Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Controlling T c of iridium films using the proximity effect

A superconducting Transition-Edge Sensor (TES) with low-$T_c$ is essential in a high resolution calorimetric detection. With a motivation of developing sensitive calorimeters for applications in cryogenic neutrinoless double beta decay searches, we have been investigating methods to reduce the $T_c$ of an Ir film down to 20 mK. Utilizing the proximity effect between a superconductor and a normal metal, we found two room temperature fabrication recipes of making Ir-based low-$T_c$ films. In the first approach, an Ir film sandwiched between two Au films, a Au/Ir/Au trilayer, has a tunable $T_c$ in the range of 20-100 mK depending on the relative thicknesses. In the second approach, a paramagnetic Pt thin film is used to create Ir/Pt bilayer with a tunable $T_c$ in the same range. We present detailed study of fabrication and characterization of Ir-based low-$T_c$ films, and compare the experimental results to theoretical models. We show that Ir-based films with predictable and reproducible critical temperature can be consistently fabricated for use in large scale detector applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Weyl phonons: the connection of topology and chirality

Topology and chirality of fermionic quasiparticles have enabled exciting discoveries, including quantum anomalous Hall liquids and topological superconductivity. Recently, topological and chiral phonons emerge as new and fast-evolving research directions. While these concepts are separately developed, they are intimately connected in the context of Weyl phonons. The couplings between chiral and topological phonons with various electronic and magnetic quasiparticles are predicted to give rise to new quantum states and giant magnetism with fundamental and applicational interests, ranging from quantum information science to dark matter detectors.

Zhang, Tiantian [Chinese Academy of Sciences (CAS)↗

Single Photon Detection with On-Chip Number Resolving Capability

Single photon detection (SPD) plays an important role in many forefront areas of fundamental science and advanced engineering applications. In recent years, rapid developments in superconducting quantum computation, quantum key distribution, and quantum sensing call for SPD in the microwave frequency range. We have explored in this LDRD project a new approach to SPD in an effort to provide deterministic photon-number-resolving capability by using topological Josephson junction structures. In this SAND report, we will present results from our experimental studies of microwave response and theoretical simulations of microwave photon number resolving detector in topological Dirac semimetal Cd 3 As 2 . These results are promising for SPD at the microwave frequencies using topological quantum materials.

47 OTHER INSTRUMENTATION↗

Design of the SPT-SLIM Focal Plane: A Spectroscopic Imaging Array for the South Pole Telescope

The Summertime Line Intensity Mapper (SLIM) is a mm-wave line-intensity mapping (mm-LIM) experiment for the South Pole Telescope (SPT). The goal of SPT-SLIM is to serve as a technical and scientific pathfinder for the demonstration of the suitability and in-field performance of multi-pixel superconducting filterbank spectrometers for future mm-LIM experiments. Scheduled to deploy in the 2023-24 austral summer, the SPT-SLIM focal plane will include 18 dual-polarisation pixels, each coupled to an $R = \lambda / \Delta \lambda = 300$ thin-film microstrip filterbank spectrometer that spans the 2 mm atmospheric window (120–180 GHz). Each individual spectral channel feeds a microstrip-coupled lumped-element kinetic inductance detector, which provides the highly multiplexed readout for the 10k detectors needed for SPT-SLIM. Here, we present an overview of the preliminary design of key aspects of the SPT-SLIM focal plane array, a description of the detector architecture and predicted performance, and initial test results that will be used to inform the final design of the SPT-SLIM spectrometer array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Flux-Tunable cavity for Dark matter detection

Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical tuning, moving parts around to change electromagnetic boundary conditions. However, these cavities have proven challenging to operate in sub-Kelvin cryogenic environments due to differential thermal contraction, low heat capacities, and low thermal conductivities. Instead, we develop an electronically tunable cavity architecture by coupling a superconducting 3D microwave cavity with a DC flux tunable SQUID. With a flux delivery system engineered to maintain high coherence in the cavity, we perform a hidden-photon dark matter search below the quantum-limited threshold. A microwave photon counting technique is employed through repeated quantum non-demolition measurements using a transmon qubit. With this device, we perform a hidden-photon search and constrain the kinetic mixing angle to ${\varepsilon}< 8.2\times 10^{-15}$ in a tunable band from 5.672 GHz to 5.694 GHz. By coupling multimode tunable cavities to the transmon, wider hidden-photon searching ranges are possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-Photon Detector & Counter for Transduction

Over the recent years, quantum computers have procured the attention of the public, largely due to their fast factoring capabilities and potential for efficient simulation of quantum dynamics \cite{RevModPhys.79.135}. This interest, coupled with advances in quantum transduction, could lead to the realization of a quantum distributed network, effectively linking dilution fridges across vast distances. Presently, there are several qubit systems developed for encoding quantum information. They primarily fall into two categories: those exploiting optical frequencies for excitation, and those operating at microwave frequencies. Optical frequency qubit systems include trapped ions, neutral atoms, quantum dots, and solid-state defects. Microwave frequency qubit system encompass superconducting qubits (transmon) and spins in crystals. Among these, transmons are particularly intriguing due to their low-loss of photons at microwave frequencies. The Josephson effect within a superconducting circuit enables high-fidelity quantum operations \cite{Microwave-optical_quantum_frequency_conversion}. Thus, it is non-trivial to develop an apparatus for efficiently bridging microwave and optical frequency regimes.

Bautista-Cortezano, Pablo↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

43 PARTICLE ACCELERATORS↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

Makovec, Alajos↗

Resolution of 100 photons and quantum generation of unbiased random numbers

Macroscopic quantum phenomena, such as observed in superfluids and superconductors, have led to promising technological advancements and some of the most important tests of fundamental physics. At present, quantum detection of light is mostly relegated to the microscale, where avalanche photodiodes are very sensitive to distinguishing single-photon events from vacuum but cannot differentiate between larger photon-number events. Beyond this, the ability to perform measurements to resolve photon numbers is highly desirable for a variety of quantum information applications including computation, sensing, and cryptography. True photon-number resolving detectors do exist, but they are currently limited to the ability to resolve on the order of 10 photons, which is too small for certain proposals. In this work, we extend photon measurement into the mesoscopic regime by implementing a detection scheme based on multiplexing highly quantum-efficient transition-edge sensors to accurately resolve photon numbers between zero and 100. Further, we then demonstrate the use of our system by implementing a quantum random number generator with no inherent bias. This method is based on sampling a coherent state in the photon-number basis and is robust against environmental noise, phase and amplitude fluctuations in the laser, loss and detector inefficiency as well as eavesdropping. Beyond true random number generation, our detection scheme serves as a means to implement quantum measurement and engineering techniques valuable for photonic quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

UCGretina geant4 simulation of the GRETINA Gamma-Ray Energy Tracking Array

UCGretina, a geant4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at v / c ≳0.3 at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. In conclusion, we adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-frequency gravitational wave detection by the BREAD experiment

The use of experiments searching for light axion dark matter as high-frequency gravitational wave detectors has garnered increasing attention in recent years. We explore the capabilities of the Broadband Reflector Experiment for Axion Detection (BREAD) in probing the GW parameter space and study the directional dependence of its coverage. This detector can investigate frequencies ranging from 0.05 to 200 THz. We find that by employing single photon detectors, BREAD is sensitive to GWs with characteristic strains as low as 10 −21 at 0.1 THz and 10 −25 at 200 THz with a year exposure time, making it competitive with other proposals operating at similar frequencies.

axions↗