pattern, albeit with a large spread of -0.5 < [Eu/Fe] < +1.3. Eight of these stars show an additional small s -process contribution superposed onto their r -process pattern. This could be discerned because of the relatively high signal-to-noise ratio of the spectra given that the stars are close by in the halo. Our results suggest that the progenitors of these streams experienced one or more r -process events early on, such as a neutron star merger or another prolific r -process source. This widely enriched these host systems before their accretion by the Milky Way. The small s -process contribution suggests the presence of asymptotic giant branch stars and associated local (inhomogeneous) enrichment as part of the ongoing chemical evolution by low-mass stars. Stars in stellar streams may thus be a promising avenue for studying the detailed history of large dwarf galaxies and their role in halo assembly with easily accessible targets for high-quality spectra of many stars.

Astronomy & Astrophysics↗

System for processing an encrypted instruction stream in hardware

A system and method of processing an encrypted instruction stream in hardware is disclosed. Main memory stores the encrypted instruction stream and unencrypted data. A central processing unit (CPU) is operatively coupled to the main memory. A decryptor is operatively coupled to the main memory and located within the CPU. The decryptor decrypts the encrypted instruction stream upon receipt of an instruction fetch signal from a CPU core. Unencrypted data is passed through to the CPU core without decryption upon receipt of a data fetch signal.

97 MATHEMATICS AND COMPUTING↗

Test Plan to Demonstrate Removal of Iodine and Tritium from Simulated Nuclear Fuel Recycle Plant Off-Gas Streams Using Adsorption Processes (Milestone Report)

The objective of this test plan is to describe research that will determine the effectiveness of silver mordenite and molecular sieve beds to remove iodine and water (tritium) from off-gas streams arising from used nuclear fuel recycling processes, and to demonstrate that the iodine and water can be recovered separately from one another.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Next Generation Spectrophotometer System for Enhanced In-process Pu Monitoring of Effluent Waste Streams - 17268

The Next Generation Spectrophotometer (NGS) system is an in-process monitoring system developed by SRNL to determine Pu concentration in nuclear processing streams at the Savannah River Site (SRS). Development of the NGS system began from a need to replace aged Pu monitoring equipment whose measurement uncertainty greatly reduced process throughput. The NGS system implements absorption spectroscopy technology to determine total Pu concentration and Pu valence state distributions by measuring the light absorbance of a solution. The NGS system was completed and installed in the later part of 2016. It provides an excellent example of process intensification, i.e. replacement of aged systems with smarter, more accurate and operationally efficient systems. This paper will detail the capabilities of the NGS system, its application in the nuclear processing stream, and operational challenges working with Pu solutions. Discussion will include the development of the virtual instrument which negates the intrinsic differences between actual instruments and implements a technique that performs continuous intensity and waveform calibration. Other notable features discussed are the development of a new modeling application method which applies custom models based on the current operating region of the process and the ability to perform in-field calibrations using NIST-traceable standards. Lastly, the benefits encapsulated in the final system including the significant improvement in measurement certainty, process intensification efficiencies, and the ease of adaptability of this system for use with other actinide and chemical measurement applications will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tools for Developing a Quality Management Program: Proactive Tools (Process Mapping, Value Stream Mapping, Fault Tree Analysis, and Failure Mode and Effects Analysis)

This article examines the concepts of quality management (QM) and quality assurance (QA), as well as the current state of QM and QA practices in radiotherapy. A systematic approach incorporating a series of industrial engineering-based tools is proposed, which can be applied in health care organizations proactively to improve process outcomes, reduce risk and/or improve patient safety, improve through-put, and reduce cost. This tool set includes process mapping and process flowcharting, failure modes and effects analysis (FMEA), value stream mapping, and fault tree analysis (FTA). Many health care organizations do not have experience in applying these tools and therefore do not understand how and when to use them. As a result there are many misconceptions about how to use these tools, and they are often incorrectly applied. This article describes these industrial engineering-based tools and also how to use them, when they should be used (and not used), and the intended purposes for their use. In addition the strengths and weaknesses of each of these tools are described, and examples are given to demonstrate the application of these tools in health care settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods and systems for liquid separations

Methods and systems for separating liquid components are disclosed. A vessel is provided containing a solids conveyance device. At least a first portion of the vessel acts as an indirect-contact heat exchanger and a second portion of the vessel contains a filter. A process liquid stream, containing a first component and a second component, is passed into the first portion of the vessel. A portion of the second component is frozen and entrained in the first portion of the vessel into the process liquid stream, resulting in a process slurry stream. The process slurry stream is passed into a second portion of the vessel by the solids conveyance device. The process slurry stream is separated into a solid product stream and a primary liquid product stream by passing the primary liquid product stream through the filter and out of the vessel while separately removing the solid product stream out of the vessel.

Baxter, Larry↗