Search NASA⌕ Search

SEARCH · Search NASA

Results for “TESTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Trajectory Reconstruction of Orion Ground Test Article Water Impact Tests

The Orion Crew Module is a component of NASA’s Multi-Purpose Crew Vehicle that will be used for future missions to low Earth orbit and beyond. Ten water impact tests of the Orion Ground Test Article (GTA) were conducted at the Hydro Impact Basin at NASA Langley Research Center in 2016 and were designed to provide data for the validation of the LS-DYNA model used to determine the Crew Module structural loads during ocean splashdown, and the determination of an acceptable Model Uncertainty Factor to apply to simulation results used to drive the design. Post-test data obtained from the onboard sensors were used to reconstruct the GTA trajectories both before and after water impact. Results from one vertical test and two swing tests are presented and compared to videos taken for each test.

Lugo, Rafael A.↗

Acoustic Testing of the Tiltrotor Test Rig in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel

The Tiltrotor Test Rig (TTR) was tested in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel from 2017 to 2018. The primary goal of the test was to understand the operational capabilities of the TTR, while also acquiring research data, including acoustic data. Four microphones were placed around the TTR: two on the wind tunnel floor and two on struts. Acoustic measurements of the TTR rotor were acquired to 1) understand the acoustic testing capabilities of the TTR in the NFAC 40- by 80-FootWind Tunnel, 2) compare to previous XV-15 rotor acoustic data acquired in the NFAC 80- by 120-Foot Wind Tunnel, and 3) provide data for future validation studies. A data quality study revealed that the NFAC 40- by 80-Foot Wind Tunnel is an adequate acoustic environment to test the TTR rotor. For a given thrust and advance ratio, a shaft angle sweep was performed and acoustic measurements were compared against 1996 and 1999 XV-15 data in the NFAC 80- by 120-Foot Wind Tunnel; differences between the three tests are discussed.

40- by 80-FootWind Tunnel↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics

A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA’s Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were ≥ 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.

George C. Soulas↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Accelerance Decoupling: An Approach for Removing the Influence of the Test Stand from the Integrated Modal Test

The main objective for launch vehicle (LV) modal testing is to quantify the LV’s modal properties in the free-free state (post pad separation). However, given the size of most LV systems, free-free testing is a challenge and often not feasible. With this, a test stand, typically the launch pad itself, is introduced as the means of support. This shifts the challenge to developing robust numerical methods for removing the influence of the launch pad from the integrated system modal test. The Space Launch System (SLS) is no exception where the mobile launcher (ML) is used to support the vehicle for the integrated modal test (IMT). For the IMT, it is well understood from pre-test analysis with finite element models (FEMs) of the SLS and SLS coupled to ML that the ML has a significant influence on the SLS modal properties especially in the lower frequency range where the primary SLS bending modes exist. An accelerance decoupling (AD) method has been formulated for the purpose of “subtracting out” the influence of the ML from the IMT results. With AD, the SLS decoupled frequency response functions (FRFs) are directly extracted from the IMT FRFs. The subject approach is aimed to utilize measured data only and achieve a robust FRF decoupling scheme. AD is derived from a widely used coupling technique called “Receptance Coupling” (RC). The AD core equation reverses the RC process and utilizes a pair of auxiliary equations that enable the core equation to be resolved based on measured data only. In AD, the decoupled component FRFs are extracted from the coupled system FRFs with a transformation to remove the contribution of the “subtractive component”. This paper addresses the AD’s operational flexibility to resolve SLS free-free modal properties from coupled system measured data but also the possibility to include data from FEM if there is enough confidence in the FEM or if it is asserted that the effect to the final outcome is reasonable.

Accelerance decoupling↗

Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

A shake test of the Large Rotor Test Apparatus (LRTA) was performed in an effort to enhance NASAscapability to measure dynamic hub loads for full-scale rotor tests. This paper documents the results of theshake test as well as efforts to calibrate the LRTA balance system to measure dynamic loads.Dynamic rotor loads are the primary source of vibration in helicopters and other rotorcraft, leading topassenger discomfort and damage due to fatigue of aircraft components. There are novel methods beingdeveloped to reduce rotor vibrations, but measuring the actual vibration reductions on full-scale rotorsremains a challenge. In order to measure rotor forces on the LRTA, a balance system in the non-rotatingframe is used. The forces at the balance can then be translated to the hub reference frame to measure therotor loads. Because the LRTA has its own dynamic response, the balance system must be calibrated toinclude the natural frequencies of the test rig.

Shake Test Results↗

Acoustic Testing of the Tiltrotor Test Rig in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel

The Tiltrotor Test Rig (TTR) was tested in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel from 2017 to 2018. The rotor system can be configured in airplane mode, with the rotor plane perpendicular to the wind flow, and in helicopter mode, with the rotor plane parallel to the wind flow. Four microphones were placed around the TTR: two on the wind tunnel floor and two on struts. The primary goal of the test was to understand the operational capabilities of the TTR, while also acquiring research data as available. Limited measurements of the blade vortex interaction (BVI) noise of the TTR rotor were taken to not only understand the acoustic testing capabilities of the TTR in the NFAC 40- by 80-Foot Wind Tunnel, but to also compare to previous tests and to be used for future validation studies. In particular, data will be compared to measurements of an XV-15 rotor previously acquired in the NFAC 80- by 120-Foot Wind Tunnel.

Tiltrotor Test Rig↗

MSFC Thermal Testing Lessons Learned Course. Section 3: Lessons Learned from Protoflight StarBurst Instrument Thermal Vacuum Test

MSFC thermal engineers will be presenting lessons learned while preparing and conducting thermal tests. This course will cover practical real world examples of thermal chamber and vacuum chamber testing from engineering development units to system level testing on flight hardware. Special topics include large scale testing preparation, requirement tailoring from parent documents, and cryogenic development testing.

thermal discipline↗

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler↗

A Capable and Temporary Test Facility on a Shoestring Budget: The MSL Touchdown Test Facility

The Mars Science Laboratory mission (MSL) has undertaken a developmental Touchdown Test Program that utilizes a full-scale rover vehicle and an overhead winch system to replicate the skycrane landing event. Landing surfaces consisting of flat and sloped granular media, planar, rigid surfaces, and various combinations of rocks and slopes were studied. Information gathered from these tests was vital for validating the rover analytical model, validating certain design or system behavior assumptions, and for exploring events and phenomenon that are either very difficult or too costly to model in a credible way. This paper describes this test program, with a focus on the creation of test facility, daily test operations, and some of the challenges faced and lessons learned along the way.

rover↗

James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

JWST Thermal Core 2 Test↗

Development and Testing of Pulse Guns for Combustion Instability Testing

Combustion stability requirements of a liquid propellant rocket engine are most commonly verified by evaluating the oscillatory pressure or vibration characteristics following an artificial disturbance of the combustion in the combustion chamber. Two types of devices are most commonly used for dynamic stability rating – nondirectional bombs and pulse guns. Bombs have historically been used most often, especially for the large engines developed around the Apollo era. However, bombs in recent years have become much more expensive and difficult to procure, and their transportation and handling requirements have become more demanding. Pulse guns, with inherently less expensive materials, and far less restrictive handling and shipping requirements, have become an attractive alternative. The NASA Marshall Space Flight Center has developed a pulse gun for use during future development programs at the center, and as a design reference for interested commercial users. The objective of this paper is to present the different variants of the pulse gun and characterize performance over a range of parameters. The parameters include the breech diameter and corresponding volume, barrel length, amount of gun powder used, the method of containing the gunpowder within the breech, and the pressure rating of the burst disk. In total, 44 tests were conducted with the pulse gun firing into a test chamber pressurized to 2300 psig with gaseous nitrogen. The best experimental results – including the highest and most consistent peak pressure amplitudes recorded by dynamic pressure sensors in the test chamber – were from a configuration consisting of a 0.40” inner-diameter breech, 15-16 grains of gunpowder wrapped in cigarette paper, and a 24,000 psid burst disk. With this configuration, the zero-to-peak overpressures recorded in the test chamber ranged from about 37% to 58% of the 2300 psig mean pressure, which is adequate for typical combustion stability rating. To complement the data analysis, the acoustics of the pressure waves as they propagated through the pulse gun and into the test chamber were modeled. A more comprehensive final report of this pulse gun development program is planned to be available in the near future.

Pulse Gun↗

Computational Fluid Dynamics Models of the NASA White Sands Test Facility Particle Impact Test Nozzles

The particle impact ignition mechanism is considered to be the most effective means for igniting metals in gaseous oxygen environments and is a concern for every oxygen system. For this reason, the National Aeronautics and Space Administration (NASA) commits a large amount of resources attempting to understand and defend against this phenomenon. The most practical means of accomplishing this is through extensive of testing. To this end, over the years NASA has developed and built a facility and various apparatuses to test material or component vulnerability to a particle impact ignition. In testing materials, NASA uses sub-sonic and supersonic nozzles to replicate the conditions that a material is expected to experience in service. However, challenges include obtaining an understanding of the gas dynamics and of the particle behavior through and up to the point of impact at the material under test. One means of addressing these challenges is the use of computational fluid dynamics (CFD). If a CFD model can be built and validated, the model can then be used to confidently interrogate changes to inlet conditions and particle geometries, as well as changes to nozzle geometries to better simulate a material’s in-situ conditions and greatly reduce or eliminate trial-and-error approaches in testing. This paper will show NASA’s approach to and results of using CFD to better understand their particle impact nozzles.

Computational Fluid Dynamics↗

CMG assembly life test and engineering evaluation test, M-509 experiment

The initial checkout of the control moment gyro system for the astronaut stabilizer maneuvering unit is described, and the test results are presented. The life test proceeded smoothly to its completion, and problem areas encountered in the engineering tests are described. These tests included command rate and torquer current transfer, cage and lock, static inverter and signal noise, dynamic response, closed loop drift rate, and gimbal disturbance torque evaluation tests.

Cramer, P. S.↗

Fabrication and test of a space power boiler feed electromagnetic pump. 3: Endurance and final performance tests

A three-phase helical induction electromagnetic pump designed for the boiler feed pump of a potassium Rankine cycle space power system was developed and built. It was mounted in a liquid metal test loop and successfully tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction head from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. Maximum efficiency at design point conditions of 3.25 lb/sec flow rate, 240 psi developed head, 1000 F potassium inlet temperature, and 800 F NaK coolant inlet temperature was 16.3 percent. After the performance tests the pump was operated without any difficulty at design point for 10,000 hours, and then a limited number of repeat performance tests were made. There was no appreciable change in pump performance after 10,000 hours of operation. A supplementary series of tests using the quasi-square wave power output of a dc to three-phase ac inverter showed that the pump would operate without difficulty at a frequency as low as 25 Hz, with little loss in efficiency.

Powell, A. H.↗

The pseudonoise test set: Communication system's performance evaluation based upon RMS error testing

A pseudonoise (PN) test set was built to provide a relatively easy means of accurately determining the end-to-end rms error introduced by a communication system when subjected to wideband data. It utilizes a filtered pseudorandom sequence generator as a wideband data source, providing a convenient means for digitally delaying the input reference signal for comparison with the distorted test communication system output. In addition to providing a means to measure the end-to-end rms error and the average delay of a communication system, the PN test set also provides a means to determine the tested system's impulse response and correlation function. The theory of PN testing is discussed in detail along with the most difficult aspects of implementation, the building of matched filter pairs. Both analytical and empirical results are reported which support the contentions that this is an accurate and practical way to acquire figures of merit for complete communication systems.

Wallace, G. R.↗