Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Examination of the effect of system pressure ratio and heat recuperation on the efficiency of a coal based gas turbine fuel cell hybrid power generation system with CO2 capture

This paper examines two coal-based hybrid configurations that employ separated anode and cathode streams for the capture and compression of CO2. One configuration uses a standard Brayton cycle, and the other adds heat recuperation ahead of the fuel cell. Results show that peak efficiencies near 55% are possible, regardless of cycle configuration, including the cost in terms of energy production of CO2 capture and compression. The power that is required to capture and compress the CO2 is shown to be approximately 15% of the total plant power.

01 COAL, LIGNITE, AND PEAT↗

Adaptive Vibration Reduction System Shown to Effectively Eliminate Vibrations for the Stirling Radioisotope Power System

Stirling Technology Company (STC), as part of a Small Business Innovation Research contract Phase II with the NASA Glenn Research Center at Lewis Field, is developing an Adaptive Vibration Reduction System (AVRS) that will effectively eliminate vibrations for the Stirling radioisotope power system. The AVRS will reduce vibration levels for two synchronized, opposed Stirling converters by a factor of 10 or more under normal operating conditions. Even more importantly, the AVRS will be adaptive and will be able to adjust to any changing converter conditions over the course of a mission. The Stirling converter is being developed by NASA and the Department of Energy (DOE) as a high-efficiency option for a radioisotope power system to provide onboard electric power for NASA deep space missions. The high Stirling efficiency of over 25 percent for this application will reduce the required amount of isotope by more than a factor of 3 in comparison to the current radioisotope thermoelectric generators (RTG s). Stirling is the most developed converter option of the advanced power technologies under consideration.

Thieme, Lanny G.↗

Ultrasonic Bat Deterrent Technology

The project objective was to advance the development and testing of a near commercial bat-deterrent system with a goal to increase the current GE deterrent system effectiveness to over 50% with broad species applicability. Additionally, the research supported by this program has provided insights into bat behavior and ultrasonic deterrent design that had not previously been explored. Prior research and development had demonstrated the effectiveness of a commercial-grade, air-powered, ultrasonic bat deterrent to be between 30-50% depending upon the species of bat. However, the previous research provided limited insight into the behavioral responses of bats in the presence of ultrasonic deterrent sound fields that could be utilized to improve effectiveness. A unique bat flight room was utilized to observe the behavioral characteristics of bats in the presence of ultrasonic sound fields. Behavioral testing in the bat flight facility demonstrated that ultrasonic sounds similar to those produced by the GE deterrent influenced the activities and behaviors, primarily those associated with foraging, of the species exposed. The study also indicated that continuous and pulsing ultrasonic signals had a similar effect on the bats, and confirmed that as ultrasonic sounds attenuate, their influence on the bats’ activities and behavior decreases. Ground testing at Wolf Ridge Wind, LLC and Shawnee National Forest assessed both continuous and pulsing deterrent signals emitted from the GE deterrent system and further enhanced the behavioral understanding of bats in the presence of the deterrent. With these data and observations, the existing 4-nozzle continuous, or steady, emission ultrasonic system was redesigned to a 6-nozzle system that could emit a pulsing signal covering a larger air space around a turbine. Twelve GE 1.6-100 turbines were outfitted with the deterrent system and a formal three-month field study was performed using daily carcass searches beneath the 12 turbines. Additionally, a unique 3D bat flight path visualization system was utilized to monitor for and identify any changes in bat activity caused by the operation of the deterrent system. Both the carcass search and flight path visualization data indicated that the pulsed deterrent system was effective, but not more effective, than the steady system tested in prior years. However, an unanticipated byproduct of the pulsing system was the emission of intermittent water vapor from the deterrent devices due to the air compression process that powered the devices. This water vapor may have altered the ultrasonic signal and obscured the results in an unknown way. While a qualitative analysis of the effect of the water vapor on the deterrent signal had indicated there was not dramatic change in the expected ultrasonic signal, it was not possible to conclusively determine if the pulse signal would have been more effective in the absence of the water vapor. A mid-season installation of a desiccant system was performed and the dataset divided into two groups to account for the change. Prior to the system change, the deterrent was not effective (-23%, P = 0.8617, α = 0.05) at reducing eastern red bat fatalities and effective (38%, P = 0.0169, α = 0.05) for the non-eastern red bat species, combined. After the installation of the desiccant system, the pulsed deterrent system showed similar results, although not statistically significant, with a point estimates of 23% (P = 0.2924, α = 0.05) observed for eastern red bats and 54% (P = 0.0926, α = 0.05) for the other combined bat species.

17 WIND ENERGY↗

Quantifying the effects of the self-interaction error in density functional theory: When do the delocalized states appear? II. Iron-oxo complexes and closed-shell substrate molecules

Effects of the self-interaction error (SIE) in approximate density functional theory have several times been reported and quantified for the dissociation of charged radicals, charge transfer complexes, polarizabilities, and for transition states of reactions involving main-group molecules. In the present contribution, effects of the SIE in systems composed of a catalytic transition metal complex and a closed-shell substrate molecule are investigated. For this type of system, effects of the SIE have not been reported earlier. It is found that although the best density functionals (e.g., B3LYP) are capable of accurate predictions of structure, thermodynamics, and reactivity of such systems, there are situations and systems for which the magnitude of the SIE can be large, and for which the effects can be severe for the modeling of chemical reactivity. The largest energetic effect reported here is the artificial stabilization of a catalyst-substrate complex by as much as 18 kcal/mol. Also, the disappearance of significant energy barriers for hydrogen atom transfer in certain systems are reported. In line with earlier work, it is found that the magnitude of the SIE is related to the energetics of electron transfer between the metal catalyst and the substrate molecule. It is suggested that these problems might be circumvented by the inclusion of counterions or point charges that would alter the energetics of electron transfer. It is also pointed out that the effects of SIE in the modeling of transition metal reactivity need to be investigated further.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A safety and tolerability study of differently-charged nanoparticles for local pulmonary drug delivery

Nanoparticle (NP) based drug delivery systems provide promising opportunities in the treatment of lung diseases. Here we examined the safety and tolerability of pulmonary delivered NPs consisting of PEG-PLA as a function of particle surface charge. The rationale for such a comparison should be attributed to the differential pulmonary toxicity of positively and negatively charged PEG-PLA NP. Thus, the local and systemic effects of pulmonary administered NPs were investigated following 5 days of daily endotracheal instillation to BALB/c mice that were euthanized on the eighth or nineteenth day of the experiment. We collected bronchoalveolar lavages and studied hematological as well as histochemistry parameters. Notably, the cationic stearylamine based PEG-PLA NPs elicited increased local and systemic toxic effects both on the eighth and nineteenth day. In contrast, anionic NPs of similar size were much better tolerated with local inflammatory effects observed only on the eighth experimental day after pulmonary instillation. No systemic toxicity effect was observed although a moderate change was noted in the platelet count that was not considered to be of clinical significance. No pathological observations were detected in the internal organs following instillation of anionic NPs. Overall these observations suggest that anionic PEG-PLA NPs are useful pulmonary drug carriers that should be considered as a promising therapeutic drug delivery system.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Assessment of System Frequency Support Effect of PMSG-WTG Using Torque-Limit-Based Inertial Control

To release the 'hidden inertia' of variable-speed wind turbines for temporary frequency support, a method of torque-limit-based inertial control is proposed in this paper. This method aims to improve the frequency support capability considering the maximum torque restriction of a permanent magnet synchronous generator. The advantages of the proposed method are improved frequency nadir (FN) in the event of an under-frequency disturbance; and avoidance of over-deceleration and a second frequency dip during the inertial response. The system frequency response is different, with different slope values in the power-speed plane when the inertial response is performed. The proposed method is evaluated in a modified three-machine, nine-bus system. The simulation results show that there is a trade-off between the recovery time and FN, such that a gradual slope tends to improve the FN and restrict the rate of change of frequency aggressively while causing an extension of the recovery time. These results provide insight into how to properly design such kinds of inertial control strategies for practical applications.

17 WIND ENERGY↗

A Model for the Effectiveness of Aircraft Alerting and Warning Systems

The effectiveness of an alerting system with a single alert was analyzed. The pilot's decision behavior is modeled by the theory of signal detection and therefore accounts for different strengths of cross check information and different pilot criteria. The model includes the effects of the alerting and warning system (CAWS) error rate; the pilot's past experience with the CAWS accuracy; his reliance on the CAWS rather than independent monitoring; missed alerts; and adoption of a minimum error or Neyman-Pearson objective rather than minimum cost objective. It is showwn that for rare events: (1) the expected cost is greatly increased if the pilot ignores the a posteriori information in the existence of an alert; (2) the expected cost is insensitive to CAWS Type 1 errors; and (3) the expected cost is sensitive to CAWS type 2 errors only when the cross check information is ambiguous.

Curry, R. E.↗

Effect of soiling in CPV systems

The effect of soiling in flat PV modules has been already studied, causing a reduction of the electrical output of 4% on average. For CPV's, as far as soiling produces light scattering at the optical collector surface, the scattered rays should be definitively lost because they cannot be focused onto the receivers again. While the theoretical study becomes difficult because soiling is variable at different sites, it becomes easier to begin the monitoring of the real field performance of concentrators and then raise the following question: how much does the soiling affect to PV concentrators in comparison with flat panels?' The answers allow to predict the PV concentrator electrical performance and to establish a pattern of cleaning frequency. Some experiments have been conducted at the IES-UPM and CSES-ANU sites, consisting in linear reflective concentration systems, a point focus refractive concentrator and a flat module. All the systems have been measured when soiled and then after cleaning, achieving different increases of I{sub SC}. In general, results show that CPV systems are more sensitive to soiling than flat panels, accumulating losses in I{sub SC} of about 14% on average in three different tests conducted at IES-UPM and CSES-ANU test sites in Madrid (Spain) and Canberra (Australia). Some concentrators can reach losses up to 26% when the system is soiled for 4 months of exposure. (author)

14 SOLAR ENERGY↗

Insights on the continuous representations of piecewise-smooth nonlinear systems: limits of applicability and effectiveness

Dynamical systems subject to intermittent contact are often modeled with piecewise-smooth contact forces. However, the discontinuous nature of the contact can cause inaccuracies in numerical results or failure in numerical solvers. Representing the piecewise contact force with a continuous and smooth function can mitigate these problems, but not all continuous representations may be appropriate for this use. Here, five representations used by previous researchers (polynomial, rational polynomial, hyperbolic tangent, arctangent, and logarithm-arctangent functions) are studied to determine which ones most accurately capture nonlinear behaviors including super- and subharmonic resonances, multiple solutions, and chaos. The test case is a single-DOF forced Duffing oscillator with freeplay nonlinearity, solved using direct time integration. This work intends to expand on past studies by determining the limits of applicability for each representation and what numerical problems may occur.

42 ENGINEERING↗

Understanding of bacterial lignin extracellular degradation mechanisms by Pseudomonas putida KT2440 via secretomic analysis

Abstract Background Bacterial lignin degradation is believed to be primarily achieved by a secreted enzyme system. Effects of such extracellular enzyme systems on lignin structural changes and degradation pathways are still not clearly understood, which remains as a bottleneck in the bacterial lignin bioconversion process. Results This study investigated lignin degradation using an isolated secretome secreted by Pseudomonas putida KT2440 that grew on glucose as the only carbon source. Enzyme assays revealed that the secretome harbored oxidase and peroxidase/Mn 2+ -peroxidase capacity and reached the highest activity at 120 h of the fermentation time. The degradation rate of alkali lignin was found to be only 8.1% by oxidases, but increased to 14.5% with the activation of peroxidase/Mn 2+ -peroxidase. Gas chromatography–mass spectrometry (GC–MS) and two-dimensional 1 H– 13 C heteronuclear single-quantum coherence (HSQC) NMR analysis revealed that the oxidases exhibited strong C–C bond ( β-β , β -5, and β -1) cleavage. The activation of peroxidases enhanced lignin degradation by stimulating C–O bond ( β -O-4) cleavage, resulting in increased yields of aromatic monomers and dimers. Further mass spectrometry-based quantitative proteomics measurements comprehensively identified different groups of enzymes particularly oxidoreductases in P. putida secretome, including reductases, peroxidases, monooxygenases, dioxygenases, oxidases, and dehydrogenases, potentially contributed to the lignin degradation process. Conclusions Overall, we discovered that bacterial extracellular degradation of alkali lignin to vanillin, vanillic acid, and other lignin-derived aromatics involved a series of oxidative cleavage, catalyzed by active DyP-type peroxidase, multicopper oxidase, and other accessory enzymes. These results will guide further metabolic engineering design to improve the efficiency of lignin bioconversion. Graphical Abstract

09 BIOMASS FUELS↗

Notional Chemical Facility PathTrace Modeling Study

This SAND report provides system effectiveness analysis results for notional chemical facilities. Two facilities were analyzed in total, evaluating the effectiveness of the unique security systems in place at each location. Each analysis looked at a range of threat and response capabilities, specific target configurations, and task times to acquire target material in both theft and release scenarios. This report details results for both facilities.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advanced Reactor Safeguards and Security - Advanced Delay Technologies

As a new generation of reactors is developed, reducing the cost of physical security without impacting the required system effectiveness will help to make new reactors economical. This report discusses several access delay technologies available to help improve the overall effectiveness of the physical security system. These technologies include both passive and active delay elements, as well as guidance on best practices related to security by design principles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗